A COMPARATIVE STUDY OF REFRIGERANTS R12, R134A, R407 & R717 FOR VAPOUR COMPRESSION REFRIGERATION SYSTEM

Similar documents
NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

η second law = Second law efficiency

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

A Comparison Between Refrigerants Used In Air Conditioning

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

CHAPTER 1 INTRODUCTION

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

DEEPAK PALIWAL, S.P.S.RAJPUT

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Design of LPG Refrigeration System

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

CHAPTER 1 INTRODUCTION

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Study of R161 Refrigerant for Residential Airconditioning

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

Thermodynamics II Chapter 5 Refrigeration

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Enhancement of COP in Vapour Compression Refrigeration System

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Enhancement of COP using Nanoadditives in Domestic Refrigerator

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Thermodynamics I. Refrigeration and Heat Pump Cycles

International Journal of Advance Engineering and Research Development

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Department of MCE, Islamic University of Technology 2. Abstract

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

ADVANCES in NATURAL and APPLIED SCIENCES

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Chapter 10. Refrigeration and Heat Pump Systems

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

ADVANCES in NATURAL and APPLIED SCIENCES

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Low GWP Refrigerants for Air Conditioning Applications

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Chapter 11 REFRIGERATION CYCLES

ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Transcription:

A COMPARATIVE STUDY OF REFRIGERANTS R12, R134A, R407 & R717 FOR VAPOUR COMPRESSION REFRIGERATION SYSTEM Md. Nawaz Khan 1, Md. Mamoon Khan 2 1 Assistant Professor, Department of Mechanical Engineering, Integral University, Lucknow, Uttar Pradesh, (India) 2 Faculty, Department of Mechanical Engineering, Rohilkhand University, Bareilly, Uttar Pradesh, (India) ABSTRACT The present paper explains the comparative performance analysis of vapour compression refrigeration system with four different refrigerants R12, R134a, R407 and R717. The vapour compression refrigeration system consist of compressor, condenser, expansion valve and an evaporator. The comparative study of refrigerants has been carried from which the results has been obtained is plotted in the graph. The evaporator temperature has been varied from -10 to -40 C and degree of subcooling from 0 to 10 C. The parametric study reveals the effect of these parameters on performance of vapour compression system. The four configurations are Simple Vapour Compression system, Multiple Compression System with flash chamber, Multiple compression system with water intercooler and liquid subcooler and Multiple compression system with Flash intercooling and multiple expansion valve, The results showed that the refrigerant R717 have highest COP for Simple Vapour Compression system, Multiple Compression System with flash chamber and MCS with Flash intercooling and multiple expansion valve followed by the R12 in Simple VCS, R134a in Multiple Compression System with flash chamber and R407 in Multiple compression system with Flash intercooling and multiple expansion valve but in Multiple compression system with water intercooler and liquid subcooler the highest COP is of R12 followed by R717 for the condensation temperature of 48⁰C and evaporating temperature is -10⁰C.The effects of the main parameters of performance analysis such as refrigerant type, mass flow rate and condenser discharge temperature also investigated for various configuration. Keywords: Refrigeration, R12, R134a, R407, R717, Vapour Compression System I. INTRODUCTION Energy consumption in buildings has become an important aspect on a global scale. Energy costs and environmental concerns have made energy optimization a crucial issue for buildings. Therein energy efficiency is a prime mover in reducing global warming emissions. In respect to this, new technologies to conserve energy, to use energy effectively, to use alternative energy sources and to reduce the energy running costs of buildings such as solar energy, geothermal energy, wind energy etc. are under continuous development. There in energy efficiency is a prime mover in reducing global warming emissions. The rapid escalation in energy costs, the issues of security of supply, the emission of polluting substances as well as global climate 206 P a g e

change, have all made refrigerating methods in their current forms unsustainable at present and in the future. Therefore to overcome these problems, alternative solutions must be studied which focus on the reduction of energy consumption and the improvement of heating performance while reducing adverse effects on the environment. II. LITERATURE REVIEW S.Venkataiah et al (2013) in his paper presents the simulation results of a 1.5Ton (5.276kW/18000BTU/Hr) Capacity room air conditioner with some selected refrigerants thathave been assessed for their suitability as alternative refrigerants to R-22 for air-conditioning applications. The Performance of the selected refrigerants viz., R-22, R-134a, R407C, R410A, R404A, R507A, R290, and R600a is considered in the analysis whereas A.Baskaran et al(2012) performed analysis on a vapour compression refrigeration system with various eco-friendly refrigerants of HFC152a, HFC32, HC290, HC1270, HC600a, RE170 were done and their results were compared with R134a as possible alternative replacements. The results showed that the alternative refrigerants investigated in the analysis RE170, R152a and R600a have a slightly higher performance coefficient (COP) than R134a for the condensation temperature of 50⁰C and evaporating temperatures ranging between -30C and 10C.M.Mohanraj et al (2011) in his studies reported about new refrigerant mixtures in domestic refrigerators, commercial refrigeration systems, air conditioners, heat pumps, chillers and in automobile air conditioners. In addition, the technical difficulties faced with new refrigerant mixtures, further research needs in this field and future refrigerant options for new upcoming systems have been discussed in detail. This paper concludes that HC based refrigerant mixtures are identified as a longterm alternative to phase out the existing halogenated refrigerants in the vapour compression-based systems also in the same year. Hailei Wang et al (2011) in his study introduced a novel thermally activated cooling concept a combined cycle couples an ORC (organic Rankine cycle) and a VCC (vapor compression cycle).a systematic design study was conducted to investigate effects of various cycle configurations on overall cycle COP. With both subcooling and cooling recuperation in the vapor compression cycle, the overall cycle COP reaches 0.66 at extreme military conditions with outdoor temperature of 48.9 C. M.I. Karamangil et al (2010) presents a literature review, especially in recent years, on the absorption refrigeration systems (ARSs), the currently used refrigerant absorbent pairs and their alternatives. It was concluded that performances of the cycles improve with increasing generator and evaporator temperatures, but reduce with increasing condenser and absorber temperatures. Zaghdoudi et al (2010) have simulated the performance of ten alternate refrigerants such as [R134a, R290, R600, R404A, R407A, R407C, R407D, R410A, R410B and R417A] to replace R22 in Air conditioner of 9000BTU/hr (0.75TR) capacity by using NIST Cycle-D. Brandon et al (2007) in his paper investigated the economic feasibility of a water-based vapor compression chiller with a nominal capacity of 3520 kw (1000 ton). The results show that water-based vapor compression refrigeration systems will not be economically attractive without substantial and successful efforts to develop low-cost, high capacity compressor. James. M. Calm (2006) summarized analysis of refrigerant options for chillers. The 28 refrigerants addressed include chlorofluorocarbon (CFC), Hydro-chlorofluorocarbon (HCFC), Hydrocarbon (HC). He discussed the relative importance of the refrigerant related and energy related components of chillers emissions. Dongsoo Jung et al (1999) studied Multi-stage heat pumps composed of a condenser, evaporator, compressor, suction line heat exchanger, and low and/or high stage economizers are studied by computer simulation. The results indicate that the three-stage super heat pump with appropriate 207 P a g e

mixtures is up to 27.3% more energy efficient than the conventional single-stage system. Jameel-Ur-Rehman et al (1998) in his study developed the thermodynamic models of the two stage system (TSS) to simulate system performance with respect to the interstage temperature and heat-exchanger parameters. The TSS performance is better than for a simple cycle and depends on the interstage temperature of the flash intercooler. S.M. Zubair et al (1996) performed thermodynamic analysis of HFC-134a vapor-compression refrigeration cycles by both the first and second laws of thermodynamics. Second-law analysis is carried out for both twostage and mechanical-subcooling refrigeration cycles. It is found that most of the losses are due to low compressor efficiency. Irreversibilities of expansion valves and condenser are also significant. O.Badr et al (1990) studied vapour-compression units which are the most widely used refrigeration systems. Interactive computer routines have been composed, in BASIC language, in order to permit the prediction of the performances of simple, multi-evaporator multi-stage compressor vapour-compression refrigerators. V.K. Gupta et al (1986) in his study employed two-stage compression on high temperature (HT) side and singlestage compression on low temperature (LT) side is numerically optimized for preliminary design of the system. Overall coefficients of performance of the system are found to be 2.8 to 7.4, if the system operates within the consider ranges of the operating variables/parameters. Mark R. Shelton et al (1985) based on his model, an index of performance for pure refrigeration is proposed. This index can be used to quickly identify thermodynamically efficient refrigerants, and to predict the performance of refrigeration cycles with very little computational effort. V.K. Gupta et al (1983) analysed the optimum thermodynamic performance of three stage refrigerating system. In his analysis the refrigeration efficiency, mass flows through IP and HP compressors, power input and inter-stage pressures at the optimum thermodynamic performance of three stage systems are presented graphically for the most common refrigerants, R 12, R 22 and R 717. III. SYSTEM DESCRIPTION The cycle consists of a compressor, discharge line, condenser, expansion device, evaporator, compressor suction line, and an optional suction line heat exchanger. The simulation cycle is outlined by different states as shown in the Fig 1. These state points are the following: the suction gas (1) is compressed and discharged into the discharge line (2). The discharge line leads the refrigerant to the inlet of the condenser (3). The condensed and sub cooled refrigerant in the condenser outlet (4) is either lead to the liquid inlet of the suction gas heat exchanger (SGHX) if this has been selected, or directly to the inlet of the expansion valve. If a SGHX is included the exit condition (5) will be different from condition (4). From the expansion valve outlet (6) the refrigerant is lead to the evaporator. The evaporated and superheated refrigerant in the evaporator outlet (7) is lead through the suction line, either to the gas side inlet of the SGHX, if this has been selected, or to the compressor inlet (1). If a SGHX is included the exit condition (8) will be different from condition (1). Fig. 1: Schematic Diagram of System Layout 208 P a g e

International Journal of Advance Research In Science And Engineering http://www.ijarse.com Fig. 2. Pressure Enthalpy Diagram of Vapour Compression System IV. METHODOLOGY Cool Pack Software: It covers calculation of refrigeration properties (property plots, thermodynamic and thermo physical data, refrigerant comparisons), cycle analysis- comparison of single stage and multi stage, system dimensioning- calculation of component sizes from general configuration criteria, System simulation-calculation of operating conditions in a system with known components with their operating parameters, evaluation of operation and evaluation of the system coefficient of performance with less power consumption. Fig 3 shows typical screen shots during the usage of COOLPACK in the analysis 4.1 Thermodynamic Analysis Fig. 3: Screenshots of Coolpack Software This topic presents the simulation results of a 100 Ton Capacity of freezing plant with selected refrigerants that have been assessed for their suitability. The Performance of the refrigerants R-12, R-134a, R407Cand R717 is considered Table 1. Properties of Different Refrigerants used for the Analysis S.No Property R12 R134a R407a R717 ₂ ₂ ₂ ₃ 20%R32/40% Chemical formula / blend 1 CCl F CH FCF R125/40%R13 NH3 composition 4a 2 Molar Mass (kg/kmol) 120.914 102.03 86.204 17.03 3 Critical Point Temperature Tc ( C) 113.23 101.06 86.034 132.25 4 Critical Pressure (Pc) (bar) 42 40.593 46.298 113.3 5 Critical Density (kg/m³) 565 511.9 484.23 225 6 Boiling Point -21.6-26.074-43.8-33.33 7 ODP 1 0 0 0 8 GWP 2400 1300 1770 0 209 P a g e

4.2 Cycle Specifications for Simulation The cycle inputs are evaporating temperature ranging from -10ºC to -40 C and condensing temperature is 48ºC. Condenser sub cooled temperature ranges from 0 to 10 C.Pressure losses in the condenser and evaporator are neglected. Cooling capacity in the evaporator is selected as 29 Ton, isentropic efficiency of compressor is taken as 1, compressor heat loss factor is considered as zero also suction line super heat is considered as zero. V. RESULTS The comparative study for refrigerants R12, R134a, R407 and R717 has been carried out of four different configuration of vapour compression refrigeration system and the results are shown in the form of graph. Fig.4. C.O.P vs Degree of Subcooling Figure 4 represents the variation of C.O.P with degree of subcooling. From the graph it is observed that the C.O.P of all refrigerants increase with degree of subcooling. The C.O.P of R12 is maximum for 10 C of subcooling which is 3.724 while the C.O.P of R134A, R407 & R717 are 3.648, 3.493, and 3.677 respectively. Figure 5 represents the variation of mass flow rate with degree of subcooling. The mass flow rate of R717 is minimum for refrigeration system and nearly same for all the values of degree of subcooling. The mass flow rate of R12 is maximum which 0.9664 is and it decreases with increase in degree of subcooling followed by R134A and R407 while the R717 has minimum mass flow rate and nearly the same value for all the values of degree of subcooling. Fig.5. Mass Flow Rate vs Degree of Subcooling In figure 6 the variation between condenser discharge and degree of subcooling is plotted on the graph, condenser discharge decreases with increase in degree of subcooling. The maximum value of condenser discharge is for R407 at 0 C is 131.9 kw and minimum is 128,6 at 10 C of degree of subcooling followed by 210 P a g e

International Journal of Advance Research In Science And Engineering R134A, R12 and R717. http://www.ijarse.com Fig.6. Condenser Discharge vs Degree of Subcooling Figure 7 represents the variation of C.O.P with evaporator temperature. From the graph it is observed that the C.O.P of all refrigerants increase with evaporator temperature. The C.O.P of R12 is maximum for -10 C of evaporator temperature which is 3.659 followed by the R717, R134A and R407whose values are 3.643, 3.574 & 3.423 respectively. Fig.7. C.O.P vs Evaporator Temperature Figure 8 represents the variation of mass flow rate with evaporator temperature. The mass flow rate of R717 is minimum for refrigeration system and nearly same for all the values of evaporator temperature. The mass flow rate of R12 is maximum which 0.8964 is and it increases with increase in degree of subcooling followed by R134A and R407. Fig.8. Mass Flow Ratevs Evaporator Temperature 211 P a g e

In figure 9 the variation between condenser discharge and evaporator temperature is plotted on the graph, condenser discharge decreases with increase in degree of subcooling. The maximum value of condenser discharge is for R407 at 0 C is 158.8 kw and minimum is 129.2kW at -10 C of evaporator temperatue followed by R134A, R12 and R717. The values of R717 is nearly same for R12 for all the values of evaporator temperature. Fig.9. Condenser Discharge vs Evaporator Temperature VI. CONCLUSION In the present study four different refrigerants R12, R134A, R407 and R717for vapour compression refrigeration system are used for the performance analysis. Considering the comparison of coefficient of performance (COP), mass flow rate and discharge temperature of the tested refrigerants and also the main environmental impacts of ozone layer depletion and global warming, refrigerant R717 was found to be the most suitable for simple Vapour compression refrigeration system. VII. NOMENCLATURE VCS = Vapour Compression System MCS = Multistage Compression System SGHX = Suction Gas Heat Exchanger CFCS = Chlorofluorocarbons COP = Coefficient of Performance GWP = Global warming potential HCFCs = Hydro chlorofluorocarbons HCs = Hydrocarbons HFCs = Hydro fluorocarbons ODP = Ozone depletion potential TR = Ton of refrigeration 212 P a g e

International Journal of Advance Research In Science And Engineering REFERENCES http://www.ijarse.com [1] Brandon F. Lachner Jr., Gregory F. Nellis, Douglas T. Reindl (2007), The commercial feasibility of the use of water vapor as a refrigerant International Journal of Refrigeration, Volume 30, Issue 4, Pages 699 708 [2] Dongsoo Jung, Hak-Jun Kim, Ookjoong Kim (1999), A study on the performance of multi-stage heat pumps using mixtures International Journal of Refrigeration, Volume 22, Issue 5, Pages 402 413. [3] Hailei Wang, Richard Peterson, Tom Herron (2011) Design study of configurations on system COP for a combined ORC (organic Rankine cycle) and VCC (vapor compression cycle) Energy, Volume 36, Issue 8, Pages 4809 4820. [4] Jameel-Ur-Rehman Khan, Syed M. Zubair (1998) Design and rating of a two-stage vapor-compression refrigeration system Energy, Volume 23, Issue 10, Pages 867 878. [5] M. Mohanraj*, C. Muraleedharan and S. Jayaraj (2011) A review on recent developments in new refrigerant mixtures for vapour compression-based refrigeration, air-conditioning and heat pump units International Journal of Energy Research, Volume 35, Issue 8, pages 647 669. [6] M.I. Karamangila, S. Coskunb, O. Kaynakli, N.Yamankaradeniz (2010), A simulation study of performance evaluation of single-stage absorption refrigeration system using conventional working fluids and alternatives Renewable and Sustainable Energy, Reviews Volume 14, Issue 7, Pages 1969 1978. [7] Mark R. Shelton1, Ignacio E. Grossmann (1985) A shortcut procedure for refrigeration systems Computers & Chemical Engineering, Volume 9, Issue 6, Pages 615 619. [8] O. Badr, P.W. O'Callaghan, S.D. Probert (1990), Vapour-compression refrigeration systems Applied Energy, Volume 36, Issue 4, Pages 303 331. [9] S. Venkataiah and Dr. G. VenkataRao (2013) A Comparative Study of the Performance Characteristics of Alternative Refrigerants to R-22 in Room Air-conditioners International Journal of Engineering Research and Technology, Volume 6, pp. 333-343 [10] S.M Zubair, M Yaqub, S.H Khan (1996) Second-law-based thermodynamic analysis of two-stage and mechanical-subcooling refrigeration cycles International Journal of Refrigeration, Volume 19, Issue 8, Pages 506 516. [11] Syed Md. Tarique, M. AltamushSiddiqui (1999) Performance and economic study of the combined absorption/compression heat pump Energy Conversion and Management, Volume 40, Issue 6, April 1999, Pages 575 591. [12] V.K. Gupta, M. Prasad (1983) Optimum Thermodynamic Performance Of Three-Stage Refrigerating Systems International Journal of Refrigeration, Volume 6, Issue 2, Pages 103 107. [13] V.K. Gupta (1986) Optimum design of multi-stage cascaded refrigeration-heat pump system Journal of Heat Recovery Systems Volume 6, Issue 3, Pages 235 244. [14] Zaghdoudi M.C., S.Maalej, Y.Saad and M.Bouchaala, (2010) A Comparative study on the Performance and Environmental Characteristics of Alternatives to R22 in Residential Air Conditioners for Tunisian Market, Journal of Environmental science and Engineering, Volume 4, No.12. 213 P a g e