Similar documents
(770) wwww.southgateprocess.com

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Product Catalog. Air and Space Heaters. Section C

CR1 Series Triton Corrosion Resistant Washdown Heaters

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

Industrial Air Heaters

ULTRA-SAFE Explosion-proof Duct Heaters

Thermal Devices, Inc. Mount Airy, Maryland USA

Immersion Heaters. Screw Plug Immersion Heater

ULTRA-SAFE Explosion-proof Duct Heaters

Tubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product

Custom Duct Heaters. Special Applications

TABLE OF CONTENTS page 2

Custom Duct Heaters. Special Applications

Description. Construction

Electric Coils. Blower Coils. Product Information

KUH. Horizontal Unit Heater. Applications. Description

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

Visit our web site at

Construction Electrical

Tubular Industrial Process

Standard Duct Heaters Open Coil

Commercial Duct Heaters. Our products do more in a wide range of applications. Expect More.

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Strip/Clamp-On Heaters

Bulletin A Brasch Manufacturing Co., Inc.

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Tubular Industrial Process

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

OVER-THE-SIDE HEATERS. immersion heaters

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

UNIFIED FACILITIES GUIDE SPECIFICATIONS

( )

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH

M1 SERIES DUCT HEATERS

FX5 Series Explosion-Proof Electric Air Heaters

Hotwatt, established in 1952, began with the manufacturing of one product, the open coil heating element. Since then Hotwatt has expanded our product

Explosion-Proof Forced Air Unit Heater - XGB

Neptronic Toll Free: TEL: (514) Fax:(514)

Circulation Heaters Selection Guidelines

Explosion-Proof Forced Air Unit Heater - XGB

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

CF1 ProVector Explosion-Proof Heaters

Powers Controls ET 134 Low Temperature Detection Thermostat

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

CX1 ProVector Explosion-Proof Heaters

FE1 Explosion-Proof Electric Air Heaters

STRAIGHT & FORMED TUBULAR HEATERS

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Lynergy Comfort Control SCR Electric Heater Application Guide

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

Tubular Industrial Process

BAND HEATERS component parts

Series HF custom designed flange and insert heaters.

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Electric Heat - Air Curtains

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Description. Applications

Electric Duct Heaters. IDHB & IDHC Series

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

temperature Controllers

SECTION (15767) - UNIT HEATERS

Type UB-2502A and UB-3002A Forced-Air Heater

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

SECTION AIR COILS

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

EXH Series Explosionproof Electric Air Heaters

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Electric Duct Heaters

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Screw Plug Immersion Heaters

SINGLE DUCT TERMINAL UNITS

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

SUBMITTAL SCHEDULE & DATA

RED DOT UNITS HEATER ONLY. Heaters PAGE 51

Helically wound resistance wire coil made

Vertical Upflow Horizontal Left Air Handlers

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

Installation & Maintenance Instructions

SCREW PLUG IMMERSION HEATERS

Circulation Heaters Selection Guidelines

Powers Controls Low Temperature Detection Thermostat

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Transcription:

(1-800-492-8826) www.wattco.com

OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies two types of duct heaters: air duct heaters and process heaters. Air duct heaters are primarily used in air flowing ventilation systems and comfort heating applications while process duct heaters are mainly used for industrial process heating applications (ovens that require re-circulated air or forced circulation). WATTCO designs and configures your electric duct heaters ccording to your specifications. Our team is dedicated to research and development of the latest technologies, while striving to meet every customer s needs by manufacturing first class duct heaters. Our 50-year expertise in developing and manufacturing electric duct heaters make WATTCO duct heaters, the most easily adaptable solutions for most nonpressurized air-heating systems. KEY FEATURES 16-gauge satin coat steel Exclusive modular construction with stock frame components used with 2 vertical and horizontal dimensional increments for faster delivery Single and three-phase tensions Stainless steel supports Field replaceable heating elements, if required ¼ (6 mm) inside diameter thermowell 3 ½ (90 mm) thick insulation General purpose terminal enclosure Primary linear cutout: 160ºF (71ºC) 277/600 VAC 25/10 AMP non-inductive Secondary linear cutout: Manual reset with back-up magnetic contactor on units of 300V, 30 kw and less 225ºF (107ºC) 277/600 VAC 25/10 AMP non-inductive Special sizes, wattages, and materials available upon request Built stainless steel frames available upon request American and Canadian Standards Associations (CSA, CSAus) certified SELECTING YOUR WATTCO AIR DUCT HEATER BENEFITS Versatile Corrosion and oxidation resistant Easy to maintain Easy to install Durable Compatible with local power supplies Built for safety Maximal dielectric strength and heat transfer Minimal heat loss Maintained wiring cooler Clean heat Easy service Minimal downtime APPLICATIONS Heat treating Forced air comfort heating Booster air heater Air drying operations Core drying Air pre-heating Air handling equipment Fan coils Terminal reheating Multizone reheating Heat pump auxiliary systems Return air heating Resistor load banks Annealing TYPE QFD TYPE QID APPLICATIONS CONSTRUCTION TYPE TUBULAR ELEMENTS HEATER TYPE Comfort heating Flanged duct heater Finned QFD Comfort heating Insert duct heater Finned QID Comfort heating Flanged duct heater Incoloy (non-finned) QFE Comfort heating Insert duct heater Finned QIE Please call us at 1-800-4WATTCO (1-800-492-8826) for further assistance. 2 www.wattco.com (1-800-492-8826)

SELECTING YOUR WATTCO AIR DUCT HEATER A broad range of custom built electric duct heaters with capacities up to 1000kW is available upon request. WATTCO heaters can be used for applications with the following voltages: 347 volts/1 phase 600 volts/1 phase 600 volts/3 phases 208/240 volts/1 phase 208 volts/3 phases WATTCO duct heaters have the international, American recognized, Canadian Standards Association (CSAus) label, which set the standards for the electric heating industry. Duct heater can include proper built-in safety devices to extend the service life of the heater. FIG. 2 - INCOLOY UNFINNED TUBULAR ELEMENT FIG. 3 - KILOWATTS WATTCO also manufactures heaters for industrial processes, original equipment manufacturers (OEM) or any other special applications. KILOWATTS Refer to Figure 3 to choose the appropriate kw for your application. KILOWATTS FIG. 1 - FINNED TUBULAR ELEMENT TEMPERATURE RISE - ºF FINNED TUBULAR ELEMENTS vs INCOLOY UNFINNED TUBULAR ELEMENTS The most common design FINNED TUBULAR ELEMENTS Include the highest wattage / cross sectional duct area Energy saver Made of a steel tube with a corrugated steel fin wrapped around it and brazed together Maximize the heat transfer surface of the element Provide lower operating temperature Designed for low maintenance INCOLOY UNFINNED TUBULAR ELEMENTS Available for approved special orders only Increase corrosion resistance High humidity environments Corrosive chemical contaminants in the air stream Protect from electrical shock Made of steel or stainless tube Can be installed close to a register or grille N/A Designed for low maintenance Please call us at 1-800-4WATTCO (1-800-492-8826) for further assistance. (1-800-492-8826) www.wattco.com 3

CONSTRUCTION The two available basic heater frame constructions (Figures 4 and 5) are: Insert type Flange type Notes: Frames will be constructed with adequate thickness galvanized steel in order to provide sturdiness of the heater. The mounting flanges for insertion provide an easy and safe fastening to the duct and do not require the main electrical control panel to be opened. Heating elements are made of open nickel chrome. High temperature resistant and first grade ceramics support coils horizontally. Coils are machine-crimped onto galvanized terminal and secured by a ceramic socket which is resistant to anti-rotating high temperature. All heaters are supplied with magnetic contactors and a primary automatic reset thermal cut-out to avoid overheating. Refer to the alternative auxiliary duct heater controls section on page 11.6 for a list of available controls. TYPICAL DIMENSIONS Insert type heaters: Undersized to allow duct installation with A and B dimensions, as shown in Table 1 on Page 5 FIG. 4 - INSERT TYPE TYPE QFD FIG. 5 - FLANGE TYPE TYPE QID DIM. in. mm C 6 1/2 163 D 7 178 E 2 51 4 www.wattco.com (1-800-492-8826)

QFD and QID Air Duct Heaters Install the heaters in a horizontal duct with the terminal housing at the side or bottom. Use tandem mounting (several heaters in series) when possible. Note: Units in Table 2 are only examples. For safety reasons, refer to this table as a guideline for custom design orders. Custom designed units will be built according to the requirements of your specific application. Note: QFE and QIE Incoloy tubular duct heaters are only available upon request COMMON FEATURES Primary linear cutout: 160ºF (71ºC) 277/600 VAC, 25/10 AMP non-inductive Secondary linear cutout - Manual reset complete with back-up magnetic contactor on units under 300V, 30 kw and less; 225ºF (107ºC) 277/600 VAC, 25/10 AMP non-inductive ALTERNATIVE AUXILIARY DUCT HEATER CONTROLS The following controls are supplied by WATTCO on the duct heater or are available as an EEMAC rated control panel for wall mount: Duct thermostats QFD (1 stage) QFD (2 stage) QFD (0-135 OHM) Controller Room thermostat Bulb holders Silent contactors SCR controllers Sail switch Fixed pressure differential switch Main disconnect Pneumatic electric switches On-off switch Magnetic contactors Step controllers Load fuses Stage fuses HRC fusing Control transformers Bottom terminal box Secondary manual reset thermal cut-out Fan interlock relay Protective screens Pilot lights TYPE QFD TYPE QID TABLE 2 Types QFD/QID Duct Heaters with Finned Elements KW STANDARD VOLTAGES 120V 208V 240V 480V 600V 1 1 3 1 3 DIMENSIONS IN. (MM) A B MINIMUM AIR FLOW CFM (M 3 /MIN) NO. OF ELEMS. CATALOG FLANGE TYPE / QFD NUMBERS INSERT TYPE / QID APPROX. WEIGHT LBS (KG) 1 a a 6 (152) 6 (152) 50 (1.4) 2 QFD0010 QID0010 15 (7) 2.5 a a a 6 (152) 6 (152) 150 (4.2) 3 QFD0025 QID0025 15 (7) 7.5 a a a a 14 (356) 8 (203) 390 (11.0) 4 QFD0075 QID0075 20 (9) 10 a a a a 14 (356) 12 (305) 500 (14.1) 6 QFD0100 QID0100 25 (11) 12.5 a a a a 16 (406) 12 (305) 625 (17.7) 6 QFD0125 QID0125 30 (14) 15 a a a a 18 (457) 12 (305) 750 (21.2) 6 QFD0150 QID0150 30 (14) 17.5 a a a a 18 (457) 14 (356) 875 (24.8) 6 QFD0175 QID0175 35 (16) 20 a a a a 18 (457) 16 (406) 1000 (28.3) 6 QFD0200 QID0200 35 (16) 25 a a a 20 (508) 18 (457) 1250 (35.4) 9 QFD0250 QID0250 50 (23) 30 a a a 24 (610) 18 (457) 1500 (42.4) 9 QFD0300 QID0300 55 (25) 35 a a a 24 (610) 22 (559) 1650 (46.7) 9 QFD0350 QID0350 60 (27) 40 a a a 26 (660) 24 (610) 2050 (58.0) 12 QFD0400 QID0400 70 (32) 45 a a a 28 (711) 24 (610) 2200 (62.2) 12 QFD0450 QID0450 75 (34) 50 a a a 28 (711) 26 (660) 2500 (70.7) 12 QFD0500 QID0500 80 (36) 60 a a a 30 (762) 30 (762) 3000 (84.9) 15 QFD0600 QID0600 95 (43) 80 a a a 36 (914) 32 (813) 4000 (113.1) 15 QFD0800 QID0800 105 (48) 100 a a a 42 (1067) 36 (914) 5250 (148.5) 18 QFD1000 QID1000 130 (59) 120 a a a 48 (1219) 36 (914) 6000 (170.0) 18 QFD1200 QID1200 150 (68) (1-800-492-8826) www.wattco.com 5

OVERVIEW WATTCO process duct heaters are installed in forced air ducts and used for industrial processes (forced air dryers, core drying, annealing) that require medium to high air temperature (at least 750 F/400 C). Process duct heaters come with the same standard and optional features as air duct heaters. Please call us at 1-800-4WATTCO (1-800-492-8826) for further assistance in selecting the best WATTCO process duct heater for your application. TABLE 3 Process Duct Heaters KW STANDARD VOLTAGES 208 240 480 600 1 3 1 3 A DIM. C DIM. TYPE AMT - INTERMEDIATE TEMPERATURE DESIGN - 27 W/in 2. (4.2 W/cm 2 ) MODEL W/cm W/in. D DIM. Y DIM. CAT. NO. NET WT. LBS (KG) 6 a a a a 155 (6.1) 135 (5.3) 110 (4.3) AMT-6X 15.4 (7) 12 a a a a 235 (9.3) 215 (8.5) 190 (7.5) AMT-12X 26.5 (12) 18 a a a a 310 (12.2) 290 (11.4) 50 (1.97) 265 (10.4) AMT-18X 39.7 (18) 24 a a a 385 (15.2) 365 (14.4) 90 (3.54) 340 (13.4) AMT-24X 48.5 (22) 30 a a a 460 (18.1) 440 (17.3) 110 (4.33) 415 (16.3) AMT-30X 57.3 (26) 36 a a a 540 (21.3) 520 (20.5) 130 (5.12) 495 (19.5) AMT-36X 63.9 (29) 42 a a a 615 (24.2) 595 (23.4) 150 (5.90) 570 (22.4) AMT-42X 72.8 (33) 48 a a a 690 (27.2) 670 (26.4) 170 (6.69) 645 (25.4) AMT-48X 79.4 (36) 54 a a a 765 (30.1) 745 (29.3) 185 (7.28) 720 (28.3) AMT-54X 86.0 (39) 60 a a a 840 (33.1) 820 (32.3) 205 (8.07) 800 (31.5) AMT-60X 92.6 (42) 72 a a a 990 (39.0) 970 (38.2) 160 (6.30) 950 (37.4) AMT-72X 105.8 (48) 84 a a a 1140 (44.9) 1120 (44.1) 185 (7.28) 1100 (43.3) AMT-84X 119.1 (54) TYPE AML - HIGH TEMPERATURE DESIGN (UP TO 950ºF OUTLET TEMP.) - 27 W/in 2. (4.2 W/cm 2 ) 12 a a a a 235 (9.3) 215 (8.5) 190 (7.5) AML-12X 28.7 (13) 18 a a a a 310 (12.2) 290 (11.4) 50 (1.97) 265 (10.4) AML-18X 41.9 (19) 24 a a a 385 (15.2) 365 (14.4) 90 (3.54) 340 (13.4) AML-24X 55.1 (25) 36 a a a 540 (21.3) 520 (20.5) 130 (5.12) 495 (19.5) AML-36X 68.3 (31) 48 a a a 690 (27.2) 670 (26.4) 170 (6.69) 645 (25.4) AML-48X 81.6 (37) 60 a a a 840 (33.1) 820 (32.3) 205 (8.07) 800 (31.5) AML-60X 94.8 (43) 72 a a a 990 (39.0) 970 (38.2) 160 (6.30) 950 (37.4) AML-72X 108.0 (49) 84 a a a 1140 (44.9) 1120 (44.1) 185 (7.28) 1100 (43.3) AML-84X 121.3 (55) TYPE AML - HIGH TEMPERATURE DESIGN (UP TO 1100ºF OUTLET TEMP.) - 20 W/in. 2 (3.1 W/cm 2 ) 12 a a a a 235 (9.3) 215 (8.5) 190 (7.5) AML-12Y 30.9 (14) 18 a a a a 310 (12.2) 290 (11.4) 50 (1.97) 265 (10.4) AML-18Y 44.1 (20) 24 a a a 385 (15.2) 365 (14.4) 90 (3.54) 340 (13.4) AML-24Y 57.3 (26) 36 a a a 540 (21.3) 520 (20.5) 130 (5.12) 495 (19.5) AML-36Y 70.5 (32) 48 a a a 690 (27.2) 670 (26.4) 170 (6.69) 645 (25.4) AML-48Y 83.8 (38) 60 a a a 840 (33.1) 820 (32.3) 205 (8.07) 800 (31.5) AML-60Y 97.0 (44) 72 a a a 990 (39.0) 970 (38.2) 160 (6.30) 950 (37.4) AML-72Y 110.2 (50) 84 a a a 1140 (44.9) 1120 (44.1) 185 (7.28) 1100 (43.3) AML-84Y 123.5 (56) WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue number, tension, wattage, shop drawings, and extra features. B DIM. E DIM. F DIM. AMT 4.2 27 410 (16.1) 150 (5.9) 35 (1.4) AML 4.2 27 410 (16.1) 250 (9.8) 00 AML 3.1 20 530 (20.9) 250 (9.8) 51 6 www.wattco.com (1-800-492-8826)