Similar documents

AEROFOIL AXIAL FLOW FANS

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

ACN SMOKE INSTALLATION AND MAINTENANCE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

English CNA-CNB. Centrifugal fans Installation and maintenance

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

OWNERS INSTRUCTION MANUAL

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

AXPR Wall Mounted Axial Panel Fans

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

AP-EH500-L/RQA9837. Installation Guide

SUBMERSIBLE DIRTY WATER PUMP

Hand Dryer Installation & User Manual

Installation and Wiring Instructions

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

OPERATION AND MONTAGE MANUAL ROOF FANS

18 INCH HIGH VELOCITY FLOOR FAN

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

OPERATION AND MONTAGE MANUAL ROOF FANS

SURFACE WARM CEILING HEATERS

Panel Fan Series Operators Manual (Galvanized and Polymer)

FLUEBOOST. flueboost 350 gas fire model

SP16. 08/50740/1 (UK) - Issue 1

XB-EFA-8L-BK & XB-EFA-8R-BK

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

JMP Series Plate Mounted Axial Flow Fans

READ AND SAVE THESE INSTRUCTIONS

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

TopMaster Air Handling unit. Installation instructions

IEC- Direct-driven radial fans with IEC-Standardmotor

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Instructions for the BASIC BCRW Fan, Sizes General

Installation and Operating Manual Drying Cabinet

Commercial Fan Heater

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

This label warns for risk of electrical shock when failing to observe.

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Lo-Carbon T-series Window & Roof Models

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

WYND DC 54 CEILING FAN Installation Manual

Installation, Operation & Maintenance Instructions Document Ref:

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

THE QUALITY BRAND IN FANS

OPERATING & MAINTENANCE INSTRUCTIONS

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

Installation Instructions & Operating Manual IMPORTANT

Owner s Guide and Installation Manual

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

24 & 30 INCH DRUM FANS

Supply air unit VEKA Installation & Maintenance

Model: Ecostrad Thermostrip with Remote

INSTALLATION INSTRUCTIONS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

F6102 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

WHHR Midi & Midi Lite

DEVIL CERAMIC SPACE HEATERS

THE QUALITY BRAND IN FANS

INSTALLATION INSTRUCTIONS USER GUIDE

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

TTV 4500 / TTV 4500 HP / TTV 7000

HEAT RECOVERY AIR HANDLING UNIT

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Installation Instructions

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

Assessment Schedule - TS8

WC141 Integrated Dishwasher Installation, Use and Maintenance

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

40cm Pedestal Fan with Remote Control

Surface Warm Ceiling Heaters

Panel Fan Series Operators Manual (Galvanized and Polymer)

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

CTE9. Extractor. Installation, use and maintenance.

Transcription:

EC Box Fan www.flaktwoods.com/oandm Safety, Installation, Operation and Maintenance Instructions

CONTENTS Paragraphs Safety 1 Handling/Storage 2 Installation (Mechanical) 3 Fig. 1: Fig. 2: Tilt Mechanism Inverted Feet Installation (Electrical) and Operation 4 Switch-On 5 Maintenance 6 Fig. 3: Fan Assembly Fig. 4: Fan Disassemble Fault Finding 7 Electrical 7.1 Mechanical 7.2 Disposal 8 Product Information 9 Table 1: Power Ratings, Full Load Currents and Max Temperatures Electrical Connection Diagram 10 Fig. 5: Connection Diagram EC Box Fan and IFan Controller Installation Examples 11 Fig. 6: Floor Mounted - All Sizes (Correctly Mounted) Fig. 7: Ceiling Mounted - Spigot Sizes 125, 150, 200 and 250mm only (Correctly Mounted) Fig. 8: Ceiling Mounted - Spigot Sizes 125, 150, 200 and 250mm only (Correctly Mounted) Fig. 9: Wall Mounted Vertical Air Flow Up, 125, 150, 200 and 250mm only (Correctly Mounted) Fig. 10: Wall Mounted Vertical Air Flow Down (Incorrectly Mounted) Fig. 11: Wall Mounted Horizontal (Incorrectly Mounted) 1

1 Safety 1.1 Only approved, qualified personnel familiar with the assessment of hazards and risks associated with fans, and with the use of tools and test equipment required to service such fans, should install, operate and maintain the product. 1.2 If either an installer or user has any doubt that they can make a safe and reliable installation, or operate and maintain the equipment, Fläkt Woods Limited or their representative should be contacted for advice. 1.3 All warning and safety information contained within this document should be read before working on the fan assembly. 1.4 The product is designed to operate up to the maximum temperature detailed in the product information table in the Product Information section. 1.5 Each product is delivered with a Declaration of Conformity that should be retained with the fan. 1.6 The product is manufactured specifically to fulfil a particular application/environment. No deviation from the original requirement should be implemented without referring to Fläkt Woods Limited. Should a fan failure occur whilst the product is under warranty, the Fläkt Woods Limited service centre should be contacted, and supplied with full fan nameplate details, before any repair work is undertaken. 2. Handling/Storage 2.1 On receipt of the product we recommend that it is checked against what was ordered. Before fully unpacking the product please check that it has not been damaged during transit (deformed casing, damaged controller). When unpacking, to gain access to the fan, care should be taken to avoid injury from sharp edges, burrs, nails, staples, splinters etc. The fan packaging should be considered as a protective device only. 2.2 The product can be heavy and sometimes unwieldy (centre of gravity not central), and should therefore be lifted slowly to prevent damage and distortion. Lift unit into position using spreaders or slings, ensuring you have the appropriately rated equipment for the weight of the unit. WARNING! The mounting brackets, plastic handles or packaging must not be used as lifting devices when slinging the unit. 2.3 The stored product must not have equipment stacked on it, and it must not be stacked on other equipment. The packaging must not be used as a lifting device unless otherwise indicated (such as a pallet). The product should be stored in a safe, clean, dry, vibration-free location. 2.4 If the product is to be stored for 12 months or more, an inspection by Fläkt Woods Limited service centre before installation is advised. 3. Installation (Mechanical) 3.1 It is recommended that suitable safety guards form part of the installation wherever necessary. 3.2 We recommend that an air filter is fitted within the ductwork to reduce the accumulation of dirt on the fan impeller. An excessive build up of dirt could lead to imbalance of the impeller and vibration problems. 3.3 Where the product is delivered packaged, the packaging must be considered as a protective device only, and must not be used as a lifting aid unless otherwise indicated. During lifting all personnel must be clear of the area below the suspended fan. 3.4 An airflow indication arrow is shown on the fan nameplate. Sharp bends in the ductwork close to the fan must be avoided. Adequate room must be allowed round the fan for safe inspection and future maintenance, and the environment must be safe for both the fan, and for personnel. 2

3.5 Care must be taken to ensure that during extremes of wet and windy weather any ingress of water through the fan will not reach sensitive or hazardous areas within the building. 3.6 The component parts of the product, including anti-vibration mounts, flexible connectors (and their clips), weather proofing, platforms, supported drop rods and chains etc (if fitted), must be fully aligned before being bolted together so that no distortion or stress is placed on the equipment. 3.7 A minimum of 8 x M8 bolts, with the correct torque applied, must be used to secure the fan into position. The final position of the fan must be strong and rigid enough to take the weight of the fan and any other weight applied during installation. 3.8 Lagging should be applied between the box fan and silencer, around the connecting joint, to ensure maximum acoustic damping. 3.9 The product can be slightly tilted (to a maximum of 10 degrees) when used externally so that water runs off lid. Fig. 1 3.10 Spigot sizes 315, 450, 630 & 1000 x 600mm are not suitable for mounting in any other orientation than in the standard horizontal position (with the removable lid at the top). See section 11 for diagrams. 3.11 The box fans mounting feet can be inverted to decrease overall height. Fig. 2 Box fan can be adjusted at this fixing point 3.12 When connecting silencers to the box fan spigot use a positive mechanical connection such as riveting or self drilling screws to form a rigid connection. Flexible connectors should be used between the box fan and silencer. 3

4. Installation (Electrical) and Operations 4.1 The product contains rotating parts and electrical connections, which can be a danger and cause injury. If there is any doubt that a safe and reliable installation of the fan can be assured, Fläkt Woods Limited or their representative should be contacted for advice. See section 10 for connection diagrams. 4.2 All connections should be made by an appropriately qualified electrician. Connection details are provided with the product. It is good practice to fit a clearly marked lockable isolator switch close to the fan, and have a clearly marked and accessible push button stop/start switch on a control panel located remotely from the fan. The two switches allow safe control of the fan, provide a means of safely isolating the fan (until a controlled restart is made); they protect personnel during maintenance, during a fault situation, or during a mains failure/fluctuation. A suitable earth must also be connected. 5. Switch-On 5.1 Only appropriately qualified personnel should switch-on the fan. Before switching on confirm that the electrical supply is fully compliant with the requirement of the product as detailed on the motor nameplate, that the product is correctly installed, all component parts and fixings are secure, safety guards are in place and no loose items are present in the vicinity of the box fan. 5.2 Immediately after switch-on we recommend that the product is checked for smooth, low-vibration running, that the current consumption is within the full load current specified on the nameplate, and that the motor is not getting excessively hot. Check that the impeller is rotating in the correct direction. The box fan must not be switched on and off in a manner that could cause overheating of the motor, and could damage the insulation of the motor and the internal wiring to the motor. 6. Maintenance 6.1 No maintenance work should be attempted before switching off and completely isolating the product and its controls from all electrical supplies. Also allow the rotating parts of the fans to come to rest and the motors to cool. 6.2 It is essential to ensure that all fixings on the product are secure. 6.3 The complete fan/motor assembly can be easily removed for cleaning purposes. Fans should be disconnected from the controller prior to removal. Under no circumstances should the interior space and fan unit be cleaned with water or high-pressure steam. Fig. 3 Fig. 4 Remove lid to access fans Remove bellmouth first, then unscrew motor 4

6.4 After maintenance ensure that no loose items are present in the vicinity of the fan, that all safety guards, chains, drop rods etc, are properly secured into their original location, and that any temporary device used to stop the fan impeller rotating has been removed. 6.5 Information on all aspects of overhaul/extended maintenance is available from Fläkt Woods Limited service centre. After overhaul/extended maintenance the box fan must be safely and correctly installed back into its original position in accordance with this document. 7. Fault-finding Fault-finding must be carried out on the product by appropriately qualified personnel using the correct tools and equipment. If in doubt please seek advice from Fläkt Woods Limited. 7.1 Electrical 7.1.1 Isolate the box fan and controls from the electrical supply, check that the electrical connections to the product are secure and wired in accordance with the connection diagram, 7.1.2 Check that the voltage applied to the product is as specified on the box fan nameplate. 7.1.3 Connect an ammeter (clamp meter) in line with each phase (one phase in the case of single phase motors) of the box fan in turn and check that the current consumption is within the full load current specified on the product nameplate. 7.1.4 Ensure that there is no smell of burning in or around the vicinity of the motor. 7.1.5 Check the integral fuses within the ifan controller. Refer to ifan manual. 7.1.6 Three phase units also have additional MCB protection to each motor and a separate MCB that provides a single phase supply to the controls circuit. These are found in a separate enclosure inside the unit. 7.2 Mechanical 8. Disposal Check that these are in a healthy state before undertaking more in depth fault finding. Before any of the following checks are made isolate the fan and controls from the electrical supply. 7.2.1 Check that there is no obstruction to the fan impeller, that the blades are clean, and no loose items or debris is present in the vicinity of the impeller and inlet/discharge. 7.2.2 Rotate the fan motor shaft by hand. Investigate any sound of internal chaffing, rubbing or resistance. Any resistance to smooth rotation may indicate that the bearings require replacement. 7.2.3 Ensure that all fixings are secure. When the box fan has completed its working life the metal components should be segregated and recycled. The remaining items of material should be safely disposed of in accordance with local health and safety regulations. 5

9. Product Information Spiggot Size Speed Rev./Min. Standard Product Number Phase Frequency Max. Temp. Motor Rating (kw) Full Load Current (A) 125 Ø 3200 EC012211 1 Ph 50Hz +60 o 0.83 0.75 150 Ø 3200 EC015211 1 Ph 50Hz +60 o 0.83 0.75 200 Ø 2200 EC020211 1 Ph 50Hz +60 o 0.82 0.70 250 Ø 3390 EC011120 1 Ph 50Hz +60 o 0.54 3.39 315 Ø 2430 EC021120 1 Ph 50Hz +40 o 0.505 3.10 450 Ø 1350 EC031120 1 Ph 50Hz +60 o 0.64 2.90 450 Ø 1560 EC043120 3 Ph 50Hz +60 o 1.01 1.60 630 Ø 2050 EC053120 3 Ph 50Hz +40 o 2.8 4.35 600 x 1000 1400 EC063120 3 Ph 50Hz +40 o 2.9 4.65 10. Electrical Connection Diagram Connection Diagram EC Box Fan and ifan Controller. Fig. 5 ALARM RELAY ALARM RELAY L N E A1 A 2 +10V 0-10V GND L N E A1 A 2 +10V 0-10V GND NC COM NC COM L1 N E REGN 0-10V 0V RUN L1 N E RE GN 0-10V 0V RUN PLUG INTO MOTOR 1 SOCKET PLUG INTO INVERTER SOCKET 1 PLUG INTO MOTOR 2 SOCKET PLUG INTO INVERTER SOCKET 2 I-FAN TERMINALS I-FAN TERMINALS 0-10Vdc Output to fan 2 0-10Vdc Output to fan 1 6

11. Installation Examples Floor Mounted All Sizes (Correctly Mounted) Fig. 6 Ceiling Mounted Spigot Sizes 125, 150, 200 and 250mm only (Correctly Mounted) Fig. 7 NB: When mounting on the ceiling in the normal position, please ensure suitable drop rods are used. 7

Ceiling Mounted: Inverted Spigot Sizes 125, 150, 200 and 250mm only (Correctly Mounted) Fig. 8 NB: When mounting in the inverted position, the cover of the ifan can be inverted to ease access to the control panel. Wall Mounted Vertical Air Flow Up Sizes 125, 150, 200 and 250mm Only (Correctly Mounted) Wall Mounted Vertical Air Flow Down All Sizes (Incorrectly Mounted) Fig. 9 Fig. 10 8

Wall Mounted Horizontal All Sizes (Incorrectly Mounted) Fig. 11 9

NOTES 10

We Bring Air to Life Fläkt Woods Group provides a full range of products and solutions for buildings ventilation, air treatment and industrial air movement Sales Offices available World Wide - See our website for details www.flaktwoods.co.uk Sales Office Sales Office Head Office Fläkt Woods Ltd Unit 6240, Bishops Court Solihull Parkway Birmingham B37 7YB Tel: +44 (0)121 717 4680 Fax: +44 (0)121 717 4699 Fläkt Woods Ltd First Floor, Entrance 6, Crossford Court Dane Road, Sale, Cheshire M33 7BZ Tel: +44 (0)161 969 1992 Fax: +44 (0)161 969 4612 Fläkt Woods Ltd Axial Way Colchester Essex C04 5ZD Tel: +44 (0)1206 222 555 Fax: +44 (0)1206 222 777 Due to a policy of continuous development and improvement the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order. Copyright, Fläkt Woods Ltd, 2011. All rights reserved. No part of this publication may be produced in any material form by any means without the written permission of Fläkt Woods Ltd. Any unauthorised use of this data may result in legal proceedings. FWCG/0413/V3/PN404413