Australian/New Zealand Standard

Similar documents
Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

AS AS Australian Standard. Installation of fire hose reels. This is a free 6 page sample. Access the full version online.

Australian/New Zealand Standard

AS/NZS 3133:2008 AS/NZS

Australian/New Zealand Standard

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

AS/NZS 4012:1999 AS/NZS

AS/NZS 3190:2011 AS/NZS

Australian/New Zealand Standard

AS/NZS :2012. Regulatory compliance mark for electrical and electronic equipment AS/NZS :2012. Part 1: Use of the mark

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Australian/New Zealand Standard

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

Australian Standard. Fire detection, warning, control and intercom systems Control and indicating equipment. Part 1: Fire

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508

Australian/New Zealand Standard

AS/NZS :2014

AS/NZS :2014

Australian/New Zealand Standard

Australian/New Zealand Standard TM

AS/NZS :2009

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

Australian/New Zealand Standard

AS/NZS 4234:2008 AS/NZS

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :2014

AS/NZS TR IEC :2012

AS/NZS IEC :2013

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

Australian Standard. Fire protection for mobile and transportable equipment AS AS

AS/NZS 3957:2006 AS/NZS

AS/NZS IEC :2015

Australian/New Zealand Standard

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

Household and similar electrical appliances Safety

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

AS/NZS :2015

Australian/New Zealand Standard

Interim Australian Standard

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

Australian/New Zealand Standard

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

AS/NZS :2016

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

AS/NZS IEC 62560:2014

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

AS AS Australian Standard. Soils for landscaping and garden use. This is a free 7 page sample. Access the full version online.

AS/NZS :1998 AS/NZS ISO

AS/NZS :2011. Household and similar electrical appliances Safety AS/NZS :2011. Part 1: General requirements

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

AS AS Australian Standard. Potting mixes. This is a free 7 page sample. Access the full version online.

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

AS/NZS :2008

Australian Standard. Security screen doors and security window grilles AS AS 5039

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016

Substations and high voltage installations exceeding 1 kv a.c.

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

AS/NZS IEC :2016

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

Australian/New Zealand Standard

Australian/New Zealand Standard

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

AS/NZS :2014

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells

AS/NZS IEC :2016

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

AS Australian Standard. Guards and patrols. This is a free 6 page sample. Access the full version online.

Australian/New Zealand Standard

AS/NZS 2: 1067:2003 AS/NZS

Australian Standard. Safeguarding of machinery

AS/NZS ISO/IEC :2012

AS/NZS TR IEC :2012

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

AS/NZS IEC :2014

AS Australian Standard. Portable fire extinguishers Guide to servicing. This is a free 7 page sample. Access the full version online.

Australian/New Zealand Standard

Medical electrical equipment

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

Australian/New Zealand Standard

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

Transcription:

AS/NZS 3019:2007 AS/NZS 3019:2007 Australian/New Zealand Standard Electrical installations Periodic verification

AS/NZS 3019:2007 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL-001, Wiring Rules. It was approved on behalf of the Council of Standards Australia on 26 October 2007 and on behalf of the Council of Standards New Zealand on 23 October 2007. This Standard was published on 5 November 2007. The following are represented on Committee EL-001: Association of Consulting Engineers Australia Australian Building Codes Board Australian Electrical and Electronic Manufacturers Association Canterbury Manufacturers Association New Zealand Communications, Electrical and Plumbing Union Consumers' Federation of Australia Electrical Contractors Association of New Zealand Electrical Regulatory Authorities Council Electrical Safety Organisation (New Zealand) Electrical and Communications Association (Queensland) ElectroComms and Energy Utilities Industries Skills Council Energy Networks Association Engineers Australia Institute of Electrical Inspectors Ministry of Economic Development (New Zealand) National Electrical and Communications Association New Zealand Council of Elders New Zealand Electrical Institute Telstra Corporation Limited Keeping Standards up-to-date Standards are living documents which reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been published since the Standard was purchased. Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Web Shop at www.standards.com.au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in the on-line catalogue. Alternatively, both organizations publish an annual printed Catalogue with full details of all current Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For information about these services, users should contact their respective national Standards organization. We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comments to the Chief Executive of either Standards Australia or Standards New Zealand at the address shown on the back cover. This Standard was issued in draft form for comment as DR 06932.

AS/NZS 3019:2007 Australian/New Zealand Standard Electrical installations Periodic verification Originated in New Zealand as NZS 3019(Int):2002. Second edition NZS 3019:2004. Third edition AS/NZS 3019:2007. COPYRIGHT Standards Australia/Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher. Jointly published by Standards Australia, GPO Box 476, Sydney, NSW 2001 and Standards New Zealand, Private Bag 2439, Wellington 6020 ISBN 0 7337 8423 2

3 AS/NZS 3019:2007 PREFACE This Standard was prepared by the Joint Standards Australia/Standards New Zealand Committee EL- 001 Wiring Rules. The Standard aims to provide persons who carry out periodic verification, by inspection and/or testing, with the means to determine, as far as reasonably practicable, whether the installation and all its constituent equipment is in a safe condition for continued use, and that the electrical installation complies with safety requirements for the prevention of fire and the protection of persons and livestock from electric shock. AS/NZS 3019 may be applied through legislative requirements, made in each State and Territory of Australia and in New Zealand, concerned with the safety of electrical installations, that require certain electrical installations to be inspected and tested from time to time. Additionally, verification of an electrical installation may be requested by the owner/occupier or another organization. This Standard differs from the previous New Zealand-only edition, NZS 3019:2004, in that three levels of verification are specified: by basic visual inspection, by visual inspection and limited testing, and by visual inspection and full testing, rather than the verification of specific types of installations. Verification of caravans and pleasure craft previously covered will be contained in the new editions of AS/NZS 3001 and AS/NZS 3004 Part 2 respectively, which are expected to be published in 2008.

AS/NZS 3019:2007 4 CONTENTS SECTION 1 Scope and general 1.1 Scope... 5 1.2 Types of verification covered... 5 1.3 Referenced documents... 6 1.4 Definitions... 6 1.5 Interpretation...6 SECTION 2 General requirements 2.1 Reporting of electrically unsafe installations... 7 2.2 Previous records... 7 2.3 Verification requirements... 7 2.4 Danger to persons or livestock... 7 2.5 Adequacy of overcurrent protective devices... 7 2.6 Instruments... 7 2.7 Qualification... 7 2.8 Frequency of periodic verification... 7 2.9 Reporting of periodic verification... 8 SECTION 3 Verification by basic visual inspection 3.1 General... 9 3.2 Inspection requirements... 9 SECTION 4 Verification by visual inspection and limited testing 4.1 Verification requirements... 10 4.2 General... 10 4.3 Switchboards... 10 4.4 Main earthing conductor... 11 4.5 Fixed wired appliances... 11 4.6 Overhead lines... 11 4.7 Testing requirements... 12 SECTION 5 Verification by visual inspection and full testing 5.1 Requirements... 14 5.2 Polarity... 14 5.3 Polarisation... 14 5.4 Insulation resistance... 14 5.5 Earth fault loop impedance... 14 5.6 Protective device fault rating... 14 5.7 RCD verification... 14 5.8 Integrity of switchboard connections... 15 5.9 Testing of final subcircuits supplied from an electrically separated supply... 15 APPENDIX A Periodic verification report forms (Informative)... 16 COPYRIGHT

5 AS/NZS 3019:2007 STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND Australian/New Zealand Standard Electrical installations Periodic verification SECTION 1 SCOPE AND GENERAL 1.1 Scope This Standard sets out the requirements for periodic verification of existing electrical installations which are connected to a low voltage a.c. supply system (exceeding 50 V a.c. but not exceeding 1000 V a.c.). Verification, by inspection and/or testing is intended, as far as reasonably practicable, to determine whether the installation and all its constituent equipment is in a safe condition for continued use. NOTE Inspection and testing to this Standard should provide evidence that the installation complies with the relevant requirements at the time of construction of the installation. This Standard does not apply to the periodic verification of the following electrical installations: (a) Installations designed and constructed to the AS/NZS 3000 provisions relating to specific design and installation. Refer to the verification specification prepared for the installation as required by AS/NZS 3000; (b) Installations of the following types: (i) Relocatable installations and their site installations. Refer to AS/NZS 3001 (ii) Marinas and pleasure craft installations. Refer to AS/NZS 3004 (iii) Hazardous areas. Refer to AS/NZS 2381.1 and AS/NZS 61241 series (iv) Electro-medical areas. Refer to AS/NZS 3003, and in New Zealand only, the provisions of NZS 3003.1 (v) Shows and carnivals installations. Refer to AS/NZS 3002 (vi) Construction and demolition sites. Refer to AS/NZS 3012 In New Zealand it does not apply to: (c) (d) (e) Electrical installations and equipment which operate at non standard voltages and frequencies. Refer NZS 6114; Mobile electro-medical relocatable installations. Refer NZS 6115; and Areas of electrical installations where electrical animal stunning or meat conditioning occurs. Refer to NZS 6116. NOTE Periodic testing of appliances is covered by AS/NZS 3760. 1.2 Types of verification covered This Standard provides for verification by: (a) (b) (c) Basic visual inspection; Visual inspection and limited testing; and Visual inspection and full testing. COPYRIGHT

The remainder of this document is available for purchase online at www.saiglobal.com/shop SAI Global also carries a wide range of publications from a wide variety of Standards Publishers: Click on the logos to search the database online.