Air-channel testing landfill geomembrane seams

Similar documents
PVC GEOMEMBRANE FABRICATION AND INSTALLATION SPECIFICATION

Nondestructive Testing of Geomembranes

PVC aquaculture liners stand the test of time

Long-Term Durability of a 20 mil PVC Geomembrane

Guidelines for Installation of: Factory Fabricated Compounded 0.25 to 1.52 mm (10 to 60 mil) Thickness Unsupported Geomembranes

Liner Construction & Testing Guidance Overview

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

INTERNATIONAL ASSOCIATION OF GEOSYNTHETICS INSTALLERS (IAGI) AND FABRICATED GEOMEMBRANE INSTITUTE (FGI)

FIGURE 1 Crews finalizing 60-mil (1.5-mil), five-ply CSPE geomembrane liner with cap strips over field seams at the Palos Verdes Reservoir

Thirty-Year Durability of a 20-Mil PVC Geomembrane. E. J. NEWMAN and T. D. STARK*

GEOMEMBRANE FIELD INSTALLATION

GEOMEMBRANE AND DRAINAGE INSTALLATION SPECIFICATION

SPECIAL SPECIFICATION 3687 Impermeable Liner

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Horsehead Holding Corporation Relies on XR-5

Leak Location Geosynthetic Materials in Base Liner Systems. NY Federation SWANA. May, 2014

Acronyms. TRI TRI Environmental, Inc. Table of Contents. iii

SHEAR STRENGTH CHARACTERISTICS OF PVC GEOMEMBRANE-GEOSYNTHETIC INTERFACES

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

AQUAMASTER INSTALLATION GUIDE

REHABILITATION OF SAIDA DUMPSITE

I N D U S T R I A L Y A R D S

Geomembranes and Geosynthetic Clay Liners (GCLs)

DESIGNING AND SPECIFYING LANDFILL COVERS

IMPACTS AND LIMITATIONS OF QUALITY ASSURANCE ON GEOMEMBRANE INTEGRITY. Key Words: Construction Quality Assurance, Leak Detection, Geomembrane

APPENDIX A POND LINING TECHNICAL SPECIFICATIONS

Aquaculture Lining Systems

SOUTH AFRICAN NATIONAL STANDARD

Technical Note by T.D. Stark, T.R. Boerman, and C.J. Connor

D.P.E. Enviroliner. geotextile protection layer. covering new ground 2016

GEOWEB slope & shoreline protection OVERVIEW

SPECIFICATIONS AND TECHNICAL REQUIREMENTS FOR THE MANUFACTURING AND INSTALLATION OF POLYETHYLENE GEOMEMBRANES

SPECIFICATIONS AND TECHNICAL REQUIREMENTS FOR THE MANUFACTURING AND INSTALLATION OF POLYETHYLENE GEOMEMBRANES

GEOMEMBRANE INSTALLATION GUIDELINES AND SPECIFICATIONS FOR LLDPE 20, 30, AND 40 MIL UNREINFORCED & GEO-SKRIM SERIES REINFORCED LINERS.

Soil/Geosynthetic Interface Strengths from Torsional Ring Shear Tests

GRI White Paper #3. - on - Providing Flexibility in Destructive Seam Sampling/Testing. Robert M. Koerner and George R. Koerner

Equipment pressure applied to geomembrane in composite liner system

Consulting Engineers and Scientists. Closure Plan. Submitted by: GEI Consultants, Inc Voyager Drive Green Bay, Wisconsin

We Don t Have No Stinkin Dirt! Coal Ash Pond Closures (Traditional and an Alternative Method)

GSI White Paper #28. Cold Temperature and Free-Thaw Cycling Behavior of Geomembranes and Their Seams

CAPPING OF A GOLD MINE IN ROSIA MONTANA, ROMANIA

GRI White Paper #8. - on - Construction Quality Assurance-Inspectors Certification Program (CQA-ICP)

Introduction To Geosynthetics In Transportation

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

LARGE-SCALE SHEAR TESTS ON INTERFACE SHEAR PERFORMANCE OF LANDFILL LINER SYSTEMS

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No.

Evaluating Tubular Drainage Geocomposites for use in Lined Landfill Leachate Collection Systems

AASHTO M Subsurface Drainage

HEAP LEACH PAD DESIGN AND CONSTRUCTION PRACTICES IN THE 21 ST CENTURY

CalTrans tackles The Merge

INSTALLATION QUALITY-ASSURANCE GUIDE FOR SOLMAX-GSE S CONDUCTIVE LINER

October 7, 2016 Meeting Landfill Liner Regulations with Conductive Backed Geomembranes by Doyin Adesokan B.Eng Msc. Technical Manager - Solmax

Chesapeake Energy Center. Submitted To: Chesapeake Energy Center 2701 Vepco Street Chesapeake, VA 23323

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion

Selecting the Right Closure Cap Option for Your Surface Impoundment or CCR Landfill

Firestone Lining Systems. Dependable Performance in Demanding Environments

geotextiles bidim Nonwoven polyester geotextile Made in Australia Designed for performance RECYCLED Quality ISO 9001

geotextiles bidim Nonwoven polyester geotextile Made in Australia Designed for performance RECYCLED

Alternative Cover Systems

Geosynthetics for Erosion Control and Reinforcement

The use of geosynthetics in the installation of ballast layers

TRANSMISSIVITY BEHAVIOR OF SHREDDED SCRAP TIRE DRAINAGE LAYER IN LANDFILL COVER SYSTEM *

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

YEAR 20 - SEPTEMBER SPECIAL EDITION INDEPENDENT JOURNAL FOR THE GEOART SECTOR

Costs and Benefits of Geomembrane Liner Installation CQA. G.T. Darilek Leak Location Services, Inc., USA D.L. Laine ABSTRACT

Section Specification for Geotextile Used in Permanent Erosion Control Application

GEOTEXTILE DEFORMATION ANALYSIS OF GEOSYNTHETIC CLAY LINERS WITH FEM

NOTICE OF INTENT. Submitted To: Bremo Power Station 1038 Bremo Bluff Road Bremo Bluff, VA 23022

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

GEOMEMBRANE WELDING PROCEDURES AND IMPERVIOUSNESS ASSESSMENT

THREE DIMENSIONAL SLOPE STABILITY

FINAL COVER VENEER STABILITY ANALYSES FOR SCA DESIGN

Lessons Learned From the Failure of a GCL/Geomembrane Barrier on a Side Slope Landfill Cover

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Exposed Geomembrane Cover Systems for Coal Ash Facilities

HIGH PERFORMANCE COAL COMBUSTION RESIDUAL (CCR) SOLUTIONS

A Drainage Geocomposite for Coal Combustion Residual Landfills and Surface Impoundments

GRI White Paper #12. The Development of a Benefit/Cost Ratio Matrix for Optimal Selection of a Geosynthetic Material

SWANA/A&WMA s. Third Annual Landfill Operator s Training Geosynthetics in Landfills. February 13, 2013

ENVIRONMENTAL ENGINEERING LAND SURVEYING

Sustainable geomembrane recycling and downcycling

Geomembranes that work

Geomembranes that work

Exposed geomembrane covers: Part 1 - geomembrane stresses

and Water Features and Water Features

Improvement of Granular Subgrade Soil by Using Geotextile and Jute Fiber

An Introduction to Soil Stabilization for Pavements

Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills

Pullout of Geosynthetic Reinforcement with In-plane Drainage Capability. J.G. Zornberg 1 and Y. Kang 2

Geosynthetic Institute GSI GRI GT13(b) ISO Version

MATERIAL SPECIFICATION FOR GEOTEXTILES

Super Gripnet INTEGRATED DRAINAGE SYSTEM (IDS) GEOMEMBRANE

California is home to one of the most active

Performance of Geosynthetics in the Filtration of High Water Content Waste Material

Appendix M. Leachate Cover Specifications

PERFORMANCE OF GEOSYNTHETICS IN THE FILTRATION OF HIGH WATER CONTENT WASTE MATERIAL

EROSION & SEDIMENT CONTROL

GEOMEMBRANE LINERS FOR RESOURCE AND ENVIRONMENTAL PROTECTION: ENSURING LONG TERM PERFORMANCE

!!!!!!!!!!!!!!!! INSTALLATION!GUIDELINES!MANUAL! January!2018,!Revision!3.0! Advanced!Revetment!Technology!

APPENDIX E COMPACTION CHARACTERISTICS AND EQUIPMENT

Transcription:

Air-channel testing landfill geomembrane seams Results from a recent workshop help minimize destructive testing By Timothy D. Stark, John Heap, Stuart Lange, Dave McLaury and Stanford Slifer Thermal welding of polyvinyl chloride (PVC) geomembranes is an efficient and cost-effective method of field seaming. PVC geomembranes possess excellent thermal welding characteristics, such as a wide thermal seaming range and a lack of residual stresses or stress cracking. Also, as if with materials such as high-density polyethylene geomembrane, there is no required surface preparation (e.g., grinding). Fully automated welding systems can thermally weld PVC geomembranes as thin as 0.5 mm (20 mil). These welding systems allow the operator to adjust welding speed, nip-roller pressure, and welding temperature to create the best quality single- or dual-track thermal seams. This facilitates field seaming, though PVC geomembranes already call for as many as 80% fewer field seams than for polyethylene geomembranes. PVC affords the installation contractor the luxury of using three proven seaming methods: chemical fusion, hot wedge or hot air welding. The hot wedge and hot air welding can be performed using a single- or dual-track wedge. Each seaming method has proven itself viable in the field. This versatility of PVC within all of the industries that it has serviced over the past four decades makes PVC geomembrane attractive to the specifying community. For applications such as landfill liner and cover systems where the quality assurance (QA)/quality control (QC) requirements are stringent, dual-track wedge welding may be the engineering community s preferred method because the seam can be air-channel-tested. On 11 October 2004, a number of PVC Geomembrane Institute (PGI) members assembled at the Colorado Lining International facility near Denver to develop a consensus on the procedure for efficient field dual-track welding and air-channel testing of PVC geomembrane seams for landfill liner and cover systems. The participants in the PGI workshop included PVC geomembrane manufacturers, fabricators, installers, equipment suppliers and landfill designers. The recommended procedure presented herein is most applicable to the extensive QA/QC required by the landfill industry. It is anticipated that this procedure will facilitate third party QA personnel in verifying and documenting the integrity of field PVC geomembrane seams for landfill liner and cover systems. It is not anticipated that the air-channel testing procedure described herein will be required for other PVC geomembrane applications, such as wastewater, golf, decorative or recreational ponds. However, the procedure could be used for these other applications if the QA/QC procedure requires the testing, or if the fabricator/installer desires to utilize the technology. Photo 1. Wedge welding and air-channel testing area at the PGI workshop. Figure 1 shows the welding and air-channel testing being performed under field conditions to ensure the practicality of the welding and testing procedure presented below. The main objective of the PGI welding workshop was to develop a consensus for implementing the relationship 1 For peel strength Required air channel pressure lb/in = 111.4 1.504 (temp) in 0.006 (temp lb/in) Specified peel strength of 15.0 lb/in Sheet temperature at air channel test Figure 1. Relationship between the air-channel pressure required to verify a specified field peel strength of 2.6 N/mm and 15.0 lb./in. at various sheet temperatures, from Stark et al. (2004).

Photo 2. Inflated field seam in 0.75 mm (30 mil) PVC geomembrane. between the air-channel pressure 2.6 N/mm (15 psi) required to verify the PGI-specified seam peel strength (PGI 2004) presented in Stark et al. (2004) and shown in Figure 1. The main advantage of the relationship in Figure 1 is that seam peel strength can be verified from field air-channel nondestructive testing instead of through destructive tests. This leads to a substantial reduction in the destructive sampling of installed PVC geomembrane, as discussed below for the Crown Vantage Landfill in Michigan. In addition, regulatory agencies (e.g., New York Department of Environmental Quality) are proposing to eliminate destructive sampling and testing for PVC geomembranes if the procedure presented in this article is utilized. Some states, such as Michigan and Minnesota, are considering the same arrangement. This change in regulation is possible because of the relationship Photo 3. Air-channel testing of T seam in 30 mil sheet. between thermally welded seam burst strength and the seam peel strength (ASTM D6392) for a given sheet temperature (Figure 1). An important advantage of the peel strength/burst pressure relationship in Figure 1 is the ability to test the entire seam length instead of a 1 m coupon. Thus, a peel test is essentially being conducted over the entire length of the seam to ensure the continuity and integrity of the entire seam. The relationship in Figure 1 is applicable to 0.75 mm (30 mil) thick PVC geomembranes of different colors, e.g., gray and black. Another important aspect of this air-channel testing is that the flexible nature of a PVC geomembrane allows visual inspection of the entire, inflated seam. This differs from air-channel testing on more rigid types of geomembrane; for those, the inflated channel cannot be as clearly seen. With PVC, the technician can view the seam inflate as pressure migrates along it. The inflated channel resembles somewhat an inflated inner tube; this distinctive behavior is referred to as tubing. If a weak spot is encountered and results in a leak, the air pressure may not fully inflate beyond that spot. Photo 2 shows a 0.75 mm (30 mil) thick PVC geomembrane with an inflated air-channel. Note the readily visible, inflated air-channel, how it maintains the air pressure. Another objective of this workshop was to refine the procedures for welding and air-channel testing of T or butt seams. Photo 3 shows the air-channel pressurized across the T seam (see arrow). The T seam does not have a detrimental effect on the inflated air-channel. Another benefit of air-channel testing of PVC seams is that problematic seams are readily visible. For example, Photo 4 shows a seam aneurysm that was discovered during the workshop. It s clearly visible to field personnel. Recommended test procedure This section presents a detailed procedure for conducting air-channel tests on field PVC seams. To facilitate dual-track welding and, thus, air-channel testing, it is recommended that the subgrade be smooth- drum rolled prior to placement of the PVC geomembrane. Before pressurizing the air-channel, a wedge-welded seam should be allowed to cool for five minutes. A hot air welded seam should be allowed to cool for about 10 minutes. These times are usually not problematic for production seams because of the length of typical production PVC geomembrane thickness 0.50 mm (20 mil) 0.75 mm (30 mil) 1.00 mm (40 mil) 1.25 mm (50 mil) 1.50 mm (60 mil) Maximum allowable air-channel pressure drop kpa (psi) 35 (5) 35 (5) 30 (4) 30 (40) 20 (3) Table 1. Air pressure inflation and maximum pressure drop schedule for PVC geomembranes. 2

seams. However, these times may require some waiting for short or trial seams. If the seam is pressurized before it cools, the seam may not be able to accommodate the required air-channel pressure (Figure 1). The waiting periods will likely be less in colder temperatures. In addition, care should be taken to ensure that no one stands or walks on a hot seam, as this might cause a blockage that prevents the entire seam length from inflating. After pressurizing the air-channel, the pressure in the seam should be allowed to stabilize before beginning the test. This stabilization period is usually one to two minutes long. After stabilization, the air channel should hold the pressure indicated by Figure 1 for at least 30 seconds to ensure that the seam satisfies the required peel and shear strengths. The required air-channel pressure is obtained by measuring the sheet temperature using a thermo-couple or laser/infrared thermometer to obtain the required air-channel pressure in excess of a 2.6 N/mm (15 lb/in) seam peel strength. The air-channel pressure obtained from Figure 1 is a minimum value. Of course, the air-channel can be pressured beyond the required value. Because of changes in weather conditions during the test and low elongation of the PVC material that can occur during the test, the air-channel pressure can change 35 kpa (5 psi) during the 30 second or greater holding period for a 30 mil PVC geomembrane. Table 1 presents the allowable air-channel pressure drop for other thicknesses of PVC geomembrane. Recommended repair procedure Defects If the air-channel does not hold the required pressure, a remedial measure must be applied to the field seam. The location of a leak can usually be readily determined by watching the air-channel inflate from the source to the clamped end of the seam. When the pressure reaches the defect, the channel may have difficulty inflating further. After the leak is located, the leak is repaired using the following procedure. The geomembrane is cut to remove the leak. The air channel is tested in both directions from the defect to verify the integrity of the remainder of the seam. If the seam passes the test in both directions, a patch is applied over the area of the leak. The patch should extend 15 cm on all sides of the leak. The patch can be adhered to the PVC geomembrane using a hot air welder (Photo 5) or a solvent weld. The patch should be tested using the air lance procedure as described in ASTM D4437. Aneurysms Photo 4 shows an aneurysm that can develop from the pressurized air intruding into the welded material. In most cases, the channel will still pressurize and maintain the required air pressure. However, to ensure the long-term integrity of the seam, it is recommended that the amount of incursion of the air-channel into the weld seam be measured and the remedial measure, if any, be a function of the percent intrusion into the weld. The intrusion is calculated by dividing the length of intrusion by the width of the unintruded weld. The following guidelines are presented for repairing an aneurysm: If air-channel incursion is less than or equal to 25% of the weld width, no remedial measure is required. If air-channel incursion is greater than 25%, the exposed flap of the geomembrane should be welded down to isolate the aneurysm. The flap should be sealed for a length of 15 cm on all sides of the aneurysm. The sealed flap can be tested using the air lance test described in ASTM Test Method D4437. The flap on the underside of the liner does not have to be seamed because the liquid will not reach the underside of the liner. Photo 4. Aneurysm in 30 mil PVC geomembrane seam. Photo 5. Hot air welding the upper flap of the geomembrane six inches above and below (see small tic mark near arrow) an aneurysm (large mark on sheet). Case history One project at which the air-channel testing of PVC geomembrane seams significantly reduced the number of destructive samples required from the completed liner is the Crown Vantage Landfill in Parchment, Mich. The project involves a 186,050 m 2 (2,000,000 ft. 2 ) final cover system for 3

two cells of a paper mill landfill (Photo 6). The first cell was an ash fill requiring 55,650 m 2 (598,040 ft. 2 ) of 0.75 mm (30 mil) thick PVC geomembrane. The geomembrane was placed directly on the fine, black ash material that was compacted on 3H:1V slopes of the cell. The second area was a waste cell that had been covered with 2 ft. of sandy soil. This cell required 130,825 m 2 (1,408,190 ft. 2 ) of PVC geomembrane. The liner was placed directly on the sand layer over the waste on slopes that varied from 5H:1V to 3H:1V. The smaller cell required 32 prefabricated panels to cover the footprint. The use of prefabricated panels resulted in only 2,500 meters of field seams for this cell. The Michigan Department of Environmental Quality (MDEQ) requires a destructive sample for every 150 m of completed seam for seams thermally welded in the field. MDEQ requires shear and peel testing on the destructive samples by a third party laboratory. Because air-channel testing was being conducted on this project and the relationship between air-channel pressure and seam peel strength (Figure 1) was available, MDEQ required only trial welds be performed by each machine at the start and conclusion of each welding session. This meant trial welds at start up in the morning, before shut down at noon, at start up after any break in welding, and before shut down at the end of the day. Only one destructive sample per Photo 6. Two cells at Crown Vantage Landfill were lined with PVC geomembrane. The seams were air-channel tested using the procedure described in this article. day for seam shear and peel strength testing was required regardless of the number of welders being used and regardless of the lineal meters of field seam completed in the day. This large reduction in the amount of destructive samples resulted in a better barrier because of the reduction in the number of patches. The much larger cell required 72 prefabricated panels to cover the 130,825 m 2 waste pile. Most of the panels for both cells were 30 m wide and 60 m long. Over 7,000 meters of field seam were required to weld the 70 together for the cell. While this amount of field seaming is significant, the length is about 70% less than the approximately 22,875 meters that would have been required if polyethylene membranes had been used. Air-channel testing of the dual-track PVC welds resulted in about 200 fewer destructive samples. That extraordinary reduction has resulted in a better completed barrier. Cell caps Ambient temperatures during construction of the smaller cell cap varied from 18 to 33 C (64 91 F). Sheet temperatures varied from 16 to 63 C (61 145 F) during welding operations. The larger cell cap was constructed in October, when the ambient temperatures ranged from 2 to 28 C (36 81 F). Sheet temperatures also varied greatly from a high of 4 to 49 C (39 120 F). Welder temperatures were set between 200 and 220 C (390 430 F) and welder speeds ranged from 1.5 to 2.5 meters per minute, depending on the sheet temperature. There were no destructive seam test failures on this portion of the project. The combination of rigorous trial weld testing and air-channel testing of the entire length of every field seam resulted in confidence that every meter of field seam exceeds the minimum strength specifications. Also, there were no air-channel test failures due to below-standard peel strength. The limited air-channel test failures that did occur were confined to holes in T seams where the loose flap of the intersecting field seam had not been trimmed properly. Conclusion The purpose of this article is to present a comprehensive procedure for air-channel testing of field PVC geomembrane seams for landfill liner and cover systems. The basis of the air-channel test procedure is the relationship between the required air-channel pressure to satisfy the specified peel strength (i.e., 2.6 N/mm) and the sheet temperature during air-channel testing presented by Stark et al. (2004). The procedure specifies the times for cooling of the thermally welded seam and stabilization of the air-channel pressure. The article also presents procedures for remediating seam defects and aneurysms. It is anticipated that this comprehensive procedure will facilitate the use of air-channel testing for field PVC geomembrane seams in landfill liner and cover systems. References ASTM standard D4437. 1999. Standard practice for determining the integrity of field seams used in joining flexible polymeric sheet geomembranes. ASTM International, West Conshohocken, Pa., vol. 04.13, pp. 13 15. ASTM standard D6392. 1999. Standard test method for determining the integrity of nonreinforced geomembrane seams produced using thermo-fusion methods. ASTM International, West Conshohocken, Pa., vol. 04.13, pp. 316 320. PVC Geomembrane Institute (PGI). 2004. PVC Geomembrane Material Specification 1104. University of Illinois, Urbana, Ill. 4

Stark, T.D., Choi, H., and Thomas, R.W. 2004. "Low Temperature Air-Channel Testing of Thermally Bonded PVC Seams," Geosynthetics International, vol. 11, no. 6, pp. 296 310. Timothy D. Stark is a professor of civil and environmental engineering at University of Illinois, Urbana, Ill., www.engr.uiuc.edu. John Heap is president of Colorado Lining International, www.coloradolining.com Stuart Lange is president of Lange Containment, www.langecontainment.com. Dave McLaury is president of DemTechServices Inc., www.demtech.net. Stan Slifer is vice president of Watersaver Inc., www.watersaver.com. 5