OOH740-A9-Ex Multisensor fire detector

Similar documents
OOH740-A9-Ex Multi-sensor fire detector

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-9, FDOOT241-A, FDO241, FDT241

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT221, FDO221, FDT221

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OOH740, OOHC740 Automatic fire detectors

OH720, OP720, HI720, HI722

FDCL221-Ex Line adapter (Ex)

OH110, OP110, HI110 Automatic fire detectors

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DF1101-Ex Infrared flame detector

FDCIO223 (ES 45) Transponder

Input module, input/output module

Input module, input/output modules

ASA linear smoke detector

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

DT1101A / DT1102A / DO110xA Automatic fire detectors

Multi line separator module

FDBZ290 Air sampling smoke detection kit

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDBZ290 Air sampling smoke detection kit

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FC724 Fire control panel

FC724 Fire control panel

FDCL221-M Multi line separator module

FC722 Fire control panel

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FC723 Fire control panel

Output module (230 V)

DF1151-Ex Infrared flame detector

DC1192 Input /Output module

Fire & Security Products. Siemens Building Technologies Group

FDOOT241-A9-Ex Automatic fire detector Technical Manual

Fire control panels FC726 FC726-XA

Mimic display driver, LED ribbon cable

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Fire control panels FC360

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

FC2020 Fire control panel

FDCW241 Radio gateway Mounting

FS720 Fire detection system (marine) Technical Manual

Radio fire detection system

FC2040. Fire control panel. Sinteso. FS20 series, MP6

SWING radio fire detection system

FD20 Sinteso Detector system

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Synova TM product catalog.

FDA241, FDA221 Siemens ASD

FC722 Fire control panel

Inductive slot sensor

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Installation and Operating Instruction

DM1131 / DM1133 / DM1134 Manual call points

Intelligent Detection Devices

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

IECEx Certificate of Conformity

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Declaration of conformity

AND INSTALLATION MANUAL

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Test units and accessories

Cerberus PRO enjoy protecting A comprehensive fire protection system

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

SET-2000 Oil/Sludge 12 VDC

FDBZ290 Air sampling smoke detection kit Technical Manual

4) Intrinsic Safety Certification

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Cerberus ECO. Fire Safety Products and Accessories. Product Catalogue. siemens.com/buildingtechnologies

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Smoke Detector Testing

Cerberus FIT conventional system

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Test units and accessories

Test units and accessories

FDM273 Radio manual call point Mounting

FDL241-9 Linear smoke detector Mounting Commissioning

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Technical Data. Dimensions

Fire safety products and accessories siemens.com/cerberus

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

FDA241, FDA221 Siemens ASD

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Answers for infrastructure. Cerberus PRO enjoy protecting

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Desigo Fire Safety intelligent detectors for complete safety

OPTIBAR P 1010/2010 C Supplementary instructions

Instrumentation Products and Applications

IECEx Certificate of Conformity

XC10 Extinguishing control panels

FDCL221 Line separator

Transcription:

OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled detection behavior Early and reliable detection when fires occur Highly developed immunity to deceptive phenomena Redundant sensor system Suitable for wind speeds of 1 to 20 m/s Prepared for future requirements thanks to its programmability Communication via C-NET-Ex (addressed individually) Address automatically issued during commissioning Control Products and Systems

Properties Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Features Resistant to environment and interfering influences such as dust, fibers, insects, moisture, extreme temperatures, electromagnetic interference, corrosive vapors, vibration, artificial aerosols, and atypical fire phenomena Shock resistant, protection against sabotage Signal processing with ASAtechnology (Advanced Signal Analysis) Time and process-dependent detection behavior High degree of immunity to faults in power electronics Protected electronics, high-quality components Sophisticated sensors and electronic monitoring Redundant, high-quality sensor system Integrated alarm indicator (AI), 360 visibility OOH740-A9-Ex neural fire detector, ASA Function Functions according to the scattered light principle with two sensors, optical forward and backward scattering Opto-electronic measuring chamber which obstructs disruptive extraneous light but provides excellent detection of both light and dark smoke particles Two additional heat sensors increase the fire detector's immunity to deceptive phenomena Can be set as a multisensor smoke detector, smoke detector, or heat detector by the software Selectable detection behavior thanks to application-specific ASA parameter sets Multi-protocol: Collective/GMT (Cerberus/Siemens), SynoLINE300 C-NET-Ex Use For early detection of flaming fires of solid and liquid substances as well as of smoldering fires For early and reliable fire detection in an environment with deceptive phenomena Can be used either addressed or collectively Efficiency on-site Exchange the detector with detector exchanger FDUD291 without resetting the parameters Exchange the detector with detector exchanger FDUD291 without a ladder at heights up to 8 m 2

Installation Installation in potentially explosive areas Easy mounting Base with stilts for surface-mounted and recess-mounted supply lines Flat base for flush mounting, only for recess-mounted supply lines Extra-long mounting slits allow existing drill holes from other systems to be reused A large opening in the detector base makes it easy to feed the cables through The detector can be screwed into the base easily either manually or using a detector exchanger The OOH740-A9-Ex fire detector is designed in ignition protection category 'intrinsic safety' Ex i Standards IEC 60079-0 and IEC 60079-11 provide a basis Specific national requirements always apply when creating installations in areas at risk of explosion. Addressed operation (C-NET/C-NET-Ex) The safety barrier FDCL221-Ex ensures electrical isolation of the potentially explosive areas and the areas not at risk. Area not at risk of explosion Area at risk of explosion C-NET C-NET-Ex C-NET 1 FDCL221-Ex line adapter (Ex) 2 Manual call point FDM223-Ex 3 Multisensor fire detector OOH740-A9-Ex 4 Alarm indicator FDAI92-Ex 5 Alarm indicator FDAI93-Ex 3

Collective Ex installation The input/output module DC1192/FDCIO223 with downstream safety barrier SB3 ensures electrical isolation of the potentially explosive areas and areas not at risk. Area not at risk of explosion Area at risk of explosion 1 2 3 4 5 6 7 8 9 10 Input/output module DC1192 Transponder FDCIO223 Zone module FDCI723 Equipotential bonding ground Alarm indicator FDAI92-Ex / FDAI93-Ex End-of-line EOL22(Ex) in the last detector Heat detector DT1101A/02A-Ex Multisensor fire detector OOH740-A9-Ex Smoke detector DO1101A-Ex Safety barrier SB3 Dimensions of the detector with base up to Ø6 mm possible for surface-mounted cable entry with base FDB221, FDB201, or FDB202 with base FDB222 for flush mounting, only for recess-mounted cable entry 4

Technical data Dimensions (Ø x H) 100 x 45.7 mm Operating temperature -25 +70 C Storage temperature -30 +75 C Air humidity Communication protocol 95 % rel. (short-term moisture condensation permitted) C-NET or collective Ex Color ~RAL 9010, pure white Protection category according to EN 60529 Collective system compatibility C-NET system compatibility IP43 IP44 with sealing kit FDBZ295 FC10, XC10, FC330A, FC700A FS720 Characteristics Ui 28 V Ii 100 ma Pi 700 mw Li negligible Ci < 0.2 nf Operating current (quiescent) 200 280 µa Ext. Alarm indicator (AI) Uo 14.2 V Io 480 ma Po 195 mw Lo < 100 µh Co < 38 nf Only for connecting passive, external alarm indicators to negligibly small inductivities and capacities. Ex classification IECEx scheme Ex ia IIC T4 Ga, Ta = -35 C +70 C 94/9/EC (ATEX Directive) II 1 G Ex ia IIC T4 Ga, Ta = -35 C +70 C Ex approvals - EC-type examination certificate BVS 12 ATEX E 087 X - IECEx BVS 12.0076 X EN 54 approvals - VdS G214047 DNV GL (Marine) 45 246-16 HH 5

Details for ordering Type Art. no. Designation Weight OOH740-A9-Ex S54329-F8-A1 Multisensor fire detector 0.106 kg Accessories FDBZ295 S54319-F10-A1 Sealing kit 0.062 kg You will find additional information in the following documents: Equipment overview, doc no. A6V10225323 For system compatibility, see list of compatibility, doc no. A6V10229261 Fire alarm signal in areas at risk of explosion, doc no. 001204 Planning, mounting/installation, commissioning, maintenance/servicing of fire detection installations FS20 and FS720 in potentially explosive areas, doc no. A6V10324618 Safety barrier SB3 mounting instructions; doc no. 1227 Line adapter (Ex) FDCL221-Ex, doc no. A6V10349349 OOH740-A9-Ex technical manual, doc no. A6V10367521 Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. A6V10371417_g_en_-- Manual FD720 Edition 2016-05-23 Register 8