CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

Similar documents
CR A-F-A-V-HQQV 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ

TP /4-A-F-A-BQQE 400D 50HZ

SL S.S.N.51D

SL EX.4.51D

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

Company name: Created by: Phone:

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

CombiBloc Close-coupled centrifugal pumps

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Lenntech. Tel Fax bar. Multistage Pumps.

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C

GRUNDFOS END SUCTION PUMPS GRUNDFOS END SUCTION PUMPS

dualarm Vertical In-Line Pumps

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

MARLOW PUMPS RECIRCULATION

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CombiPrime Self-priming centrifugal pumps

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091

ARBO Chemical pumps SealPro with mechanical seal. Product group 1.1

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Wilo IL Vertical Split-Coupled Inline Pumps

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

IMMERSIBLE PUMPS FOR INDUSTRY

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

CombiBloc. Close-coupled centrifugal pumps

Transformer oil coolers BETA & CETA

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

SECTION STEAM CONDENSATE PUMPS

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

SECTION STEAM CONDENSATE PUMPS

Specially Designed Waste Water & Sewage Pumps

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

Chemical Pumps Vertical Chemical Pump Type TNP

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Stainless steel centrifugal pumps

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

TYPE LF/LC/LCV END SUCTION PUMPS

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

Oil burners fuel unit with solenoid valve

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Pumps Motors ISO 9001 Company

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

470 Series Stamped Stainless Steel Pumps

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

K4RH(X) Solids-Handling Pumps

TECHNICAL DESCRIPTION

Oil burners fuel unit with solenoid valve

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

DUPLEX CONDENSATE TANK SYSTEM

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

KEENER GRINDER PUMPS

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

Advance Release September 2009

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

ETP Series - Self Priming Pumps

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Vertical Ring-section Pump WKTB. Type Series Booklet

EHH SERIES DRAW THROUGH FAN COILS CFM

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Self-priming centrifugal pumps

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

A. Codes and Standards that are Standard at the University:

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Transcription:

GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CRN 9-1 A-F-G-V-HQQV Product No.: 96124237 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. Pump materials in contact with the liquid are in high-grade stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via DIN flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. Further product details The product carries the Grundfos Blueflux label. It represents the best from Grundfos within energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or exceed legislative requirements such as the EuP IE3 grade. Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. 1/9

The motor stool connects the pump head and motor. The pump head has a combined 1/2" priming plug and air vent screw. The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: FKM (fluorocarbon rubber) FKM has excellent resistance to oils and chemicals. Above 9 C, FKM should only be used in media without water. The shaft seal is retained in the pump head by a cover and screws. It can be replaced without removing the motor. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The pump has a stainless steel base mounted on a separate base plate. The base and base plate are kept in position by the tension of the staybolts which hold the pump together. Both the suction and the discharge side of the base have two pressure gauge tappings. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. Motor 2/9

The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with free-hole flange (FF). Motor mounting designation in accordance with IEC 634-7: IM B 5 (Code I) / IM 31 (Code II). Electrical tolerances comply with IEC 634. The motor efficiency is classified as IE3 in accordance with IEC 634-3. The motor has thermistors (PTC sensors) in the windings in accordance with DIN 4481/DIN 4482. The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. Thermal switches must be connected to an external control circuit in a way which ensures that the automatic reset cannot cause accidents. The motors must be connected to a motor-protective circuit breaker according to local regulations. The motor can be connected to a variable speed drive for adjustment of pump performance to any duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in Win-/WebCAPS. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Curve tolerance: Materials: Pump housing: Impeller: Water 253.. 363 K 293 K 998.2 kg/m³ 2919 rpm 9 m³/h 2.2 m HQQV ISO 996:1999 Annex A Stainless steel DIN W.-Nr. 1.448 AISI 316 LN Stainless steel DIN W.-Nr. 1.441 AISI 316 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 16 bar / 9 C 16 bar / -2 C Flange standard: DIN Pipe connection: DN 1 Pressure stage: PN 16 Flange size for motor: FF265 Electrical data: Motor type: 132SB IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 7.5 kw Power (P2) required by pump: 7.5 kw Mains frequency: 5 Hz 3/9

Position Qty. Description Rated voltage: 3 x 38-415 D/66-69 Y V Rated current: 14,4-14,/8,3-8,1 A Starting current: 78-91 % Cos phi - power factor:,88-,82 Rated speed: 291-292 rpm Efficiency: IE3 9,1% Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 119 kg Gross weight: 142 kg Shipping volume:.47 m3 4/9

96124237 CRN 9-1 5 Hz H [m] CRN 9-1, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 35 3 25 1 2 8 15 6 1 4 5 2 1 2 3 4 5 6 7 8 9 1 11 12 P2 [kw] 7 Q [m³/h] NPSH [m] 14 6 12 5 1 4 8 3 6 2 4 1 2 5/9

Description Value Product name: CRN 9-1 A-F-G-V-HQQV Product No: 96124237 EAN number: 5739675514 Technical: Speed for pump data: 2919 rpm Rated flow: 9 m³/h Rated head: 2.2 m Impellers: 1 Shaft seal: HQQV Curve tolerance: ISO 996:1999 Annex A Stages: 1 Pump version: A Model: A Materials: Pump housing: Impeller: Material code: Code for rubber: Stainless steel DIN W.-Nr. 1.448 AISI 316 LN Stainless steel DIN W.-Nr. 1.441 AISI 316 G V Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 16 bar / 9 C 16 bar / -2 C Flange standard: DIN Connect code: F Pipe connection: DN 1 Pressure stage: PN 16 Flange size for motor: FF265 H [m] 35 3 25 2 15 1 5 2 4 6 8 1 P2 [kw] 134 22 4 2 298 PN16/DN1 8 x ø18 CRN 9-1, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ ø22 ø18 ø156 4 x ø14 ø1 45 199 28 261 348 38 Q [m³/h] eta [%] 1 8 6 4 2 NPSH [m] 1 5 14 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253.. 363 K 293 K 998.2 kg/m³ 571 379 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 Electrical data: Motor type: 132SB IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 7.5 kw Power (P2) required by pump: 7.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-415 D/66-69 Y V Rated current: 14,4-14,/8,3-8,1 A Starting current: 78-91 % Cos phi - power factor:,88-,82 Rated speed: 291-292 rpm Efficiency: IE3 9,1% Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Motor protec: PTC Motor No: 85U17522 +T +T +T TO AMPLIFIER RELAY L1 L2 L3 +T +T +T TO AMPLIFIER RELAY L1 L2 L3 Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 119 kg Gross weight: 142 kg 6/9

Description Shipping volume: Value.47 m3 7/9

96124237 CRN 9-1 5 Hz 22 134 571 379 298 PN16/DN1 8 x ø18 14 ø156 ø18 ø22 199 45 ø1 4 x ø14 261 38 28 348 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 8/9

96124237 CRN 9-1 5 Hz +T +T +T TO AMPLIFIER RELAY +T TO AMPLIFIER RELAY L1 L2 L3 +T +T L1 L2 L3 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 Note! All units are in [mm] unless others are stated. 9/9

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89