Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Similar documents
Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

BRISE. Heating and cooling from a single radiator

Brochure EX

BRISE. Super-power for heating, cooling and ventilation.

Brise The most powerfull heating

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Fan coil unit KL. Wall unit Ceiling unit

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

BOOST INTO THE FUTURE

Technical documentation Fan coil unit

Cassette units Model Comfort Circle. - heating - cooling - ventilation

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

NEW GREEN TECHNOLOGY

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Cooling Strip Model SPB

Packaged air conditioners vertical units

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18.

Quatro canal Super-powered climate control for 4-pipe systems

QZHW Fan Coil Unit. Key features. Specifications

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

QZB "Standard" comfort fan coil

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Blower-YEFB-020-3R-1maxVel

CASSETTE UNIT. Comfort Circle

TopVent Design Handbook

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

KPSW CONSOLE TERMINAL UNIT

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

HT V2 HT Split

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Play DBE. Colourful, fun, safe. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

SERIES BM. Concealed Fan Convector

CONTENT: VEX308 Decentralised ventilation VEX308

FREEDOM 2019.EX CZ - 21/11/18

CLIMACIAT AIR COMPACT

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

SLIM-LINE RC FAN CONVECTOR.

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

BRIZA Super slim and powerful heating, cooling

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Power X High Power Condensing Wall-Hung Boilers

WOLF VENTILATION SYSTEM PRICE LIST

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

Original instructions AR

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Type CODE Speed Heating Cooling

Fan coil units with centrifugal fan

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Power X High Power Condensing Wall-Hung Boilers

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Blarenberglaan 21 B 2800 MECHELEN Tel.: +32 (0) Fax: +32 (0)

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Primo Hotel. General. Indoor climate units for hotel rooms

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

INSTALLATION AND OPERATING MANUAL

SUPPLEMENTARY INSTRUCTION BOOKLET HEATER TYPE TR. Centrifugal / Rooftop

Metropolitan high output natural and powered trench heaters

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

... UDSA - UDSBD Gas fired unit heaters...

Fan heater SWT Ceiling mounted fan heater with water heat

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

Air/water - Heat pumps

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

FINESSE. Full manual INSTALLATION. VCF-B-xxx-... VCF-C-xxx-... B

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Transcription:

4 4 6. -speed speed control. RIC ceiling model. RIW wall model 4. RW wall build-in model. grille from AS 6. ow-ho element

_ Wall mounted model : Wall Wall mounted model RIF: RIse Free-standing Free-standing model RW: Rise uild in Wall uilt in wall mounted model Dimensions RIW: Wall RW: uild-in Wall D C F E. 6.8.7 8 Ø Speed control 0--- A 7 9.8 D C F E min. 0 0 6.8.7.0 8. Ø. H min 0 6. 9. 9. min 0 9 RIF RIW + feet + rear panel. Feet can be used as a cover plate for connection tubes for the electrical circuit and hydraulic connections. The model RW may also be fitted horizontally when it will only be used for heating. Provide an air vent on the central heating tube. Dimensions in cm A 8. 8. 0.0 0.0 7. 6.0.0.0.0.0 7. 7. C 4. 4. 4. 4. 4. 4. D...... E 4. 4. 4. 4. 46. 46. F.... 6.0 6.0.7.7 8. 8. 0.7 8. H 7. 7. 8. 8..7 40. Conn. heat exchanger / / / /4 /4 /4 conn. air vent /8 /8 /8 /8 /8 /8. Heat exchanger. Condensation tray. Fan(s) 4. not recyclable air filter (option) 6. Air exhausting grille 7. Switch 8. Additional Condensation tray (option) 9. Casing 0. Holes for fixing to the wall Weight in kg: 0 0 04 06 08 0 RIW (with casing) 8.0 9.0 4.0 6.0 8.0 0.0 RW (without casing) 4.0 4..0 0..0 4.

_Ceiling-mounted model RIC: RIse Ceiling ceiling mounted model RC: Rise uild-in Ceiling built in ceiling mounted model Dimensions RIC: Ceiling RC: uild-in Ceiling C (*) 0.. cm F E. D 6.8.7 A 7 9.8 6.8 6 Max. height of the ceiling:.80 m. (*) Fit the ventilo-fan convector with a slight inclination to facilitate the drainage of the condensation water. The model RIC or RC may also be fitted vertically, when it will only be used for heating. Provide an air vent on the central heating tube. (*) 0.. cm 9 F. E.7 0 (*) 0.. cm min 0 option air inlet grille F E 0 0 C D.0 6.8 8..7 C D I J option corner piece and air exhausting grille.4 H 4.7 Option air inlet grille: do not mount it to close to the brise to avoid that the exhausted hot air will be sucked in again. Dimensions in cm A 8. 8. 0.0 0.0 7. 6.0.0.0.0.0 7. 7. C 4. 4. 4. 4. 4. 4. D...... E 4. 4. 4. 4. 46. 46. F.... 6.0 6.0.7.7 8. 8. 0.7 8. H 7. 7. 8. 8..7 40. I 6. 6. 6. 6. 4.0 4.0 J...... Conn. heat exchanger /" /" /" /4" /4" /4" conn. air vent /8" /8" /8" /8" /8" /8". Heat exchanger. Condensation tray. Fan(s) 4. ot recyclable air filter (option). Air inlet grille 6. Air exhausting grille 9. Casing 0. Holes for fixing to the ceiling Weight in kg: 0 0 04 06 08 0 RIC (with casing) 8.0 9.0 4.0 6.0 8.0 0.0 RC (without casing) 4..0 0.0.0.0 4.

standard m o d e l S iz e 0 0 0 4 0 6 0 8 0 RIW CODE RIW.0 RIW.0 RIW.04 RIW.06 RIW.08 RIW.0 w RIF CODE RIF.0 RIF.0 RIF.04 RIF.06 RIF.08 RIF.0 f RW CODE RW.0 RW.0 RW.04 RW.06 RW.08 RW.0 b RIC CODE RIC.0 RIC.0 RIC.04 RIC.06 RIC.08 RIC.0 c RC CODE RC.0 RC.0 RC.04 RC.06 RC.08 RC.0 b Additional electric element ominal power watt 000 000 000 000 000 000 Electric connection V - f - Hz 0--0 0--0 0--0 0--0 0--0 0--0 CODE 87.60.60.604.604.60.606 E Options are fitted when fan convector and options are ordered together. With built-in options, delivery time will be longer. Inclusive security thermostat. Do not combine with n d heat exchanger 4. Allow the air flow during the functioning of the electric element. Second heat exchanger 4 Heat output 4 at ΔT 0 kw max..07.8.8.6 9. 0.6 7/6 C - 0 C med..86.7.4.06 7.7 9.8 min..7.7.9 4.8 7.0 8.09 Heat output 4 at ΔT 60 kw max..48.4 4.60 6.76.07.78 90/70 C - 0 C med...08 4.4 6.08 9.6.0 min..88.60.0.4 8.4 9.7 Water content 4 litre 0. 0.7 0.44 0.6.4.4 CODE 87....4..6 E b a Second heat exchanger 4 for connection of warm water Options are fitted when fan convector and options are ordered together. With built-in options, delivery time will be longer. With second heat exchanger, the standard heat exchanger has to be used for cooling and the second heat exchanger for heating. Connection for cool Dimensions in cm water c d a 9.0 9.0 9.0 9.0 9. 9. b 9.8 9.8 9.8 9.8 4.0 4.0 c 8.0 8.0 8.0 8.0.. d 48.0 48.0 48.0 48.0 48.0 48.0

_ Technical data Heat output at ΔT 0 kw max. 4.00.6 8.07. 9.48.0 7/6 C - 0 C med..60.00 7.6 0.8 6.78 8.9 min..04 4. 6. 8.76 4.7.97 Heat output at ΔT 60 kw max. 4.80 6.67 9.69.84.8. 90/70 C - 0 C med. 4. 6.00 8.7.46 0.4.7 min..6.07 7.6 0. 7.0 9.7 Total cooling capacity at kw max..6.8.7 4.88 8.0 9.97 7/ C - C D.. - % RV med..47.0.0 4.9 7. 8.79 min..4.7.6.7 6.0 7.40 Perceptible cooling capacity at kw max..6.67.40.0.80 6.90 7/ C - C D.. - % RV med..04.0.6.. 6. () min. 0.88.7.8.66 4.4.4 Air flow m /u max. 80 00 700 880 0 700 med. 9 90 4 690 00 min. 0 90 40 0 70 9 Sound level weighted d(a) / R max. 4/6 47/4 44/9 0/46 0/4 /0 frame of reference.0 - Pa med. / / 6/ 7/ 4/8 4/8 () min. 9/ 9/6 0/6 /7 /0 7/ Sound output level d HZ max. / med. / min. 48/4/4 /46/4 49/44/8 /4/8 /49/4 8/0/46 frame reference 0 - w HZ 0 max. / med. / min. 46/44/9 /4/40 0/4/8 /44/9 7/0/4 60//46 HZ 00 max. /med./min. 46/40/ /4/6 49/4/6 6/4/7 4/47/40 7/0/44 HZ 000 max. /med./min. 4/6/0 47/7/ 49/7/ /8/4 /44/ /46/40 HZ 000 max. /med./min. 7/0/ 44// 9/0/4 46/0/ 47/9/0 /44/4 HZ 4000 max. /med./min. /6/ 40/7/ 6/6/ 4/7/ 4/6/7 47/8/9 HZ 8000 max. /med./min. /4/0 7/6/0 //0 7/6/ 4/0/ 9/9/7 Electric connection V - f - Hz 0--0 0--0 0--0 0--0 0--0 0--0 Water content litre 0.66 0.86.4.96.7 4.0 umber of fans () umber of motors Capacity condenser μf.... Mesured power Watt 4 68 0 9 0 Mesured current A 0. 0. 0.48 0.9 0.9 0.99 Throw distance approximate values at maximum speed (4) m 4 6 7 9 7 () ormal calculation and selection at noticeable cooling capacity and preferably at medium speed. () Measured model: model RIW with casing and standard heat exchanger. Height: m from the air exhaust grille. The sound level is influenced by the dimensions of the room, the reverberation time and other sound sources. () Centrifugal fan(s) with motor (0 - - 0 Hz) with continuously directed condenser. Safety with automatical reset. IP 4. Earthing supplied. Rollers. (4) As is the case with almost all dynamic data these distances depend on how the appliances are mounted and how they are placed. Channels or connections tend to influence distance and debit to a large extent.

_Options Filter Dimensions x x x x80. x80. x08 x. CODE 87......6 Recyclable air filter (standard at RIW and RIF, option at RIC, RW and RC) Speed control Idem for each size CODE 876.0000 Position 0--- for wall mounting. per fan convector or regulator for several fan-coils in combination with relay-contacts (see page ). In both cases the already incorporated speed regulators of the RIW/RIF should be disconnected! Speed control / thermostat Rear panel for model RIW COT AUTO 0 0 0 C Idem for each size CODE 876.0000 Thermostat for wall mounting, with on/off switch and position fan speed control. Suited for heating, cooling or ventilation. With continuous or automatically fan speed control. per fan or regulator for several fan-coils in combination with relay-contacts. (see p. 6). CODE 8770......6 For free-standing models also order feet. Feet for model RIW - RW Inclusive protective cover. CODE 8767.4.4.4.4.. Fan-seal panel for model RIC CODE 877......6 For visible mounting. Seal panel in the same colour as the radiator. Fan-seal panel for model RW - RC CODE 877.00.00.00.00.00.006 For air intake at side and as air-conducting compartments. With built-in models always order.

_Options Condensation tray for model RIW - RIF - RW CODE 8769.004.004.004.004.00.00 Additional condensation tray for cooling. Position underneath the valves. Transformation to exhaust downwards for model RIC CODE 8774.......00.00.00.006 Inclusive fan-seal panel for RIC. Maximum height of ceiling:.6 m. Maximum fitting height:. m. Only available when ordering with the appliance 0 60 Plenum with connection ø. cm for model RC CODE 8764....0.0.0.0.0.06 Exhaust plenum for connection of one air channel. Maximum length of the channel metre, without loss of debit. Plenum with connections ø6 cm for model RC A CODE 8764....0.0.0.0.0.06 Exhaust plenum for connection of two air channels. Maximum length of the channel metre, without loss of debit.

_ Air mixing box RIW_ Wall. Servo motor. Air mixing box. Air inlet grille RC_ uild-in Ceiling. Air mixing box. Corner piece with adjustable air exhausting grille Fan-seal panel 4. Adjustable air inlet grille 4

_ Air mixing box Air mixing box 90 for model RIW - RW - RC CODE 8784.00.00.00.00.00.006 Always order a fan-seal panel at model RW and RC (code 877). Manual controlled 0-00% MODE RIF: the air mixing box does not fit between the feet. For a freestanding model: order model RIW, rear panel and air mixing box. 90 C 80 C 90 C Air mixing box 80 for model RIW - RW - RC CODE 876.00.00.00.00.00.006 h 7 7 h H Manual controlled 0-00% 80 C H 0,0 0,0 0,0 0,0,0,0 46,0 46,0 7, 7, 0,0 8, h,,,,,, Air inlet grille for air mixing box model RIW - RW atural anodized aluminium. CODE 8766.00.00.00.00.00.006 Adjustable air inlet grille for model RC min.. max.. Dimensions x.7 x 6.7.7 x 6.7.7 x 84..7 x 84..7 x.7.7 x 9. CODE 877.00.00.00.00.00.006 atural anodized aluminium. -4.4 Adjustable air exhausting grille for model RC min.. max.. atural anodized aluminium. -4.4 Corner piece with adjustable air exhausting grille for model RC -4.4 Dimensions x. x 6.7. x 6.7. x 84.. x 84.. x.7. x 9. CODE 877.00.00.00.00.00.006 Dimensions x.7 x 6.7.7 x 6.7.7 x 84..7 x 84..7 x.7.7 x 9. CODE 8780.00.00.00.00.00.006 Always order a fan-seal panel at model RW and RC (code 877).

_ Servo motors for air mixing boxes Order Servo motor and/or thermostat for frost protection together with the air mixingbox (pre-mounted delivery). Servo motors on/off CODE Drawing Description with return spring 878.0 Servo motor on/off-0 V 878.0 Servo motor on/off - 0 V with return spring 878.40 Servo motor on/off - 4 V with return spring 878.04 8/9 Servo motor on/off-0 V for switch box 87.07000 and 87.07000 Servo motors modulating CODE Drawing Description 878.0 Servo motor modulating - 0 V 878.40 6 Servo motor modulating - 4 V 878.40 7 Servo motor modulating - 4 V with return spring with return spring Switch boxes for servo motors CODE Drawing Description 87.07000 8 Switch box open/closed for servo motor 878.04 87.07000 9 Switch box open/middle/closed, incl. second switch, for servo motor 878.04 Thermostat for frost protection CODE Drawing Description 87.0000 0 Thermostat for frost protection (from -0 up to + C) Diagrams 6 / 7 AC 4 V DC 4 V Servo motor Servo motor Servo motor Servo motor Servo motor T + ~ Y U servomotor Servo with return spring 8 9 0 FS 8 7 6 4 FS 8 7 6 0 4 4 4 JTF Servo motor PE JTF PE s s s s4 s s6 SMOA Servomotor SA

_ Electric connection Use switch with speeds per fan convector. Connect more ventilos at one switch, OY by using COECTORS. (see drawing). Model RIW Standard supplied with an integrated three speed control 0--- Model RIC / RW / RC With wall mounted speed control 0--- speed control per R E VET. V O Z R R C.0 μf / type -. μf / type 4-6. μf / type 8-0 7. R E VET. V O Z R R C.0 μf / type -. μf / type 4-6. μf / type 8-0.7 S 4 d a 7. - code : 876.0000 S 4 c d FS FS 0 V ~ 0 Hz 0 V ~ 0 Hz FS S Mains connection: safety fuse max. 0 A Speed control speed control for several s. R E VET. V O Z R R R E VET. V O Z R R C.0 μf / type -. μf / type 4-6. μf / type 8-0 C.0 μf / type -. μf / type 4-6. μf / type 8-0 0 V ~ 0 Hz S FS 4 c d FS S Mains connection: safety fuse max. 0 A Speed control

Model RIC / RW / RC With wall mounted thermostat heating/cooling, with speed control.8.9 thermostatic per R E VET. V O Z R R 7. C.0 F / type -. F / type 4-6. F / type 8-0 - CODE : 876.0000 R E () () () FS 0 V ~ 0 Hz VET. C.0 mf / type -. mf / type 4-6. mf / type 8-0 0 4 6 COT/AUTO thermostatic for several s V O Z R R R E S VET. Acc V O Z R R C.0 mf / type -. mf / type 4-6. mf / type 8-0 FS Mains connection: safety fuse max. 0 A S Speed control : 4 exit heating/cooling (continuous) exit heating (auto) 6 exit cooling ( auto) thermostatic function accelerator heater O/OFF switch heating ventilation cooling () heating or cooling by the standard heat exchanger on a hydraulic heating system. () heating and cooling by the standard battery and second heat exchanger in separate circuits. () () () 0 4 6 COT/AUTO Acc < S FS 0 V ~ 0 Hz

_Correction factors Average correction factors according 7/6/0 C Tv Tl Tr > 0 0 40 4 0 60 6 70 7 80 8 90 0 0.70 0.7 0.80 0.8 0.90 0.9.00.0.0..0..0. 4 0.6 0.67 0.7 0.77 0.8 0.87 0.9 0.97.0.07..7.. 8 0 0.6 0.70 0.7 0.80 0.8 0.90 0.9.00.0.0..0. 4 0.7 0.6 0.67 0.7 0.77 0.8 0.87 0.9 0.97.0.07..7 80 0 0.60 0.6 0.70 0.7 0.80 0.8 0.90 0.9.00.0.0. 4 0. 0.7 0.6 0.67 0.7 0.77 0.8 0.87 0.9 0.97.0.07 7 0 0. 0.60 0.6 0.70 0.7 0.80 0.8 0.90 0.9.00.0 4 0.47 0. 0.7 0.6 0.67 0.7 0.77 0.8 0.87 0.9 0.9 70 0 0.0 0. 0.60 0.6 0.70 0.7 0.80 0.8 0.90 0.9 4 0.4 0.47 0. 0.7 0.6 0.67 0.7 0.77 0.8 0.87 6 0 0.4 0.0 0. 0.60 0.6 0.70 0.7 0.80 0.8 4 0.7 0.4 0.47 0. 0.7 0.6 0.67 0.7 0.77 60 0 0.40 0.4 0.0 0. 0.60 0.6 0.70 0.7 4 0. 0.7 0.4 0.47 0. 0.7 0.6 0.67 0 0. 0.40 0.4 0.0 0. 0.60 0.6 4 0.7 0. 0.7 0.4 0.47 0. 0.7 0 0 0.0 0. 0.40 0.4 0.0 0. 4 0. 0.7 0. 0.7 0.4 0.47 4 0 0. 0.0 0. 0.40 0.4 4 0.7 0. 0.7 0. 0.7 40 0 0.0 0. 0.0 0. 4 0. 0.7 0. 0.7 0 0. 0.0 0. 4 0.07 0. 0.7 0 0 0.0 0. 4 0.0 0.07 Example The indicated outputs with ΔT 0 are the exact outputs. An average correction factor is given in the table above for all other ΔT outputs, applicable for all dimensions. Tv flow temperature Tr return temperature Tl desired air temperature Example Select a of 000 Watt at: Tv 7 C, Tr 6 C and Tl 0. When you want to know how these delivers up at Tv0 C, Tr40 C and Tl4 C. In the table you can see the factor 0.4 with these temperatures. The radiator would therefore deliver up on this temperature (0.000 x 0.4) 40 Watt. Example You want to select a that delivers up 0.000 Watt by Tv 0 C, Tr 40 C and Tl 4. In the table you can see the factor 0.4 with these temperatures. On Tv 7 C, Tr 6 C and Tl 0 you need to select a of 0.000 : 0.4.809 Watt.

Correction factors sound level Other room volume Content (m) Pressure drop standard heat exchanger kpa 0 0 m c.a., Correction [d(a)] 80 0 0 -.7 00-4.0 0-4.9 00 -.7 0-6.4 400-7.0 00-8.0 600-8.8 Calculation of sound pressure for other local content. P P P V V P - 0 log Size 04 Size 0 Size 0 Size 06 V V table of sound level sound level to be calculated size of room of reference (80 m³) other room size Several appliances with an equal sound level in a room u mb e r C o r r e c t i o n [d(a)] +.0 + 4.8 P P P n P + 0 log n sound level one appliance sound level to be calculated number of appliances Correction factors hydraulic pressure drop Size 0 Size 08 Other reverberation time Reverbertation Time (s) T Pressure drop second heat exchanger (4) kpa 0 0 m c.a., Correction [d(a)]. + 6..0 +.. + 4.0.0 +. D i f f e r e n c e [d(a)] C o r r e c t i o n [d(a)] 0 +.0 +.8 4 +. +. 6 +.0 7 + 0.8 8 + 0.8 9 + 0.6 0 + 0. >0 + 0.4 P P - 0 log T T P table of sound level P sound level to be calculated T reverbertation time of room of reference ( T 0.6s ) T other reverberation time of room The sound level of two sound sources with different values Use this table to determine the total sound in a room with two sound sources of a different sound level (f.i. immediate air inlet and outlet in the room), one can use the following table. The correction value had to be added to the highest value. Size 06 Size 04 Size 0 Size 0 Size 0 Size 08 Pressure drop 4 0 9 8 7 6, 0,9 0,8 0,7 0,6 0, Pressure drop 4 0 9 8 7 6, 0,9 0,8 0,7 0,6 0, 4 0,4 4 0,4 0, 0, 0, 00 0 00 0 00 400 00 600 800 000 00 000 l/h 0, 00 0 00 0 00 0 400 40 00 600 700 800 l/h 0,0 0,04 0,0 0,06 0,07 0,08 0, 0, 0, 0, l/s Water flow Water flow Average water temperature 60 C.Average water temperature 60 C. Correction factors for other speeds m a x. m e d. mi n. Cf 0.9 0.76 Caution: the indicated pressure drop only applies for the heat exchanger without shields, pipes, etc...

Determination relative humidity, dry and wet bulb temperature T 0 4 6 7 8 9 0 4 C - 00 77 8.................................... 0 00 90 6 46 0.............................. + 00 8 70 4 9 7........................... 0 00 86 74 6 0 9 7 6....................... 00 87 7 6 4 9 9..................... 00 88 76 64 4 4 4.................. 00 88 77 6 4 6.................. 4 00 88 77 67 6 46 7 7 8 9.................. 00 88 78 68 8 48 9 0............... 6 00 90 78 69 60 0 4 4 6 7............... 7 00 90 80 69 60 4 4 6 8 0............... 8 00 90 80 7 6 44 7 8 0 6............ 9 00 90 8 7 6 4 46 8 0 9............ 0 00 90 8 7 64 6 47 40 8............ 00 9 8 7 6 7 49 4 7 0 4 6......... 00 9 8 74 66 8 0 4 6 9 6 9......... 00 9 8 7 67 8 4 7 8 6...... 4 00 9 8 7 67 60 46 9 6 4 9...... 00 9 8 76 68 6 4 47 4 4 8 7 6... 6 00 9 84 76 69 6 48 4 6 0 4 8 8 7 00 9 8 77 70 6 6 0 4 7 6 0 0 8 00 9 8 77 70 6 7 4 8 8 7 8 9 00 9 8 79 7 64 8 46 40 4 9 4 9 4 9 0 00 9 86 79 7 6 9 47 4 6 0 6 Example: dry bulb temperature. 4 C relative humidity 60 % T wet bulb temperature dry bulb temperature - T wet bulb temperature example 4-9 C Available atmospheric pressure and correction factors for built in RC/RW available atmospheric pressure Pa mm c.a. 0 00 90 80 70 60 0 40 0 0 0 9 8 7 6 4 Size 08 Size 04 Size 0 Size 06 Size 0 Size 0 Correction factors for other speeds m a x. m e d. mi n. Cf 0.9 0.76 0 0 0 Cf Air flow P 0,90 0,80 0,70 0,60 0,0 0,40 0,0 R 0,96 0,9 0,8 0,78 0,70 0,60 0,48 Cf Output