Refrigeration Cycle Demonstration Unit R634

Similar documents
Refrigeration Cycle Demonstration Unit R633

P.A. Hilton Ltd. Figure 2: HC655A Optional Computer Linking Upgrade

Mechanical Heat Pump R515

Air & Water Heat Pump R832

Vapour Jet Refrigerator / Heat Pump R853

Bench Top Cooling Tower H893

Ventilation Trainer B500

A660 Air Conditioning Laboratory Unit

Heat Transfer Service Unit H112

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Refrigeration Technology in Building Services Engineering

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Energy Use in Refrigeration Systems

Pressure Enthalpy Charts

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Transcritical CO2 Bottle Cooler Development

Sarthak Thakar, 2 R.P.Prajapati 1

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

REFRIGERATION AND AIR CONDITIONING

Simple Compression Refrigeration Circuit Unit TSCR

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

International Journal of Informative & Futuristic Research ISSN (Online):

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

II. OBJECTIVE OF RESEARCH

SWIMMING POOL HEAT PUMPS

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

CHAPTER 1 INTRODUCTION

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Technical Development Program

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

EXPERIMENTAL INVESTIGATION ON VARIABLE SPEED OPERATION OF AIR CONDITIONING

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Chapter 2. Alternatives to HCFCs and their Characteristics

Performance Assessment of Water Cooled Condenser Refrigeration System

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT

Refrigerant Dryers DRY with PDP Indicator

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Modular Air Cooled Scroll Chillers

AQUASNAP JUNIOR 30RHV

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

AIR TO WATER HEAT PUMPS SPECSHEET

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Design & Fabrication of Hybrid Cooler

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Sweden s leading air source heat pump

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

Refrigerator/Heat pump

OIL SEPARATORS APPLICATIONS

Design of LPG Refrigeration System

DEEPAK PALIWAL, S.P.S.RAJPUT

3400-3A Refrigeration System Demonstrator

Experiment 12 Shell and Tube Heat Exchanger. Aim of this Experiment

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

CHAPTER 1 INTRODUCTION

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

The Refrigeration Cycle

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

DEVICE FOR EXTRACTING WATER FROM AIR

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

COLD. Basic Training Course II. November ESSE - Wilhelm Nießen

The Refrigeration Cycle

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Study of R161 Refrigerant for Residential Airconditioning

Thermodynamics I. Refrigeration and Heat Pump Cycles

Refrigeration Training System

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

Transcription:

Refrigeration Cycle Demonstration Unit R634 Figure 1: R634 Unit shown with R634A and R634B fitted Ozone friendly, low pressure, non-toxic working fluid allows evaporation and condensation to be safely observed in glass cylinders. A Bench top unit specifically designed for unsupervised Fast response to controls allows efficient use of laboratory time. Negligible operating and maintenance costs. Two-year warranty. Page 1 of 5

Experimental Capabilities Demonstration of the vapour compression refrigeration and heat pump cycle with visual observation of all-important processes. Investigation and demonstration of the pressure-temperature relationship during evaporation and condensation. Demonstration of: - Charging Pumping over or pumping down the refrigerant charge into the condenser. The effect of air in refrigeration systems. Determination of effect of evaporating and condensing temperatures on the refrigeration rate and condenser heat output. Investigation of the effect of compressor pressure ratio on system performance. Determination of overall heat transfer coefficient in a simple shell and tube type heat exchanger. With the addition of the optional temperature indicator R634A: - Development of a refrigeration cycle diagram on a pressure - enthalpy chart. With the addition of the optional digital wattmeter R634B: - Measurement of the electrical power used to drive the vapour compression refrigeration and heat pump cycle. Page 2 of 5

Special Design Features Specifically designed for safe unsupervised operation by students. Low-pressure non-toxic working fluid (Pentafluorobutane / Perfluoropolyether) enables both evaporation and condensation to be safely observed in glass components. No Ozone Depleting Potential and non- flammable working fluid allows world wide support with no shipping restrictions. Self contained bench top unit requiring only minimal electrical power and cooling water. Visual impact of the unit aids student understanding of a complex process. Low thermal inertia allows a large range of experiments to be carried out in a short period. Optional factory, or user fitted, upgrades to give digital temperature readout (R634A) and compressor electrical power consumption (R634B). Description The vapour compression refrigeration and heat pump cycle is of paramount importance in food and drug preservation, air conditioning, heat pumps as well as other industrial and commercial process. The importance of the efficient and safe use of refrigeration systems has now been added to by the problems of ozone depletion and global warming. It is therefore more essential than ever before that students have a thorough understanding of both the practical aspects of refrigeration and the thermodynamic processes affecting the performance of the cycle. Often the most difficult aspect for new students to grasp is the process of evaporation at low pressure and condensation at high pressure. By utilising a non-toxic working fluid with a low vapour pressure, the evaporation and condensation processes are clearly visible in thick walled glass chambers. The evaporator consists of a closed, thick walled glass chamber containing a pool of working fluid into which is immersed a specially treated copper coil. An hermetic compressor draws vapour from the evaporator and compresses this before discharging it to the condenser. The reduction in evaporator pressure causes the refrigerant to boil, so extracting heat from the water flowing through the coil and generating more vapour to be drawn into the compressor. From the compressor the high-pressure vapour passes to the condenser, which is of similar construction to the evaporator but contains a nickel-plated water-cooled copper coil. Vapour condenses on the surface of the coil and falls to the bottom of the chamber. The heat given up by the refrigerant phase change is transferred to the cooling water flowing through the cooling coil. A float controlled expansion valve at the base of the condenser chamber controls the flow of high pressure refrigerant liquid returning to the evaporator. After passing through the expansion valve the refrigerant expands to form a liquid vapour mixture at the same pressure as the evaporator and the cycle is repeated. The standard instrumentation fitted enables measurement of the condenser and evaporator pressures and temperatures as well as water flow rates and water temperatures. The condensing and evaporating pressures are varied by adjustment of the water flow rate to the evaporator and condenser coils using integral control valves on individual flowmeters. An optional Digital Temperature Indicator Upgrade R634A, allows the measurement of the above temperatures plus the compressor discharge and condensed liquid temperatures to 0.1 C resolution. The addition of these parameters allows a complete refrigeration cycle diagram to be plotted on an SES36 Pressure-Enthalpy Diagram. An optional Digital Wattmeter Upgrade R634B allows measurement of the instantaneous electrical power being consumed by the compressor. Range 0-1999W resolutions 1 W. An optional Refrigerant flowmeter upgrade R634R allows measurement of the refrigerant flow whilst also acting as an expansion valve for the refrigerant cycle. Range 0.3-1.8g/s Page 3 of 5

Figure 2: Data showing pressure temperature relationships for refrigerant 300 Pressure vs Temperature at Saturation with Experimental data Vapour Pressure Condenser Data 250 Evaporator Data Saturation Vapour Pressure (knm -2 ) 200 150 100 50 0 0 10 20 30 40 50 60 70 80 Saturation Vapour Temperature ( C) Figure 3: Data showing the effect of air in refrigeration systems 300 Vapour Pressure and Temperature in the Condenser, With and Without Air Present 250 Saturation Vapour Pressure (knm -2 ) 200 150 100 50 Vapour Pressure Condenser Pressure (Without Air) Condenser Pressure (With Air) 0 0 10 20 30 40 50 60 70 80 Saturation Vapour Temperature ( C) Page 4 of 5

Specification General Refrigeration Cycle Demonstration Unit with lowpressure non-toxic refrigerant and water cooled cylindrical glass evaporator and condenser. Detailed A bench mounted vapour compression refrigeration cycle demonstration unit using a hermetic compressor and water cooled flooded glass condenser and evaporator. Unit operates on low-pressure non-toxic ozone friendly refrigerant. Internal electrical and mechanical safety devices allow for unsupervised operation by students. Standard instrumentation fitted enables measurement of the condenser and evaporator pressures and temperatures as well as water flow rates and water temperatures. Unit supplied with a detailed experimental operating and maintenance manual giving example experimental results and sample calculations. Equipment supplied with spares and accessories for two years normal operation together with a full twoyear warranty. Further specification details available on request An optional digital temperature indicator upgrade allows measurement of all system temperatures to 0.1 C with the addition of compressor discharge and condensed liquid temperatures so enabling a cycle diagram to be drawn on a Pressure-Enthalpy chart. Services required Electrical: A: 220/240 Volts Single Phase 50Hz (with earth/ground). Line current up to 4.5A at 230v. B: 110/120 Volts Single Phase 60Hz (with earth/ground). Line current up to 9.0A at 115v Water: 6 litre/minute at a minimum of 28m head. Electrical Specification Either: A: 220/240V Volts Single Phase 50Hz (with earth/ground) Or B: 110/120 Volts Single Phase 60Hz (with earth/ground) Shipping Specifications Net Weight: 64kg.(220/240v) 71kg (110/120v) Approximate Gross Weight: 100kg (220/240v) 107kg (110/120v) Packing Case Dimensions: 0.92 x 0.65 x 1.05m Packing Case Volume: 0.63m 3 Accessories and Spares Unit supplied with: One experimental operating and maintenance manual in English, French, or Spanish (Other languages on request). Accessories and spares for 2 years normal Also Available On Request Further detailed specification. Additional copies of instruction manual. Recommended list of spares for 5 years P.A.HILTON Ltd. Horsebridge Mill, King s Somborne, Stockbridge, Hampshire, SO20 6PX, England. Telephone: National (01794) 388382 International +44 1794 388382 Fax: National (01794) 388129 International +44 1794 388129 Ordering Information Order as: R634 Refrigeration Cycle Demonstration Unit Optional extras: R634A Digital Temperature Indicator Upgrade R634B Digital Wattmeter Upgrade R634R Refrigerant Flowmeter Upgrade E-mail: Website: sales@p-a-hilton.co.uk www.p-a-hilton.co.uk Page 5 of 5