Smoke Sensor w/escape Light. Do not use this sensor in hazardous (classified) locations or life safety applications.

Similar documents
Flood Sensor - Cable. Power Port. Front

Sound Light & Entry Sensor (RMA-SLE-SEN) Installation Note

Smoke Alarm User s Manual

USER S MANUAL SMOKE ALARM

USER S MANUAL. BATTERY POWERED PHOTOELECTRIC SMOKE ALARM WITH SILENCE FEATURE Models 710E, 710LE and SA710CE

WIRELESS PHOTOELECTRIC SMOKE ALARM

USER S MANUAL SMOKE AND FIRE ALARM

User s Manual SPECIAL COMPLIANCE CONSIDERATIONS INSIDE THIS MANUAL LIMITATIONS OF SMOKE ALARMS. Double Sensor Smoke Alarm Cat.

AVTECH. Digital Active Power Sensor. Installation Note

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Heat Alarm User s Manual

V-MUL-033(A0) RADIOLINK BASE

Smoke Alarm User Manual

RMS-I-DE-01 Smoke Detector

PHOTOELECTRONIC SMOKE DETECTOR

SMOKE & HEAT DETECTOR

USER S MANUAL SMOKE ALARMS

INSTALLATION AND OPERATION MANUAL

USER S MANUAL SMOKE AND FIRE* ALARMS

RADION smoke RFSM-A. en Installation Guide

USER S MANUAL WIRELESS ONELINK AC POWERED SMOKE ALARM WITH BATTERY BACK-UP

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

USER S MANUAL SMOKE ALARMS

Can I Interconnect Smoke Alarms and Carbon Monoxide (CO) Alarms?

Zigbee Smoke Sensor PSG03

CONFORMS TO UL STD 217. Model P900

SMOKE DETECTOR USERS GUIDE SMOKE DETECTOR SETUP GUIDE

Operating instructions for the radio heat detector GS412

MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR DÉTECTEUR DE FUMÉE PHOTOÉLECTRIQUE SUPERVISÉ SANS FILS. Model: EL-2703

Smoke Alarm User s Guide

Smoke Alarm User Manual

Smoke Alarm. 120V AC Ionization. Smoke Alarm. Back-up. with 9V Battery

Invensys Controls Americas

1. Safety instructions Mounting location in rooms of the heat detectors... 3

1 Introducing Eve Smoke

ESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601

_V4:_ :28 AM Page 1. For model 29D,29HD. Photoelectric Smoke Alarm. User Guide

Red Alarm Indicator Light

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Smoke Alarm User s Guide

120V AC Smoke Alarm with 9V Battery Back-up

_EN_V4:_ :46 AM Page 1 USER S MANUAL 0086-CPD

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

Smoke Alarm User s Guide

Electronic Smoke Detector m-rmf150

Firehawk Fire Alarms Battery Powered. Information, Installation and Maintenance

Photoelectric Smoke Alarm User s Guide

LSI-601 / LSO-601 User Manual. Smoke Alarm Standard / Toast Proof with Ultra Bright Escape Light

Operating instructions for the wireless smoke alarm detector type: GS558

BASIC FEATURES Smoke & CO Combo Alarm Separate sensors detect smoke and CO. The two alarm systems work independently. However, in operation, the

Smoke Alarm User s Guide

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

IMPORTANT SAFETY INFORMATION PLEASE READ AND SAVE THESE INSTRUCTIONS

Photoelectric Smoke Alarm

Smoke Alarm User s Guide

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Wall Mount Electric Fireplace

169MHz Telecare Devices Heat Detector

SMOKE ALARMS City of Grand Rapids Building Safety Division

ELECTRIC FLAT PANEL FIREPLACE HEATER

Operating Instructions Version 1.2

CARBON MONOXIDE DETECTOR, i4h-co-m330

Dear Tech-Man Subscriber:

Smoke Alarm User s Guide

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

MODEL MDS300, MDS300L MODEL MDS500, MDS500L. IoPhic SMOKE & FIRE ALARM WITH SILENCE FEATURE AND ALARM ORIGINATION FEATURE

1125 PIR Motion Detector

Smoke Alarm User Guide

Question: How do the First Alert OneLink alarms communicate with each other?

Heat Alarm. Owner s Manual. Model CFH10. Rate of Rise Temperature Sensing Selectable Fixed Temperature Sensing Proprietary Wireless Connectivity

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

Smoke Alarm User s Guide

169MHz Telecare Devices. Gas Detector

OWNER S MANUAL FLAT PANEL FIREPLACE HEATER. Model Numbers: Rossano (EF113US) WARNING CAUTION

USER MANUAL 10 YEAR LIFE SMOKE ALARM

1161/1162 Residential Wireless Detectors

Visit Us on the Web! MODEL SS-795 EARLY WARNING SMOKE & FIRE ALARM WITH SILENCE CONTROL

Wireless Interlink Smoke Alarm + 10 Year Life

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

Datasheet CALYPSO II R. Interlinkable smoke alarm device

U S E R M A N U A L UBH1RF HEAT ALARM

MODEL FCD3N User s Manual Battery-Operated Carbon Monoxide Alarm

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

Battery Powered Smoke & Heat Alarms EIB600 Series

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

_V1.qxd:_ :27 AM. Ionisation Sealed Smoke Alarm with Ten Year Lithium Battery & Hush. Manual. Model Q910

1161/1162 Residential Wireless Detectors

MODEL MP316S PHOTOELECTRIC SENSING TECHNOLOGY SMOKE & FIRE ALARM WITH 10 YEAR PERMANENT POWER SEALED BATTERY

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

Thank. Document NO.: RD-559B

50 FLAT PANEL BUILD IN ELECTRIC FIREPLACE

INSTALLATION AND USER MANUAL

USER S GUIDE. Smoke Alarm. Battery-powered

ONLY WORKING SMOKE ALARMS SAVE LIVES

NO VENTING REQUIRED 120V AC;

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Transcription:

AVTECH Smoke Sensor w/escape Light AVTECH s Smoke Sensor w/escape Light is a batterypowered smoke detector with additional electronics that allow it to interface with Room Alert as a switch sensor; you may set up and receive alerts remotely when the switch state changes to assist your IT staff in monitoring and protecting your valuable IT equipment. The Smoke Sensor monitors the air, and when smoke reaches its sensing chamber, it alarms. This unit will not sense gas, heat, or flame. Smoke Sensor Package Contents One (1) Smoke Sensor One (1) 25' speaker cable One (1) 9V alkaline battery Two (2) mounting screws with two (2) plastic screw anchors Smoke Sensor Installation Note Mounting Bracket Escape Light Swing-out Battery Compartment Test/Silence Button Install Your Smoke Sensor Do not use this sensor in hazardous (classified) locations or life safety applications. Do not use this sensor as a substitute for a complete fire detection system. Attach the Smoke Sensor directly to wallboard or flat wall or ceiling surface. Do not attach the Smoke Sensor to an electrical junction box as this may impair the sensor s operation. AVTECH Software, Inc. Temperature & Environment Monitoring... Made Easy! AVTECH.com

Before you begin: Read Avoid These Locations in this document for placement recommendations. Step 1: Attach the included Mounting Bracket to the ceiling (or wall). 1. Remove the mounting bracket from the Smoke Sensor base by holding the Smoke Sensor and twisting the mounting bracket clockwise (right). (Set the unit aside where it won t get covered with dust when you drill mounting holes later.) 2. Hold the mounting bracket against the ceiling (or wall) and mark the center of each of the mounting slots with a pencil. 3. Using a 3/16" (5 mm) drill bit, drill a hole through each pencil mark. 4. Insert the included plastic screw anchors into the holes. Tap the screw anchors gently with a hammer, if necessary, until they are flush with the ceiling or wall. 5. Tighten the included screws into the screw anchors. Step 2: Activate the included battery. Your Smoke Sensor ships to you with the battery in backwards to prevent the sensor from alarming during transit. To activate the battery: 1. Open the Battery Compartment of the Smoke Sensor. 2. Re-insert the battery so its terminals match the terminals on the Smoke Sensor: match + to + and - to -. Push the battery in until it snaps in securely. (Note that the Smoke Sensor may beep briefly when you install the battery.) 3. Close the Battery Compartment. Step 3: Attach the Smoke Sensor to the mounting bracket. Position the base of the Smoke Sensor over the mounting bracket and turn clockwise (right) until the unit is in place. Do not paint over the Smoke Sensor. Paint may clog the openings to the sensing chamber and prevent the unit from operating properly. Step 4: Test your Smoke Sensor See Test Your Smoke Sensor in this document for instructions. AVTECH Software, Inc. Page 2 AVTECH.com

Step 5: Connect your Smoke Sensor to Room Alert. Do not connect the switch sensor inputs (dry contacts) on AVTECH products to any live circuit. Use only low-voltage 2-wire cable to connect switch sensor inputs. Your Smoke Sensor comes with one end of the 25' speaker cable already attached. Follow these steps to attach the other end to a switch port on your Room Alert: 1. Separate and strip the leads on the free end of the speaker cable, exposing about ¼" of wire. 2. Run the speaker cable back to your Room Alert. Try to avoid running it near large electromagnetic devices or fluorescent lights, which produce EMI and can interfere with sensor readings. 3. Connect the free ends (the 1/4" leads) of the speaker cable to an open switch port on your Room Alert. Be sure the bare wire, not the insulation, connects to the port. The leads are non-polarized, so you may connect either lead to either side of the open port. Avoid These Locations Over an electrical junction box Do not install this unit over an electrical junction box. Air currents around junction boxes can prevent smoke from reaching the sensing chamber and prevent the unit from alarming. Where combustion particles are produced Combustion particles form when something burns. Areas to avoid include poorly ventilated kitchens, garages and furnace rooms. Keep the Smoke Sensor at least 20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater, space heater) if possible. In areas where this distance is not possible, place the Smoke Sensor as far from these fuel-burning sources as possible. The placement recommendations are intended to keep the Smoke Sensor at a reasonable distance from a fuel-burning source, reducing unwanted alarms. In air streams near kitchens Air currents can draw cooking smoke into the sensing chamber of a Smoke Sensor near the kitchen. AVTECH Software, Inc. Page 3 AVTECH.com

In very damp, humid or steamy areas, or directly near bathrooms with showers Keep units at least 10 feet (3 meters) away from showers, saunas, dishwashers, etc. Where the temperatures are regularly below 40 F (4.4 C) or above 100 F (37.8 C) In very dusty, dirty or greasy areas Do not install a Smoke Sensor directly over the stove or range. Keep laundry room Smoke Sensors free of dust or lint. Near fresh air vents, ceiling fans or in very drafty areas Drafts can blow smoke away from the unit, preventing it from reaching the sensing chamber. In insect infested areas Insects can clog openings to the sensing chamber and cause unwanted alarms. Less than 12 inches (305 mm) away from fluorescent lights. Electrical noise can interfere with the sensor. In dead air spaces. Dead air spaces may prevent smoke from reaching the Smoke Sensor. To avoid dead air spaces: On ceilings, install Smoke Sensors as close to the center of the ceiling as possible. If this is not possible, install the Smoke Sensor at least 4" (102 mm) from the wall or corner. For wall mounting (if allowed by building codes), place the top edge of the Smoke Sensor between 4" and 12" (102 and 305 mm) from the wall/ceiling line, below typical dead air spaces. On a peaked, gabled or cathedral ceiling, install the first Smoke Sensor within 3' (0.9 meters) of the peak of the ceiling, measured horizontally. Additional Smoke Sensors may be required depending on the length, angle, etc. of the ceiling s slope. Maintain Your Smoke Sensor Test your Smoke Sensor Test your Smoke Sensor at least once a week. To test, hold down the Test/Silence Button until the alarm sounds and the Escape Light AVTECH Software, Inc. Page 4 AVTECH.com

turns on: A loud, repeating horn pattern will sound: 3 beeps, pause, 3 beeps, pause, etc. The Escape Light will turn on. The LED on the Test/Silence Button will flash once every second. The sensor may continue to alarm for a few seconds after you release the Test/Silence button. If the alarm does not sound during testing, try installing a new battery, and make sure it is snapped in securely. If it still does not alarm, replace the sensor immediately. If the Escape Light doesn t light during testing, make sure the bulb is working properly. If you suspect the bulb is burned out, it is not replaceable. Clean your Smoke Sensor Clean the Smoke Sensor at least once a month. You may gently vacuum the outside of the Smoke Sensor using your a vacuum s soft brush attachment or use a can of clean compressed air. Do not use water, cleaners or solvents as they may damage the unit. If the Smoke Sensor becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately. Relocate your Smoke Sensor if necessary Relocate the unit if it sounds frequent unwanted alarms. See Avoid These Locations in this document for more information. Replace the battery When the battery becomes weak, the Smoke Sensor unit will chirp about once a minute, which is the low battery warning. The low battery warning should last for 30 days, but you should replace the battery immediately. Use only the following replacement batteries: Duracell #MN1604, (Ultra) #MX1604, U9VL- J-P. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge. Replace Your Smoke Sensor Replace your Smoke Sensor immediately if it is not operating properly. Replace your Smoke Sensor 10 years from date of purchase. You may write the purchase date on the space provided on back of unit. AVTECH Software, Inc. Page 5 AVTECH.com

The Silence Feature The Silence Feature can temporarily quiet an unwanted alarm for several minutes. To use this feature, press the Test/Silence button on the cover. The Escape Light will turn off and the LED will flash every 10 seconds (for up to 10 minutes) to remind you the alarm has been silenced. Do not stand too close to the unit when the alarm is sounding. Exposure to the horn at close range may harm your hearing. Sensor Features & Specifications Environment Condition Monitored Smoke Type Of Sensor Switch Normal State Open (Smoke Sensor not triggered) Alarm State Closed (Smoke Sensor triggered) Power Supply 9V alkaline battery Sensor Cable Type Low-voltage two-wire speaker cable Included Yes Length 25' Maximum Extendible Length 900' Operating Temperature 40 F (4.4 C) to 100 F (37.8 C) Compatible Products Any Room Alert model or Wireless Sensor Hub AVT-171211-1.1.0 AVTECH Software, Inc. Page 6 AVTECH.com

Configure Your Switch Sensor Configure Your Switch Sensor Use Room Alert s Built-In Web Interface Navigate to Settings Sensors in your Room Alert web interface. The options you see below will vary depending on your Room Alert model. 1. Scroll down to Switch Sensor Settings. 2. Find the switch sensor label that matches the port you connected your switch sensor to. For example, if you used the first switch sensor port on your Room Alert, look for Sensor 1 Label; if you used the second, look for Sensor 2 Label, and so on. 3. In Sensor X Label, you may leave the default, Switch Sen X, or enter something more descriptive of up to 15 characters. You may use the following characters in sensor labels: letters, numbers, spaces, hyphens (-), underscores (_) and periods (.). 4. In Alarm On, select the alarm state (Open or Closed) for your switch sensor. You may find the alarm state of your switch sensor under the Features & Specifications section of this Installation Note. 5. In Alarm Profile, which controls light towers and relays on your Room Alert, you may leave the default, Profile 1, or choose another profile from the drop-down menu. 6. Select Save Settings at the top or bottom of the page. Your Room Alert will automatically reboot and commit your changes. AVT-171211-1.1.0 AVTECH Software, Inc. Page 7 AVTECH.com