ICE/BEVERAGE DISPENSER

Similar documents
MODELS: TJ45 TJ90 Operator s Manual

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

ICE/BEVERAGE DISPENSER

Product Manual. Scotsman. Models: 10150, and 10250

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

Telephone (800) Facsimile (800)

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

ICE/BEVERAGE DISPENSER

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

ICE/BEVERAGE DISPENSER

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve

ICE/BEVERAGE DISPENSERS

ICE/DISPENSER Model D3030

ICE/BEVERAGE DISPENSER MODELS: ENDURO-150 (SIX VALVE) INSTALLATION MANUAL

ILLUSTRATED PARTS LIST ENDURO VALVE

ICE/BEVERAGE DISPENSER

TROUBLESHOOTING VANGUARD

STARBUCKS UC100 PROGATE

UC300. INSTALLATION & SERVICE GUIDE Part Number

LANCER SERIES H, ICE BEVERAGE DISPENSER 44 INCH WIDE, 12 VALVE, 115V/60Hz

ICE DISPENSER. Installation/Service Manual

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123

HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A SERVICE MANUAL

ICE/BEVERAGE DISPENSER

HD150. Introduction. Table of Contents

Table Of Contents. Introduction... Page 1. Specifications... Page 2. Diagrams... Page 3. Uncrating... Page 4. Ice Machine...

Service Manual. Ice Dispensing Bin Models DB-130H. hoshizakiamerica.com

Service Manual. Ice Dispensing Bin Models DB-200H. hoshizakiamerica.com

U155 Series Ice and Beverage Dispensers

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

MODEL 6430T, 6460 & 6460T POTATO PEELER

Installation/Service Manual VANGUARD 245 POST-MIX OVERCOUNTER DISPENSER

Nordic Hotel Dispenser Model CHD22 /CHD30 Installation and Service Manual

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

Ice Pro DB650, EDB650 Automatic Ice Bagging and Dispensing System

Symphony Plus 25 and 50 Series Ice and Water Dispensers 25FB425A/W, 50FB425A/W

VU155K Integral Cold Carbonation Series Ice and Beverage Dispensers

Fountain Classic. Installation and Owner s Manual. Page 16

Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

ICED CAPPUCCINO MACHINE Taylor MODEL: 390

Installing the Turbo Floor Model System

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

Machine MANUAL. Spaceman USA, LLC. Sales and Product Information Sunday Saturday 8 AM 5 PM Mountain. 226 Commerce Street Suite B Broomfield, CO 80020

Hoshizaki America, Inc.

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C)

GB5MV-10-LD GB6MP-10-LD-U GB8MP-10-LD-U

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

IDC 255 PROGATE DRIVE THRU

PRE INSTALLATION PROCEDURES

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

Model HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

S250M 8 & 10 Valve Beverage/Ice Dispenser with Flex Manifold. Installation, Use & Care Manual

HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A INSTRUCTION MANUAL

MODEL 1308-C & 1308-N

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

STERO SD1. Low Temp Dishwasher MODEL: ML


SELF-CONTAINED FLAKER

Operator Manual Autofill System

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

SaniServ. Operator s Guide. Model 601 Shake Machine With AccuFreeze. Reliability from the team that Serves the Best

IMI Cornelius Automated Beverage System (ABS)

CEILING FAN OWNER S MANUAL

Hoshizaki America, Inc.

PRE INSTALLATION PROCEDURES

5000 Series Bottled Water System by.

Whirlpool AUTOMATIC ICE CUBE MAKER. User s Instructions & Care and Cleaning Guide MODELS CH E-5R CHS-5R CHE-7R CHS-7R. Part No.

Installation and User s Manual for Meridian Ice Maker-Dispensers models HID312, HID525 and HID540

Water Boilers ME10EN, ME15EN. Table of Contents

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

User information. Cleaning/descaling and sanitizing

Hoshizaki America, Inc.

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

Frosty Factory of America, Inc.

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

Operator s Manual. Stripping Solution Applicator

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

UF424 and UN324. Technical Service

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

Operator s Manual. Frozen Beverage Granita Machines

CBT LW MAINTENANCE GUIDE

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

ADVANTAGE-100H-SC EXTRACTOR

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Machine MANUAL. Spaceman USA, LLC. Sales and Product Information Sunday Saturday 8 AM 5 PM Mountain. 226 Commerce Street Suite B Broomfield, CO 80020

Installation and Setup

USER S MANUAL EUROPEAN SCRUB-PRO GOLF BALL CLEANSER

PERLICK PRODUCT MANUAL SELF-CONTAINED ICE MAKER MODELS: H50IMS-R H50IMS-L H50IMW H50IMS-ADL H50IMS-ADR H50IMW-AD

Simplicity Bubbler Crathco Cold Beverage Dispensers

Transcription:

ICE/BEVERAGE DISPENSER MODELS: DB150, DB150-B, DB150-BC DB150-Z Operator s Manual Publication Number: 91328 Release Date: May 01, 1997 Revision date: May 08, 2014 Revision: E THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment PRINTED IN U.S.A

TABLE OF CONTENTS SAFETY PRECAUTIONS................................................... 1 GENERAL DESCRIPTION.................................................. 1 *CABINET OPTIONS....................................................... 2 INSTALLATION INSTRUCTIONS............................................ 3 GATE RESTRICTOR PLATE............................................ 5 ADJUSTMENT........................................................ 5 MAINTENANCE........................................................... 9 DAILY (OR AS REQUIRED)............................................. 9 WEEKLY (OR AS REQUIRED).......................................... 9 MONTHLY............................................................ 9 START-UP AND OPERATING INSTRUCTIONS........................... 9 CLEANING INSTRUCTIONS................................................ 9 DISPENSER (ALL MODELS)........................................... 9 COLD PLATE (-BC MODELS)........................................... 10 BEVERAGE SYSTEM (-B, -BC MODELS)................................ 10 TROUBLESHOOTING GUIDE............................................... 12 BLOWN FUSE OR CIRCUIT BREAKER.................................. 12 GATE DOES NOT OPEN................................................ 12 GATE DOES NOT OPEN OR IS SLUGGISH. AGITATOR TURNS............ 12 GATE OPENS. AGITATOR DOES NOT TURN............................. 12 ICE DISPENSES CONTINUOUSLY....................................... 12 SLUSHY ICE. WATER IN HOPPER....................................... 12 BEVERAGES DO NOT DISPENSE...................................... 12 BEVERAGES TOO SWEET............................................. 12 BEVERAGES NOT SWEET ENOUGH.................................... 12 BEVERAGES NOT COLD (UNITS WITH BUILT-IN COLD PLATE)............ 12 DB150 PARTS LIST........................................................ 15

LIST OF FIGURES FIGURE 1. SINK DRAIN ASSEMBLY..................................... 3 FIGURE 2. INSTALLATION INSTRUCTIONS P/N 27065 ICE DIVERTER..... 4 FIGURE 3. GATE RESTRICTOR PLATE.................................. 5 FIGURE 4. MOUNTING TEMPLATE DB150 BC BCZ UNITS............. 6 FIGURE 5. MOUNTING TEMPLATE DB150 B AND Z UNITS.............. 7 FIGURE 6. PLUMBING DIAGRAM -B MODELS.......................... 8 FIGURE 7. PLUMBING DIAGRAM -BC MODELS......................... 9 FIGURE 8. WIRING DIAGRAM DB150-B DISPENSER..................... 14 FIGURE 9. WIRING DIAGRAM DB150-BC DISPENSER.................... 15 FIGURE 10. DISPENSING LEVERS AND SWITCHES...................... 17 FIGURE 11. GATE SOLENOID ASSEMBLY............................... 18 LIST OF TABLES TABLE 1. SPECIFICATIONS............................................ 2 Manufactured Under One or More of the Following Patent Numbers: 3,211,336, 3,274,792, 3,393,839, 3,517,860, 3,739,842, 4,215,803, 4,227,377, 4,300,359, 4,346,824 Canadian Patent Numbers 912,514 (10/72), 936,855 (11/73), 4,429,543, 4,921,149 Other Patents Pending

SAFETY PRECAUTIONS Always disconnect power to the dispenser before servicing or cleaning. Never place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation occurs automatically when the dispenser is energized! This ice dispenser has been specifically designed to provide protection against personal injury and eliminates contamination of ice. To ensure continued protection and sanitation, observe the following: ALWAYS be sure the removable lid is properly installed to prevent unauthorized access to the hopper interior and possible contamination of ice. ALWAYS be sure the upper and lower front panels are securely fastened. ALWAYS keep area around the dispenser clean of ice cubes. CAUTION: Dispenser cannot be used with crushed or flaked ice. Use of bagged ice, which has frozen into large chunks, can void warranty. The dispenser agitator is not designed to be an ice crusher. Use of large chunks of ice which jam up inside the hopper will cause failure of the agitator motor and damage to the hopper. If bagged ice is used, it must be carefully and completely broken into small, cube-sized pieces before filling into the dispenser hopper. GENERAL DESCRIPTION The 3030 series of ice dispensers solve ice and beverage service needs in the sanitary, space saving, economical way. Designed to be manual filled with ice from any remote ice-making source, these dispensers will dispense cubes (up to 1-1/4?in size), cubelets and hard-chipped or cracked ice; and in addition, several flavors of post-mix beverages. B models contain beverage faucets only and must be supplied with cold product from any remote cold plate or refrigerated soda factory. BC units include faucets and cold plates and are designed to be supplied directly from syrup tanks and carbonator, with no additional cooling required. IMPORTANT: For dispensing Scotsman pellet style ice (Model MH750 Ice makers), REMCOR part number 27065 Ice Diverter must be installed on the dispenser. (See INSTALLATION INSTRUCTIONS Figure 2). 1

Table 1. Specifications Model: DB150 Ice Storage: 150 lbs. Maximum Number of Faucets Available: Not Available Built-in Cold Plate: No Electrical: 120/1/60 Dimensions: 22?W x 29-3/4?D x 34-3/16?H Model: DB150*-B Ice Storage: 150 lbs. Maximum Number of Faucets Available: 6 Built-in Cold Plate: No Electrical: 120/1/60 Dimensions: 22?W x 29-3/4?D x 34-3/16?H Model: DB150*-BC Ice Storage: 150 lbs. Maximum Number of Faucets Available: 6 Built-in Cold Plate: Yes Electrical: 120/1/60 Dimensions: 22?W x 29-3/4?D x 34-3/16?H Model: DB150Z, -BZ,-BCZ Ice Storage: 150 lbs. Maximum Number of Faucets Available: 6 Built-in Cold Plate: Yes Electrical: 120/1/60 Dimensions: Ice Only and B Units22?W x 21?D x 34-3/16?H BC units 22?W x 22-1/4?D x 36-3/16?H *CABINET OPTIONS E - S - Neutral Beige Baked Enamel Finish with Wood Grain Vinyl-clad Upper Front Panel All Stainless Steel W- White Baked Enamel Finish 2

INSTALLATION INSTRUCTIONS NOTE: This equipment must be installed with adequate backflow protection to comply with federal, state, and local codes. Note: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained according to Federal, State and Local Laws. 1. Locate the dispenser indoors on a level counter top. Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the unit. The installer must provide flexibility in the product and utility lines to permit shifting the position of the dispenser sufficiently to clean the area beneath it. 2. Utilities: DB150 Model - The electrical power cord and dispenser drain (3/4 FPT) are located at the rear of the unit. DB150 -B, -BC Model - All utilities are routed out the bottom of the unit. See Mounting Template Figure 5 for locating the required clearance holes in the counter for these utility lines. 3. Connect the drain tube to an open drain. For DB150 models, the drain line size must be 3/4?IPS (or equal) and must continuously pitch downward away from the unit and contain no traps or improper drainage will result. SINK DRAIN ASSEMBLY -B, -BC MODELS A. Use tube, clamp and insulation provided to assemble drain. B. To assure proper drainage, do not allow trap to form in drain line. Be sure drain line runs flat with bottom of dispenser. (See figure below.) DRAIN LINE STAINLESS STEEL ELBOW DISPENSER BOTTOM DRAIN TUBE PROVIDED WITH DISPENSER FIGURE 1. SINK DRAIN ASSEMBLY 4. -B, -BC models: connect the beverage system product lines as indicated in B and BC units, page NO TAG. This work should be done by a qualified serviceperson. Note that the hoses are marked with numbers 1 through 6 for syrup connections and CW for carbonated water connection. 5. Clean the hopper interior (see CLEANING INSTRUCTIONS). 6. CONNECT THE POWER CORD TO A 120 VOLT, 60 CYCLE, 3-WIRE grounded receptacle. 3

GATE MOUNTING PLATE STORAGE HOPPER ICE DIVERTER GASKET ICE CHUTE APPLY RTV TO THIS SURFACE TO SEAL TO HOPPER GATE MOUNTING PLATE 10-32 WASHER FLANGE EXTENDS INTO STORAGE HOPPER THROUGH GATE OPENING 10-32 NUT FIGURE 2. INSTALLATION INSTRUCTIONS P/N 27065 ICE DIVERTER 4

GATE RESTRICTOR PLATE CAUTION: Disconnect power to dispenser before installing, removing or adjusting restrictor. INSTALL PLATE ON STUDS AS SHOWN FIGURE 3. GATE RESTRICTOR PLATE ADJUSTMENT This dispenser is provided with a gate restrictor plate installed in it s highest position. This plate adjusts the rate of ice flow from the dispenser. In applications using buckets, carafes or other large containers, the plate may be removed entirely for maximum ice flow. For glasses and cups, the plate may be adjusted downward to reduce the flow of ice. The best position depends on the type of ice being used and the size container and must be found by trial and error. Adjustment is made by loosening the upper two ice chute retaining nuts, sliding the restrictor plate to the desired position and re-tightening the nuts. If the dispenser fails to dispense the ice when operating, check that the hopper has ice in it and that power is being supplied to the unit. If the problem persists, check the following: 1. Determine if the agitator is rotating (check for the sound of ice movement in the hopper). 2. Observe whether the gate is opening. 5

*1 1/8-IN. 14-IN. 4-IN. 1 1/32-IN. 4 1/2-IN. 16 1/4-IN. 9 29/32-IN. *18 3/4-IN. 22 1/4-IN. BCZ MODELS 29 3/4-IN. W/SINKS 5/16-DIA. OUTLINE OF UNIT OPTIONAL: FRONT OPENING FOR BEVERAGE AND UTILITIES *1 1/8-IN. *19 3/4-IN. 22-IN. NOTE: Shaded areas indicate openings in cabinet bottom needed for utilities and beverage tubing. * Leg mounting locations for ref. (5/16--18 threads) FIGURE 4. MOUNTING TEMPLATE DB150-BC AND BCZ 6

*1 1/8-IN. 14-IN. 4-IN. 1 1/32-IN. 4 1/2-IN. 16 1/4-IN. *18 3/4-IN. 21-IN. 29 3/4-IN. 5/16-DIA. OUTLINE OF UNIT *1 1/8-IN. *19 3/4-IN. 22-IN. NOTE: Shaded areas indicate openings in cabinet bottom needed for utilities and beverage tubing. * Leg mounting locations for ref. (5/16--18 threads) FIGURE 5. MOUNTING TEMPLATE DB150-B AND Z 7

8 FIGURE 6. PLUMBING DIAGRAM -B MODELS

9 FIGURE 7. PLUMBING DIAGRAM -BC MODELS

MAINTENANCE The following dispenser maintenance should be performed at the intervals indicated: DAILY(or as required) Remove foreign material from the vending area sink to prevent drain blockage. WEEKLY (or as required) Clean vending area. Check for proper water drainage from the vending area sink. MONTHLY Clean and sanitize the hopper interior (see CLEANING INSTRUCTIONS). START-UP AND OPERATING INSTRUCTIONS Fill the hopper with ice. With a built-in cold plate, dispense several large cups of ice (approximately one {1} minute total dispensing time) to allow ice to fill the cold plate. Add ice to the hopper as necessary to refill and replace the lid. Allow 10 to 15 minutes for the cold plate to cool down. Repeat this procedure whenever the dispenser has been standing overnight or other long periods without ice use. Start up the beverage system and adjust faucets to the proper brix. Contact your local syrup distributor for complete information on the beverage system. In normal operation, pushing the ice dispenser lever will cause ice to flow from the ice chute. Ice flow will continue until the lever is released. Pushing the lever on any faucet will provide beverage of the appropriate flavor. NOTE: Use caution to avoid spilling when filling dispenser. Immediately clean up any spilled ice from filling or operating the unit. To prevent contamination of ice, the lid must be installed on the unit at all times. CLEANING INSTRUCTIONS WARNING: DISCONNECT POWER BEFORE CLEANING! Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper, top cover and the agitator disk, as damage may result. Do not use solvents or other cleaning agents, as they may attack the plastic material. DISPENSER (All Models) 1. Clean the ice storage hopper at least once a month. 2. Remove the center screw and washer on the agitator disk and lift off the agitator and the agitator disk assembly. Wash and rinse them thoroughly. 3. Wash down the inside of the hopper and top cover with a mild detergent solution and rinse thoroughly to remove all traces of detergent. 10

4. Replace the agitator. 5. Sanitize the inside of the hopper and agitator with a solution of 1/2 ounce of household bleach in 1 gallon of water. (200 PPM) 6. Replace the agitator disk. Sanitize as described in Step 5. Be sure the center screw is replaced and the screw is tight. 7. Remove ice chute cover as follows: A. Flex sides outward to disengage lower pins. B. Lift ice chute cover to disengage upper pins. C. Lower ice chute cover down out of unit. NOTE: It may be helpful to twist cover slightly. 8. Clean the inside of the ice chute with a mild detergent solution and rinse thoroughly to remove all traces of detergent. 9. Reverse steps above to reassemble ice chute. 10. Sanitize as described in Step 5. COLD PLATE (-BC MODELS) 1. Carefully remove screws holding beverage faucet panel and bring forward. 2. Slide the cold plate cover back. (Remove shipping tape and discard). 3. Remove debris from the drain trough and spring. Check that the drain hole is not clogged. 4. Wash down the inside of the cold plate, tray and cover with a mild detergent solution and rinse. A small, long-handled brush will be found helpful in reaching the corners. 5. Slide the cover forward, taking care that it s securely positioned on the cold plate. 6. Replace beverage faucet panel. BEVERAGE SYSTEM CLEANING AND SANITIZING (-B, -BC MODELS) 1. Prepare the following cleaning, rinsing and sanitizing solutions using a clean, empty figal (5 gallon syrup tank) for each solution. CLEANING TANK -- Fill with a solution of 1/2 ounce of a mild liquid detergent (for example, Ivory liquid) to 1 gallon of warm (120_F) potable water. RINSING TANK -- Fill with warm (120_F) potable water. SANITIZING TANK -- Fill with a chlorine sanitizing solution in the strength of 1/2 ounce of household bleach (sodium hypochlorite) to 1 gallon of cold (ambient) potable water to obtain a solution strength of 200 PPM. NOTE: Repeat the following procedure on each of the unit s syrup product lines and beverage faucets. 2. Using a suitable pail or bucket, fill one with a detergent solution and a second container with a sanitizing solution in the strengths as described in step 1. A. Remove the syrup line quick disconnect fitting from the product tank and submerge in the detergent solution. Clean with a nylon bristle brush (do not use a wire brush). Rinse with clean potable water. B. Wearing sanitary gloves, next submerge the quick disconnect fitting in the sanitizing container for 15 minutes. Remove and air dry. 11

3. Hook-up the sanitized product line fitting (step 2) to the cleaning tank. Hook-up a gas disconnect fitting to the tank and pressurize with 60 to 80 psig CO 2. Energize the beverage faucet continuously for 1 minute to remove all air bubbles. Continue to operate the faucet until liquid dispensed is free of any syrup. Cycle the faucet for 15 seconds on, off and then immediately on again. Repeat this procedure for 15 cycles. Then energize the faucet to remain flowing for 3 minutes. 4. Hook-up the rinsing tank and pressurize with 60 to 80 psig CO 2. Flush the cleaning solution from the product line by cycling the faucet as described in step 3 and then energize the faucet to flow continuously for 3 minutes. 5. Hook-up the sanitizing tank and pressurize with 60 to 80 psig CO 2. Flow the sanitizing solution through the beverage faucet by cycling the faucet as described in step 3. Next energize the faucet continuously to flush at least 2 cups of the sanitizing solution through the system. Finally deenergize the faucet and allow the sanitizer to remain pressurized in the line to 20 minutes. 6. Wearing sanitary gloves. remove the faucet nozzle and diffuser. Repeat the cleaning and sanitizing procedures as described in step 2, then reassemble to the faucet. 7. Disconnect the sanitizing tank. Hook-up the product tank to the unit and to the CO 2 system. Energize the faucet to flush the sanitizing solution from the syrup line and the faucet. Continue flow on the faucet until only syrup is dispensed. 12

TROUBLESHOOTING GUIDE Should your unit fail to operate properly, check that there is power to the unit and that the hopper contains ice. If the unit does not dispense, check the following chart under the appropriate symptoms to aid in locating the defect. Trouble BLOWN FUSE OR CIRCUIT BREAKER. A. Short circuit in wiring. B. Defective gate solenoid. C. Defective agitator motor. GATE DOES NOT OPEN. A. No power. GATE DOES NOT OPEN OR IS SLUGGISH. AGITATOR TURNS. Probable Cause B. Bent depressor plate (does not actuate switch). C. Defective dispensing switch. D. Blown/defective fuse or jammed gate solenoid. A. Defective gate solenoid. B. Weak gate spring. C. Excessive pressure against gate slide. GATE OPENS. AGITATOR DOES NOT TURN. A. Ice solidified in hopper. B. Defective agitator motor. C. Defective capacitor. D. BC models only: Defective agitation timer. ICE DISPENSES CONTINUOUSLY. A. Stuck or bent depressor plate (does not release switch). B. Defective dispensing switch. C. Improper switch installation. SLUSHY ICE. WATER IN HOPPER. A. Blocked drain. B. Unit not level. C. Poor ice quality due to water quality or icemaker problems. D. Improper use of flaked ice. BEVERAGES DO NOT DISPENSE. A. No 24 volt power to faucets. B. No CO 2 pressure. BEVERAGES TOO SWEET. A. Carbonator not working. B. No CO 2 pressure in carbonator. C. Faucet brix requires adjusting. BEVERAGES NOT SWEET ENOUGH. A. Empty syrup tank. BEVERAGES NOT COLD (UNITS WITH BUILT-IN COLD PLATE). B. Faucet brix requires adjusting. A. Unit standing with no ice in hopper -- no ice in cold plate. Contact your local syrup or beverage equipment distributor for additional information and troubleshooting of your beverage system. 13

LIGHTED DISPLAY OPTION ICE LEVEL SIGNAL OPTION T STAT LIGHT L N GROUND GRN BALLAST LIGHT STARTER BLK WHT WHT BLK WHT GATE SOLENOID 1 1/4 AMP TIME DELAY FUSE Q.C. CONNECTOR KEY SWITCH OPTION 24 V. TRANSFORMER BEVERAGE FAUCET (TYPICAL) CONNECTION TERMINAL BOARD RED WHT YEL BLK BLU RED BEVERAGE SYSTEM RED RED CCW AGITATOR MOTOR PORTION CONTROL OPTION TO TERMINAL BOARD{ WHT RED BLK PORTION TIMER SW TD OR RED DISPENSE SWITCH BLK DISPENSE SWITCH CAPACITOR SERVICE INFORMATION DANGER! ELECTRIC SHOCK HAZARD. DISCONNECT POWER BEFORE SERVICING UNIT. 7 8 SOLENOID ADJUSTMENT WHEN REPLACING SOLENOID, ADJUST TO 7/8 AS SHOWN BEFORE TIGHTENING MOUNTING SCREWS. FIGURE 8. WIRING DIAGRAM DB150-B DISPENSER 14

ICE LEVEL SIGNAL OPTION T STAT LIGHT MOTOR HEATER OPTION L N GROUND GRN LIGHTED DISPLAY OPTION BALLAST LIGHT STARTER BLK WHT WHT GATE SOLENOID 1 1/4 AMP TIME DELAY FUSE AGITATION TIMER WHT WHT BLK BLK C NO NC PNK 24 V. TRANSFORMER Q.C. CONNECTOR KEY SWITCH OPTION BEVERAGE FAUCET (TYPICAL) WHT YEL BLK BEVERAGE SYSTEM TERMINAL BOARD BLU PORTION CONTROL OPTION PORTION TIMER SW OR RED TD DISPENSE RED CONNECTION RED RED CCW AGITATOR MOTOR TO TERMINAL BOARD WHT RED BLK SWITCH BLK DISPENSE SWITCH CAPACITOR SERVICE INFORMATION DANGER! ELECTRIC SHOCK HAZARD. DISCONNECT POWER BEFORE SERVICING UNIT. 7 8 SOLENOID ADJUSTMENT WHEN REPLACING SOLENOID, ADJUST TO 7/8 AS SHOWN BEFORE TIGHTENING MOUNTING SCREWS. FIGURE 9. WIRING DIAGRAM DB150-BC DISPENSER 15

DB150 PARTS LIST Item No. Part No. Name 1 214910 Gate Slide 2 23062 Foam Shield 3 215150 Depressor, Lever (Cup Activated) 4 26591 Agitator 51916 Agitator Disk 5 30895 Dispense Switch (for items 3 & 28) 6 31007 Switch Boot (for item 5) 7 31091 Transformer (-B, -BC Models) 8 32498 Agitator Motor 9 51859 Motor Shaft Seal 10 51860 Motor Gasket 11 51757 Lid 12 50793 Sink 51850 Sink (-BC Models Only) 13 53015 Ice Chute Back Section 53016 Ice Chute Cover 14 51891 Gate Gasket 15 70441 Sink Grill 16 70419 Leg 17 91362 Wiring Diagram 18 91303 Press for Ice Label 19 30774 Capacitor, Agitator Motor 20 31763 Agitation Timer (-BC Models Only) 21 31093 Gate Solenoid Assembly (See page 18) 22 31551 Gate Solenoid Kit 23 70438 Rebuilding Kit (Gate Solenoid) 24 31406 Fuse, Gate Solenoid 25 22644 Depressor Retainer (for 21515) 26 30794 Agitator Motor Heater (-BC Models Only) 27 90369 Wiring Diagram (-BC Models Only) 28 27126 Depressor Push Lever 29 27107 Depressor Retainer (for 27126) 30 70847 Switch Spacer Optional 31 91511 Push for Ice Label 32 32763 Switch, Push Bottom 16

31 32 30 CUP ACTIVATED 6 5 25 3 30 PUSH LEVER 28 6 5 29 FIGURE 10. DISPENSING LEVERS AND SWITCHES 17

22 1 2 3 4 5 4 22 6 19 22 21 16 15 14 18 20 8 11 10 17 19 13 9 12 7 FIGURE 11. GATE SOLENOID ASSEMBLY Index No. Part No. Qty. Name 1 21493 1 Solenoid Mounting Plate 2# 31551 1 Solenoid Service Kit 3 70171 2 8--32 x 3/8 Phil Tr HD Screw 4 70121 2 No. 8 Lockwasher 5 50752 3 Isolator 6* 50789 2 Bumper Assembly 7* 70423 1 Cotter Pin 8* 10080 1 Gate Lift Rod 9 10081 1 Gate Lift Rod Bushing 10 50754 1 Gate Arm Bearing 11 21492 1 Gate Lift Arm 12 70043 1 Flatwasher 13* 70422 1 Spring 14 70263 1 1/4-20 x 3/4 Hex Hd Screw 15 70048 1 1/4 Lockwasher 16 70066 1 1/4 Flatwasher 17 10077 1 Pivot Bearing 18 30227 1 1/4 Quick Connect Tab 19 50305 ---- Lubricant 20* 21592 1 Solenoid Linkage Pin 21* 70433 2 Retainer Ring 22 51088 ---- Loctite ----* 70438 ---- Rebuilding Kit NOTE: * Parts supplied with rebuilding kit. # 31551 solenoid supplied with items 20 & 21. 18