Technical Information OUSTF10

Similar documents
Technical Information OUSAF22

Technical Information OUSAF12

Technical Information OUSAF21

Technical Information OUSAF44

Technical Information OUSTF10

Operating Instructions OUSTF10

Technical Information OUSBT66

Technical Information OUSBT66

Operating Instructions OUSAF12

Condumax CLS16 and CLS16D

Turbimax CUE21 / CUE22

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

Operating Instructions Condumax CLS15/16/21

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Turbimax CUE21 / CUE22

Operating Instructions Indumax CLS54D

PUV, PIR and PFO Series BROCHURE

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

OPTISENS TUR 2000 Technical Datasheet

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

X56 Series Photometric Detectors

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

OMA-300 Process Analyzer

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Laser Distance Sensor Type M Analog-Output

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Instruction Manual. optek-sensors AF56. optek-danulat GmbH Emscherbruchallee Essen

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Application Overview: SmartSwitch

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

OPTIBAR DP 7060 Supplementary Instructions

COMPACT FLAME CONTROLLER CFC 2000

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Model TF56-N Sensor. 1. Using the instruction manual. 2. Returns and disposal. 3. Intended use. 4. Description of the TF56-N sensor

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

SPECTRAL INSTRUMENTATION

Transmitters/Sensors. OLCT Series

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Bristol Babcock Oil Content Monitor "oil in water"

Ultrasonic Level Measurement nivopuls FDU 10 S

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Lamp Supply (Recommended)

PRODUCT DATA SHEET ilh8

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

APPLIED. OMA-406R Rackmount Process Analyzer

Micro/Ultra Filtration System StamoClean CAT 430

Dräger PIR 7200 Toxic Gas Detection Transmitter

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

Dräger Polytron Pulsar 2 Open Path Gas Detector

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Control Panels Switchgear Motors Generators Analysers Rooms/Buildings. Pressurized Enclosure. Static Pressurization. Leakage Compensation (LC)

ATEX Safety Instructions. DYNHRT3MMSS Line Rider

GAS DETECTOR ST400EC PART.NO

manual addendum DELPHI Ex

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

COMPACT FLAME CONTROLLER CFC 1000

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

SIMRAD GD10PE IR GAS DETECTOR

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Continuous Gas Analyzers, in-situ

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Features and Benefits

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

CLARITY II TURBIDIMETER

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Features and Benefits

PROTÉGÉ ZM SINGLE GAS MONITOR

SIMRAD GD10 IR GAS DETECTOR

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Dräger Polytron 5720 IR Detection of carbon dioxide

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

Standard Specifications

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Druck DPI 705/DPI 705 IS Series

Manual Power relay SR853

Quick Start Guide For the

High bay LED lighting fixture

ULTIMA X5000. MSAX5000.com

Optics & Radiometry Laboratory

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

ASSURIX Intrinsically Safe Photoelectronic Sensors

Table of Contents. 1. Mounting Tips... 2

Rosemount 4500 Hygienic Pressure Transmitter. Start

805QS Pressure Switch-Transmitter

Class 1 laser beam sensor safe for your eyes

Transcription:

TI00500C/07/EN/02.16 71316944 Products Solutions Services Technical Information OUSTF10 Optical sensor with the OUA260 flow assembly for the measurement of turbidity and undissolved solids Application The scattered light turbidity sensor is used to measure undissolved solids, emulsions and immiscible media in process liquids. Outgoing goods inspection/purity monitoring Filter control Condensate regulation Turbidity measurement in Breweries Drinking water Brine Leak detection in heat exchanger Your benefits Quality control of products and processes with the precise measurement of minute particle concentrations up to the equivalent of 0 to 200 FTU Formazin or 0 to 200 ppm diatomaceous earth through the use of scattered light detection at an angle of 11 from the excitation beam Operational safety thanks to low-voltage incandescent lamp for long service life and stable measured values Optional broadband NIR filter minimizes color-related measured errors FM- and ATEX-approved lamps for applications in the hazardous area Deployable and durable in numerous applications: Variety of materials and process connections Pyrex window for precise, reproducible performance under industrial conditions, quartz or sapphire window optionally available Hygienic design for high degree of product safety: certified materials and CIP/SIPresistance Can be adapted to process requirements: Optional air purge ports to prevent the formation of condensate on the optical windows

Function and system design Measuring principle Turbidity Turbidity refers to the appearance of a liquid that contains suspended particles. The presence of these particles causes the light to be scattered and absorbed, giving the liquid a turbid, or cloudy, appearance. The amount of light scattered or absorbed in a liquid can be used in a measuring system to determine the degree of turbidity. Scattered light method A focused parallel beam of light is passed through the medium. This beam is known as the transmitted light and is measured by a transmitted light detector. If the medium does not contain any particles, the transmitted light detector detects all the light transmitted by the light source. If there are particles in the medium, the light is scattered in all directions, but primarily in a forward direction. The optical system is designed such that the scattered light is measured at an angle of 11. This angle of measurement ensures that the maximum scattering signal present is detected at the scattered light detector. 1 2 3 4 8 7 6 5 1 Scattered light measurement 1 Light source (lamp) 2 Orifice plates and lenses 3 Scattered light 4 Scattered light detector 5 Transmitted light detector 6 Neutral broadband density filter with anti-reflex coating 7 Medium 8 Broadband NIR filter (780 nm +) A0029413 Measuring system An optical measuring system comprises: Sensor (photometer) OUSTF10 Liquiline CM44P transmitter Cable set CUK80 Assembly to suit the sensor, e.g. OUA260 2 Endress+Hauser

1 2 7 3 6 5 4 2 Example of a measuring system with a photometer sensor 1 pipe 5 Flow assembly OUA260 2 Transmitter CM44P 6 Sensor: light source (lamp) 3 Cable set CUK80 7 Cable set CUK80 4 Sensor: detector Input Measured variable Measuring range Wavelength process absorption 0 to 200 FTU 0 to 200 ppm DE Broadband (VIS and NIR) Broadband filter (780 nm and above) Power supply Electrical connection The sensor is connected to the transmitter using the pre-terminated or labeled cable set CUK80 (for connection to CM44P) or OUK20 (for connection to CVM40). The terminals and labeling may vary depending on the transmitter in use. The cable set must be ordered separately. Endress+Hauser 3

YE YE A B GY RD WH GN GY 3 OUSTF10 connecting cable A Light source (lamp) power supply B Signals of scattered light and transmitted light detector A0028384 CM44P terminal CVM40 terminal Cable color Assignment P+ V1.1 YE (thick) Lamp voltage + S+ V1.3 YE (thin) Detection of lamp voltage + P- V1.2 (thick) Lamp voltage - S- V1.4 (thin) Detection of lamp voltage - A (1) S1.1 RD Scattered light sensor + C(1) S1.2 Scattered light sensor - SH (1) S1.S GY Shield A (2) S2.1 WH Sensor reference + C(2) S2.2 GN Sensor reference - SH (2) S2.S GY Shield Cable length Maximum 100 m (330 ft) Lamp voltage Sensor version Lamp type Lamp voltage [V] OUSATF10-xxxxx Dual beam, collimated incandescent lamp 4.9 ± 0.1 Versions for use in hazardous areas Safety instructions for electrical apparatus in explosion-hazardous areas, XA01403C Connecting the detector using a safety barrier The photometer sensors use silicon photovoltaic cells as detectors which are operated in the current mode. The detectors are intrinsically safe and can be deployed in Zone 1 environments. The safe area is separated from the hazardous area by two safety barriers MTL7760AC. 4 Endress+Hauser

90 (3.54) 105 (4.13) 12.6 (0.5) 4 Safety barrier, dimensions in mm (inch) The safety barrier may only have a very low leak current since the optical signals from the sensor can be in the nanoampere range. Therefore, the sensor cable shield is connected to the ground terminal of the barrier. On delivery, the CUK80 detector cable is permanently wired to the safety barriers. All you have to do is simply connect the individual cable ends to the detector and transmitter. Photometer (Det.) 2x MTL7760ac CM44P RD 3 4 1 2 RD C (1) A (1) SH (1) GN WH 3 4 GY 1 2 GN WH GY C (2) A (2) SH (1) Connecting the hazardous area lamp using a junction box The hazardous area lamp (EXP-1) must be connected to the transmitter using a certified junction box. For versions with FM approval, the junction box is included in the delivery and already preterminated on the lamp side. You simply have to connect the cable of the transmitter (CUK80) to the terminals of the junction box. For versions with ATEX approval, the junction box is not included in the delivery and it and the cable glands required must be provided by the customer at the place of installation. You must connect the cables entirely on your own (CUK80 of transmitter and lamp cable of photometer sensor). Endress+Hauser 5

EXP-1 ATEX II 2G Ex db IIC T5 Gb FM Cl.1, Div. 1, Groups B, C, D YE YE CM44P P+ S+ S- P- PE 27 30 5 Connecting the hazardous area lamp to CM44P using a junction box A0029440 Installation Installation instructions A D B E C 6 Mounting angles. The arrows indicate the direction of medium flow in the pipe. A Preferred mounting angle B Optimum mounting angle C Acceptable mounting angle D Mounting angle to be avoided E Forbidden mounting angle A0028250 6 Endress+Hauser

Environment Ambient temperature range Storage temperature 0 to 55 C (32 to 130 F) -10 to +70 C (+10 to +160 F) Humidity 5 to 95 % Degree of protection IP 65 (NEMA 4) for all optical parts Process Process temperature Process pressure 0 to 90 C (32 to 194 F) continuous Max. 130 C (266 F) for 2 hours Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process connection of the flow assembly Mechanical construction Design, dimensions C A B 7 Sensor module A Dimension of lamp, depends on lamp type, see table B Dimension of detector, see table C Assembly, see Technical Information for assembly A0028306 Lamp type Dimension A in mm (inch) Standard lamp 151.3 (5.96) Detector type Dimension B in mm (inch) OUSTF10 101.6 (4.0) The total length of the sensor module is derived from the lengths of the lamp, the detector and the assembly. The dimensions of the OUA260 assembly are provided in Technical Information, TI00418C. When connecting the sensor cable, make sure you maintain an additional distance of 5 cm (2") on both the lamp side and the detector side of the sensor. Weight 1.225 kg (2.7 lbs.), without flow assembly Endress+Hauser 7

Materials Sensor housing Stainless steel 316L OUA260 assembly Cable connection ends Stainless steel 316, 316L or Kynar or customer-specific material Depends on version Nickel-plated brass Light source Collimated incandescent lamp Lamp operating life: typically 10 000 h Detector UV silicon detectors, hermetically sealed Filter Multilayer narrow-band interference filter Certificates and approvals mark Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the mark. Ex approvals ATEX II 2G Ex db IIC T5 Gb FM Cl.1, Div. 1, Groups B, C, D FDA conformity All non-metal parts in contact with medium, such as rubber and plastic parts, meet the requirements of FDA 21 CFR 177.2600. The plastic and elastomer parts of the sensor in contact with medium have passed the biological reactivity tests according to USP <87> and <88> Class VI. Ordering information Product page www.endress.com/oustf10 Product Configurator On the product page there is a "Configuration" button to the right of the product image. 1. Click this button. The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. To do so, click the "CAD" tab and select the desired file type using dropdown lists. Scope of delivery The scope of delivery consists of the following : sensor Detector and lamp module without flow assembly or Detector and lamp module mounted on OUA260 flow assembly Operating Instructions If the sensor is ordered with a transmitter, the complete measuring system is factory-calibrated and shipped as one package. If you have any questions, please contact your supplier or your local sales center. 8 Endress+Hauser

Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Flow assembly OUA260 Flow assembly for hygienic sensors For sensor installation in pipes Materials: stainless steel 316, 316L or Kynar (other materials available on request) Wide variety of process connections and path lengths available Product Configurator on the product page: www.endress.com/oua260 Technical Information TI00418C Cable CUK80 cable set Pre-terminated and labeled cables for connecting analog photometer sensors Product Configurator on the product page: www.endress.com/cuk80 Endress+Hauser 9

www.addresses.endress.com