KADO LUX LED EXHAUST FAN 200

Similar documents
KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

MILLI CUBE HEATED TOWEL RAIL 825 X 600

ISSY GLIDE VANITY UNIT

Lucci Designer Hi Flow Exhaust Fan

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

2.9kW Portable Air Conditioner

2.9kW Portable Air Conditioner

PRODUCT SPECIFICATION GUIDE

BAYSIDE JETSTREAM CEILING FAN

LUCCI AIRFUSION SHOALHAVEN CEILING FAN

ERR627SA ERR927SA. Rangehood Installation manual

LUCCI AIRFUSION MARINER CEILING FAN

LUCCI WHITEHAVEN DC CEILING FAN

LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN

BAYSIDE NAUTILUS CEILING FAN

LUCCI AIRFUSION TAKEKO CEILING FAN

AIRFUSION MOONAH SERIES CEILING FAN

LUCCI FUTURA MOOD LED CEILING FAN

FUTURA SERIES CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

BAYSIDE CALYPSO CEILING FAN

General Care and Safety Guide

LUCCI AIRFUSION BANKSIA DC CEILING FAN

LUCCI AIRFUSION AIRMOVER CEILING FAN

FUTURA ECO SERIES CEILING FAN

General Care and Safety Guide

80cm Tower Fan With Remote Control

REHR6* WRH605I* WRH608I* WRR614*A WRH908I* Retractable Rangehood User manual

10cm Desk Fan User Manual

LUCCI ALTITUDE ECO LED CEILING FAN

MILLI PURE VERTICAL TRIPLE HEATED TOWEL RAIL 900X38 - CHROME

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

LUCCI AIRFUSION ARIA CEILING FAN

AERO SERIES CEILING FAN

PANEL HEATER OPERATING INSTRUCTIONS. For Model: CELEPANELD

FANAWAY LED EVO1 RETRACTING BLADE CEILING FAN

Lo-Carbon Quadra Centrifugal Fan

BATHROOM 2017 HEATING CATALOGUE

General Care and Safety Guide

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

FANAWAY CLASSIC CEILING FAN

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

RSA2CL6SS model pictured

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA

Wall Mounted BBQ GRHM & GRHL

Platinum Series Electronic Panel Heaters

V80-H Multistage Pump Instruction Manual

General Care and Safety Guide

Operating Instructions. Oil Column Heater. Models: GOC155, GOC157, GOC1511

Ceramic Wall Heater With Remote

FRANKE DESIGNER GAS COOKTOP 90CM

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Operating Instructions

LUCCI NORDIC DC CEILING FAN

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

20L Electronic Dehumidifier

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

HS&S Alert No: 103 Date: 9 March 2017

Convection Panel Heater

Tastic. User Guide. Heat Vent Light. Model: Original Model: Triumph 3 in 1 (275 W) Model: Triumph 3 in 1 (375 W)

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

Eco Tastic. User Guide. Heat Vent Light. Model: Eco Triumph Model: Eco Sensation Model: Eco Silhouette

s l it l on for Infrared Heaters

FAN HEATER FH118 User Manual

USER MANUAL COOKING. Model: WRG920FGS. Rangehood

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Electronic Ceramic Tower Heater

Ceiling Mounted Ducted Exhaust Fan Kit

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

LUCCI AIRFUSION FRASER DC CEILING FAN

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Centrif Duo & Centrif Duo Plus

e Bath Fan with Light User s Guide

fñxv tä VÉÅÅxÇwtà ÉÇ The DraftStoppa TopHat AT200D DraftStoppa TopHat AT200D(240V) Product of the Year

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

INSTALLATION INSTRUCTIONS USER GUIDE

VADA - Rain2Main Automatic Rainwater Controller

INSTRUCTIONS AND WARRANTY

HYDROTHERM FLOOR TO CEILING - SERIES

INSTALLATION INSTRUCTIONS USER GUIDE

RHK52_IB_FA_ Part No. T HERITAGE VOGUE KETTLE 2 YEAR WARRANTY RHK52 SERIES

Ecostrad Amalfi. Wall-mounted Infrared Heater INSTALLATION & OPERATING INSTRUCTIONS. 3kg 2 Years (excludes lamp & remote control) IP65

Model pictured: RPA3CI6SS/WH

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

User Manual. Compact Bagged Vacuum Cleaner. Dog & Cat W2000

Bathroom. Architectural Designer Products EVE COLLECTION

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

INSTRUCTION MANUAL. Mistral Fan /92646/92647 P.1. 3xGU10 MAX 50W

EH0533 Indoor Climate Control

YEAR 2WARRANTY. Windsor Kettle MODEL RHK3 INSTRUCTIONS & WARRANTY RHK3_IB3_281011

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

BLOW DRY & GO HAIR KIT

Transcription:

page 1 of 5 272mm 240mm 170mm 272mm 221mm 98mm Dimensions are nominal measurements only. SPECIFICATIONS Recommended use Material Colour availability Fascia Size Weight Domestic, Hotel and Commercial ABS Plastic/Stainless Steel White, Titanium 272 x 272mm 2.2kg Exhaust Air Movement Air Outlet Size 30w side ducted 40 L/sec (143m 3 /H)* 100mm LED Light Cutout Size Min Install Depth Install Type IP Rating 10 watt LED Panel 240mm diameter round 200mm AC Plug and lead included IPX4 To see the complete KADO range go to www.reece.com.au/bathrooms *All Airflow data has been gathered in accordance with International Industry Standards. CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions. PART NO. REECE CODE REX200WHL White 2053298 REX200SSL Titanium 2053300 Also see: REX250WHL/SSL for higher airflow REX200WH/SS for no light version Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 1

page 2 of 5 TECHNICAL SPECIFICATIONS EXHAUST Air Delivery Motor Power Noise Level Ball Bearing Duct Outlet Size Draft Stopper LIGHT Light Type Light Wattage Lumens Light Colour (CCT) LED Driver 40 L/sec (143m 3 /H)* 30 watts 38dB(A) Yes 100mm Yes LED Panel Light 10 watts 642Lm 4200K Natural White LVS12C25 Static Pressure (pa) 210 Duct Length in 190 REX250L relation to airflow 170 10m (approx only) 150 8m6m 130 4m 110 REX200L 2m 90 70 4m 6m 50 2m 30 0 m 3 /H 30 60 90 120 150 180 210 240 270 300 330 360 L/sec 8 17 25 33 42 50 58 67 75 83 92 100 Airflow *All Airflow data has been gathered in accordance with International Industry Standards. INCLUDES 1 x Exhaust Unit INSTALLATION Cut Out Size 240mm Diameter Round 1 x Cutout Template Fascia Size 272 x 272mm Rec Min Install Depth 200mm PACKAGING Packaging Size Gross Weight 290 x 290 x 225mm 2.3kg IP Rating Installation Type Power Supply IPX4 Splash Resistant AC Plug and Lead Included 220-240V ~50Hz AVAILABLE SPARE PARTS AND ACCESSORIES Part Number Supplier Description V100DKIT Ventair Ducting Kit with 1 x Ø100mm Grille and 3m Aluminium ducting. VAD100 Ventair Ø100mm x 3m Aluminium Ducting. V150PALG Ventair Premium Aluminium External Vent VTROTIMER Ventair Fully adjustable 1-25min exhaust fan run-on timer. VTMSENSOR Ventair Infrared motion sensor with 1-5m detection range and 1-20min runon timer.

page 3 of 5 INSTALLATION INSTRUCTIONS Please read these instructions carefully before installing and using the product. Keep the instructions handy for future reference. LOCATION The unit must be located and installed in accordance with AS/NZS 3000 and local building codes relating to damp situations. The unit can be installed in flat ceilings with a minimum height of 2 metres. At least 200mm height clearance in the ceiling cavity is required to ensure sufficient ventilation for moisture to disperse. Ensure adequate inlets exist through windows, vents or under the door for airflow. Regulations concerning the discharge of air must be fulfilled. POWER AC220~240V, 50Hz electrical supply is required. The unit can be connected to a lighting or power circuit if loading permits. All electrical work must be carried out in accordance with AS/NZS 3000 or latest edition thereof, and local building codes and regulations. Ensure that supply power is isolated before commencing installation. IMPORTANT CONSIDERATIONS 1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. Or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 2. Children should be supervised to ensure that they do not play with the appliance. 3. Fan must be installed at least 1200mm above any hotplate and must have at least 500cm clearance at the exhaust outlet. 4. Do not install fan in locations that may get extremely hot. 5. Ensure the fan has at least 20mm clearance in the ceiling space before installing. 6. Minimum installation height is 2100mm from the floor to the bottom of the exhaust fan. 7. If the room where the fan is to be installed already contains a stove, water heater or a gas fire, it is essential to ensure that air supply to the room is enough for both the fan and the combustion appliance. 8. Please check the appliance has not been damaged during transportation. 9. Check the electrical specifications label corresponds to your electrical supply. 10. When using double pole switch connection, the switch must have a minimum 3mm separation on all poles. 11. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similar qualified person in order to avoid a hazard. 12. When adding duct, avoid bending the duct in the following shapes: 13. Adhere to the latest national wiring rules AS/NZS3000, for wiring and when installing in bathrooms, nearby sinks and water taps. 14. For the exhaust fan to work effectively, replacement air of volume equivalent to what is being extracted must be able to enter the room. In general, this air would be drawn under the door or through a slightly open window. If the room is air tight, the fan will function poorly. 15. Before commencing any cutting, check in the mounting location so that there is no obstruction such as ceiling frames or joints, and that there is sufficient height clearance for the housing. Check the electrical wiring can be routed from the wall switch to the mounting location. 16. This fan is not intended for mounting in outside windows or walls.

page 4 of 5 INSTALLATION INSTRUCTIONS WARNING: AN ALL-POLE DISCONNECTION MUST BE INCORPORATED INTO THE FIXED WIRING IN ACCORDANCE WITH THE WIRING RULES AS OUTLINE IN CLAUSE 7.12.2 OF AS/NZS 60335-1 FOR MEETING THE MINIMUM ELECTRICAL SAFETY OF THIS STANDARD. Warning: Ensure the power supply to the exhaust fan is switch OFF before carrying out any installation and maintenance. Note: A double pole disconnection switch must be included in the electrical wiring of the exhaust fan. 1. Check the fan is free to rotate. 2. Cut the hole for the fan according to the template provided. 3. Attach the LED Light: a. Remove the double sided tape and attach the LED Driver onto the fan body. (See Figure 3a) b. Plug the fan and LED driver into a socket outlet and pull through the LED output connector with the hole provided. (See Figure 3b) Note: The two socket outlets and electrical wiring to an ON/OFF wall switch must be pre-installed. Please arrange a licensed electrician to prepare the socket outlet and an ON/OFF wall switch before carrying out the installation of this fan. c. Secure the fan body using the three clips, tightening the screws to secure the fan body to the ceiling. Now securely connect the LED lamp male connector and LED driver connector. (See figure 3c) d. Push the LED cable connector through the hole so that the connectors are in the ceiling cavity. See Diagram. 4. Secure the panel/fascia by squeezing the spring fasteners and insert into the slot in the fan body. Check that the panel is secured firmly and closely to the fan body. LED Lamp and LED driver are replaceable. To replace, disconnect female and male connectors and replace with new LED lmap or LED driver. To avoid overheating, DO NOT cover the LED driver with roof insulation. Note: Switch ON the fan and check for excessive vibration in the fan. If the fan runs in a sound way without abnormal noise, then install the panel. The vent duct should be declined downwards by about 10 degrees. ELECTRICAL WIRING Grounding Yellow/Green Terminal Yellow/Green Black or Purple Figure 3a. Attach the LED Driver Power ~ Blue Brown Fuse Blue Brown Motor Supply N Earth Figure 3b. Pull through connector 240VAC L Supply N Earth 240VAC L LED Light & Fascia Figure 3c. Connect LED connections Electricians, please ensure a copy of the installation instructions is left with the end user for future reference

page 5 of 5 CARE AND MAINTENANCE Make sure the fan is always switched off before cleaning. Make sure to use the fan with the specified voltage as stated on the rating label. Use the fan in a dry place, avoid excess humidity and water. Never immerse any part of the fan in water or other liquids. Never use petrol benzene or other such chemicals. Never allow water to contact the electrical parts such as switch and motor. Never immerse blades or other resin parts in hot water over 60 o C. Never install the fan in extremely hot environments. REECE PRODUCT QUALITY GUARANTEE You have purchased a quality product from Reece Pty Ltd ABN 84 004 097 090 ( Reece ). This product is covered by a 7 year replacement product warranty including a 24 month replacement warranty on spare parts (LED light and fascia). 7 YEAR WARRANTY DOMESTIC USE This warranty covers faults in the product construction, material and assembly. Products which are within 7 years from the date of purchase, found upon inspection by an authorised Reece representative, to be defective in construction, material or assembly, will be repaired or exchanged with an equivalent product free of charge. Replaced items become Reece s property. All replacement products will be available for collection without charge to the customer at the nearest Reece branch to the customer s location, or elsewhere as agreed between the customer and Reece. 24 MONTH WARRANTY - SPARE PARTS All spare sparts, which are within 24 months from the date of purchase, found upon inspection by an authorised Reece representative, to be defective in construction, material or assembly, will be replaced free of charge. Warranty Conditions This warranty will apply only under all of the following conditions: The item has been installed for and subjected to domestic residential use only Failure is due to a fault in the manufacture of the product Proof of purchase (including the date of purchase) is provided The installation of the product is in accordance with the instructions provided This warranty does not include faults caused by: Unsuitable or improper use Incorrect installation or installation not in accordance with the instructions provided Normal wear and tear Inadequate or complete lack of maintenance Chemical, electrochemical or electrical influences Harsh detergents or abrasive cleaners used on product finishes 1 YEAR WARRANTY COMMERCIAL USE Commercial use is all use other than for normal domestic residential purposes, including use in non-business places as in public buildings, schools, sports centres and in establishments that contain private bathrooms with high frequency of use by many individuals, such as hotels, motels, retirement villages and hospitals. The Commercial warranty covers this product against manufacturing faults in the construction, material and assembly of both the finished products and any spare parts for a period of 1 year from the date of purchase. Products and spare parts which are found upon inspection by an authorised Reece representative to be defective in construction, material or assembly will be repaired or exchanged free of charge. Replaced items become Reece s property. The Warranty Conditions and exclusions which apply to the domestic use warranty also apply to this commercial warranty. EXCLUSIONS To the fullest extent permitted by law, Reece excludes all liability for damage or injury to any person, damage to any property, and any indirect consequential or other loss or damage. CLAIM PROCEDURE For all warranty queries customers are to contact Ventair Pty Ltd on 1300 665 926 or visit http://ventair.com.au/warranty Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.