U n i t H e at e r s

Similar documents
True performance and rugged durability. TU, LF and LD Models

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

8+* Bulletin No November 1997

13 GEP A L P - 1 A

MERIT SERIES Downflow

RGE 13 A T - 1 A

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

G34M Bulletin #69/ August 2003

ELITE SERIES Downflow - High Efficiency Blower Motor

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

CATALOG: HVAC - Gas Space Unit Heating

SUBMITTAL SCHEDULE & DATA

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Cooling Capacity CFM in. w.c. (125 Pa)

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Cooling Capacity CFM in. w.c. (125 Pa)

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

48TM GAS HEATING/ELECTRIC COOLING UNITS

Tankless Condensing High Efficiency Water Heaters

Gas-Fired Unit Heaters Commercial & Industrial

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

TECHNICAL SPECIFICATIONS

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

G6RC Series TECHNICAL SPECIFICATIONS

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Corp L12 Revised G24M SERIES UNITS

MERIT SERIES Downflow

Downflow/Horizontal Right Induced Draft Gas Furnace

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

GARAGE / WORKSHOP INFRARED HEATERS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Wt. Lbs Model Number (BTUH) Hz

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Residential/Commercial Gas Condensing Tankless Models

Residential Gas Tankless Water Heater

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

TSTAT0101SC Recommended (order separately)

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

FORCED AIR HEATING VARIFLAME HEATERS

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

TECHNICAL SPECIFICATIONS

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

SKYPAK II, 3 Ton Series, gives you a

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

FXLF-9. High Efficiency Water Heaters and Boilers

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Transcription:

Unit Heaters LF Models

Enduring performance Allied commercial unit heaters are built to last, season after season Designed and built for durability and peak performance, Allied Commercial unit heaters incorporate advanced technology and proven materials into reliable, time-tested equipment. Compact unit heaters at a glance: Ideal for hard-to-heat applications requiring fresh air for combustion due to excessive dust, dirt and humidity or negative pressure Easy access to components through a hinged door Heat capacity ranging from 30,000 75,000 Btuh Standard unit heaters at a glance: Meet a wide range of residential and commercial heating applications Stainless steel heat exchanger available Heat capacity ranging from 100,000 390,000 Btuh Efficiency Rating Up to 81% thermal efficiency The tubular heat exchanger that is standard on all Allied Commercial unit heaters is designed to stand the test of time, delivering efficient and reliable heat. The curved design of the exchanger completely exposes the heating surface to the air stream, resulting in excellent heat transfer. This aluminum heat exchanger is also available in stainless steel on select models. Other advanced features include the easily cleaned, easy-to-reach, inshot burner assembly and permanently lubricated blower motor for minimal maintenance. By using a self-diagnostic board, Allied Commercial unit heaters offer advanced safety and troubleshooting capabilities as well. Installation is quick and simple For application flexibility, units may be vented horizontally or vertically. Tight spaces aren t an issue thanks to the low cabinet profile of the compact and standard models. For faster installation, units are fully tested at the factory, including complete start-up and shutdown cycles, as well as gas and electrical operation verification. Installation is further simplified through the use of mounting brackets or spotnuts, and centrally located connections for gas, line voltage, and thermostats. Allied Commercial units are stocked near you, allowing for quick delivery and installation. WARRANTY 15-Year Limited Warranty on stainless steel heat exchanger 10-Year Limited Warranty on aluminized heat exchanger 1-Year Limited Warranty on covered components See warranty certificate for actual details.

TWO DIFFERENT DESIGNS. ONE STANDARD OF Performance. For convenience and installation ease, Allied Commercial unit heaters come in two different configurations: standard and compact. But the flexibility doesn t stop there. Multiple heating capacities are available for convenient and efficient heating of small and large spaces. Natural gas and propane are both available as fuel sources. Several wall venting options are available, including horizontal and vertical. In short, Allied Commercial has the heater you need, how you need it. Compact Combustion Heaters Ideal for hard-to-heat applications where excessive dust, dirt or humidity or negative pressure is a concern Durable tubular heat exchanger Heating capacities from 30,000 75,000 Btuh Up to 81% thermal efficiency Compact cabinet design Hinged door allows easy access to components Sidewall venting eliminates roof penetrations Self-diagnostic board with LED display improves troubleshooting efficiency and accuracy Standard Unit Heaters Ideal for a wide range of residential and commercial applications Heating capacities from 100,000 390,000 Btuh Up to 80.5% thermal efficiency Optional stainless steel heat exchanger (for 100,000 Btuh and greater models) is available for longer product life Sidewall venting eliminates roof penetrations Self-diagnostic board with LED display improves troubleshooting efficiency and accuracy

UNIT HEATERS 1 6 11 11 8 7 5 2 4 9 3 10 10 PRECISE performance, reliability and durability Tubular Heat Exchanger Proven design for efficiency and durability. Available in stainless steel on 100,000 390,000 Btuh models. 2 Combustion Air Inducer Proving Switch Prevents unit operation if combustion air vent is blocked. 3 24V Combination Gas Control Valve with 100% Safety Shutoff Increases control and protects units. 4 Integrated Control Board with Direct Spark Ignition Improves unit operation and efficiency. 5 Limit Control Provides protection from overheat conditions. 6 Heavy-Gauge Steel Cabinet Resists corrosion and provides structural stability. Flame Rollout Sensor (not shown) Improves safety. Installation and Maintenance made easy 7 Aluminized Steel Inshot Burners Are low maintenance and easy to clean. 4 Integrated Control Board with Diagnostics Improves operation and aids in troubleshooting. 8 Hinged Door Provides easy access to components. 9 Burner View Port For easy flame viewing during routine maintenance. External Gas, Line Voltage and Thermostat Connections Speed installation. Mounting Spotnuts Allow for threaded rod installation (100,000 300,000 Btuh models). Permanently lubricated blower motor Offers minimal maintenance and solid performance. Application solutions Separated Combustion Air Inlet Provides fresh outdoor air for proper combustion.

LF24 COMPACT Unit Heater performance Specifications gas heating performance connections Fan Data** Physical data MODEL* Heating Capacity Heating Input Output Btuh Btuh [kw] [kw] LF24-30A 30,000 [8.8] LF24-45A 45,000 [13.2] LF24-60A 60,000 [17.6] LF24-75A 75,000 [22.0] 24,300 [7.1] 36,500 [10.7] 48,000 [14.1] 60,000 [17.6] steady state efficiency Temp. Rise ºF [ºC] 81.0% 42 [23] 81.0% 45 [25] 80.0% 55 [31] 80.0% 60 [33] Vert. Flue Size Round 3 1 [76] 3 1 [76] Horiz. Flue Size Round 4 3 4 3 5 4 5 4 Gas Piping Size [npt] NO. of Fans Diameter 10 [254] 4 10 [254] 4 14 [356] 3 14 [356] 3 NO. of Output Blades hp [W] *"A" denotes aluminized steel heat exchanger. All models are 115 volts, 60 hertz, 1 phase. 1 2- x 3 in. (54 x 76 mm) diameter adaptor is furnished with unit for flue connection. 2 2 x 4 in. (51 x 102 mm) diameter adaptor is furnished with unit for flue connection. 3 3 x 4 in. (76 x 102 mm) vent adaptor required (not furnished) for horizontal venting in residential applications. 4 4 x 5 in. (102 x 127 mm) vent adaptor required (not furnished) for horizontal venting in residential applications. 1/20 [37] 1/20 [37] Full Load Amps RPMs Air Vol. CFM [L/s] 1.7 50 [250] 535 1.7 50 [355] 750 4.1 1050 [390] 830 4.1 1050 [450] 950 DIMensions H X W X L [INCHES] SHIP WT. [LBS.] 13 x 25 x 24 60 13 x 25 x 24 63 18 x 25 x 25 87 18 x 25 x 25 91 LF24 STANDARD Unit Heater performance Specifications MODEL* gas heating performance connections Fan Data** Physical data Heating Capacity Output Input Natural Btuh Btuh [kw] [kw] LF24-100S 100,000 LF24-100A [114.3] LF24-115S 115,000 LF24-115A [33.7] LF24-145S 145,000 LF24-145A [42.5] LF24-175S 172,500 LF24-175A [50.6] LF24-200S 195,000 LF24-200A [56.9] LF24-230S 230,000 LF24-230A [67.5] LF24-250S 250,000 LF24-250A [73.3] LF24-300S 300,000 LF24-300A [87.9] LF24-345S 345,000 LF24-345A [101.1] LF24-400S 390,000 LF24-400A [114.3] 80,500 [23.6] 92,000 [27.0] Output LPG/ Propane Btuh [kw] 82,000 [24.0] 92,000 [27.0] 1,000 1,000 [34.0] [34.0] 138,000 138,000 [40.4] [40.4] 156,000 156,000 [45.6] [45.6] 184,000 184,000 [53.9] [53.9] 201,250 205,000 [59.0] [60.1] 241,500 246,000 [70.8] [7] 276,000 281,200 [80.9] [82.4] 312,000 312,000 [91.4] [91.4] Steady state Efficiency LPG/ Natural Propane 80.5% 81.0% 80.5% 81.0% 80.5% 81.0% 80.0% 81.0% Flue Size Round 6 3 [152] 6 3 [152] Gas Piping Size [npt] 3/ 3/ 3/ 3/ 3/ NO. Dia. of Fans NO. of NO. of Output Blades s hp [W] Full Load Amps [total] *"S" denotes stainless steel heat exchanger. "A" denotes aluminized steel heat exchanger. All models are 115 volts, 60 hertz, 1 phase. 1 2- x 4 in. (54 x 102 mm) diameter adaptor is furnished with unit for flue connection. 2 2-1/4 x 2-3/4 in. (57 x 70 mm) rectangular to 5 in. (127 mm) round adaptor is furnished with unit for flue connection. 3 2-1/4 x 2-3/4 in. (57 x 70 mm) rectangular to 6 in. (152 mm) round adaptor is furnished with unit for flue connection. Note: Due to Allied Commercial's ongoing commitment to quality, all specifications, ratings and dimensions are subject to change. [4.2) Air Vol. CFM [L/s] 1900 [895] 1900 [895] 1900 [895] 2200 [1035] 2200 [1035] DIMensions H X W X L [INCHES] 32-3/ x 20-3/ x 39-3/ 32-3/ x 20-3/ x 39-3/ 32-3/ x 20-3/ x 39-3/ 32-3/ x 23-32-3/ x 23-32-3/ x 41-32-3/ x 41-32-3/ x 41-32-3/ x 41- x 41-32-3/ x 41- x 41- SHIP WT. [LBS.] 140 140 150 5 5 270 285 305 310 315

Visit us at www.allied-commercial.com or contact us at 1-800-448-5872. 2013 Allied Air Enterprises LLC., a Lennox International Inc. Company Litho U.S.A. ACLF-300 05/13 PC73454