SAFETY CONTROL REQUIREMENTS FOR OVENS AND FURNACES

Similar documents
Commercial/Industrial Combustion Control Level Three Announcement

Take The Test! Does Your Boiler Meet Code?

DIRECTIVE NO: D-B

NFPA 86 Commitee Inputs Page 1 of 45

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

First Revision No. 106-NFPA [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

7800 SERIES RM7888A Relay Module

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

The Committee updated the edition dates for the reference sources for extracted text within the standard per the NFPA Manual of Style.

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

7800 SERIES RM7840E,G,L,M Relay Module

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

Power Flame Incorporated

Electronic Thermostat

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Committee on NFPA 85

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

CHAPTER 10 STEAM AND HOT WATER BOILERS

SECTION GAS-FIRED RADIANT HEATERS

7800 SERIES RM7888A Relay Module

Honeywell Primary Control Cross Reference

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

Power Flame Incorporated

YP7899C SERIES Burner Management Panel

C6097A,B Pressure Switches

CSD-1 COMMERCIAL BOILER CONTROLS

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

ADF/ADFH 300 and 500

The key element for your process

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Honeywell Thermal Solutions COMBUSTION CATALOG

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION

Engineering Standard. Saudi Aramco DeskTop Standards

IS Series Pressure Sensing Switches

A. Product Data: Include rated capacities, furnished specialties and accessories.

7800 SERIES EC7885A/RM7885A Relay Module

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Q382A,B Pilot Burners

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

STR-Series Indirect-Fired Air Turnover Units

Why AC800M High Integrity is used in Burner Management System Applications?

Instructions For A and Flame Simulators

NFPA 96, 2017 REVIEW SUMMARY

COMBUSTION CATALOG. Honeywell Thermal Solutions Honeywell Thermal Solutions Combustion Catalog

7800 SERIES Relay Modules

Technical Committee on Fluidized Bed Boilers

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

ECLIPSE INFORMATION GUIDE

RM7897A,C 7800 SERIES Relay Modules

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2006 EDITION

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

Flame Safeguard Fault Code Diagnostics

7800 SERIES EC7823/RM7823 Relay Module

RM7890A1056, RM7890B SERIES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Operating Manual. PRO 1000 Series EFS-01. Non-Programmable Thermostat

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

Sola Hydronic Control. An Eco-Friendly Solution.

C7004B Flame Rod Holder

Model CB-LE. Packaged Boiler HP. Operation, Service, and Parts Manual /09. and Model CB Ohio Special HP

D896 Automatic Vent Damper

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Honeywell SLATE ICM Platform

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

Second Revision No. 3-NFPA [ Section No. 2.3 ]

PACKAGED COMMERCIAL WATERTUBE BOILERS

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Revitalize Building Mechanical Systems (4619)

**************************************************************************

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Inventory Management Guide

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Kolmetz Handbook Of Process Equipment Design BURNER MANAGEMENT SYSTEMS (ENGINEERING DESIGN GUIDELINE)

LFL Series Burner Flame Safeguard Control

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

NFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf

R7120M 7800 SERIES Relay Modules

SERIES 19A. mith PRESSURIZED WET BASE

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

Technical Committee on Fluidized Bed Boilers

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Transcription:

SAFETY CONTROL REQUIREMENTS FOR OVENS AND FURNACES SAFETY CONTROL REQUIREMENTS The NATIONAL FIRE PROTECTION ASSOCIATION is organized to promote the science and improve the methods of fire protection and prevention, to obtain and circulate information on these subjects, and to secure the cooperation of its members in establishing proper safeguards against loss of life and property by fire." The NFPA standards are developed by committees of people selected for their technical competence and interest. The objective of the standards is to reduce the loss potential in terms of life, property and production. The NFPA standards are only advisory publications. However, they are widely referenced by public jurisdictional authorities, testing agencies and insurer organizations. The 2007 edition of NFPA 86 continues to bring the standard into compliance with the for Industrial Furnaces Using a Special Processing Atmosphere, and NFPA 86D, Standard forindustrial Furnaces Using Vacuum as an Atmosphere, into NFPA 86. This new, combined document provided one standard for ovens and furnaces of all types. In addition, the standard was revised to comply with the Manual of Style for NFPA Technical Committee Documents. Chapter 2 now contains all referenced publications, and Chapter 3 contains all definitions. The 2007 edition of NFPA 86 continues to bring the standard into compliance with the Manual of Style for NFPA Technical Committee Documents and to update requirements where needed, as follows: (1) Requirements for logic systems and programmable logic controller based systems wereprovided to replace a requirement that programmable logic controllers be specificallylisted for combustion safety service. Listed controllers are no longer available. (2) Unenforceable text was either revised to be enforceable, deleted, or relocated to Annex A. (3) Where appropriate, repetitive text was replaced by a table. (4) Coverage of operations and maintenance requirements throughout the standard were relocated from former Chapter 14, Inspection, Testing and Maintenance. The chapter was renamed Commissioning, Operations, Maintenance, Inspection, and Testing and relocated to Chapter 7. APPROVAL PROCEDURE NFPA does not review, inspect, or approve equipment, plans or installations and therefore has no procedure for doing so. In instances where it is necessary to meet NFPA standards, the authority having jurisdiction will have established a procedure for the review and approval of systems. Contact the appropriate authority early in the planning stage of a project to ensure that all submissions and inspection schedules can be maintained. NATIONAL FIRE PROTECTION ASSOCIATION-86 70-8227-01

Table 1. SUMMARY OF REQUIREMENTS (This publication is intended only as a convenient reference to general combustion control requirements of NFPA 86. For information regarding other requirements such as ventilation, oxygen enhancement, etc., refer to the NFPA Standard directly. NFPA 86: Ovens and Furnaces, Classes A, B, C and D System Control Specifications Gas-fired Oil-fired Associated Standard Paragraph Recommended Controls INTERLOCK/LIMITS Operating Controller Temperature Required Required NFPA 86: 8.17 L4006A, L4008A High Limits Temperature Required Required NFPA 86: 8.16 L4006E High Fuel Gas Pressure NFPA 86: 8.8.2 C6097B, C437D Low Fuel Gas Pressure Required NFPA 86: 8.8.1 C6097A, C437E High Oil Pressure NFPA 86: 8.8.2 L404T Low Oil Pressure Required NFPA 86: 8.8.1 L404V High Oil Temperature NFPA 86: 8.11 Low Oil Temperature Required NFPA 86: 8.11 Manual Supervisory Cock Atomizing Media Required NFPA 86: 8.10 Rotating Cup Drive Valve Seal Overtravel Interlock (POC) NFPA 86: 8.7, (VPS 8.7.2), ref. V4055D,E/V5055C,E 3.3.3.64.6 High Fire Switch Integral to M9484D,E,F; M9494D Low Fire Switch NFPA 86: 3.3.33 Integral to M9484D,E,F; M9494D Low Liquid Cutoff NFPA 86: 13.2.6.8 Supervise Purge Air (pre ignition airflow) NFPA 86: 8.4.1 C6097, C437 Proven Combustion Air Required Required NFPA 86: 8.6 C6097, C437 Ventilation Fan Interlock NFPA 86: 8.5 13 13 Oxygen Enhancement 0 2 Interlocks NFPA 86: 6.4, 10.2 14 14 Valve Proving System Optional NFPA 86: 3.3.74; 7.5.9; 8.7.2; 8.7.2.2 PILOT VALVE TRAIN Approved Satety Shutoff Valve(s) One or two required One or two required NFPA 86: 8.7 V4046C/V8046C Manual Shutoff Valve(s) Required Required NFPA 86: 6.2.5.1 (gas); 6.3.5.1 (oil) Normally Open Vent Valve Leak Test Valve Required Required NFPA 86: Annex A7.5.9 Pressure Regulator Required Required NFPA 86: 6.2.7 70-8227 01 2

NFPA 86: Ovens and Furnaces, Classes A, B, C and D System Control Specifications Gas-fired Oil-fired Associated Standard Paragraph Recommended Controls MAIN VALVE TRAIN Approved Safety Shutoff Valve(s) One or two required One or two required NFPA 86: 8.7 V4055/V5055/V5097 (gas only) Firing Rate Valve Optional Optional NFPA 86: 6.2.8 (gas); 6.3.6 (oil) Manually Operated Leak Test Valve(s) NFPA 86: Annex A7.5.9 V9055/V5055B/V5097B (gas only) V51E/M9484 (gas only) Manual Shutoff Valve(s) Required Required NFPA 86: 6.2.5.1 (gas); 6.3.5.1 (oil) Normally Open Valve Vent Pressure Regulator Required Required NFPA86: 6.2.7 AUXILIARY EQUIPMENT Auxiliary Equipment Required Required NFPA 86: 5.5 Oxygen Enhanced Combustion Optional Optional NFPA 86: 6.4 Ventilation Optional Optional NFPA 86: 8.5 Alarms Required Required NFPA 86: examples - 10.1.8.8; 12.1.3.6; 12.3.4.1 Combustibles/0 2 Analyzer N.O.x Analyzer Draft Control System APPROVED SAFETY CONTROL SPECIFICATIONS Prepurge Required Required NFPA 86: 8.4 Prepurge Timing Prepurge Air Changes 11 11 Required Required NFPA 86: 8.4 4 4 NFPA 86: 8.4 High Fire Purge Proving Circuit Low Fire Start Circuit 12 12 NFPA 86: 3.3.33 Continious Pilot Optional Optional NFPA 86: 3.3.48.2 Intermittent Pilot Optional Optional NFPA 86: 3.3.48.3 Interrupted Pilot Optional Optional NFPA 86: 3.3.48.4 Direct Ignition Optional Optional NFPA 86: 8.15 Proved Pilot Required Required NFPA 86: 3.3.48.5 Pilot Flame Establishing Period (PFEP) Main Flame Establishing Period (MFEP) 15 seconds maximum 15 seconds maximum NFPA 86: 3.3.49; 6.2.10.4; 8.9; 8.4.2; 6.2.11 15 seconds maximum 15 seconds maximum NFPA 86: 6.2.10.4; 6.2.11; 6.3.8.4; 8.4.2; 8.9 Supervise Main Flame Required Required NFPA 86: 8.9 3 70-8227 01

NFPA 86: Ovens and Furnaces, Classes A, B, C and D System Control Specifications Gas-fired Oil-fired Associated Standard Paragraph Recommended Controls Flame Failure Response Time 4 seconds maximum 4 seconds maximum NFPA 86: 8.9 (FFRT) NFPA 86: 8.2 Action on Flame Failure Safety shutdown (lockout) Action On Limit Opening Safety shutdown (lockout) Post Purge Recommended Approved 15 Safety Control R7795, R7140 RM7895,6,7,8 RM7840 RM7800 RM7838B, C Safety shutdown (lockout) Safety shutdown (lockout) R7795, R7140 RM7895,6,7,8 RM7840 RM7800 RM7838B, C NFPA 86: 8.3.1.2; 8.3.2.1 70-8227 01 4

Footnotes: Class A - An oven or furnace that has heat utilization equipment wherein there is a potential explosion or fire hazard that could be occasioned by the presence of flammable volatiles or combustible materials processed or heated in the furnace. Class B - An oven or furnace that has heat utilization equipment wherein there are no flammable volatiles or combustible materials being heated. Class C - An oven or furnace that has a potential hazard due to a flammable or other special atmosphere being used for treatment of material in process. Class D - An oven or furnace that is a pressure vessel that operates under vacuum for all or part of the process cycle. Whenever the normal fuel pressure to the pressure regulator immediately upstream from the safety shutoff valve exceeds the design limits of the burner system, a high pressure switch shall be provided and interlocked with the burner system s safety shutoff valve. If any specific input, or limited range of inputs is required for safe ignition, the fuel control valve shall be properly positioned and interlocked prior to each and every attempt at ignition. On circulating liquid systems, limit switches in addition to the low liquid cutoff shall be provided to shut off the heater automatically if liquid temperature is excessive and if circulation rate is low. If pilot is used. When main or pilot fuel gas burner system capacity exceeds 400,000 Btu/h, two safety shutoff valves (piped in series) shall be used. If main or pilot gas burner capacity is 400,000 Btu/h or less, a single safety shutoff valve may be used in place of the double safety shutoff valves Exception: With a radiant tube-fired burner system, a single safety shutoff valve may be used. Position indication shall be provided for safety shutoff valves to main burners in excess of 150,000 Btu/h. Two safety shutoff valves should be provided under any one of the following conditions: (a) when the pressure is greater than 125 psi; (b) whenever the fuel oil pump operates without main oil burner firing, regardless of the pressure; (c) with combination gas/oil burners when the fuel oil pump operates during the fuel gas burner operation. A permanent and ready means for making tightness checks of all main burner fuel gas safety shutoff valves shall be provided. An audible and/or visible alarm shall be provided in the safety circuit to give warning of unsafe conditions or interruption of the safety circuit 11 At least four standard cu ft of fresh air per cu ft of oven volume shall be introduced during the purge cycle. 12 For burners that cannot be safely ignited at all firing rates encountered, positive provision shall be made to reduce the burner firing rates during light-off to a level that will assure a smooth and reliable ignition of the main flame (forced low-fire start). 13 Required when used. 14 Required when oxygen-enhanced combustion is used. 15 Select proper safety control on basis of system requirements. SUPPLY VOLTAGE REQUIREMENTS NFPA 86: 4-13 Electrical Power; 8.3.22 Safety control circuits shall be DC or single phase AC, 250 volt maximum, one side grounded, with all breaking contacts in the ungrounded, fuse (or circuit breaker) protected line. REFERENCE-NFPA 86: Ovens and Furnaces 2009 Edition. 5 70-8227 01

70-8227 01 6

7 70-8227 01

Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.honeywell.com U.S. Registered Trademark 2010 Honeywell International Inc. 70-8227 01 E.K. Rev. 03-10 Printed in U.S.A.