INNER SEPARATION CFB. Energy-saving,Efficient, Environmental

Similar documents
FLUIDIZED BED BOILERS

2x58 MW Coal Fired Power Plant at Mauritius

WATER TUBE SOLID FUEL SERIES YOSHIMINE CO., LTD

AUTOMATION OF BOILERS USING LABVIEW

Biomass Energy Systems

Boiler Technical Specifications (2013)

Boiler Division HPS. Triveni Boiler

Product Lists NO.1- WNS horizontal wet back steam boiler

S p u e p r e Pr P e r s e s s u s r u e r Tr T a r p a e p z e i z u i m G i r n i d n i d n i g n Mi M l i l

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

INTEC Engineering GmbH Energy systems

The equipment and materials shall be designed and constructed in accordance with the ASME code section I 2001 ED A02 and Chinese Standards.

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

Anyang Machinery Company Profile

TGM Series Super Pressure Trapezium Mill

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

BIOMASS COMBUSTION BOILERS


Fireplace inserts Water heating fireplace inserts

Additional Information for the Proposed Methodology Energy Saving by Introduction of High Efficiency Once-through Boiler

STEAM & POWER ENGINEERS

Boiler. Fire tube Boiler:

Rental Boiler Specifications (Nebraska Boiler)

Image_engl_08:Image-engl-RZ :55 Uhr Seite 1. INTEC Engineering GmbH Energy systems

Erhitzer_engl_3:Wärmeträger :43 Uhr Seite 1. INTEC Engineering GmbH Thermal oil heaters

2.4 Air Pollution Control and Energy Conservation Measures (Output 4)

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

You can view our archived webinars by going to

INTEC Engineering GmbH Energy systems

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

BENSON Boiler Technology

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

Rozp.UE2015/ kw kw

SONIC CLEANING. for Power- and Heatingplants

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

Product catalogue Pleszew, 2015

Biomass Drum Dryer LMK 2000 Model

Boiler Basics. Design and operation

endless advances for your customers WATER HEATING SOLUTIONS FOR BUILDERS

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

TEPZZ 87_ 6A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION

Deep Rotor VSI Crusher

Solution of I Mid Term Steam Engineering 6ME5A

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Owner s Manual for. PennStoker

Dynamic Simulation of a CFB Boiler System

BONO ENERGIA INDUSTRIAL BOILERS

Removing the moisture contents of coal using solar drying

Discover the Difference

SPECIALIST FOR HEAT-EXCHANGER, FIN TUBES AND BOILER CLEANING SYSTEMS

Köllemann GmbH Page 1 / 16

XUNDA SCIENCE & TECHNOLOGY GROUP CO., LTD

Biomass. Biomass solid fuel boiler range

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

Importance of a Draught Regulator

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

PROFILE AMBICA. Multi Fuel Three Pass, Fire Cum Water Tube Steam Boiler Mfg. Range From 0.5 TPH to 35 TPH Working Pressure up to 50Kg / cm2

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Fireplace inserts Water heating fireplace inserts

PRESENTATION ON PAT TARGET & HEAT RATE IMPROVEMENT

Attention is drawn to the following places, which may be of interest for search:

PESIT-Bangalore South Campus

Fireplace inserts Water heating fireplace inserts Fireplace door

From a renowned company

Super Boiler. > Gas Technology Institute Cleaver-Brooks Inc. May WHO WE ARE Gas Technology Institute

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Cyclone Dust Collection & Separation INSTALLATION & OPERATION MANUAL

2 Newsletter 1/2014. Bosch Industriekessel GmbH Illustrations are only examples Subject to change without notice 1/2014 TT/SLI_de/en_Newsletter_1/14

Trapezium Mill. Reach new height with KEFID. Low loss flexible connection. The production increases 50% Roller linkage supercharger

PC-120 FLATWORK IRONERS. Advanced ironers for superior productivity, efficiency and quality results.

Compound Fertilizer Production Line Project Proposal

anti-condensation valve

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

MTM. Trapezium Mill. Shanghai Shibang Machinery Co., Ltd

Green Energy Engineering, Inc.

Fuel-Fired Vertical Tubeless Boilers

Experimental Study and Analysis of Condenser Performance under Dual Backpressure Operation Mode

BENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow

FUEL-FIRED VERTICAL TUBELESS BOILERS

Guidelines for Preparing for a Temporary Steam Plant

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

Steam Fundamentals. (in heating & processing applications)

Installation, Operation and Maintenance of Central Boiler Plants

Fire Chief Wood/Coal Burning Furnaces

NEW LINE BOILER CONTROLLERS

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

TECHNICAL AND OPERATIONAL DOCUMENTATION

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Wood Chip and Pellet Boilers. Turbomat TM 500.

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Joint Crediting Mechanism Project Design Document Form

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

Wall hung combination

Tuesday, 18 November Video Links. Oil Blow Through 13 November BLOW THROUGH ON BOILER UNIT 6 BEGINS.

Oil and gas solutions. Unicon boiler plants for steam and hot water production

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS

Transcription:

THREE VORTEX INNER SEPARATION CFB BOILER Energy-saving,Efficient, Environmental

SINCE 5 A Hundred Years Centuries Bridge Company profile Zhengzhou Boiler Co., Ltd., founded in 5, has been through 72 years' glorious history, has three subsidiaries and possessing the domes c highest level boiler manufacturing license-a class, also the ASME cer ficates. It is the biggest and most professional industrial boiler and power genera on boiler in Midwest. 72 Years A Manufacturing History License Science and technology help the enterprises become excellent, and the brand becomes its advantages over its compe tors. Over the years, ZBG has cul vated a high-efficiency, high-quality R & D team, holding more than 300 professional and technical personnel, and na onal patents. ZBG has long-term coopera on with more than 10 well-known research ins tu ons, such as Chinese Academy of Sciences, Tsinghua University, Xi'an Jiaotong University, etc. Nowadays, ZBG's selling network has pervaded more than 80 countries and regions, more than 10,000 successful project cases, which makes ZBG become the backbone of boiler industry in china. + National 10000+Customer Patents Cases In 2016, ZBG successfully signed Zheng-luo-xin na onal independent innova on demonstra on zone, and fully started industry 4.0 super smart factory construc on projects. With the requirement of high standard, high output, high-quality construc on, and keep its technology and product development always in the forefront of the industry.

SINCE 5 Product introduction Capacity: 10-410 t/h/14-91mw Design thermal efficiency: 95 89% Applicable fuel: various types of coal, co-firing and biomass fuel Application: thermal power plant, central heating, steam and hot water supply The new technology of tri-whirlpool inner separation is adopted by hot water boilers and power plant boilers, which has a remarkable effect in energysaving. Meanwhile the heat efficiency is increased by 2%~5%. What makes the structure stable is the adoption of membrane wall by the whirlpool type separator of this product, forming the skeleton of separator. The usage of densely covered air cap and multi-hole form by the combustion equipment makes the air flow balanced and the fluidization quality even and stable. The whirlpool type separator is located at the upper side of the combustion chamber. The loop-back device is laid at the left side of the furnace. And in the furnace, all small particles whose terminal speed is lower than that of flue gas will move upwards. After coming into the cyclone type separator, whose particles size is larger than the size of cutting particles diameter will be separated downwards, forming the material seal in the material-returning duct. Then they will be sent to the furnace, through the loop-back device of semi-self-flow, multi-hole and membrane type, mixed with hot-bed materials, for repetition circulating combustion. Sectional Axonometric Drawing

SINCE 5 Product features 1 Membrane wall design, stable structure a. What makes the structure stable is the adoption of membrane wall by the whirlpool type separator of this product, forming the skeleton of separator, so that the separation efficiency is high. The separator is also artfully laid into integration with the combustion chamber and the soot back feeding system, making the boiler structure compact. b. The back feeding system adopts the patent technology of membrane water cooling wall and the loop-back device of semi-self-flow, multi-hole and membrane type, so that the back feeding can be even. 2 Low temperature combustion, low NOx emission The application of low temperature combustion technology can effectively reduce the generation of hazardous gas and the emission of NOx. 3 a. Wear resistance and low failure rate The application of energy-saving low speed fluidization design, multi-grade high temperature separation, inner furnace twice purified separation, new type wear-resistant material, etc., effectively guarantee the improvement of abrasion resistance of different components. b. Very low failure rate, can be continuously operated for a long time, the maximum operation period can be as long as 300 days.

SINCE5 Technical parameters Boilers Model Capacity Pressure Feed Water Fuel Type Model Capacity Pressure Feed Water Fuel Type Unit (t/h) (MPa) ( ) ( ) Unit (t/h) (MPa) ( ) ( ) SHX4--AII 4 SHX30--WI 30 Anthracite SHX6--AII 6 SHX35--AII 35 SHX8--AII SHX8--AII 8 8 Bituminous Coal SHX35--AII SHX35--AII 35 35 SHX10--AII 10 SHX35-/400-AII 35 SHX10--AII 10 SHX40--AII 40 SHX10-/400-AII 10 SHX45--AII 45 SHX12--WI 12 Anthracite SHX50--AII 50 Bituminous Coal SHX15--AII 15 SHX65--AII 65 SHX15--AII 15 SHX75--AII 75 SHX15--AII 15 SHX75-/400-AII 75 SHX20--AII 20 ZG-20/-M 20 SHX20--AII SHX20--AII 20 20 Bituminous Coal ZG-25/-M ZG-35/-M 25 35 SHX20-/400-AII 20 ZG-40/-M 40 SHX25--AII 25 ZG-50/-M 50 SHX25--AII SHX25--AII 25 25 ZG-65/-M ZG-65/5.29-M 65 65 5.29 485 Lignite SHX25-/400-AII 25 ZG-75/-M 75 SHX30--H 30 Lignite Note: The design of the above boiler model fuel is only one of a variety of fuels, each type of boiler can be provided in accordance with the fuel provided by the customer.

SINCE5 Technical parameters Hot Water Boilers Model Capacity Pressure Feed Water Fuel Type Unit (MW) (MPa) ( ) ( ) QXX7-1.0/95/-AII 7 1.0 95 QXX10.5-/115/-AII 10.5 115 Bituminous Coal QXX14-/95/-AII 14 95 QXX14-1.0/115/-H 14 1.0 115 QXX14-/115/-H 14 115 QXX17.5-/115/-H 17.5 115 QXX17.5-//-H 17.5 Lignite QXX29-//-H 29 QXX29-/150/90-H 29 150 90 QXX36-//-AII QXX36-//-AII 36 36 Bituminous Coal QXX46-//-H 46 QXX46-//-H 46 QXX58-//-H QXX58-//-H 58 58 Lignite QXX64-//-H 64 QXX64-/150/90-H 64 150 90 Note: The design of the above boiler model fuel is only one of a variety of fuels, each type of boiler can be provided in accordance with the fuel provided by the customer.

SINCE5 Boiler lchnography 20t/h CFB Boiler CFB Boiler

M M SINCE5 Boiler system Canop Coal Bunker Deaerator Transporting Coal Seam Steel Bunker Main Pipe Turbine Generators Room Control Room Pipe Layer Water Pump Room Distribution Room A B C D Turbine Generators Cylinder Feed Pump Feeder Blower Dust Collector Induced Draft Fan Chimney Inter Circulating Fluidized Bed Boilers Desulfurizing Tower

SINCE 5 Relevant cases 40 Tons CFB Boiler in Xiangfen Hongyuan 55 Tons CFB Boiler Project in Zigong Sichuan 25 Tons CFB Boiler for Meixian Xingzhou 15FKS Kaisheng CFB Boiler Project in Outer Mongolia

SINCE5 Service idea All of our work always focus on one goal: To provide customers with the most valuable boilers and services. In ZBG, we promise to all users: Free maintenance within 12 months from shipment Providing technical consultation and reply with in 30 minutes Dispatching engineers within 24 hours Accepting service requests in 365 days a year We provide all customers with original standard parts and " processing with supplied drawings" to meet the practical needs of customers, so that all customers' after-sales without worry.

United Pragmatic Efficient Innovative Add: NO. 88 Science Avenue, National High-Tech industrial Development Zone, Zhengzhou, China. Tel: 0086-371-86062323 Fax: 0086-371-67838093 E-mail: sales@zgboilers.com