ESFR sprinkler system

Similar documents
Spray sprinkler system

FIRE PROTECTION FOR NON-STORAGE OCCUPANCIES WITH HIGH CEILING CLEARANCES

Sprinkler Solutions for Storage Applications

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

An experimental study of the impact of tunnel suppression on tunnel ventilation

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Box-in-Box Cold Storage Fire Protection Options

Storage Protection Using Horizontal Barriers and Large K-Factor, Extended Coverage In-Rack Sprinklers

Full-scale test of fire detection in a facade using heat detection cable and flame detector

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

Sprinkler Identification Numbers

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

The Loss prevention Council. Phase 1 report

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

Evaluation of Protection for Plastic Containers Using Sprinkler Systems with 1.0% AFFF and Plain Water

Indicative hoarding fire experiment. Prepared for: London Fire Brigade. 21 May 2014 Client report number

STORAGE FIRE PROTECTION SPRINKLERS

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

High challenge warehouse case study Summary

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Today's Topics & Sustainability Themes

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

Performance Report 2009 Chimfex

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

SAFETY FIRST INTERNATIONAL

The Effect of Large Orifice Sprinklers on High-Challenge Fires

Warehouse Protection of Exposed Expanded Group-A Plastics with Electronic Sprinkler Technology

Foam Products ENGLISH

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Sprinklers in Combustible Concealed Spaces

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

High Ceiling Protection

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler Heads Revised

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

Fire in a refrigerated warehouse 19 August 1997 Le Havre (Seine-Maritime) France

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

ROLL PAPER STORAGE. Table of Contents

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

SOUTHWEST RESEARCH INSTITUTE

UNDERWRITERS 7 LABORATORIES OF CANADA

TECHNICAL DATA NOTICE

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

WHE 2.24 / WHE 2.24 FF

Case Study 1 Underground Car Park

TECHNICAL DATA OBSOLETE

esfr dry pendent sprinkler Vk502 (k14.0)

Hazardous Material Safety Program

JET-X HIGH-EXPANSION FOAM GENERATORS Data/Specifications

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Tire Storage. Michigan Fire Inspectors Society Fall Conference

Early Suppression Fast Response Sprinklers and Obstructions

Osceola County Department of Fire Rescue and Emergency Medical Services

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

Case Study of Underground Car Park. Team Japan

Large-scale fire sprinkler tests with the AutoStore compact storage system

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

esfr dry pendent sprinkler Vk501 (k14.0)

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Chapter 17, Initiating Devices

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Test Report: ICL/H18/9039 Rev 1

ANTIFREEZE AND AUTOMATIC FIRE SPRINKLERS UPDATE. Presented by: Jerry Schultz The FPI Consortium, Inc. July 28, 2017

esfr pendent sprinkler vk510 (k25.2)

Fire in an archive warehouse January 28 th 2002 Roye [Somme] France

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

esfr pendent sprinkler vk510 (k25.2)

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Second Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement

Extended Coverage Sidewall Sprinklers

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Possible Use of FSE. in the Context of French. Regulation

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

Building Research Note

The Italian National Guidelines for the fire safety of façades

OPEN SPRINKLER SYSTEM

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Transcription:

Protection, prevention and environmental impact of fire in a tire storage SNCP experience feedback report ESFR sprinkler system Recommendations on fire protection in tyre storage facilities using ESFR sprinkler system 6 Centre Français du Caoutchouc et des Polymères industriels 6, RUE AUBER 9448 VITRY SUR SEINE CEDEX TEL : 1 49 6 7 7 FAX : 1 4 21 3 N SIRET : 78437483 APE : 911 A SYNDICAT PROFESSIONNEL 3394 LOI DU 21 MARS 1884 Mél : info@lecaoutchouc.com - Internet : www.lecaoutchouc.com

Summary sheet Automatic fire ignition and extinguishing tests in tyre storage facilities. on-tread and laced configurations storage height up to 8.7 m ceiling height up to 12 m fire protection system using K2 ESFR sprinklers Lessons learnt from the tests tyres do not ignite easily without an accelerating agent pyrolysis is slow to set in the heat release rate is low for the first 3 minutes, then increases rapidly the fire's kinetics, development and heat release rate are similar for both types of storage configurations: on tread and laced the automatic extinguishing system acts in the same way on both types of storage the first ESFR sprinkler head opens before the flames emerge from the stock clearance, between 1.2 m and 4.2 m, has no measurable effect the fire does not spread to another island 2.4 m away with the sprinklers operating Copyright SNCP december 27 Page 2

K2 ESFR sprinkler heads protect: a storage height of 7.4 m in control mode, with a density of 2 l/min/m 2 at ground level (head pressure of 1.7 bar) a storage height of 7.4 m in suppression mode, with a density of 67 l/min/m 2 at ground level (head pressure of 2.8 bar) a storage height of 8.7 m in suppression mode, with a density of 91 l/min/m 2 at ground level (head pressure of.2 bar) the quantity of burnt tyres is low, around 6 kg in control mode, less than 1 kg in suppression mode the quantity of smoke emitted is low, visibility in the building remains sufficient for fire-fighting operations Since the quantity of burnt tyres is small, the potential impact is limited to the inside of the building. Atmospheric emissions have no impact on the environment or the population. Similarly, pollutants in the extinguishing water are negligible and below the daily limits authorised for industrial facilities. the temperature of framework elements is under 1 C and does not exceed 31 C in suppression mode Recommendations For new warehouses with up to 12 m of storage height, with K2 ESFR sprinkler systems: both types of storage can be used: on tread and laced a density of 67 l/min/m 2 at ground level (head pressure of 2.8 bar) protects a tyre storage configuration up to 7.4 m high, in suppression mode a density of 91 l/min/m 2 at ground level (head pressure of.2 bar) protects a tyre storage configuration up to 8.7 m high, in suppression mode Copyright SNCP december 27 Page 3

Experience feedback report Réf : SNCP/REX-INC/6-27 Automatic fire ignition and extinguishing tests in tyre storage facilities. 1. Introduction Under the auspices of SNCP, a study group of tyre manufacturing, logistics and protection professionals met to further industry knowledge of fire hazard management in tyre storage facilities, specifically the performance of automatic water-based sprinkler systems. The members of this partnership the SNCP, Bridgestone, Goodyear-Dunlop, Hankook and Michelin, the logistic groups Afilog and Aliapur, and the manufacturer Tyco Fire & Building Products have put together ambitious specifications for significant extinguishing tests. These tests cover various configurations for storing tyres and various sprinkler types and characteristics. The Centre National de Prévention et Protection (CNPP Entreprise) in Vernon then performed the tests. The purpose of this experience feedback report is to present the main lessons learnt from analyses of the test results. Copyright SNCP december 27 Page 4

2. Test facilities 2.1 Test hall The tests were conducted at the CNPP in test hall no. 3, measuring 3 m long, 2 m wide and 24 m high. The test hall has metal walls and structural elements. Each of the hall's 4 facades is equipped with a rolling shutter (width: 4 m/height: 4. m) generally kept open at 4 cm from the ground to simulate air intake in a warehouse configuration. The roof of the test hall is equipped with a smoke extraction system: four.2 m² louvered lateral openings, kept closed for the tests 1 central 2 m² opening, kept 1% open depending on the test Test hall ground is equipped with a 64m² fire resistant material platform located in the middle of the hall. 2.2 Extinguishing system A moveable 18 m x 1 m metal ceiling with an adjustable height of 9 12 m was installed in the centre of the test hall. The ceiling was equipped with a 3 m x 3 m main pipework grid fitted with 2 pendant DN6 drops on which model TY 9226 ESFR, K2, RTI 26, 74 C, sprinklers were installed. Main pipework is completed at its end with a 4 pendant antenna for warning sprinklers installation (same sprinklers used in test with reduced opening). 2.3 Tyre storage configurations There were 4 to levels of tyre storage (7.4 m or 8.7 m high), covering a floor area of 12 to 14 pallets depending on the test. The tyres were arranged on tread and/or laced. Copyright SNCP december 27 Page

Two pallet designs was used, depending on the test: Monoblock pallet E4 folding pallet Outside width between tyres 1.3 m to 1.43 m 1.2 m to 1.3 m Inside width between uprights 1.24 m 1. m Outside length 1.93 m 2.3 m Inside length between uprights 1.74 m 2.2 m Height 1. m 2.2 m Spacing between pallets, measured at the base in both directions, varies from 1 to 27 cm depending on the tests (x in the diagram). x 2.4 Ignition system The fire ignition system consisted of cotton pellets, each soaked in 32 ml of fuel and enclosed in a plastic film bag (L = 1 cm, = 8 cm). Two igniters, each consisting of two pellets, were arranged at ground level at the intersection between pallets A2, A3, B2 and B3, in the free space between the pallets and positioned against the tyres. 1 2 3 4 D C B A 2,4 m 2. Instrumentation Stockage témoin 1 thermocouple per sprinkler head to detect its operating temperature 14 thermocouples in the storage 1 thermocouple at the top of the control storage area 2 thermocouples above the ignition point, close to the ceiling thermocouples in a control angle iron placed against the ceiling above the ignition point thermocouples in the roof s structural elements above the ceiling Water flow rate and pressure 2.6 Video monitoring Each test was filmed by video cameras installed around the storage area. Copyright SNCP december 27 Page 6

Appendices 1 to : The appendices contain additional data for each of the five ESFR sprinkler tests: tables of parameters and results diagrams of open sprinkler heads and their opening times relative to ignition time superimposed curves for temperature and water discharge Appendix 1 Test CNPP21 (VG7) Tyre storage Tyre configuration On tread Number of tyres per pallet 36 Nominal storage height 7.4 m Monoblock pallet levels Nb of pallets on the ground 14 Total number of pallets 7 Spacing between pallets x = cm Number of tyres stored 2 2 Storage configuration below ceiling Ignition point between heads 13 and 14 Extinguishing system configuration Ceiling height 9 m Sprinkler head height (deflectors) Clearance between deflectors and top of storage 1.2 m Head (deflector) to ceiling clearance 8.7 m.3 m Sprinkler type K2 ESFR Sprinkler K-factor K = 363 Sprinkler RTI 26 Operating temperature 74 C Sprinkler spacing 3 m x 3 m Sprinkler SIN TY 9226 Nominal sprinkler density 42 l.m -2.min -1 Sprinkler pressure 1.1 bar Nominal flow per sprinkler 378 l/min Extinguishing agent Water only Test conditions Test date 21/6/2 Outside temperature 18 C Air intake Smoke extraction Conditions for ending test Natural; only north door open to 3 m from ground Natural, central vent 1% open Avg temp at angle iron exceeds 638 C One of the ceiling structure temperatures exceeds 3 C Test results First sprinkler opened 2 min 38 s Total no. of sprinklers open 7 Last sprinkler opened 29 min 2 s Max temp cm under ceiling 23 C Damage to test tyres No Max temp 3 cm under ceiling 83 C Avg max angle iron temp 9 C Time max temp attained 21 min 2 s Max ceiling framework temp 41 C Time max temp attained 22 min s Total no. of pallets damaged 22 --- --- Equivalent no. of tyres burnt Extinguishing efficiency 61 tyres or 2. % of test stock Control mode achieved Copyright SNCP december 27 Page 7

. Max =38 C Max= C Max=7 C Max=36 C Nord Max=6 C Max=7 C 1 2 3 4 b Max =39 C Max=46 C Max=91 C Max=66 C Max= C Max=7 C 6 7 8 9 1 1b 4 min 3 s 29 min 2 s Max =42 C Max=43 C Max=78 C Max=69 C Max=67 C Max=6 C 11 12 13 14 1 1b Max =4 C Max=63 C 2 min 38 s Max=93 C 3 min s Max=96 C 12 min 2 s Max=77 C Max=63 C 16 17 18 19 2 2b 3 min 1 s 3 min 14 s Sprinkler non ouvert North - (2) Unopened sprinklers (3) Open sprinklers Sprinkler ouvert (2) (3) Temperatures / Open sprinkler heads Températures / Têtes sprinkler ouvertes 2 2 Cornière Avg angle moyenne iron temp 3 3 cm cm sous below plafond ceiling cm cm sous below plafond ceiling Nbre Total total no. têtes open ouvertes heads Nbre No. têtes open ouvertes discharging débitant 1 9 8 7 Température ( C) 1 1 3 min : Pompiers en intervention 6 4 3 2 1 1 1 2 2 3 3 4 4 Temps (min) (2) 3 min : Operation by fire fighters - (2) Time (min) Copyright SNCP december 27 Page 8

Appendix 2 Test CNPP22 (VG1) Tyre storage Tyre configuration Laced Number of tyres per pallet 4 to 48 Nominal storage height 7.4 m Monoblock pallet levels Nb of pallets on the ground 14 Total number of pallets 7 Spacing between pallets x = cm Number of tyres stored 2 92 Storage configuration below ceiling Ignition point between heads 13 and 14 Extinguishing system configuration Ceiling height 9 m Sprinkler head height (deflectors) Clearance between deflectors and top of storage 1.2 m Head (deflector) to ceiling clearance 8.7 m.3 m Sprinkler type K2 ESFR Sprinkler K-factor K = 363 Sprinkler RTI 26 Operating temperature 74 C Sprinkler spacing 3 m x 3 m Sprinkler SIN TY 9226 Nominal sprinkler density 2 l.m -2.min -1 then 67 Sprinkler pressure 1.7 bar then 2.8 Nominal flow per sprinkler 468 l/min Extinguishing agent Water only Test conditions Test date 29/6/2 Outside temperature 19 C Air intake Smoke extraction Conditions for ending test Natural; 4 facade doors open to 4 cm above ground Natural, central vent 1% open Avg temp at angle iron exceeds 638 C One of the ceiling structure temperatures exceeds 3 C Test results First sprinkler opened 3 min 4 s Total no. of sprinklers open 6 Last sprinkler opened 6 min 24 s Max temp cm under ceiling 193 C Damage to test tyres No Max temp 3 cm under ceiling 227 C Avg max angle iron temp 73 C Time max temp attained 7 min 1 s Max ceiling framework temp 3 C Time max temp attained 14 min 2 s Total no. of pallets damaged 22 --- --- Equivalent no. of tyres burnt Extinguishing efficiency 7 tyres or 2 % of test stock Control mode achieved with 2 l/min/m 2 Suppression mode achieved with 67 l/min/m 2 Copyright SNCP december 27 Page 9

. Nord Max =4 C Max=47 C Max=62 C Max=7 C Max=8 C Max=43 C 1 2 3 4 b 6 min 19 s Max =4 C Max=6 C Max=74 C Max=69 C Max=42 C Max=4 C 6 7 8 9 1 1b 6 min 24 s Max =46 C Max=42 C Max=4 C Max=66 C Max=47 C Max=38 C 11 12 13 14 1 1b 4 min s 4 min s Max =39 C Max=49 C Max=4 C Max= C Max=39 C Max=49 C 16 17 18 19 2 2b 3 min 4 s 3 min 8 s Sprinkler non ouvert (2) Sprinkler ouvert (3) North - (2) Unopened sprinklers (3) Open sprinklers Temperatures / Open sprinkler heads Températures / Têtes sprinkler ouvertes 2 1 18 16 14 Cornière Avg angle moyenne iron temp 3 cm below ceiling 3 cm sous plafond cm cm sous below plafond ceiling Nbre Total total no. têtes open ouvertes heads Nbre No. têtes open ouvertes discharging débitant heads 9 8 7 Température ( C) 12 1 8 6 4 6 4 Taux d'application initial + 3 % : 69 l.m -2.min -1 Réseau secours pour exercice (2) 3 2 2 1 1 1 2 2 3 3 4 4 6 Temps (min) Initial sprinkler density + 3 % : 69 l.m -2.min -1 - (2)Emergency supply for test (3) Time (min) (3) Copyright SNCP december 27 Page 1

Appendix 3 Test CNPP23 (VG7-) Tyre storage Tyre configuration On tread Number of tyres per pallet 32 to 36 Nominal storage height 7.4 m Monoblock pallet levels Nb of pallets on the ground 14 Total number of pallets 7 Spacing between pallets x = cm Number of tyres stored 2 28 Storage configuration below ceiling Ignition point between heads 13 and 14 Extinguishing system configuration Ceiling height 1. m Sprinkler head height (deflectors) Clearance between deflectors and top of storage 2.7 m Head (deflector) to ceiling clearance 1.2 m.3 m Sprinkler type K2 ESFR Sprinkler K-factor K = 363 Sprinkler RTI 26 Operating temperature 74 C Sprinkler spacing 3 m x 3 m Sprinkler SIN TY 9226 Nominal sprinkler density 67 l.m -2.min -1 Sprinkler pressure 2.8 bar Nominal flow per sprinkler 63 l/min Extinguishing agent Water only Test conditions Test date 6/1/2 Outside temperature 13 C Air intake Smoke extraction Conditions for ending test Natural; 4 facade doors open to cm above ground Natural, central vent % open Avg temp at angle iron exceeds 4 C One of the ceiling structure temperatures exceeds 3 C Test results First sprinkler opened 4 min 27 s Total no. of sprinklers open 2 Last sprinkler opened 4 min 2 s Max temp cm under ceiling 87 C Damage to test tyres No Max temp 3 cm under ceiling 6 C Avg max angle iron temp 31 C Time max temp attained 4 min 2 s Max ceiling framework temp 24 C Time max temp attained --- Total no. of pallets damaged 1 --- --- Equivalent no. of tyres burnt Extinguishing efficiency 14 tyres or.7 % of test stock Suppression mode achieved Copyright SNCP december 27 Page 11

. Max =39 C Max=4 C Max=47 C Max= C Nord Max=38 C Max=29 C 1 2 3 4 b Max =41 C Max=44 C Max=8 C Max=62 C Max=38 C Max=3 C 6 7 8 9 1 1b Max =49 C Max=73 C Max=67 C Max=6 C Max=49 C Max=3 C 11 12 13 14 1 1b Max = C Max= C 4 min 2 s Max=49 C 4 min 27 s Max=32 C Max=38 C Max=42 C 16 17 18 19 2 2b Sprinkler non ouvert (2) Sprinkler ouvert (3) North - (2) Unopened sprinklers (3) Open sprinklers Temperatures / Open sprinkler heads Températures / Têtes sprinkler ouvertes 1 9 8 Cornière Avg angle moyenne iron temp 3 3 cm cm sous below plafond ceiling cm cm sous below plafond ceiling 4 7 Nbre Total total no. têtes open ouvertes heads Nbre No. têtes open ouvertes discharging débitant Température ( C) 6 4 3 2 3 2 1 1 1 1 2 2 3 3 4 4 6 6 7 7 8 8 9 Time (min) Temps (min) Copyright SNCP december 27 Page 12

Appendix 4 Test CNPP24 (VG8) Tyre storage Tyre configuration Mixed Number of tyres per pallet 32 to 4 Nominal storage height 7.4 m Monoblock pallet levels Nb of pallets on the ground 14 Total number of pallets 7 Spacing between pallets x = cm Number of tyres stored 2 444 Storage configuration below ceiling Ignition point under head 13 Extinguishing system configuration Ceiling height 12 m Sprinkler head height (deflectors) Clearance between deflectors and top of storage 4.2 m Head (deflector) to ceiling clearance 11.7 m.3 m Sprinkler type K2 ESFR Sprinkler K-factor K = 363 Sprinkler RTI 26 Operating temperature 74 C Sprinkler spacing 3 m x 3 m Sprinkler SIN TY 9226 Nominal sprinkler density 67 l.m -2.min -1 Sprinkler pressure 2.8 bar Nominal flow per sprinkler 63 l/min Extinguishing agent Water only Test conditions Test date 13/1/2 Outside temperature 21 C Air intake Smoke extraction Conditions for ending test Natural; 4 facade doors open to cm above ground Natural, central vent % open Avg temp at angle iron exceeds 4 C One of the ceiling structure temperatures exceeds 3 C Test results First sprinkler opened 3 min 7 s Total no. of sprinklers open 1 Last sprinkler opened 3 min 7 s Max temp cm under ceiling 83 C Damage to test tyres No Max temp 3 cm under ceiling 73 C Avg max angle iron temp 26 C Time max temp attained 3 min 3 s Max ceiling framework temp 22 C Time max temp attained --- Total no. of pallets damaged 7 --- --- Equivalent no. of tyres burnt Extinguishing efficiency 6 tyres or.3 % of test stock Suppression mode achieved Copyright SNCP december 27 Page 13

. Nord Max =3 C Max=34 C Max=37 C Max=28 C Max=3 C Max=28 C 1 2 3 4 b Max =29 C Max=3 C Max=41 C Max=41 C Max=3 C Max=28 C 6 7 8 9 1 1b Max =29 C Max=3 C Max=7 C Max=34 C Max=28 C Max=2 C 11 12 13 14 1 1b 3 min 7 s Max =28 C Max=31 C Max= C Max=3 C Max=28 C Max=27 C 16 17 18 19 2 2b Sprinklers non ouverts (2) Sprinklers ouverts (3) North - (2) Unopened sprinklers (3) Open sprinklers Temperatures / Open sprinkler heads Températures / Têtes sprinkler ouvertes 1 9 Cornière Avg angle moyenne iron temp 8 3 3 cm cm sous below le plafond ceiling cm cm sous below le plafond ceiling 4 7 Nbre Total total no. têtes open ouvertes heads Température ( C) 6 4 Nbre No. têtes open ouvertes discharging débitant heads 3 2 3 2 1 1 1 1 2 2 3 3 4 4 6 Time (min) Temps (min) Copyright SNCP december 27 Page 14

Appendix Test CNPP2 (VG11) Tyre storage Tyre configuration Laced Number of tyres per pallet 6 to 96 Nominal storage height 8.7 m E4 pallet levels 4 Nb of pallets on the ground 12 Total number of pallets 48 Spacing between pallets x = 1 27 cm Number of tyres stored 3 799 Storage configuration below ceiling Ignition point under head 13 Extinguishing system configuration Ceiling height 12 m Sprinkler head height (deflectors) Clearance between deflectors and top of storage 2.9 m Head (deflector) to ceiling clearance 11.7 m.3 m Sprinkler type K2 ESFR Sprinkler K-factor K = 363 Sprinkler RTI 26 Operating temperature 74 C Sprinkler spacing 3 m x 3 m Sprinkler SIN TY 9226 Nominal sprinkler density 91 l.m -2.min -1 Sprinkler pressure.2 bar Nominal flow per sprinkler 819 l/min Extinguishing agent Water only Test conditions Test date 2/1/2 Outside temperature 17 C Air intake Smoke extraction Conditions for ending test Natural; 4 facade doors open to cm above ground Natural, central vent % open Avg temp at angle iron exceeds 4 C One of the ceiling structure temperatures exceeds 3 C Test results First sprinkler opened 2 min 9 s Total no. of sprinklers open 1 Last sprinkler opened 2 min 9 s Max temp cm under ceiling 87 C Damage to test tyres No Max temp 3 cm under ceiling 82 C Avg max angle iron temp 23 C Time max temp attained 3 min 2 s Max ceiling framework temp 19 C Time max temp attained --- Total no. of pallets damaged 6 --- --- Equivalent no. of tyres burnt Extinguishing efficiency 7 tyres or.2% of test stock Suppression mode achieved Copyright SNCP december 27 Page 1

. Max =2 C Max=24 C Max=23 C Max=24 C Nord Max=24 C Max=22 C 1 2 3 4 b Max =26 C Max=28 C Max=31 C Max=29 C Max=21 C Max=22 C 6 7 8 9 1 1b Max =2 C Max=29 C Max=38 C Max=28 C Max=22 C Max=22 C 11 12 13 14 1 1b 2 min 9 s Max =26 C Max=29 C Max=34 C Max=2 C Max=23 C Max=27 C 16 17 18 19 2 2b Stockage témoin (4) Sprinkler non ouvert(2) Sprinkler ouvert (3) North - (2) Unopened sprinklers (3) Open sprinklers (4) Control storage Temperatures / Open sprinkler heads Température / Têtes sprinkler ouvertes 1 9 8 Cornière Avg angle moyenne iron temp 4 7 3 3 cm cm sous below plafond ceiling cm cm sous below plafond ceiling Température ( C) 6 4 Nbre Total total no. têtes open ouvertes heads Nbre No. têtes open ouvertes discharging débitant heads 3 2 3 2 1 1 1 1 2 2 3 3 4 4 6 Time (min) Temps (min) Copyright SNCP december 27 Page 16

Appendix 6 : Summary table of CNPP full-scale tests using K2 ESFR sprinklers (to optimise new warehouses) Test series to define protection characteristics for future warehouses: with K2 ESFR sprinklers for building heights up to 12 m for all types of tyre arrangement (on side, on tread and laced) for storage heights up to 8.7 m

Syndicat National du Caoutchouc et des Polymères - Comité de Prévention et Protection Incendie Summary table of CNPP full-scale tests using K2 ESFR sprinklers (to optimise new warehouses) Test series to define protection characteristics for future warehouses: with K2 ESFR sprinklers for building heights up to 12 m for all types of tyre arrangement (on side, on tread and laced) for storage heights up to 8.7 m Tests date CNPP 21 (VG 7) 21/6/ CNPP 22 (VG 1) 29/6/ CNPP 23 (VG 7-) 6/1/ CNPP 24 (VG 8) 13/1/ CNPP 2 (VG 11) 2/1/ Test objectives Confirm NFPA Rule 13 on tread tyres Confirm NFPA Rule 13 for laced tyres, using K2 heads. Test whether suppression mode is achievable with water density of 67 Test whether suppression mode is achievable with water density of 67 l/min/m2 and a ceiling height of 1. m Test whether suppression mode is achievable with a density of 67 l/min/m 2 and a ceiling height of 12 m for both laced and on tread storage. Test whether suppression mode is achievable with a density of 91 l/min/m 2 and a ceiling height of 12 m for laced storage 8.7m high. l/min/m 2. Storage Type of storage on tread laced on tread laced and on tread laced Storage height (m) 7,4 7,4 7,4 7,4 8,7 Ceiling height (m) 9 9 1, 12 12 Clearance (m) 1.2 1,2 2,7 4,2 2,9 Number of pallets on floor 3x4 + 2 3x4 + 2 3x4 +2 3x4 +2 3x4 Number of pallet levels 4 Number of tyres 22 292 228 2444 3799 Sprinkler Sprinkler type ESFR ESFR ESFR ESFR ESFR SIN number TY 9226 TY 9226 TY 9226 TY 9226 TY 9226 K-factor 2.2 / 363 2.2 / 363 2.2 / 363 2.2 / 363 2.2 / 363 Operating temperature ( C) 74 74 74 74 74 RTI 26 26 26 26 26 Water Actual head pressure (bar) 1,1 1.7 then 2.8 2,8 2,8,2 (only) Flow per head (l/min) 378 468 then 6 63 63 819 Water density at floor (l/min/m 2 ) 42 2 then 67 67 67 91 Fire Location of ignition below heads between 2 heads between 2 heads between 2 heads beneath 1 head beneath 1 head Overall assessment of test results controlled Controlled with 2 l/min/m2 Controlled Suppressed with 67 l/min/m 2 Suppressed Suppressed Suppressed Findings Opening time 1st head 2'38" 3'4" 4'27" 3'7" 2'9" main Number of heads open 7 6 2 1 1 Time to open, heads 2 to n 3'1"/3'14"/3'"/4'3"/12'2"/29'2 " 3'8"/4'/4'/6'19"/6'24" 4'2" Max. angle iron temp ( C) 9 73 31 26 23 Max ceiling gas temperature ( C) 23 223 87 83 87 Mass burned (kg,% test storage) 6 kg/2% 7 kg/2% 14 kg/.6% 6 kg/.3% 6 kg/.2% Lessons learned from test With 7 heads open, only control mode is achieved. Head 7 opens belatedly at 29'2", with the fire well-contained and with little strength. The suppression mode established by With 2 l/min/m 2 : Control mode is achieved (visual observation, low corner temperature, ceiling gas temperature greatly reduced). Suppression mode is achieved. Clearance has no visible or measurable effect. The fire is shielded within the rolls of tyres until the top of the tyre is destroyed and water can get through. Suppression mode is achieved. Clearance has no visible or measurable effect. The fire s kinetic energy is the same for both types of storage, laced and on tread. The effectiveness of fire Suppression mode is achieved. the rule cannot be confirmed with With 67 l/min/m 2, suppression mode The fire does not travel to adjacent tyre containment is the same in both cases. certainty. is achieved. rolls (top, bottom, left right), but can propagate through the ends of the The fire s kinetic energy is similar for rolls. both types of storage, laced and on tread. The rule is confirmed using K2 heads.