The Problem of Counterfeit Refrigerants

Similar documents
Main Anthropogenic Sources of Greenhouse Gases Refrigerants

11/22/2014. (c) DR.A.M.SURENDRA KUMAR

CHAPTER 1 INTRODUCTION

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Ammonia. Background on ammonia as a refrigerant

Chapter 2. Alternatives to HCFCs and their Characteristics

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Low GWP alternative refrigerants to R404A

March 10, 2016 San Joaquin Valley RETA Meeting

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

HFCs or the Old Refrigerants - what is the best Choice?

Natural refrigerants - naturally efficient

A STUDY ON REFRIGERANTS

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

CHAPTER 1 INTRODUCTION

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Navigating a changing refrigerants market

The natural solution for domestic refrigeration

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

(Refer Slide Time: 00:01:07 min) In the present lesson I will present some historical aspects of refrigerant and compressor development.

A Comparison Between Refrigerants Used In Air Conditioning

TECHNICAL NOTE. Use of R290 refrigerant recommendations. Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment

Responsible Care Product Stewardship for Refrigerants

Alternative Refrigerants Part 1 Future and Current Options. Overview

Requirements for Labelling: Labelling of Refrigerant Containers

Refrigerant trends especially focusing on CO 2

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Chapter 10. Refrigeration and Heat Pump Systems

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Flammability and New Refrigerant Options

Guidance for Stationary Refrigeration & Air-Conditioning

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Making equipment decisions

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Experimental Investigation of COP Using Hydro Carbon Refrigerant in a Domestic Refrigerator

Design of LPG Refrigeration System

Chapter 11 REFRIGERATION CYCLES

Oyelami S., Bolaji B. O.

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

Thermodynamics I. Refrigeration and Heat Pump Cycles

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

η second law = Second law efficiency

INDIAN INSTITUTE OF TECHNOLOGY ROORKEE NPTEL NPTEL ONLINE CERTIFICATION COURSE. Refrigeration and Air-conditioning. Lecture-16 Refrigerants-1

Experimental analysis of r134a, r22, and r404 for an edibon taab: Air conditioning lab unit

Global Solutions for Ammonia Industrial Refrigeration

New Refrigerants Designation and Safety Classifications

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

Japanese market and issue of Heat Pump Kenji Matsuda

Figure 23-1 Pressure-temperature curve for water

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

The Current Path of Refrigerants

Winter sports fun all year round, thanks to natural refrigerants

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Chapter 11 REFRIGERATION CYCLES

Use Of Ammonia for Air Conditioning Applications

Gary Parker Refrigerants Product Manager

Official Journal of the European Union

Natural Choice -- Ammonia

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

THE DEVELOPMENT OF THE ISOPROPYL ALCOHOL/PFC CLEANING SYSTEM. presented by

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Refrigerant Choices For The Future Small Industrial Refrigeration Applications

R-404A Alternative with Low Compressor Discharge Temperature

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

GUIDELINES. Nov GAS DETECTION SYSTEMS FOR THE REFRIGERATION INDUSTRY - AN OVERVIEW

Refrigerant Dryers DRY with PDP Indicator

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

Alternative refrigerants or HFCs: an obvious choice? Safety first when choosing a refrigerant!

International Journal of Advance Engineering and Research Development

Transcription:

The Problem of Counterfeit Refrigerants James K Carson President, Commission C2, International Institute of Refrigeration Senior Lecturer, School of Engineering, University of Waikato j.carson@waikato.ac.nz 12 May, 2015

Outline Refrigerants over the years Montreal and Kyoto protocols European F-gas regulations Refrigerant counterfeiting 2

What do we desire of our refrigerant? Chemical stablity Non-toxicity Non-flammability Low molecular weight High energy carrying capability Miscibility with lubricating oil Suitable operating pressure range 3

What do we desire of our refrigerant? Good electrical insulation properties Low index of compression (compressor efficiency) Non-ozone depleting Low or zero global warming potential Others 4

History of refrigerant development BC to 19 th century cold air and ice 1100 BC Chinese poem mentions ice stored specifically for domestic use. 5th Century BC Protagoras reported Egyptians producing ice by placing water on their roofs when there was a clear night sky 37 AD - 68 AD Roman Emperor Nero Claudius is reported to have sent slaves to the mountains to fetch snow to be used specifically for cooling fruit drinks 5

History of refrigerant development Latter half of 19 th century international ice trade, e.g. from USA and Norway to England 6

History of refrigerant development 1755 William Cullen of Glasgow produces ice by evaporating water at low pressure 7

History of refrigerant development 1834 Jacob Perkins patents a vapour compression (VC) system using ethyl-ether - Flammable - Anaesthetic 1863 Charles Tellier patents a VC cycle running on methyl-ether 8

History of refrigerant development 1862 Thaddeus Lowe uses carbon dioxide in a VC system - Non-flammable - Low-critical point - Toxic - Requires high pressure machinery 9

History of refrigerant development 1872 David Boyle uses ammonia in a VC cycle, and subsequently Carl von Linde employed ammonia as a refrigerant - Very efficient - Flammable - Toxic 10

History of refrigerant development 1878 methyl chloride is used as a VC refrigerant in France - Flammable - Toxic 11

History of refrigerant development Early 20 th Century hydrocarbons (propane, iso-butane) began to be experimented with for use in domestic-scale refrigeration in the United States - Flammable 12

History of refrigerant development Late 1920s Charles Kettering of General Motors tasks Thomas Midgley with finding or synthesising the ideal refrigerant as an alternative to methyl chloride, propane and ammonia To reduce flammability, Midgley experimented with the family of halo-carbons; molecules based on carbon with halogens (fluorine and chlorine) instead of hydrogen atoms 13

Organic synthesis CH 3 Cl CH 2 Cl 2 CH 4 CHCl 3 14

Development of CFCs and HCFCs CH 4 CCl 3 F R11 Freon 11 CFC11 CHClF 2 R22 Freon 22 HCFC22 CCl 2 F 2 R12 Freon 12 CFC12 15

R12 close to being the ideal refrigerant Thermodynamically efficient Chemically stable Non-toxic Non-flammable, Miscible with lubricating oil Capable of operating in a domestic refrigerator without going below atmospheric pressure Good electrical insulator Low index of compression so that the compressor would run cool 16

R22 another excellent refrigerant Thermodynamically efficient Non-toxic Non-flammable, Miscible with lubricating oil Less stable than R12 Requires less swept volume than R12 Viewed as a safer alternative to ammonia 17

Domination of CFCs and HCFCs CFCs and HCFCs were able to meet the full range of refrigerant needs from domestic to industrial seemed destined to entirely dominate the refrigerant market In addition to refrigerants, they were also used as propellants and blowing agents for polymer foam manufacture applications where the gases were simply released to the atmosphere 18

Chlorine and the ozone layer 1974 researchers Roland and Molina proposed that chlorine-containing molecules in the stratosphere were destroying the ozone layer After initial skepticism, mounting evidence, particularly in the atmosphere over Antarctica, leads to an international agreement to phaseout chloro-flouro-carbons (CFCs) 19

Montreal protocol 1987 46 countries meet in Montreal to sign the Montreal Protocol on Substances that Deplete the Ozone Layer, with the initial target of reducing CFC consumption by 50 % over 10 years The following year Du Pont, producer of the Freon brand of refrigerants, agrees to reduce production Subsequent protocol meetings were attended by more and more signatory nations, and eventually it was agreed to completely* phase out CFC production and usage 20

Replacing the CFCs With chlorine no longer an option for refrigerants, the search began for replacements for R11 and R12 Ideally the replacements would be physically and thermodynamically similar to the CFCs in order that they could be used in the same equipment ( drop-in replacements) 21

R134a the drop-in replacement for R12 By far the most successful CFC replacement has been R134a a hydrofluorocarbon (HFC) CH 3 CH 3 Ethane CH 2 FCF 3 R134a 22

R134a the drop-in replacement for R12 R134a has very similar properties to R12, although it is slightly less chemically stable and has a lower critical point It was also originally not miscible with commonly used lubricants, but that problem was soon overcome R134a remains in high usage worldwide today 23

Kyoto Protocol 1997 United Nations Framework Convention on Climate Change holds a meeting of UN countries in Japan with the aim of reducing greenhouse gas emissions (which include HFCs) As a result of this and subsequent meetings signatory countries agree to different targets and different time frames for emissions reductions through better handling and storage practices and, in some cases, reducing the usage or completely phasing out some refrigerants 24

GWP data (taken from IRHACE refrigerant code of practice, 2001) R717 ammonia NH 3 0 0 R744 Carbon dioxide CO 2 0 1.0 25

GWP data (taken from IRHACE refrigerant code of practice, 2001) 26

GWP data (taken from IRHACE refrigerant code of practice, 2001) 27

Phase-out of F-gases in Europe The European Union has been particularly aggressive at phasing out refrigerants containing fluorine ( F-gases ) 2006 EU government releases Regulation (EC) No 842/2006 covering the containment and recovery of F-gases along with storage labelling, and training requirements 28

Refrigerant counterfeiting Scheduled phase-out of HFCs causes their price to rise as supply becomes restricted Refrigerants being sold under false labelling e.g. Times of India reported a businessman was caught selling R22 as R134a Refrigerants being contaminated with cheaper refrigerants e.g. R134a is diluted by cheaper refrigerants 29

Contaminated R134a a particular concern Product advertised as R134a may have varying amounts of R22, R30, R40 and R142b The IIR reported an estimated 10 15 % of reefer containers worldwide had contaminated refrigerant 30

Hazards associated with R40 Of the R134a contaminants, R40 (methyl chloride) is particularly hazardous Anaesthetic Flammable Reacts with aluminium producing compounds more flammable and toxic than methyl chloride itself 31

Potential consequences of charging with counterfeit refrigerants Contravention of government regulations Poor refrigeration performance Equipment damage Corrosion Explosions Fires Loss of product/cargo Injury and death Several explosions have caused deaths 32

Checking for, and dealing with contaminated refrigerant Reputable refrigerant suppliers provide guidelines for establishing whether refrigerant is authentic e.g. http://www2.dupont.com/refrigerants/en_us/brand_assurance/i ndex.html The presence of R40 can be determined with a halide flame test (should be done in a well-ventilated area) Modern refrigerant analysers are capable of identifying R40 R40 can be removed from a system in gaseous form; however, the liquid reaction products will collect at the lowest point in the system, making removal more difficult 33

Into the future? 34

Conclusions Due to environmental concerns, fluorine-containing refrigerants (HFCs) have been scheduled for phaseout (i.e. mandatory reduction of production and usage) This has resulted in a price rise in HFC refrigerants, particularly R134a The high price of some refrigerants has lead to counterfeiting, either by diluting them with cheaper refrigerant(s), or by replacing the advertised refrigerant by a completely different one Vigilance is required when dealing with refrigerant systems, particularly when the origin of system, or the reputability of the refrigerant supplier is unknown 35