DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Similar documents
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Advance Release September 2009

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

technical guide Water-Cooled Self-Contained Units

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a

Water-Cooled Self-Contained Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SKYPAK II Heating & Cooling Self Contained Packages

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

PACKAGE AIR CONDITIONER

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

VertiCool Aurora Engineering Guide

C13-Series Engineering Guide

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Split System Heat Pumps

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

PAJ3. Product Specifications

VariCool VAV Engineering Guide

Commercial High-Efficiency Condensing Units

Ruud Commercial Achiever Series Package Gas Electric Unit

High Heat COP. High/Low Stage

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MAC N-407 Air-Cooled Chiller

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

CoolSpot Engineering Guide

PAR5. Product Specifications

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MACH N-407 Heat Pump Air-Cooled Chiller

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Unit Features & Benefits RQPM/RQRM Series

Roof Top Packaged Unit (RTU-1) Specification

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Now In Production JULY 2008

Condensing Units & Air Handlers

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

KCC Centrifugal Fan Air Cooled Condensers

TECHNICAL SPECIFICATIONS

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

WCH5**4. Product Specifications

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Model CPH Horizontal Water-Cooled Air Conditioning Unit

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

13 SEER CONDENSING UNITS & AIR HANDLERS

13 SEER PACKAGE GAS / ELECTRIC UNIT (575V -3 Ph -60Hz) 36 to 61 MBtuh

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

COMMERCIAL AIR HANDLER

Air-Cooled Condensing Units with Compact Screw Compressors

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

4YCC3048A3096A /3/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

GENERAL ELECTRIC AIR HANDLING UNITS DIRECT EXPANSION. ABQ Series ABQ03 thru ABQ TR thru 30 TR 9 kw thru 105 kw

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

R4H4. Product Specifications

WJH4 Product Specifications

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

SELF-CONTAINED AIR CONDITIONERS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Call us today! (800)

PRODUCT SPECIFICATIONS

TECHNICAL SPECIFICATIONS

MAC-120HE-03 Air-Cooled Chiller

INSTALLATION INSTRUCTIONS

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Call us today! (800)

Packaged Rooftop Air Conditioners Precedent - Cooling, Gas/Electric, Heat Pump 3-5Ton Standard and High Efficiency 3 Phase Rooftop Units

Transcription:

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1

1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal Energy Efficiency Ratio: 13.5 SEER** Net Cooling Capacity [Btuh]: 24,745** Net Cooling CFM: 800 Evaporator Fan No./Type: Diameter x Width [in]: 9x7 Motor HP : 0.25 Condenser Fan No./Type: Diameter x Width [in]: 10x10 Motor HP : 0.5 Evaporator Coil Face Area: 4.72 [sq ft] Rows/FPI : 2 / 10 Refrigerant Control: TX Valve Condenser Coil Face Area: 5.83 [sq ft] Rows/FPI: 4 / 16 Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/ Independent Refrigerant: Filters - Qty./Size: R-410A Operating Weight [lbs.]: 565 Shipping Weight [lbs.]: 600 2/20x14x2 Condensate Connection: 3 /4 NPT *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F wet bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ARI Standard 210/240-2006 EVAPORATOR FAN PERFORMANCE MODEL SUPPLY 0.2 0.4 0.6 0.8 1.0 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 700 593 0.06 755 0.10 915 0.13 1048 0.17 1175 0.23 - - DSH024 800 629 0.08 777 0.12 914 0.16 1169 0.20 1178 0.25 - - 900 668 0.11 804 0.15 930 0.19 1170 0.24 - - - - NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. CONDENSER FAN PERFORMANCE MODEL OUTDOOR 0.2 0.4 0.6 0.8 RPM BHP RPM BHP RPM BHP RPM BHP DSH024 1600 750 0.29 852 0.35 948 0.42 996 0.46 ELECTRICAL DATA MODEL VOLTAGE COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. "MOP" Max Overcurrent # QTY RLA LRA HP FLA HP FLA AMPACITY Prot. DSH024 208-230/1/60 1 @ 13.5 58.3 0.25 2.6 0.50 4.5 23.98 35 208-230/3/60 1 @ 8.6 55.0 0.25 1.4 0.50 2.2 14.35 20 Johnson Controls maintains a continuous product improvement policy, therefore specifications are subject to change without notice. DSH024 HORIZONTAL UNIT Form YK145.11-PA1 (308) Page 2

2 of 3 DSH HI-EFFICIENCY SERIES HORIZONTAL INDOOR AIR-CONDITIONING SYSTEM GENERAL All models 2-5 tons ship as factory-charged unitized packages. These units include refrigerant line shut-off valves between the condenser and evaporator section, allowing the unit to be field split. All packages/modules are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge corrossion-resistant steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2-lb. density insulation. Service panels are equipped with lifting handles for ease of removal and handling. REFRIGERANT CIRCUIT The 2-5 ton units have a single refrigeration circuit. All models utilize high-efficiency Scroll compressors. Each refrigeration circuit is thoroughly evacuated, and fully charged with R-410A refrigerant before shipment. Internal motor overload protection is provided. Compressors are mounted on rubber isolators to minimize vibration transmission. Each refrigeration circuit includes a thermal expansion valve (with external equalizer), liquid line filter drier, sight glass/moisture indicator, a high refrigerant pressure safety switch, a low refrigerant pressure switch (for compressor protection), and service gauge ports. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to enhanced-surface aluminum fins. Both coils are employed in a draw-thru configuration. The large evaporator coil face area minimizes potential for water blow-off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearing. All blowers are belt-driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. Current overlaod protection is provided on both evaporator and condenser motors (Internal auto-reset overloads on single-phase units, external manual-reset overload on three-phase). A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cutout. A 24-volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2 inch thick medium-efficiency throwaway filters factory installed. MECHANICAL SPECIFICATIONS DSH024 HORIZONTAL UNIT Form YK145.11-PA1 (308) Page 3

DSH024 AND DSH036 DIMENSIONAL DATA 3 of 3 Johnson Controls DIMENSIONAL DATA DSH024 & DSH036 HORIZONTAL UNIT Form YK145.11-PA1 (308) Page 4

1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 36,656* Design CFM: 1,200 Seasonal Energy Efficiency Ratio: 13.2 SEER** Net Cooling Capacity [Btuh]: 35,643** Net Cooling CFM: 1,200 Evaporator Fan No./Type: Diameter x Width [in]: 10x8 Motor HP : 0.33 Condenser Fan No./Type: Diameter x Width [in]: 10x10 Motor HP : 0.75 Evaporator Coil Face Area: 4.72 [sq ft] Rows/FPI : 3 / 12 Refrigerant Control: TX Valve Condenser Coil Face Area: 5.83 [sq ft] Rows/FPI: 4 / 16 Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/ Independent Refrigerant: Filters - Qty./Size: R-410A Operating Weight [lbs.]: 595 Shipping Weight [lbs.]: 630 2/20x14x2 Condensate Connection: 3 / 4 NPT *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F wet bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ARI Standard 210/240-2006 EVAPORATOR FAN PERFORMANCE MODEL SUPPLY 0.2 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1000 598 0.11 722 0.16 835 0.19 930 0.25 1141 0.32 DSH036 1200 727 0.20 831 0.25 929 0.31 972 0.33 - - 1400 747 0.26 844 0.32 - - - - - - NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. CONDENSER FAN PERFORMANCE MODEL OUTDOOR 0.2 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP DSH036 1950 864 0.47 949 0.55 1032 0.63 1112 0.72 - - ELECTRICAL DATA STANDARD MOTOR MODEL VOLTAGE COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. "MOP" Max Overcurrent # QTY RLA LRA HP FLA HP FLA AMPACITY Prot. DSH036 208-230/1/60 1 @ 14.1 77.0 0.33 3.3 0.75 5.5 26.43 40 DSH036 208-230/3/60 1 @ 9.0 71.0 0.33 1.6 0.75 2.6 15.45 20 DSH036 460/3/60 1 @ 5.6 38.0 0.33 0.8 0.75 1.3 9.10 15 DSH036 575/3/60 1 @ 3.8 36.5 0.50 0.9 0.75 1.0 6.63 15 * Units configured for 575 volt are supplied with 0.5 HP evaporator motor. Johnson Controls maintains a continuous product improvement policy, therefore specifications are subject to change without notice. DSH036 HORIZONTAL UNIT Form YK145.11-PA2 (308) Page 5

2 of 3 "DSH" HI-EFFICIENCY SERIES HORIZONTAL INDOOR AIR-CONDITIONING SYSTEM GENERAL All models 2-5 tons ship as factory-charged unitized packages. These units include refrigerant line shut-off valves between the condenser and evaporator section, allowing the unit to be field split. All packages/modules are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge corrossion-resistant steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2-lb. density insulation. Service panels are equipped with lifting handles for ease of removal and handling. REFRIGERANT CIRCUIT The 2-5 ton units have a single refrigeration circuit. All models utilize high-efficiency Scroll compressors. Each refrigeration circuit is thoroughly evacuated, and fully charged with R-410A refrigerant before shipment. Internal motor overload protection is provided. Compressors are mounted on rubber isolators to minimize vibration transmission. Each refrigeration circuit includes a thermal expansion valve (with external equalizer), liquid line filter drier, sight glass/moisture indicator, a high refrigerant pressure safety switch, a low refrigerant pressure switch (for compressor protection), and service gauge ports. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to enhanced-surface aluminum fins. Both coils are employed in a draw-thru configuration. The large evaporator coil face area minimizes potential for water blow-off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearing. All blowers are belt-driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. Current overlaod protection is provided on both evaporator and condenser motors (Internal auto-reset overloads on single-phase units, external manual-reset overload on three-phase). A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cutout. A 24-volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2 inch thick medium-efficiency throwaway filters factory installed. MECHANICAL SPECIFICATIONS DSH036 HORIZONTAL UNIT Form YK145.11-PA2 (308) Page 6

DSH024 AND DSH036 DIMENSIONAL DATA 3 of 3 Johnson Controls DIMENSIONAL DATA DSH024 & DSH036 HORIZONTAL UNIT Form YK145.11-PA2 (308) Page 7

1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 49,493* Design CFM: 1,600 Seasonal Energy Efficiency Ratio: 13.8 SEER** Net Cooling Capacity [Btuh]: 48,522** Net Cooling CFM: 1,600 Evaporator Fan No./Type: Diameter x Width [in]: 12x9 Motor HP : 0.75 Condenser Fan No./Type: Diameter x Width [in]: 12x11 Motor HP : 1.0 Evaporator Coil Face Area: 6.07 [sq ft] Rows/FPI : 4 / 12 Refrigerant Control: TX Valve Condenser Coil Face Area: 7.19 [sq ft] Rows/FPI: 4 / 16 Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/ Independent Refrigerant: Filters - Qty./Size: R-410A Operating Weight [lbs.]: 740 Shipping Weight [lbs.]: 895 2/25x16x2 Condensate Connection: 3 / 4 NPT *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F wet bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ARI Standard 210/240-2006 EVAPORATOR FAN PERFORMANCE MODEL SUPPLY 0.2 0.4 0.6 0.8 1.0 1.2 1.4 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1450 595 0.22 661 0.27 745 0.31 836 0.38 909 0.45 982 0.52 1046 0.61 DSH048 1600 601 0.26 691 0.33 773 0.39 847 0.44 921 0.51 987 0.61 1056 0.67 1800 652 0.35 735 0.42 812 0.50 883 0.57 948 0.64 1018 0.72 - - NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. CONDENSER FAN PERFORMANCE MODEL OUTDOOR 0.2 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP DSH048 2500 645 0.53 749 0.63 812 0.74 872 0.86 945 0.98 ELECTRICAL DATA MODEL VOLTAGE COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. "MOP" Max Overcurrent # QTY RLA LRA HP FLA HP FLA AMPACITY Prot. DSH048 208-230/1/60 1 @ 19.9 109.0 0.75 5.5 1.00 6.3 36.68 50 DSH048 208-230/3/60 1 @ 13.1 83.1 0.75 2.6 1.00 3.3 22.28 35 DSH048 460/3/60 1 @ 6.1 41.0 0.75 1.3 1.00 1.5 10.43 15 DSH048 575/3/60 1 @ 5.0 34.0 0.75 1.0 1.00 1.1 8.35 15 Johnson Controls maintains a continuous product improvement policy, therefore specifications are subject to change without notice. DSH048 HORIZONTAL UNIT Form YK145.11-PA3 (308) Page 8

2 of 3 DSH HI-EFFICIENCY SERIES HORIZONTAL INDOOR AIR-CONDITIONING SYSTEM GENERAL All models 2-5 tons ship as factory-charged unitized packages. These units include refrigerant line shut-off valves between the condenser and evaporator section, allowing the unit to be field split. All packages/modules are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge corrossion-resistant steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2-lb. density insulation. Service panels are equipped with lifting handles for ease of removal and handling. REFRIGERANT CIRCUIT The 2-5 ton units have a single refrigeration circuit. All models utilize high-efficiency Scroll compressors. Each refrigeration circuit is thoroughly evacuated, and fully charged with R-410A refrigerant before shipment. Internal motor overload protection is provided. Compressors are mounted on rubber isolators to minimize vibration transmission. Each refrigeration circuit includes a thermal expansion valve (with external equalizer), liquid line filter drier, sight glass/moisture indicator, a high refrigerant pressure safety switch, a low refrigerant pressure switch (for compressor protection), and service gauge ports. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to enhanced-surface aluminum fins. Both coils are employed in a draw-thru configuration. The large evaporator coil face area minimizes potential for water blow-off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearing. All blowers are belt-driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. Current overlaod protection is provided on both evaporator and condenser motors (Internal auto-reset overloads on single-phase units, external manual-reset overload on three-phase). A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cutout. A 24-volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2 inch thick medium-efficiency throwaway filters factory installed. MECHANICAL SPECIFICATIONS DSH048 HORIZONTAL UNIT Form YK145.11-PA3 (308) Page 9

DSH048 AND DSH060 DIMENSIONAL DATA 3 of 3 Johnson Controls DIMENSIONAL DATA DSH048 & DSH060 HORIZONTAL UNIT Form YK145.11-PA3 (308) Page 10

1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 62,211* Design CFM: 2,000 Seasonal Energy Efficiency Ratio: 13.3 SEER** Net Cooling Capacity [Btuh]: 60,873** Net Cooling CFM: 2,000 Evaporator Fan No./Type: Diameter x Width [in]: 12x9 Motor HP : 1.00 Condenser Fan No./Type: Diameter x Width [in]: 12x11 Motor HP : 1.5 Evaporator Coil Face Area: 6.07 [sq ft] Rows/FPI : 4 / 12 Refrigerant Control: TX Valve Condenser Coil Face Area: 7.19 [sq ft] Rows/FPI: 4 / 16 Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/ Independent Refrigerant: Filters - Qty./Size: R-410A Operating Weight [lbs.]: 860 Shipping Weight [lbs.]: 920 2/25x16x2 Condensate Connection: 3 / 4 NPT *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F wet bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ARI Standard 210/240-2006 EVAPORATOR FAN PERFORMANCE MODEL SUPPLY 0.2 0.4 0.6 0.8 1.0 1.2 1.4 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1800 583 0.30 674 0.37 755 0.44 830 0.52 900 0.59 966 0.69 1037 0.75 DSH060 2000 688 0.45 767 0.53 839 0.61 907 0.69 971 0.77 1029 0.85 1086 0.92 2200 677 0.50 754 0.59 826 0.68 894 0.77 957 0.86 1018 0.95 - - NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. CONDENSER FAN PERFORMANCE MODEL OUTDOOR 0.2 0.4 0.6 0.8 1.0 1.2 1.4 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP DSH060 2900 723 0.79 800 0.84 871 1.07 935 1.20 996 1.55 1057 1.42 - - ELECTRICAL DATA MODEL VOLTAGE COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. "MOP" Max Overcurrent # QTY RLA LRA HP FLA HP FLA AMPACITY Prot. DSH060 208-230/3/60 1 @ 16.0 110.0 1.00 3.3 1.50 4.6 27.90 40 DSH060 460/3/60 1 @ 7.8 52.0 1.00 1.5 1.50 2.1 13.35 20 DSH060 575/3/60 1 @ 5.7 38.9 1.00 1.1 1.50 1.7 9.93 15 Johnson Controls maintains a continuous product improvement policy, therefore specifications are subject to change without notice. DSH060 HORIZONTAL UNIT Form YK145.11-PA4 (308) Page 11

2 of 3 DSH HI-EFFICIENCY SERIES HORIZONTAL INDOOR AIR-CONDITIONING SYSTEM GENERAL All models 2-5 tons ship as factory-charged unitized packages. These units include refrigerant line shut-off valves between the condenser and evaporator section, allowing the unit to be field split. All packages/modules are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge corrossion-resistant steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2-lb. density insulation. Service panels are equipped with lifting handles for ease of removal and handling. REFRIGERANT CIRCUIT The 2-5 ton units have a single refrigeration circuit. All models utilize high-efficiency Scroll compressors. Each refrigeration circuit is thoroughly evacuated, and fully charged with R-410A refrigerant before shipment. Internal motor overload protection is provided. Compressors are mounted on rubber isolators to minimize vibration transmission. Each refrigeration circuit includes a thermal expansion valve (with external equalizer), liquid line filter drier, sight glass/moisture indicator, a high refrigerant pressure safety switch, a low refrigerant pressure switch (for compressor protection), and service gauge ports. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to enhanced-surface aluminum fins. Both coils are employed in a draw-thru configuration. The large evaporator coil face area minimizes potential for water blow-off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearing. All blowers are belt-driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. Current overlaod protection is provided on both evaporator and condenser motors (Internal auto-reset overloads on single-phase units, external manual-reset overload on three-phase). A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cutout. A 24-volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2 inch thick medium-efficiency throwaway filters factory installed. MECHANICAL SPECIFICATIONS DSH060 HORIZONTAL UNIT Form YK145.11-PA4 (308) Page 12

DSH048 AND DSH060 DIMENSIONAL DATA 3 of 3 Johnson Controls DIMENSIONAL DATA DSH048 & DSH060 HORIZONTAL UNIT Form YK145.11-PA4 (308) Page 13