Liebert. Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

Similar documents
Liebert. Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control

LIEBERT LIQUI-TECT 460 KIT ZONE LEAK-DETECTION SENSOR WITH CABLE

Liebert. Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

Liebert Mini-Mate2 1 To 8 Tons

Liebert. CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Liebert Mini-Mate2 1 To 8 Tons

Liebert Mini-Mate2 1 To 8 Tons

ACHIEVING ENERGY-EFFICIENT DATA CENTER COOLING: DOES REDUCING FAN SPEED ALWAYS RESULT IN ENERGY SAVINGS?

Liebert PPC Second Generation Power Distribution Cabinet

FTA200-A REMOTE ALARM PANEL

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

Leak Detection and Location Systems

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

TraceTek FIND LEAKS BEFORE THEY FIND YOU

Liebert OVERHEAD COOLING IN A VARIETY OF CAPACITIES AND CONFIGURATIONS. Mini-Mate2. 1 to 8 Tons. Provides Precision Cooling And Humidity Control

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

KEY POINTS OF DESIGN, INSTALLATION AND MAINTENANCE FOR CONFIGURING LIEBERT XD SYSTEMS. Technical Note

/ / White Paper. Focusing on user experience

FireClass. Introducing a new class of fire detection

FTA550 JOCKEY PUMP CONTROLLERS

AmpLight Lighting Management System

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Manage Alert Rules & Teams

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Liebert Challenger. Unmatched Environmental Control To Match Many Applications. Precision Cooling For Business-Critical Continuity

Flexible & Innovative. Cooling Solutions

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Practical Home Automation

Circulating Water Temperature Controller

Simplex Panel Interface Guide

Liebert HIROSS for Telecom

Consultant Specification AGILE Wireless Fire Detection System

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Liebert Monitoring Solutions: Protecting Your Investment Against The Unknown. Monitoring For Business-Critical Continuity

Fixed Speed Rotary Screw Compressors UP6S Series hp (11-22 kw)

They ll never know... LEADERS IN WIRELESS SECURITY SURVEILLANCE EQUIPMENT

UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus

Compact Product Suite Compact HMI 6.0 Overview ABB

LORAIN CSP DC Power System

A Beginners Guide to Inner Range Systems

LORAIN CIP 4890/48120 DC Power System

CSP-204 CSP-208 CSP-104 CSP-108

Precision Cooling. DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application

FiRe mobile-2 Operation Manual

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

Security Escort. boschsecurity.com. Reliable wireless location solutions

Liebert DS. Designed To A Higher Standard Of Performance And Reliability. Precision Cooling For Business-Critical Continuity

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

ALCATEL-LUCENT OPENTOUCH NOTIFICATION SERVICE IMPROVE REAL-TIME SITUATIONAL AWARENESS AND PERSONAL SAFETY

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

FlameRanger. Revolutionary Firefighting Robot.

RLDS - Remote LEAK DETECTION SYSTEM

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

SAFETY INFORMATION AND WARNINGS

PERMACONN PM1030 Includes DI300. Installation Manual

PRYCO, INC. FUEL CONTROL

Advanced Facility Air-Management Technology

Control Panel User Guide

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Flexible Air-sampling Smoke Detection

OACS Outdoor Air-Cooled Central Chillers

Auto Technology Company Cyclic Corrosion Test Chamber

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

Standoff CWA/TIC Detection. Innovation with Integrity. Toxic Gas/Vapour Threat Mitigation RAPIDplus CBRNE

Planning Guide EnviroAlert Monitoring Systems

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Section PERIMETER SECURITY SYSTEMS

SRK-PSE90. Installation Instructions. Stud Rail Kit for PSE90 Manual Wall Bracket. Issue 001

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

suite of security systems

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Oracle Retail Merchandise Financial Planning

SiteSentinel itouch Console

EasyLog Data Logger Series

PowerMaster Security Solutions

DynAMo Alarm & Operations Management

HOBO U14 Data Logger User Manual

EasyLog Data Logger Series

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

MODEL NUMBER: SRCOOL60KCW

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

KM300 Carbon Monoxide Detection System Installation Manual

ONYXWORKS AND FIRSTVISION. Version 4

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

Intelligent alarm management

Emergency Communications

D-TECT 3 IP. GJD260 IP Motion Detector

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Liquid Helium Level Instruments

nvenience Store Automation tore Automation

Architectural and Engineering Specification for a Security Management System. StarNet 2

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

IMR IX176 Portable Gas Detector User Manual

Transcription:

Liebert Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

LIEBERT LIQUI-TECT Water Damage Can Be a Catastrophic Event for Computers and Networks Your critical computing, communications or process control facility could be exposed to water and you may not even know about it until it's too late. Water damage puts your facility at risk. The Liebert Liqui-tect solution is the one source that can help you avoid water damage with a complete solution that includes monitoring system, sensors, cables and software. When a conductive liquid comes in contact with the leak detection cable, the system is able to report the distance to the leak and jointly works with the Interactive map that indicates the location of the leak. Liebert Liqui-tect Monitoring System Liebert brings you the ultimate in leak detection and reporting capabilities. The Liebert Liqui-tect Monitoring System provides monitoring different areas with direct-read at the control unit location, as well as the ability to communicate with Liebert's SiteScan Web, Nform, and Trellis Site Manager monitoring system or a building management system. The system determines the location of water on the detection cable and reports the distance from the Liqui-tect Monitoring System, in feet or meters. Within seconds of detection, the measurement is flashed on the display panel, allowing you to take prompt action to correct the leak and prevent damage. To ensure proper protection, the system continuously monitors operation, signaling system normal, leak detected and cable fault. Leaking Roof Can allow substantial amounts of water to enter the shelter over time. Unattended Facility Remote communications shelters require monitoring to protect against damaging water leaks. Flat Roof Water Penetration Standing water can make its way into the critical space, causing water damage. Flooding Water from the outside could flood the inside of the structure. Humidifier Drip pans for humidifier or air conditioning units can overflow ir not regularly checked. Plumbing Any water piping located near critical equipment poses a risk if leaks develop. Sprinkler Systems Waste Systems Condensate Piping Chilled Water Piping Condenser Water Piping Room Located Below Grade Areas located below ground level are subject to water seepage from outside as well as leaks from the floor above. Clogged Drain Drainage systems designed to remove water can become a serious liability if blocked or otherwise closed. 2

LIEBERT LIQUI-TECT Liebert Liqui-tect LP3000 and LP6000 - Your Best Solution for Leak Detection Liebert leak detection systems deliver quick and accurate notification at the first sign of trouble. They also offer the ability to interface with your monitoring and building management systems to provide the broadest possible range of communication. Liebert Liqui-tect leak detection systems provide accurate reporting of leaks below the floor, above the ceiling or at the perimeter of a room in critical facilities. These reliable systems provide immediate warning and precise location, allowing you to find and correct a leak before moisture can damage computers, wiring connections or other sensitive electronics. Both solutions can: Configure up to 32 virtual zones Send direct email alarm notification Access the device remotely via the robust web interface Liebert Liqui-Tect LP3000 Liebert Liqui-Tec LP6000 The Liqui-tect LP3000 is a complete monitoring system that monitors and notifies the presence of water and other conductive fluids. The LP3000 is an advanced controller that operates in conjunction with Liqui-tec tleak detection cable. With the LP3000, the user can establish virtual zones allowing the leak detection cable to be segmented by user defined areas. The LP6000 monitors leaks the same way as the LP3000 and has a LCD touch screen that allows the user to configure, monitor, locate, and acknowledge leaks from the front panel.the LP6000 comes with an easy to read interface that helps users quickly and efficiently respond to leaks to protect valuable assets. With the Liebert Liqui-tect LP3000 you can: Monitor up to 5,000 feet of conductive fluid sensing cable A single interactive leak detection reference map Open protocol support for remote monitoring Compact device allows for mounting under a raised floor, wall mount or rack mounted with optional rack mounting bracket Log an extensive variety of events and alarms Liebert Liqui-Tect LP3000 Liebert Liqui-Tect LP6000 3 With the Liebert Liqui-tect LP6000 you can: Monitor up to 10,000 feet of conductive fluid sensing cable Create up to 10 interactive leak detection reference maps Single compact package that contains a touch screen LCD display Ability to centrally monitor multiple LP3000 controllers.

LIEBERT LIQUI-TECT Outstanding Features And Monitoring Versatility Leading Point and Zone Leak Detection Systems Liebert Liqui-tect zone and point leak detection systems install quickly and work simply for reliable warning of potentially hazardous water leaks. Liebert Liqui-tect 410 point sensor offers leak detection at critical points under a raised floor. Two corrosionresistant gold-plated probes detect moisture and immediately signal the monitoring system, allowing fast action to be taken before mission-critical equipment is damaged. Liebert Liqui-tect 410 Point Leak Detection Configuration Typical installation of a Liebert Liqui-tect 410 leak detection system used to monitor the condensate pan a Liebert DS precision air conditioning unit. Liebert Liqui-tect 460 zone sensor provides zone detection of leaks up to 100 feet. Designed for use with Liebert LT500Y leak detection cable, the Liqui-tect 460 is the ideal solution for perimeter sensing or serpentine coverage of small areas. Selectable modes of operation provide flexible alarming options and protection for the cable. Selectable alarm delays minimize false-positive conditions. Liebert Liqui-tect 460 Zone Leak Detection Configuration The Liebert Liqui-tect 460 uses flexible cable for zone monitoring. Here the system is shown connected directly to a Liebert DS precision air conditioning unit. Cable should be placed 2 to 6 feet away from the equipment being monitored. FEATURES Standard Dry-Contact Output Sensors are easily monitored by numerous monitoring systems and equipment such as Liebert environmental equipment via local alarm contact. Also compatible with Liebert's SiteScan Web enterprise monitoring system and third party equipment. Dual Output Relays Two independent outputs provide added flexibility to signal a local alarm panel, a remote building management system or external equipment such as a water shut-off valve. Supervised Operation Sensors constantly monitor for leaks, internal fault and power failure, warning of any abnormal conditions. Easy Installation Liebert Leak Detection Systems can be configured to match the protection needs of any site. Separate power and signal wires simplify circuitry needs. Mounting brackets allow for sensor height adjustment and leveling (Liqui-tect 410). Convenient kits are available pre-packaged with sensor, cable and hold down clips (Liqui-tect 460). 4

LIEBERT LIQUI-TECT Liebert LT500Y Leak Detection Cable The Liebert LT500Y Lead Detection Cable offers durable design for accurate sensing and the ability to read and report the exact position of the leak. Liebert leak detection cables have a multi-wire design for precise identification of moisture and signaling. Rugged durable materials resist corrosion and abrasion for long cable life. The cable s non-kink design makes it easy to position around equipment. After a leak is corrected, the cable sheds liquid quickly for an easy return to normal conditions. Liebert LT500Y leak detection cable is designed for easy installation and unlike other leak detection cables does not exhibit memory. This means that the installation goes in easier and does not require additional attention to how flat the cable is laying on the floor. Leak Detection Pulling It All Together - An Overall Critical Facility Monitoring Solution Liebert Liqui-tect leak detection systems are designed to work seamlessly with The Trellis Platform s Site Manager, Liebert's SiteScan Web enterprise monitoring system and Liebert Nform. Each of these solutions are a web-based site monitoring and control solution for computer support equipment and other critical facility applications. The Liebert interface hardware allows connection of the leak detection controls to the enterprise monitoring system. The Trellis Platform Site Manager provides graphical representation on 2-dimentional and 3-dimensional floor plans as well as centralized alarm management for monitoring and reporting leak alarms. Liebert's SiteScan Web monitoring system can graphically represent your leak detection layout in 2-dimensional and 3-dimensional floor plans. Liebert s Nform provides a centralized alarm management for monitoring and reporting leak alarms.notifications, logging and management of alarm conditions for the entire facility are configured and managed from a central location reducing support time. 5

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. SL-31019 (R05/17)