Knight Trak II Instruction Manual

Similar documents
Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Chem-Trak Installation & Operation

Chem-Trak Jr. Instruction Manual

KLE-175 GT / KLE-150 GT

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

KLE-235D DOUBLE RACK IN-LINE CONFIGURATION KLE-175GTM SINGLE RACK THREE-DOOR CONFIGURATION KLE SERIES ULTRA WASH DISHMACHINE INSTRUCTION MANUAL

DEMA 830 Laundry Master TM Installation Instructions

DEMA 844 Laundry Master Laundry Chemical Dispensing

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

Laundry Dosing Systems

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

Alarm Tone Generator Model AG17

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

WAREMAX SERIES. Dosing Systems for Commercial Dishmachines. Contents. WAREMAX Series Dishwasher systems. 4 Priming and Delime Mode.

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

Model 4001 Series Single Channel Controller

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

RAM3 Remote Alarm Module

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

EVO192 v3.0 Fire and Burglary What s New

Networked Access Control Panel. Installation Guide

M770 ph Controller Owner s Manual

Mark 25 Ultrapure Water Conductivity Analyzer

PERMACONN PM1030 Includes DI300. Installation Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

ILS Max. Installation and Operating Manual TABLE OF CONTENTS

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

installation guide Dositec Electromagnetic Wall Mount - 1 Channel

LaserFOCUS VLF-250 Engineering Specification

1022 R/T Remote Monitor

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

! "! # Please read these installation and operating instructions completely and carefully before starting.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

DEMA Nitro Ware Wash Chemical Dispensing

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Installation, Operation & Maintenance Manual. Wash System

Section PERIMETER SECURITY SYSTEMS

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

INSTRUCTION MANUAL FOR DEMA CHEMASTER TM DM-813-LLL-1T, DM-813-LLL-2T, DM-813-DLL-1T and DM-813-DLL-2T

UNC100 Integra Manual

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Specification for On-Line UPS Battery Monitoring and Data Management System

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Air Resource Specialists, Inc.

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Remote Relay Module (RRM)

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Comfort Series Instant Hot Water System

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

CA5000 Liquid CO 2 Freezer Backup System

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

INTELLIGENT FIRE ALARM CONTROL PANEL

CO2 Sensor User and Installation Guide

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Sacksafoam Heli-Case Operations Manual - Version A Issue Date: April 2017 PLEASE READ BEFORE USING

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Control/Communicator

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

HARDwired Installation/ Owner s Manual

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

7-Day. Digital Thermostat. residential. & 2-cool

Freeze Alarm. General Description VD-6300-MCS / VD-6301-MCS. Applications. Features. Specifications. Dimensions

DEMA PROPORTIONER MODEL 167 & 167T INSTALLATION INSTRUCTIONS

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Long Range Radio Alarm Transmitter

RangerNET Network Ready Constant Monitor Model CM2815

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Owner s Manual RD432-0 Chemical Controller

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Multiple Washer Laundry Control System Pneumatic - Wall Mount - 1 Channel - Installation Guide

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

CARD ACCESS CONTROL SYSTEM

3226 Trunk Port FXO Doorphone

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Summit E & Summit XL Dispensers for small OPL to large laundry washer extractors and tunnels

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Figure 1. Figure 2. See notes 1 and 2 below.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Installation and Operation Manual. Model Q916

P2267 NETWORK INTERFACE

OPERATING MANUAL/ INSTALLATION

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

DEMAMaster Nitro Express Ware Wash Chemical Dispenser

OVEN INDUSTRIES, INC.

RK Carbon Monoxide Transmitter Operator s Manual

Frosty Factory of America, Inc.

Frequently asked questions: Intelligent Transmitter Series

D3000. Installation & Setup Guide

Transcription:

Knight Trak II Instruction Manual Page 1 of 16

7$%/(2)&217(176 Drawing-System Wiring Diagram... 3 Knight Trak II System Overview... 4 Drawing-POB Wiring... 8 Drawing-LFP Wiring... 9 Drawing-Control Connections for Multilinking... 10 The Signal Input Board (SIB)... 11 Drawing-SIB Connection... 12 The Management Input Board (LMIB)... 13 Network wiring Diagram... 15 CAUTION: Knight Trak II has high voltage connected to the transformer. Always disconnect main power when servicing the unit. Page 2 of 16

Page 3 of 16

6<67(029(59,(: The Knight-Trak II Data Management System represents the Next generation of laundry dispensing equipment with data tracking capability. On-site programming, centralized control, and the ability to export information to personal computers are just a few of the many enhancements provided by Knight- Trak II. Main control, programming, and report parameters are established with the Laundry Formula Programmer (LFP). The LFP permits programming for each dispenser that the laundry specialist is responsible for, and also allows the operator to select formulas or obtain load count information. The LFP also allows for programmed and reported data to be SAVED for printing at a later date. 7+(%$6,&6<67(0,1&/8'(6 A heavy duty stainless steel case, with peristaltic pumps and a Pump Output Board (POB), A Laundry Formula Programmer (LFP) which mounts on the front of the washer and provides the programmer/operator interface and battery backup for data, A Signal Input Board (SIB) which mounts inside washer and reduces high voltage supply signals to low voltage data signals. 6<67(0237,216 (1) A Laundry Management Input Board (LMIB), which receives hot and cold water signals and other information relating to wash cycle tracking, (2) A Low Level Alarm (LLA), which senses low chemical supplies and alerts washroom personnel, (3) A full-size 80 column printer, which provides printed information, (4) A Printer/Terminal Module (RM), which provides external storage/printing capabilities, (5) A Support Kit which includes cables and accessories in a durable, light-weight carrying case, (6) A Multi-Flow laundry chemical flush system, (7) The Reporter Software for Knight-Trak: Windows compatible software that allows a personal computer (PC) to perform many different functions (including remote programming, instant production status display, dispenser network printing, telephone modem functions, and more)..1,*+775$.,,35(,167$//$7,21 Before the equipment is installed you should survey the installation site thoroughly. At the very least, your survey should include the following. (1) Check to make sure that all functions of laundry machine are operating properly examples are: drain valve, hot/cold water solenoids, flush-down valves, water level switch, card reader or timer, machine motor. (2) Check the proposed location for a 115 or 230 VAC power source. Page 4 of 16

,167$//$7,21 (1) Remove the locking cover panel from the pump housing using the key provided. (2) Mount pump housing in a convenient location on a wall near supply containers. This location is usually near the laundry machine, however, can be mounted as a remote pumping system. Use proper mounting hardware and utilize appropriate mounting techniques for various types of walls (i.e. cement, sheetrock, etc). (3) Insure that the voltage of the system matches the main power voltage. (4) Its very important to measure signal voltage between signal wires and signal common (NOT ground ). This measurement must be taken when laundry machine is operating and when products are called for. (5) BEFORE CONTINUING TO NEXT STEP, DISCONNECT ALL ELECTRICAL CONNECTIONS TO LAUNDRY MACHINE, CARD READER, AND INJECTOR. VERIFY THIS WITH A VOLTMETER. (6) Inspect the wiring diagram for the laundry machine and card reader. They are available from the manufacturer upon request. (7) Gain access to the signal connections by removing the top or rear cover of the wash machine. Install the Signal Input Board (SIB) near the signal source and connect signal wires from the signal source to the SIB. Connect the SIB to the LFP. Connecting the SIB to the LFP requires a three-conductor shielded cable available from Knight Equipment. Color-coded connections on the LFP are marked to insure correct hookup. Conduit is not necessary as the SIB transmits low-voltage D.C. data signals. (8) Connect the LFP to the POB. Connecting the LFP to the POB requires a three-conductor shielded data cable available from Knight Equipment. Color-coded connections on the LFP and POB are marked to insure correct hookup. Conduit is not necessary as the LFP transmits low-voltage DC data signal. (9) Run all main power wires from the Pump Output Board (POB) to the power source through suitable conduit. Check local electrical wiring codes. $&&(6625<&211(&7,216 (1) In order for the Knight-Trak II to collect hot water, cold water, drain counts, and full wash cycle tracking information, connect a Laundry Management Input Board (LMIB) to the SIB. Connections are shown on both the boards and on the included wiring diagram. (2) In order to sense if one or more chemicals are low or out of product, connect a Low Level Alarm (LLA) to the POB. Connections are shown on both boards and on the included wiring diagram. (3) Strobe-Alarm (SA-12) provides audio and visual indication for chemical flush errors or low supply. Page 5 of 16

08/7,/,1.,1* Multilinking is a way to connect multiple Knight-Trak II dispensers in a laundry. Once connected, you can "talk" to all dispensers from a single connection. (1) Before connecting the multilinking cable, use the LFP to give each dispenser its own ID number. If dispensers on the multilink have the same ID number, they will not work correctly. THIS MUST BE DONE BEFORE YOU CAN "LOG-ON" WITH REPORTER PC SOFTWARE OVER THE NETWORK. (2) Using shielded cable, connect the multilink barriers on each POB in series. Be careful to keep the polarity the same on each dispenser. (3) A booster transformer must be used if multilinked dispensers are connected to a PC running with Reporter software. See Reporter network diagram included in this manual. 3&1(7:25.&$%/(,167$//$7,21 Connecting the Knight-Trak II dispenser network to an on-site PC requires plugging-in the network cable to the jack on the POB (Pump Output Board) and connecting other end to a wall-mount booster transformer and RM-6000. Please see diagram included in this manual for details. For laptop computers, connect the RM-6000 to the female jack on the LFP. remote location. See The Reporter Dispenser Network diagram (included in this manual) for more information on connecting modems to the network. Please refer to the RM-6000 or WinReporter instruction manual for actual setup of the remote modem. A dedicated phone line must be installed and connected to the on-site modem. NOTE: For installations that require telephone modem and on-site PC access, contact the sales office 5(3257(53&02'(0,167$//$7,21 Reporter Software features the ability to access dispensers from a remote location via telephone modems. A Hayes Acura 336 modem can be used along with a dedicated RM-6000 Reporter Module set in modem mode. Contact Knight Technical Services 1-800-241-7789 or 1-800-854-3764 for assistance. An RM-6000 Reporter Modem Cable (P/N 0300952) is required to access dispensers from a for details on special "Y" network cable. Separate RM-6000 s are required for the PC and modem (see diagram). Page 6 of 16

6(783$1'23(5$7,21 (1) Measure the distances from chemical supply container to pump housing and from pump housing to injection point inside the washmachine. (2) Insert one end of a suction tube into the left side of the squeeze tube in the leftmost peristaltic pump. (3) Cut the suction tube to length and insert other end into supply container using PVC pipe as a support. (4) Insert one end of the discharge tubing into the right side of the squeeze tube on each peristaltic pump. (5) If running pump outputs directly to the washer, form an antisiphon loop (with the loop pointing "down") with the other end of the discharge tubing and insert the end into the supply pocket of the machine. (6) If running a chemical flushing system, refer to the instructions provided with the system. For flush mode to work correctly, the flush terminals on the POB must be connected together with a jumper, or to a flow sensor. If this is not done, a flush error will result and the system will be disabled. To reset the system, push the reset button on the lfp. (7) Connect the 115 VAC or 230 VAC supply voltage to the system. (8) Program the system using the LFP. Detailed instructions regarding the programming of the system are located in the LFP Programming Manual. (9) For accuracy, when autocalibrating or testing flow rates, always measure chemicals at the washer. Product viscosity and tubing lengths will have a effect on the flow rates. (10) Operate the washer and inspect for proper function. If using auto formula select, ensure that correct formulas are chosen. Otherwise, use the FORMULA (up and down) buttons on the LFP to choose formulas. You will then be able to verify proper formula operation of the Knight-Trak II system. Page 7 of 16

Page 8 of 16

Page 9 of 16

Page 10 of 16

7+(6,% The Knight-Trak Signal Input Board (SIB) is an interface module which receives pump activation signals of 14 to 240 Volts from the washmachine and sends them as low-voltage data signals to the Knight-Trak II Dispenser. The module is available in 6, or 10 pump configurations. The SIB should be installed in the washer near the supply signal outputs. 6,%,167$//$7,21 (1) Inspect the wiring diagram for the laundry machine (and card reader, if required). They are available from the manufacturer upon request. In addition, you may refer to the Knight Equipment Laundry Interface Manual for connection information. (2) Measure the signal voltage between the signal wires and signal common (NOT case ground). This measurement must be taken when the laundry machine is operating and products are being called for. (3) BEFORE CONTINUING TO THE NEXT STEP, DISCONNECT ALL ELECTRICAL CONNECTIONS TO THE LAUNDRY MACHINE, CARD READER, AND INJECTOR. VERIFY THIS WITH A VOLTMETER. (4) Upon request, Knight Equipment provides a laundry wiring interface manual. Use this, a schematic of the machine, or consult the dealer for proper signal points. The SIB has provisions for split common connection (some washmachine's have provisions for separate wash and rinse commons). See the next page. (5) Connect the color coded interface wire (Knight part number #0300058) to the SIB with gray wire nuts. Connect the other end to the Laundry Formula Programmer (LFP) mounted on the front of the machine. Wires must be shielded and maximum wire length is 100 feet. Color-coded markings labeled SIB are on both boards. See the next page. (6) Housed inside the plastic module is a 1 amp fuse to protect both the SIB and LFP. Consult the factory if the fuse blows. (7) The SIB is equipped with signal indicator lights. When a signal of sufficient voltage and current (24-240v) is present the light will activate. This and a voltmeter are the best way to determine if a signal is present from the washer, and the wiring is correct. 6,%$&&(6625,(6 Some washmachines may have been provided with a toggle switch for selecting formulas. Other machines may need the addition of a toggle switch to select formulas. If this is the case, connect a toggle switch to the NO VOLTAGE - FORM SEL connections on the SIB. A momentary switch may be added for defeating bleach signals. Additionally, an optional RSB-1000 remote signal box can be used. The RSB-1000 provides both a formula select switch and a bleach defeat switch to defeat bleach signals from triggering bleach pumps. Page 11 of 16

Page 12 of 16

7+(/0,% The Knight-Trak II Laundry Management Input Board (LMIB) is an interface module which receives wash tracking information signals from the washmachine and sends them as low-voltage signals to the Knight-Trak II Dispenser. The module is connected to a Knight-Trak II Signal Input Board (SIB). THE LMIB IS TO BE INSTALLED BY CERTIFIED ELECTRICAL PROFESSIONALS ONLY. The LMIB accepts the following types of signals: DOOR INTERLOCK - This signal is used to generate start and finish time stamps in the wash cycle tracking report. Use a door switch, an light, or a track on a card reading machine. The signal only needs to be present at the start of the wash then just before the load count pump through to the end of the wash cycle. After the load count pump has been signalled the next time the door interlock signal is interrupted the finish time will occur. The door interlock signal may be interrupted before the load count pump as often as necessary. STEAM - This signal is used to determining auxiliary steaming or heating of water. Steam or heat signals are indications of additional time required to wash (many machines halt the normal wash cycle during steaming). The steam valve or relay is the source for the steam signal. DRAIN - This signal is used to count the number of drains in a given wash cycle. A drain solenoid or a drain track on a card reading machine are typical sources for the drain signal. COLD WATER - This signal is used to help track total cold water usage. Connect to the cold water fill valve or relay. HOT WATER - This signal is used to help track total hot water usage. Connect to the hot water fill valve or relay. /0,%,167$//$7,21 (1) Inspect the wiring diagram for the laundry machine (and card reader, if required). They are available from the manufacturer upon request. Schematic interpretation skills are a must. (2) Measure the signal voltage between the valves, tracks, switches, or relays and signal common (NOT case ground). Operate the washer and ensure the signals are correct and on at the right time. (3) BEFORE CONTINUING TO THE NEXT STEP, DISCONNECT ALL ELECTRICAL CONNECTIONS TO THE LAUNDRY MACHINE, CARD READER, AND INJECTOR. VERIFY THIS WITH A VOLTMETER. (4) Install the LMIB near the SIB and connect wires from the signal sources to the LMIB. The LMIB is equipped with signal indicator lights. When a signal of sufficient voltage and current (12-240v) is present the light will activate. (5) Connect the color coded LMIB wire to the LMIB wire on the SIB with grey wire nuts. LMIBs not mounted in a plastic housing have removable barriers for interconnecting. See page 12. (6) Housed inside the plastic module is a 1 amp fuse to protect the LMIB, SIB, and KOB. Consult the factory if the fuse blows. Page 13 of 16

Page 14 of 16

F LOW F LOW F LOW 3 CONDUCTOR NETWORK CABLE KNIGHT P/N 0300058 ONLY Data Flow Over Multi-Link Multi-Link Terminals BLACK TERMINAL BROWN TERMINAL CONNECT THE PLUG INTO THE JACK ON THE CIRCUIT BOARD IN ANY ONE OF THE MULTI-LINKED DISPENSERS. POB Circuit Board 3 CONDUCTOR NETWORK CABLE KNIGHT P/N 0300058-X ONLY (X = LENGTH OF CABLE) PC 12 VDC Booster Transformer Reporter Hardware Key Cable - Connects To PC Serial Port KCI-6000 or RM-6000 MALE FEMALE MALE WINREPORTER / 04-02-01 Page 15 of 16

',6&/$,0(5 Knight Inc. does not accept responsibility for the mishandling, misuse, or non-performance of the described items when used for purposes other than those specified in the instructions. For hazardous materials information consult label, MSDS, or Knight Inc. :$55$17< All Knight controls and pump systems are warranted against defects in material and workmanship for a period of ONE year. All electronic control boards have a TWO year warranty. Warranty applies only to the replacement or repair of such parts when returned to factory with a Knight Return Authorization (KRA) number, freight prepaid, and found to be defective upon factory authorized inspection. Bearings and pump seals or rubber and synthetic rubber parts such as O rings, diaphragms, squeeze tubing, and gaskets are considered expendable and are not covered under warranty. Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equipment. Product abuse or misuse voids warranty..1,*+7,1& A Unit of IDEX Corporation World Headquarters: 20531 Crescent Bay Dr. Lake Forest, CA 92630-8825 USA TEL: (949) 595-4800 FAX: (949) 595-4801 Atlanta Branch: 8111 Technology Dr. NE Covington, GA 30014 USA TEL: (770) 787-9400 FAX: (770) 787-1155 Toronto Branch: 2880 Argentia Road, Unit 6 Mississauga, Ontario L5N 7X8 Canada TEL: (905) 542-2333 FAX: (905) 542-1536 London Branch: #15 Brunel Centre Newton Road, Crawley West Sussex UK RH102UB TEL: (44) 1293-615570 FAX: (44) 1293-615585 Sydney Branch: Unit 28, 317-321 Woodpark Rd., Smithfield NSW Australia 2164 TEL: 61-29-725-2588 FAX: 61-29-725-2025 Amsterdam Branch: Marssteden 68 7547 TD Enschede The Netherlands TEL: 31-53-428-58-00 FAX: 31-53-428-58-09 Page 16 of 16