Annubar Flowmeter Series

Similar documents
Rosemount 752 Fieldbus Remote Indicator

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 3095MFC Compact Orifice Mass Flowmeter

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2090P Pulp and Paper Pressure Transmitter

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 3051SFC Compact Orifice Flowmeter

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Rosemount 3051SFP Proplate Flowmeter

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 3051 Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 1595 Conditioning Orifice Plate

Rosemount 702 Wireless Discrete Transmitter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount Compact Orifice Flowmeter Series

Rosemount 3144P Rosemount 3144P Temperature Transmitter

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Rosemount 8800D Series Vortex Flowmeter

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount Integral Orifice Flowmeter Series

Rosemount 3490 Series

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 3144P Temperature Transmitter with HART Protocol

Rosemount 2090F Hygienic Pressure Transmitter

Sanitary Pressure Transmitter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series MultiVariable Flowmeter

Rosemount 3144P Rosemount 3144P Temperature Transmitter

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Rosemount 848T FOUNDATION Fieldbus High Density Temperature Transmitter

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Rosemount 3051S MultiVariable Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 752 Remote Indicator

Rosemount 3051CFC Compact Flowmeter

Rosemount 248 Temperature Transmitter

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Tank Gauging System Special Safety Instruction

Rosemount 2051CF DP Flowmeters

4) Intrinsic Safety Certification

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Absolute and Gage Pressure Transmitter

Rosemount 3051CFP Integral Orifice Flowmeter

Sensor Wiring Instructions and Approval Drawings

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 3144P Temperature Transmitters with FOUNDATION Fieldbus Protocol. Quick Start Guide , Rev DA June 2016

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Rosemount 644H Temperature Transmitters

Rosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter

Rosemount 644H Temperature Transmitters

Rosemount 3051 Pressure Transmitter and Rosemount 3051CF Series Flowmeter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

OPTIBAR DP 7060 Supplementary Instructions

Certificate of Compliance

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Rosemount 2051G Pressure Transmitter

Rosemount 3051S Series of Instrumentation

Rosemount 644 Temperature Transmitter

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Rosemount 3051S Series of Instrumentation

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Inductive slot sensor

Rosemount 3051S MultiVariable Extension Supplement

User s Manual YTA610 and YTA710 NEPSI Certification

Rosemount 8732E Magnetic Flowmeter System with Profibus PA digital fieldbus (Transmitter and Sensor)

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Certificate of Compliance

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Technical Data. Dimensions

Transcription:

Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA Product Certifications.......... page B-6 Installation Drawings............................. page B-10 HAZARDOUS LOCATIONS INSTALLATIONS The flowmeter is designed with explosion-proof housings and circuitry suitable for intrinsically safe and non-incendive operation. Each flowmeter is clearly marked with a tag indicating the approvals. To maintain certified ratings for installed transmitters, install in accordance with all applicable installation codes and approval drawings. Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications. Both transmitter covers must be fully engaged to meet explosion proof requirements. ROSEMOUNT 3051SFA PRODUCT CERTIFICATIONS Approved Manufacturing Locations European Directive Information Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co., LTD Beijing, China The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option) Pressure Transmitters QS Certificate of Assessment - EC No. PED-H-20, Module H Conformity Assessment All other Model 3051S Pressure Transmitters Sound Engineering Practice Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold Sound Engineering Practice Primary Elements, Flowmeter See appropriate Primary Element QIG www.rosemount.com

Annubar Flowmeter Series Reference Manual Electro Magnetic Compatibility (EMC) (89/336/EEC) All Models: EN 50081-1: 1992; EN 50082-2:1995; EN 61326-1:1997 Industrial Ordinary Location Certification for FM Hazardous Locations Certifications As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). North American Certifications FM Approvals E5 Explosion-proof for Class I, Division 1, Groups B, C, and D; dust-ignition proof for Class II and Class III, Division 1, Groups E, F, and G; hazardous locations; enclosure Type 4X, conduit seal not required when installed according to Rosemount drawing 03151-1003. I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1; Class I, Zone 0 AEx ia IIC when connected in accordance with Rosemount drawing 03151-1006; Non-incendive for Class I, Division 2, Groups A, B, C, and D Enclosure Type 4X For entity parameters see control drawing 03151-1006. Canadian Standards Association (CSA) E6 Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust-Ignition-Proof for Class II and Class III, Division 1, Groups E, F, and G; suitable for Class I, Division 2, Groups A, B, C, and D, when installed per Rosemount drawing 03151-1013, CSA Enclosure Type 4X; conduit seal not required. I6 Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings 03151-1016; For entity parameters see control drawing 03151-1016. European Certifications I1 ATEX Intrinsic Safety Certificate No.: BAS01ATEX1303X EEx ia IIC T5 (-60 C T a 40 C) T4 (-60 C T a 70 C) T4 (-60 C T a 40 C) (FISCO) 1180 II 1G B-2

Reference Manual Annubar Flowmeter Series Loop / Power U i = 30 V U i = 17.5 V I i = 300 ma I i = 380 ma P i = 1.0 W P i = 1.3 W P i = 5.32 W C i = 30 nf C i = 11.4 nf C i = 0 L i = 0 L i = 60 µh Groups HART / FOUNDATION Fieldbus/ Remote Display / SIS FISCO HART / FOUNDATION Fieldbus/ Remote Display / SIS FISCO HART / Remote Display / SIS FOUNDATION Fieldbus FISCO SuperModule HART / SIS FOUNDATION Fieldbus / Remote Display / FISCO HART / FOUNDATION Fieldbus/ SIS / FISCO Remote Display Special conditions for safe use (x) 1. The apparatus, excluding the Types 3051 S-T and 3051 S-C (In-line and Coplanar SuperModules respectively), is not capable of withstanding the 500 V test as defined in Clause 6.4.12 of EN 50020. This must be considered during installation. 2. The terminal pins of the Types 3051 S-T and 3051 S-C must be protected to IP20 minimum. N1 ATEX Type n Certificate No.: BAS01ATEX3304X II 3 G EEx nl IIC T5 (T a = -40 C TO 70 C) Ui = 45 Vdc max IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500 V insulation test required by Clause 9.1 of EN 50021: 1999. This must be taken into account when installing the apparatus. ND ATEX Dust Certificate No.: BAS01ATEX1374X II 1 D T105 C (-20 C T amb 85 C) V max = 42.4 volts max A = 24 ma IP66 1180 B-3

Annubar Flowmeter Series Reference Manual Special conditions for safe use (x) E1 1. The user must ensure that the maximum rated voltage and current (42.4 volts, 22 milliampere, DC) are not exceeded. All connections to other apparatus or associated apparatus shall have control over this voltage and current equivalent to a category ib circuit according to EN 50020. 2. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP66. 3. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact test. 5. The 3051S must be securely screwed in place to maintain the ingress protection of the enclosure. ATEX Flameproof Certificate No.: KEMA00ATEX2143X EEx d IIC T6 (-50 C T amb 65 C) EEx d IIC T5 (-50 C T amb 80 C) V max = 42.4 V 1180 II 1/2 G Special conditions for safe use (x) This device contains a thin wall diaphragm. Installation, maintenance, and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime. The Model 3051S pressure transmitter must include a Series 300S housing integrally mounted to a Series Model 3051S Sensor module as per Rosemount drawing 03151-1023. Australian Certifications E7 SAA Explosion-proof and DIP Certification No.: AUS Ex 3798X Ex d IIC T6 (T a = 60 C) IP66 DIP A21 TA T6 (T a = 60 C) IP66 Special conditions for safe use (x) 1. It is a condition of manufacture that each transmitter module shall be pressure tested in accordance with clause 4.3 of AS 2380.2 at minimum pressure of 1450 kpa. As the model 300S housing passed tests at 4 times the reference pressures (400 kpa for single and 3800 kpa for dual compartment housing) and are not of welded construction, they may be exempted from the routing pressure test of clause 4.3 of AS 2380.2. 2. It is a condition of manufacture that each transmitter module and housing combination shall be subjected to a routine high voltage test in accordance with clause 6.2 of AS 2380.1, with the following variation. The test voltage applied to each single or dual compartment housing shall not be less than 500 V, 47 to 62 Hz, for a period of not less than one minute, with a breakdown current of less than 5 ma. B-4

Reference Manual Annubar Flowmeter Series 3. It is a condition of safe use that each housing shall be connected to external circuits via suitable conduit or Standards Australia certified cable glands. Where only one entry is used for connection to external circuits, the unused entry shall be closed by means of the blanking plug supplied by the equipment manufacturer or by a suitable Standards Australia certified blanking plug. 4. It is a condition of safe use that a dielectric strength test shall be applied whenever the terminal block is changed or replaced in either the dual compartment or single compartment housings. The breakdown current shall be less than 5 ma, when 500 V, 47 to 62 Hz, is applied for one minute. Note: if tested with an optional T1 transient protector terminal block fitted, the protection will operate and hence there will be no current indicated. 5. It is a condition of safe use that each transmitter module shall be used with a Model 300S housing, in order to comply with flameproof requirements. 6. It is a condition of safe use that each model 300S housing fitted with a transmitter module shall be marked with the same certification marking code information. Should the housing be replaced after initial supply to another model 300S housing, the replacement housing shall have the same certification marking code information as the housing it replaces. IECEx Certifications I7 IECEx Intrinsic Safety Certificate No.: IECExBAS04.0017X Ex ia IIC T5 (T a = -60 C to 40 C) -Hart/SIS/Remote Meter Ex ia IIC T4 (T a = -60 C to 70 C) -Hart/SIS/Remote Meter Ex ia IIC T4 (T a = -60 C to 70 C) -FOUNDATION Fieldbus Ex ia IIC T4 (T a = -60 C to 40 C) -FISCO IP66 Loop / Power Groups U i = 30 V HART / FOUNDATION Fieldbus/ Remote Display / SIS U i = 17.5 V FISCO I i = 300 ma HART / FOUNDATION Fieldbus/ Remote Display / SIS I i = 380 ma FISCO P i = 1.0 W HART / Remote Display / SIS P i = 1.3 W FOUNDATION Fieldbus P i = 5.32 W FISCO C i = 30 nf SuperModule C i = 11.4 nf HART / SIS C i = 0 FOUNDATION Fieldbus / Remote Display / FISCO L i = 0 HART / FOUNDATION Fieldbus/ SIS / FISCO L i = 60 µh Remote Display Special conditions for safe use (x) 1. The Models 3051S HART 4-20mA, 3051S Fieldbus, 3051S Profibus and 3051S FISCO are not capable of withstanding the 500 V test as defined in clause 6.4.12 of IEC 60079-11. This must be taken into account during installation. 2. The terminal pins of the Types 3051S-T and 3051S-C must be protected to IP20 minimum. B-5

Annubar Flowmeter Series Reference Manual N7 IECEx Type n Certificate No.: IECExBAS04.0018X Ex nc IIC T5 (Ta = -40 C to 70 C) Ui = 45 Vdc MAX IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500 V insulation test required by Clause 8 of IEC 79-15: 1987. Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. K1 Combination of E1, I1, N1, and ND K5 Combination of E5 and I5 K6 Combination of E6 and I6 K7 Combination of E7, I7, and N7 KA Combination of E1, I1, E6, and I6 KB Combination of E5, I5, I6, and E6 KC Combination of E5, E1, I5, and I1 KD Combination of E5, I5, E6, I6, E1, and I1 ROSEMOUNT 3095MFA PRODUCT CERTIFICATIONS The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained by contacting our local sales office. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) 3095M_2/3,4/D Flow Transmitters QS Certificate of Assessment - EC No. PED-H-20 Module H Conformity Assessment All other 3095_ Transmitters/Level Controller Sound Engineering Practice Transmitter Attachments: Process Flange - Manifold Sound Engineering Practice 3095MFP Integral Orifice Mass Flowmeter Refer to declaration of conformity for 1195 Integral Orifice Series classification. Electro Magnetic Compatibility (EMC) (89/336/EEC) 3095MV Flow Transmitters EN 50081-1: 1992; EN 50082-2:1995; EN 61326-1:1997 Industrial B-6

Reference Manual Annubar Flowmeter Series Ordinary Location Certification for Factory Mutual As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition Proof for Class II/Class III, Division 1, Groups E, F, and G. Enclosure type NEMA 4X. Factory Sealed. Provides nonincendive RTD connections for Class I, Division 2, Groups A, B, C, and D. I5 Intrinsically Safe for use in Class I, II, and III, Division 1, Groups A, B, C, D, E, F, and G hazardous outdoor locations. Non-incendive for Class I, Division 2, Groups A, B, C, and D. Temperature Code T4. Factory Sealed. For input parameters and installation see control drawing 03095-1020. Canadian Standards Association (CSA) E6 I6 Explosion Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition Proof for Class II/Class III, Division 1, Groups E, F, and G. CSA enclosure Type 4X suitable for indoor and outdoor hazardous locations. Provides nonincendive RTD connection for Class I, Division 2, Groups A, B, C, and D. Factory Sealed. Install in accordance with Rosemount Drawing 03095-1024. Approved for Class I, Division 2, Groups A, B, C, and D. Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. when installed in accordance with Rosemount drawing 03095-1021. Temperature Code T3C. For input parameters and installation see control drawing 03095-1021. European Certifications I1 ATEX Intrinsic Safety Certificate Number: BAS98ATEX1359X II 1 G EEx ia IIC T5 (T amb = 45 C to 40 C) EEx ia IIC T4 (T amb = 45 C to 70 C) 1180 B-7

Annubar Flowmeter Series Reference Manual Table B-1. Connection Parameters (Power/Signal Terminals) U i = 30 V I i = 200 ma P i = 1.0 W C i = 0.012 µf L i = 0 Table B-2. Temperature Sensor Connection Parameters U o = 30 V I o = 19 ma P o = 140 mw C i = 0.002 µf L i = 0 Table B-3. Temp Sensor Terminals Connection Parameters C o = 0.066 F Gas Group IIC C o = 0.560 F Gas Group IIB C o = 1.82 F Gas Group IIA L o = 96 mh Gas Group IIC L o = 365 mh Gas Group IIB L o = 696 mh Gas Group IIA L o /R o = 247 H/ohm Gas Group IIC L o /R o = 633 H/ohm Gas Group IIB L o /R o = 633 H/ohm Gas Group IIA Special Conditions for Safe Use N1 The 3095, when fitted with the transient terminal block (order code B), are not capable of withstanding the 500 V insulation test required by EN50 020, Clause 6.4.12 (1994). This condition must be accounted for during installation. ATEX Type N Certificate Number: BAS98ATEX3360X II 3 G EEx nl IIC T5 (T amb = 45 C to 40 C) EEx nl IIC T4 (T amb = 45 C to 70 C) U i = 55 V E1 The apparatus is designed for connection to a remote temperature sensor such as a resistance temperature detection (RTD) Special Conditions for Safe Use The 3095, when fitted with the transient terminal block (order code B), are not capable of withstanding the 500 V insulation test required by EN50 021, Clause 9.1 (1995). This condition must be accounted for during installation. ATEX Flameproof Certificate Number: KEMA02ATEX2320X II 1/2 G EEx d IIC T5 (-50 C T amb 80 C) T6 (-50 C T amb 65 C) 1180 B-8

Reference Manual Annubar Flowmeter Series Special Conditions for Safe Use (x): The device contains a thin wall diaphragm. Installation, maintenance, and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime. ND ATEX Dust Certificate Number: KEMA02ATEX2321 II 1 D V = 55 Vdc MAX I = 23 ma MAX IP66 1180 Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. K5 E5 and I5 combination K6 E6 and I6 combination K1 I1, N1, E1, and ND combination B-9

Annubar Flowmeter Series Reference Manual INSTALLATION DRAWINGS Rosemount 3051SFA ProBar Flowmeter Rosemount 3095MFA Mass ProBar Flowmeter Rosemount Drawing 03031-1019, 12 Sheets: Factory Mutual (FM) Installation Drawing. Rosemount Drawing 00268-0031, 7 Sheet: Factory Mutual (FM) Installation Drawing. Rosemount Drawing 03031-1024, 1 Sheet: Canadian Standards Association (CSA) Installation Drawing. Rosemount Drawing 03095-1025, 1 Sheet: Factory Mutual (FM) Installation Drawing. Rosemount Drawing 03095-1020, 1 Sheet: Factory Mutual (FM) Installation Drawing. Rosemount Drawing 03095-1021, 1 Sheet: Canadian Standards Association (CSA) Installation Drawing. IMPORTANT Once a device labeled with multiple approval types is installed, it should not be reinstalled using any of the other labeled approval types. To ensure this, the approval label should be permanently marked to distinguish the used from the unused approval type(s). B-10

Reference Manual Annubar Flowmeter Series Figure B-1. FM Installation Drawing 03031-1019, Rev. AC Page 1 of 12 03031-1019A01A B-11

Annubar Flowmeter Series Reference Manual Page 2 of 12 03031-1019A02A B-12

Reference Manual Annubar Flowmeter Series Page 3 of 12 03031-1019A03A B-13

Annubar Flowmeter Series Reference Manual Page 4 of 12 03031-1019A04A B-14

Reference Manual Annubar Flowmeter Series Page 5 of 12 03031-1019A05A B-15

Annubar Flowmeter Series Reference Manual Page 6 of 12 03031-1019A06A B-16

Reference Manual Annubar Flowmeter Series Page 7 of 12 03031-1019A07A B-17

Annubar Flowmeter Series Reference Manual Page 8 of 12 03031-1019A08A B-18

Reference Manual Annubar Flowmeter Series Page 9 of 12 03031-1019A09A B-19

Annubar Flowmeter Series Reference Manual Page 10 of 12 03031-1019A10A B-20

Reference Manual Annubar Flowmeter Series Page 11 of 12 03031-1019A11A B-21

Annubar Flowmeter Series Reference Manual Page 12 of 12 03031-1019A12A B-22

Reference Manual Annubar Flowmeter Series Figure B-2. FM Installation Drawing 00268-0031, Rev. M Page 1 of 7 0031A01A B-23

Annubar Flowmeter Series Reference Manual Page 2 of 7 0031A02A B-24

Reference Manual Annubar Flowmeter Series Page 3 of 7 0031A03A B-25

Annubar Flowmeter Series Reference Manual Page 4 of 7 0031A04A B-26

Reference Manual Annubar Flowmeter Series Page 5 of 7 0031A05A B-27

Annubar Flowmeter Series Reference Manual Page 6 of 7 B-28

Reference Manual Annubar Flowmeter Series Page 7 of 7 0031A07A B-29

Annubar Flowmeter Series Reference Manual Figure B-3. CSA Installation Drawing 03031-1024, Rev. AD Page 1 of 9 03031-1024A01A B-30

Reference Manual Annubar Flowmeter Series Page 2 of 9 03031-1024A02A B-31

Annubar Flowmeter Series Reference Manual Page 3 of 9 03031-1024A03A B-32

Reference Manual Annubar Flowmeter Series Page 4 of 9 03031-1024A04A B-33

Annubar Flowmeter Series Reference Manual Page 5 of 9 03031-1024A05A B-34

Reference Manual Annubar Flowmeter Series Page 6 of 9 03031-1024A06A B-35

Annubar Flowmeter Series Reference Manual Page 7 of 9 03031-1024A07A B-36

Reference Manual Annubar Flowmeter Series Page 8 of 9 03031-1024A08A B-37

Annubar Flowmeter Series Reference Manual Page 9 of 9 03031-1024A09A B-38

Reference Manual Annubar Flowmeter Series Figure B-4. FM Installation Drawing 03095-1025, Rev. AA Page 1 of 3 3095-1025A01A B-39

Annubar Flowmeter Series Reference Manual Page 2 of 3 3095-1025A02A B-40

Reference Manual Annubar Flowmeter Series Page 3 of 3 3095-1025A03A B-41

Annubar Flowmeter Series Reference Manual Figure B-5. FM Installation Drawing 03095-1020, Rev. AB Page 1 of 8 B-42

Reference Manual Annubar Flowmeter Series Page 2 of 8 B-43

Annubar Flowmeter Series Reference Manual Page 3 of 8 B-44

Reference Manual Annubar Flowmeter Series Page 4 of 8 B-45

Annubar Flowmeter Series Reference Manual Page 5 of 8 B-46

Reference Manual Annubar Flowmeter Series Page 6 of 8 B-47

Annubar Flowmeter Series Reference Manual Page 7 of 8 B-48

Reference Manual Annubar Flowmeter Series Page 8 of 8 B-49

Annubar Flowmeter Series Reference Manual Figure B-6. CSA Installation Drawing 03095-1021, Rev. AB Page 1 of 4 B-50

Reference Manual Annubar Flowmeter Series Page 2 of 4 B-51

Annubar Flowmeter Series Reference Manual Page 3 of 4 B-52

Reference Manual Annubar Flowmeter Series Page 4 of 4 B-53

Annubar Flowmeter Series Reference Manual B-54

Annubar Flowmeter Series Reference Manual Rosemount, the Rosemount logotype, Annubar, and ProBar are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communication Foundation. FOUNDATION is a trademark of the Fieldbus Foundation. Loctite and PST are registered trademarks of the Loctite Corporation. All other marks are the property of their respective owners. 2012 Rosemount, Inc. All rights reserved. Emerson Process Management Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 906 8889 Emerson Process Management GmbH & Co. Argelsrieder Feld 3 82234 Wessling Germany Tel 49 (8153) 9390 Fax 49 (8153) 939172 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com Beijing Rosemount Far East Instrument Co., Limited No. 6 North Street, Hepingli, Dong Cheng District Beijing 100013, China T (86) (10) 6428 2233 F (86) (10) 6422 8586 00809-0100-4809 Rev CB, 3/12