Instructions. Duct Mount Accessory Q Rev: 11/

Similar documents
INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

Instructions. Explosion Proof Smoke Detector U Rev: 9/

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

Smoke detection in hazardous areas:

Instructions xwatch Explosion-Proof Camera X /

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/

D2E Duct Smoke Detector

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Duct smoke housing, 2-wire D340/D340P

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Duct smoke housings, 4-wire D341/D341P and D342/D342P

SK-Duct Air Duct Smoke Detector

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

SEALED ENCLOSURE COOLING

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Instructions Det-Tronics Standard Gas Panel. 1.1 Rev: 10/

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

ColorMax Cyclone Cleaning Kit

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

Installation Instructions

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

D343. Installation Instructions. Air Duct Smoke Housing

DNRECL Eclipse Duct Smoke Detector

Installation Smoke Detector ELQZ , GOLD

Ebb & Flow System

E-PDD Duct Smoke Detector Installation Sheet

HE220, HE260 Humidifier Installation Kit

DH400 Air Duct Smoke Detector

INSTALLATION INSTRUCTIONS

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

Single stage operation oil burner

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Modular Drawer Cabinets Installation Instructions

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

INSTALLATION AND MAINTENANCE

Instructions. Nanotechnology Metal Oxide Semiconductor (NTMOS) H 2 S Gas Detector. 2.2 Rev: 6/

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

SAFETY AND INSTALLATION MANUAL MODEL 8100

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

BlueHeat AirTop 2000 Heater

Bathroom Exhaust Fan/Fluorescent Light Combination

Installation Instruction Venturi-Air Duct Kit. (Part No. S )

DH500 Intelligent Air Duct Smoke Detector Housing

Speaker Wall Mount (MSP-DCCSPM)

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Installation Instructions

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

FX-PDD Duct Smoke Detector Installation Sheet

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

DNR-AUS Duct Smoke Detector

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions 30 French Door Built-in Wall Ovens

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Nanotechnology Metal Oxide Semiconductor (NTMOS) H 2 S Gas Sensor

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

Bathroom Exhaust Fan/Fluorescent Light Combination

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

SECTION AIR DUCT ACCESSORIES

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

DH100ACDCI Ionization Air Duct Smoke Detector

569, 570, 571, 572 Series

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

installation, operation & Maintenance manual Floor-mounted Induction units

Installation Manual PS-225 & PS-275

DNR Duct Smoke Detector

Transcription:

Instructions Duct Mount Accessory Q5016 Rev: 11/16 95-8752

Table of Contents DESCRIPTION...1 FEATURES...1 OPERATION...1 SPECIFICATIONS.... 2 INSTALLATION... 2 Detector Location...2 Tools for Assembly...4 Tools for Detector Test... 4 INLET AND OUTLET TUBES...7 ASSEMBLING THE MONITORING CHAMBER. 8 AIR FLOW MONITORING............... 9 MAINTENANCE...9 DEVICE REPAIR AND RETURN....9 ORDERING INFORMATION...10 Q5016 PANEL ASSEMBLY MOUNTING...4 MOUNTING THE DETECTOR....6 SPARE PARTS....10 Spare Parts List....10 2 95-8752

INSTRUCTIONS DESCRIPTION The Detector Electronics Model Q5016 Duct Mount Accessory is used with the Model U5015 Det- Tronics SmokeWatch Explosion Proof Smoke Detector to detect smoke within air handling duct work. Mounted to the exterior of the duct wall, the Q5016 utilizes the differential pressure created between the inlet (sampling) and outlet (exhaust) tubes to drive a continuous air sample through the SmokeWatch measurement chamber. The Q5016 is provided with all necessary tubes and fittings to enable proper operation with a model U5015 SmokeWatch smoke detector (sold separately). The Q5016 is designed for hazardous industrial and commercial applications. Duct Mount Accessory Q5016 FEATURES Rugged design for environmental extremes Designed to operate effectively with smoldering and rapidly growing fires Has the ability to annunciate fault, ensuring no undisclosed failures Works with a small volume of air Designed to meet UL268A Can be installed horizontally or vertically OPERATION The Q5016 is an accessory that is used with the Det-Tronics U5015 SmokeWatch to provide smoke detection monitoring within duct work. Duct air velocity drives a cross-duct air sample into the upstream sample inlet tube, which in turn routes the air sample into the detector. The downstream air sample outlet tube returns the air sample back into the duct. The critical parameter for proper operation of the Q5016 is that all sample tubing connections and duct penetrations must be completely sealed and without any leakage. The mounting plate is provided with an NBR sheet gasket to ensure a proper seal on flat mounting surfaces. One inlet tube and one outlet tube are furnished with each accessory. Outlet tubes are 1 foot (0.3 meters) in length. The length of the inlet tube must be specified at the time of order and are available for ducts in the following widths: 1, 3, 6, or 9 feet (0.3, 0.9, 1.8, or 3.95 meters). The length of the inlet tube is determined by the width of the duct to be monitored. The inlet tube should span the entire width of the duct. Select the shortest inlet tube that exceeds the width of the duct to be protected. It can then be cut to the exact length during installation. Inlet tubes are.92 inch (.28 cm) outside diameter, and are notched on one end to enable proper installation into the access ports on the Q5016 mounting plate. The inlet tube includes small pre-drilled inlet holes, which must be aligned to face directly into the airflow (upstream) in order to capture airflow and generate proper differential pressure. Tubes are compression-fit into the body. A stop plug is provided for the end of the inlet tube to ensure that all airflow is directed towards the SmokeWatch detector. The Q5016 Smoke Duct Accessory works exclusively with the U5015 SmokeWatch smoke detector. For information on the operation, wiring and alarm of the U5015 smoke detector, please reference manual number 95-8723. Detector Electronics Corporation 2016 1 Rev: 11/16 95-8752

SPECIFICATIONS MATERIALS: BODY Aluminum, 6000 series. Finish: MIL-DTL-5541 Type II Class 1A SAMPLING TUBES Galvanized steel tubing.92 inch (2.34 cm) dia. Inlet tube: available for 1, 3, 6, or 9 foot (0.3, 0.9, 1.8 or 3.1 meter) wide ducts. Outlet Tube: 1 foot (0.3 meter) standard length tube. FASTENERS Stainless steel. DIMENSIONS Refer to Figure 1. AIR VELOCITY RANGE 300 to 4000 ft/min (91.44 to 121.92 meters/min). INGRESS PROTECTION Designed to meet NEMA 250 requirements for type 4X (Det-Tronics verified). ACCESSORY SHIPPING WEIGHTS Box 1 (Includes Q5016 Duct Accessory + one 1 ft outlet tube + box + instruction manual). Box 2 (Includes inlet tube in shipping container). Box 1 = 21.45 lbs. (9.73 kg). Box 2 = Will vary depending on the tube length and number of tubes. Individual Tube Weight: 1 ft = 0.65 lbs. 3 ft = 1.50 lbs. 6 ft = 2.85 lbs. 9 ft 8 in = 4.45 lbs. TOTAL INSTALLED WEIGHTS Includes Q5016 Duct Accessory + one outlet tube + one 3 ft. inlet tube + one U5015, 2-port model. Q5016-1 / U5015 = 22.1 lbs. (10.03 kg) Q5016-3 / U5015 = 22.95 lbs. (10.41 kg) Q5016-6 / U5015 = 24.3 lbs. (11.02 kg) Q5016-010 / U5015 = 25.9 lbs. (11.75 kg) 15.0 (38.1) 9.0 (22.86) INSTALLATION The Q5016 Air Duct Smoke Detector accessory mounts externally on any duct wall with the air inlet (sample) and outlet (exhaust) air tubes extending into the duct to provide a continuous cross sectional sampling of the air moving through the air handling system. DETECTOR LOCATION Detectors can be mounted in the supply system downstream of the filters, or in the return system at the point of entry into a common return duct (Figure 2). Whenever possible, detectors that are mounted on a return duct should be at a distance equivalent to six duct widths from any duct openings, sharp bends, branch connections, or deflection plates. For additional information regarding the location and spacing of duct smoke detectors, refer to the National Fire Protection Association (NFPA) Standard 90A, Installation of Air Conditioning and Ventilation Systems and NFPA Standard 72 for Automatic Fire Detectors. OUTLET DIRECTION A2700 6.8 (22.27) INLET DIRECTION Figure 1 Q5016 Dimensions in Inches (cm) 2 95-8752

STOP PLUG DUCT WALL DIRECTION OF AIR FLOW STOP PLUG DUCT WALL DIRECTION OF AIR FLOW A2707 Figure 2 Tube position and orientation 3 95-8752

Tools Required for Assembly and Mounting: 1/2 inch Box End, Socket, or Crescent Wrench 3/16 inch Hex Key 3/8 inch Hex Key 1-3/8 inch Open End, or Crescent Wrench Drill Drill bits -11/32 inch and 1-5/16 inch Center punch Hammer Panel mounting template (included) Access panel kit (if required) Tools Required for Detector Test: Calibrated manometer capable of measuring 0.015-2.4 inches (0.38 to 60.96 mm) of H 2 O Differential pressure adaptors 013655-001 Components for the Q5016 Accessory will arrive in two shipments. One will contain the duct mount assembly and outlet tube. The other will contain the inlet tube of desired length. See Figure 4 for parts call out. The U5015 Smoke Detector, which will be assembled to the Q5016 Duct Mount Panel Assembly, is sold separately. Q5016 PANEL ASSEMBLY MOUNTING 1. The Q5016 duct accessory should be installed in an easily accessible location approximately six ducts widths from bends, duct openings, or deflection plates (see Figure 3). These locations provide fairly uniform, non-turbulent air flow. If no access panel is present at the desired mounting location, an access opening will need to be created above or adjacent to the installation point to facilitate attachment of the Q5016 to the duct wall. NOTE To ensure proper operation of the sampling tubes, observe proper inlet and outlet tube position and orientation as illustrated in Figure 2. 2. Proper horizontal mounting orientation of the Q5016 occurs when the shoulder bolt is located in the lower right-hand corner of the smoke monitoring chamber assembly (test-fitting the smoke monitoring chamber onto the panel assembly may be required prior to mounting to discern proper tube orientation). If mounting vertically, mount so that the cover is able to swing downwards (note direction of airflow for inlet and outlet tube placement). BEND OR OTHER OBSTRUCTION LOCATION OPTION SIDE VIEW RETURN AIR INLET TYPICAL ACCESS PANEL LOCATION LOCATION OPTION LOCATION OPTION TYPICAL ACCESS PANEL LOCATION TYPICAL ACCESS PANEL LOCATION EXHAUST RETURN AIR DO NOT LOCATE DETECTOR HERE BOTTOM VIEW EXHAUST DAMPER TYPICAL ACCESS PANEL LOCATION RETURN AIR DAMPER FRESH AIR INTAKE SUPPLY AIR A2702 LOCATION OPTION FILTER BANK DO NOT LOCATE DETECTOR HERE NOTE: WHEN POSSIBLE, THE DETECTOR SHOULD BE LOCATED DOWNSTREAM FROM ANY DUCT OPENING, SHARP BENDS, DEFLECTION PLATES OR BRANCH CONNECTIONS. IF A LOCATION OPTION IS NOT POSSIBLE, LOCATE THE DETECTOR AS FAR AS POSSIBLE FROM THE OPENING, BENDS, DEFLECTION PLATES, ETC. Figure 3 Q5016 Placement in duct 4 95-8752

DUCT MOUNT PANEL ASSEMBLY SMOKE MONITORING CHAMBER ASSEMBLY OUTLET / EXHAUST TUBE (DOWNSTREAM) COMPRESSION NUT (2) BASE COVER 5/16 INCH FLAT HEAD BOLT (9) FLANGE HEAD LOCKING NUT (9) CAPTIVE SCREW (6) TOP STOP PLUG STANDOFF (2) INLET / SAMPLING TUBE (UPSTREAM) GUIDE SUPPORT / ACCESS PORT (2) U5015 SMOKE DETECTOR COMPRESSION NUT (2) SHOULDER BOLT A2701 Figure 4 Parts of the Q5016 assembly 3. Lay the fastening pattern template (Figure 5) onto the duct in a position to monitor the duct in a horizontal or vertical orientation. Ensure that there will be enough room to open the cover of the Q5016. 4. Center punch the hole locations. Remove template and, using an 11/32 inch drill bit, drill six clearance hole locations for the 5/16 inch screws. Using a 1-5/16 inch drill bit, drill two hole locations for the inlet and outlet guide supports. IMPORTANT If the duct is more than 3 feet (1 meter) wide, drill a 1-5/16 inch diameter hole directly opposite of the inlet access port on the opposing duct wall. This will be necessary to support inlet tubes that are longer then 3 feet (1 meter). After installation, seal opposing duct wall where the tube penetration occurred. 6.75 (17.14) 15.0 (38.1) 6.75 (17.14) 9.0 (22.86) HOLE POSITION FOR OUTLET TUBE 2 (AIRFLOW THIS DIRECTION) 1.0 (2.54) 3.75 (9.52) 1.0 (2.54) 1HOLE POSITION FOR OUTLET TUBE (AIRFLOW THIS DIRECTION) 3.75 (9.52) 6X Ø0.325 (0.825) 2X Ø1.250 (3.175) 5.50 (13.97) 5.50 (13.97) A2703 Figure 5 Q5016 Template dimensions in Inches (Centimeters) 5 95-8752

5. Remove the six lock nuts from the perimeter of the plate. The screws are threaded through the plate, and should remain in place (Figure 6). 6. Line up the panel assembly with the drilled hole pattern in the duct wall and insert the screws. Holding the panel in place, reach through the access panel opening, and thread the flange head lock nuts, onto the screws. Tighten with a wrench until secure. Washers or support plates can be added if additional support is needed before the lock nuts are applied. 7. Seal the access panel door, as additional assembly will be completed from the outside of the duct. FLANGE HEAD LOCK NUT (6) NOTE Prior to installation of detector please reference NEMA SB 13-2012 (Section 7.2) for more information for in-duct detectors MOUNTING THE DETECTOR 1. Remove the three flange head lock nuts on the plate (Figure 7). Place the U5015 Smoke Detector over the hole locations, centering it in the slots. Replace and fasten the nuts to secure the detector to the plate. 2. Remove the red transport cover from the U5015 Detector, if applicable. 3. Remove the sensor head and wire the unit according to the wiring instructions in the U5015 manual to the desired configuration. 4. Once wiring is complete, replace the sensor head and screw on the captive ring until it is fully seated. Replace and tighten the lock nuts. 5/16 INCH SCREW ASSEMBLED TO PLATE (6) Figure 6 Q5016 Duct mount panel assembly and hardware 5/16-18 THREADED STUD (3) CAPTIVE RING U5015 DETECTOR FLANGE HEAD LOCK NUT (3) Figure 7 U5015 Smoke Detector mounted on Q5016 plate assembly 6 95-8752

INSERT INLET AND OUTPUT TUBES 1. Working from outside the duct, loosen the hex compression nut on the mounting plate assembly for each access port in order to release pressure from the internal O-ring. 2. Insert the outlet tube into the correct access port (depending on air flow direction). Ensure that the notched end of the inlet tube is external to the duct wall and the tapered end is inside the duct. 3. From outside of the duct, insert the inlet tube into the correct access port. Ensure that the notched end is external to the duct wall and the end with holes is inside the duct. The stop plug must be installed. NOTE The inlet tube should span the entire length of the duct. If the inlet tube is too long, it will need to be cut to size, The overall length of the inlet tube should be approximately 4 inches (10.2 cm) longer than the width of the duct to accommodate installation through the access port and into the smoke monitoring chamber. NOTE When cutting an inlet (sampling) tube, always cut the end opposite of the notch (see Figure 8). If the end with the notch is cut, the tube will not seat in the connector fitting properly, and proper orientation may not be possible. Ensure that the end of the tube is then de-burred. When the inlet tube is cut to the proper length, install the stop plug securely into the end of the tube. See figure 9. IMPORTANT To ensure proper detector operation, it is essential that the stop plug be installed at the end of the inlet tube. CUT THIS END IF NEEDED NOTCHES STOP PLUG Figure 9 Inlet tube with stop plug Figure 8 Outlet and inlet tube notches 7 95-8752

ASSEMBLING THE MONITORING CHAMBER 1. Use a 3/16 inch hex key to unfasten the six captive screws in the cover from the base. (screws do not require removal from the cover). 2. Lift the cover from the base and swing it down to view the alignment keys for the inlet and outlet tubes, and to access the two socket head cap screws in the interior (Figure 10). 3. Line up the screws in the base to the standoffs on the plate assembly, and using a 3/8 wrench, fasten the socket head cap screws. This will compress the chamber gasket to the U5015 detector. 4. Position the inlet and outlet tubes into the access ports, rotating the notch on the inlet and outlet tube until it lines up with the their individual alignment keys inside each port. IMPORTANT The holes in the inlet tube must face the air flow in the duct (upstream). See Figure 2. 5. Tighten all four compression nuts until each O-ring is contacted, then tighten another onehalf turn to ensure that the nuts are tightened securely. 6. Swing the cover back up into position and fasten the captive screws. OUTLET TUBE (NOT SHOWN) COMPRESSION NUTS (4) STOP PLUG AIRFLOW 1/2-13 SOCKET HEAD CAP SCREW INLET TUBE ALIGNMENT KEYS 1/2-13 SOCKET HEAD CAP SCREW CAPTIVE SCREWS (6) COVER ALIGNMENT KEY Figure 10 Q5016 Assembling front cover to plate assembly 8 95-8752

AIR FLOW MONITORING The pressure differential between the inlet and outlet tubes should be tested with the detector mounted and air flowing through the duct (See Figure 12). 1. Loosen the six captive screws on the sampling chamber cover, allowing the cover to hang from the shoulder bolt. 2. Plug the flow monitoring adapters (figure 11) into the Q5016. Insert the manometer tubes onto the adapters, low side to the outlet tube adapter and high side to the inlet tube adapter using the air flow monitoring adapters. A2708 Figure 11 Flow monitoring adapter Figure 12 Manometer measurement example (Q5016 not installed) 3. Using a calibrated manometer capable of differential pressure measurement across the prescribed range, measure pressure differential. The measured differential should be 0.015 to 2.40 inches (0.38 to 60.96 mm) of H 2 O. NOTE If the pressure differential is not within the specified limits, air from within the duct may not flow past the U5015 smoke detector and improper performance may result. Check the installation to be sure that the outlet and inlet tubes are positioned and oriented properly. Increasing the air flow within the duct should increase the pressure differential, while decreasing the air flow will decrease the pressure differential. MAINTENANCE Per NFPA 72, the detector should be tested at least semi-annually to ensure proper operation using the procedure described in the Manual self-test section of the U5015 manual. Proper detector maintenance should also consist of cleaning dust and other contaminants from the inlet and outlet tubes. Pressure differential should be measured on a regular basis to ensure proper air flow through the detector enclosure. DEVICE REPAIR AND RETURN Prior to returning devices, contact the nearest local Detector Electronics office so that a Returned Material Identification (RMI) number can be assigned. A written statement describing the reason for return must accompany the returned device or component to expedite finding the cause of the failure. Pack the unit properly. Use sufficient packing material as protection from any damage. Return all equipment transportation prepaid to the factory in Minneapolis. 9 95-8752

ORDERING INFORMATION Q5016 Duct Mount Accessory, includes the following: Inlet sampling tube (Specify length at time of order. See below for available lengths.) Outlet sampling tube - 1 ft (0.3 m) Stop plug for inlet tube Instruction manual Model U5015 SmokeWatch Smoke Detector (Sold separately) Part Number Description 013901-001 Q5016-1 Duct mount w/ 1 ft (0.3 m) inlet tube 013901-003 Q5016-3 Duct mount w/ 3 ft (0.9 m) inlet tube 013901-006 Q5016-6 Duct mount w/ 6 ft (1.8 m) inlet tube 013901-010 Q5016-10 Duct mount w/ 10 ft (3.0 m) inlet tube SPARE PARTS Part Number Description 013660-001 1 ft (0.3 m) inlet tube 013660-003 3 ft (0.9 m) inlet tube 013660-006 6 ft (1.8 m) inlet tube 013660-010 9 ft 8 in (2.95 m) inlet tube 013628-001 1 ft (0.3 m) outlet tube 013653-001 Inlet tube stop plug 400587-001 Locknut, serrated flange 013655-001 Differential pressure adaptors (2X) 013626-001 Chamber gasket 013904-001 Mounting template For assistance in ordering a system to fit your application, please contact: Detector Electronics Corporation 6901 West 110th Street Minneapolis, Minnesota 55438 USA Operator: (952) 941-5665 or (800) 765-FIRE Customer Service: (952) 946-6491 Fax: (952) 829-8750 Web site: www.det-tronics.com E-mail: det-tronics@det-tronics.com 10 95-8752

This page intentionally left blank 11 95-8752

95-8752 FlexSonic Acoustic Leak Detector X3301 Multispectrum IR Flame Detector PointWatch Eclipse IR Combustible Gas Detector FlexVu Universal Display with GT3000 Toxic Gas Detector Eagle Quantum Premier Safety System Corporate Office 6901 West 110 th Street Minneapolis, MN 55438 USA www.det-tronics.com Phone: 952.946.6491 Toll-free: 800.765.3473 Fax: 952.829.8750 det-tronics@det-tronics.com All trademarks are the property of their respective owners. 2016 Detector Electronics Corporation. All rights reserved. Det-Tronics manufacturing system is certified to ISO 9001 the world s most recognized quality management standard.