G&F Manufacturing Service Manual Version 2.0 April 2010

Similar documents
INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

SERVICE MANUAL FOR MODEL RM-49

INSTALLATION INSTRUCTIONS

SERVICE MANUAL FOR MODEL RM-26

SERVICE MANUAL FOR MODEL RM-10

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

HP50HA ABG Heat Pump

INSTALLATION INSTRUCTIONS

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Installation, Operation, and Maintenance Information

347002K/177002K/34900

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Quick Start Guide. For product manuals and further installation / operation procedures visit

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

INSTALLATION INSTRUCTIONS

(EE1500, EE2000, EE2500, EE3000)

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

Owner s Manual PRINTED IN CANADA 05/2009

Condensing Unit Installation and Operating Instructions

Heat Pumps. English. Models: M1, M2, M3, M4, M5. User Manual

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

MODEL URS-1: FACTORY RETROFIT PROGRAM

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

SERVICE NUMBER: SERV-351

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Warm Case Troubleshooting Guide 9/18/2014

OPERATING INSTRUCTIONS

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

SWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL

Service Step by Step Trouble-Shooting Check-List

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout

Otherwise, you can continue reading the file on the following pages.

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

CAUTION. No-Load Performance, Controls in Normal Position

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Owner s Manual for Swimming Pool Heat Pump

P MODEL AIR CONDITIONER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

OWNER S Manual PRINTED IN CANADA 10/2009

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Scotsman Technical Training. CU50 Cube Ice Machine

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

Service Manual. ETL Blast Chiller Series

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

How to Diagnose a TXV Failurek

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

CommStat 4 Controller

Installation Manual BCS 1000/1500

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Programmable Thermostat

Heat Pump Defrost Board Replacement Kit

User s Manual

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Condensing Unit Installation and Operating Instructions

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

User s Information and Installation Instructions

Installation Manual BCS2000/3000

User s Information and Installation Instructions

T-Series Air Conditioner T15 Model

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

2008 DOUBLE DRAWER UNDER COUNTER REFRIGERATOR / FREEZER PRODUCTS

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

SM/SV-Space Master Unit Coolers (E R.0)

Hoshizaki America, Inc.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

UHS Heater. How To Guide. HTG-UHS17a. Copyright 2017 Hayward Industries Inc.

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

Installation Instructions

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

Transcription:

G&F Manufacturing Service Manual Version 2.0 April 2010 Any tech working on these units must read this manual. Any questions, please call service department from the job site. 954-318-6900

Table of Content Topics Page Introduction to 410a 3 Sequence of operation 4 Control Board Operation 4 Control Board Service Menu 4 Service menu options 4 Language Select 4 Remote T-Stat 5 Pool Heat/Cool 5 Pool- Cool 5 Solar Control 5 Time Delay 5 Spa Timer 5 Even Heat 6 Temperature Scale 6 Defrost Mode 6 Evap Temp Calibration 6 Water Temperature Calibration 6 Load Defaults 6 Board Diagnostic 6 No Flow 6 Defrost 6 Low Refrigerant Pressure 7 Water Flow Lockout 7 Evaporator Sensor Malfunction 7 Water Sensor Malfunction 7 Components of Service 8 Charge 8 Thermal Expansion Valve 8 Compressor 8 Fan 8 Remove and Replace Parts 9 R&R Compressor 9 R&R TXV and/or Filter Dryer 10 R&R Heat Exchanger 10 R&R Water Temperature Sensor 10 R&R Defrost/ Evaporator Sensor 12 R&R Water Pressure Switch 12 R&R Hi/ Low Pressure Switch 12 R&R Control Board 12 Installation of Heat Pump 13 Direction Placement 13 Air Flow Direction 13 Electrical Diagram 14

Introduction This manual was put together to introduce you to G&F Manufacturing s new R-410A Swimming Pool Heat Pump. Please read the manual before you begin to service unit. If you have any questions, we have a dedicated service department to help you. Only put your refrigerant gauges on these units as a last resort. It is a package unit that has had many steps taken at the factory to assure the system is contaminant free. Almost all problems can be diagnosed without the use of gauges. Check to see that the unit is bonded and that the electric conduit is connected to the electrical box inside the unit. WARNING: Only certified service providers to work on unit. Anyone else will void warranty. WARNING: Turn off all electrical power to unit before servicing If you find that it is mis-plumbed, un-bonded, etc. contact the warranty department and let them handle it. Do not bad mouth an installation! Attention, Warning, and Caution boxes have been place through out this manual to help point out important information to look out for. Attention- Points out important information to be aware of Warning- Indicates an action that might void warranty Caution- Alerts service or user regarding safety issues. Page 3

Sequence of Operation In order to properly diagnose a problem you must understand the sequence of operation. When the pool pump comes on and the water flows through the heater, the water pressure closes the normally open pressure switch. When the switch closes, the control board then checks the thermostat to see if the pool water temp is below the board set point. If it is, it checks the normally closed high and low pressure switches. If both are closed it will then send 24v to the compressor/ fan contactor and the unit will start to heat or cool, depending on unit and mode. Note: There is a 5-minute delay on make timer built into the control board so it will have a delay before starting. Control Board Operation The control board has an LCD display and was kept as simple as possible for ease of customer use, to minimize nuisance-programming calls, and to be able to handle most scenarios found in the field. The board will display which mode it is in (Pool Heat, Spa Heat). Simply raise or lower temp by pushing the Up or Down arrows. To switch modes simply push the Mode button to toggle from pool to spa. For Pool Cool, there will be a Heat / Cool setting in the service menu. We also added Auto Feature so you may set temp at max temp and min temp, and board will automatically heat or cool the pool/spa. The board also has the capability to control your solar system. Control Board Hidden Menu All options and calibrations are in a hidden menu. To access the hidden menu press and hold both up and down arrows simultaneously until first option appears on display. The board will also rest to Pool/Spa heat screen after 20 seconds of no activity. Control Board Options Use Mode Button To Toggle Through Options 1 st Option: Language Select (English) (Options are: English, Spanish, French, Portuguese, German) Use arrows to toggle to selection, English is set as default. Page 4

You will find the Pool/Spa remote is no longer necessary; the board is programmed to automatically recognize the switch and self-program. 2 nd Option: Remote T- Stat (Disable) This option is used for external controller systems with its own thermostat such as an Aqua logic! or Aqua link!. Default is disabled. To enable, push Up or Down arrows until display says Enable. 3 rd Option: Pool Heat/Cool (Disable) Once this is enabled a Heat/ Cool setting will come up on display. The board will recognize when the temp of the pool has raise or dropped by 1 and will heat or cool the pool until it reaches set point again. (This option is only for Heat/Cool units.) 4 th Option: Pool Cool (Disable) Once this option is enabled, it will give you a pool cool mode on display, use Mode buttonto toggle (This option is only for Heat/Cool units.) 5 th Option: Solar Control (Disable) This option allows your pool heater (with additional wiring) to monitor the pool solar system s performance and will automatically control the temperature. 6 th Option: Time Delay (5) Default is 5 minutes. You may temporarily set to 0 for service purposes, unit will reset to 5 Mins after 10 Mins have passed. 7 th Option: Spa Timer (Continuous) This option is for rental properties or homeowners who do not want the spa left on indefinitely. Options are Continuous, Off, or Up to 20 hours in 15-minute increments. CAUTION: Off will not allow spa to run. Page 5

8 th Option: Even Heat (Disabled) Will periodically turn pool pump on according to delay setting. Options are: Off, 0 Hr (for testing), 1 Hr, 2 Hr, 3 Hr, 4 Hr, Default is off 9 th Option: Temperature scale (F) Sets display for Centigrade or Fahrenheit. Use arrows to toggle. 10 th Option: Defrost Mode (Air Defrost) Options are Air Defrost and Reverse Cycle. This option is set at the factory. 11 th Option: Evaporator Temperature Calibration For calibrating the defrost sensor located on the suction line. If this calibration is changed it will show by how much in plus or minus at bottom of display. 12 th Option: Water Temperature Calibration This option is for calibrating the water temperature sensor and will show the amount of calibration in plus or minus at the bottom of display. 13 th Option: Load Defaults In this mode you can reload all defaults by pressing the up arrow once. Board Diagnostics The control board will alert you to most problems. DISPLAY MESSAGES No Flow Means the water pressure switch is not closed. Check water flow to heater. Make sure any water bypass valves are not redirecting water around heater, filter is clean, pump is on, and water level in pool is up in the middle of the pool tile, this prevents skimmer from sucking air Defrosting Means the suction line has dropped to 28 degrees. It will shut the unit down until it reaches 40 degrees and the system will run again. Page 6

Low Refrigerant Pressure Low pressure cut out is 37 pounds cut in is 80 pounds. Unless the defrost sensor is way out of calibration, you should never see this code because of low ambient temperatures. You should only see this code if there is a refrigerant leak. Find and repair the leak. Water Flow Lockout High Refrigerant pressure is 540 cut in is 360. This error code is almost always a lack of water flow, so check everything under No Flow before putting on gauges or condemning High Pressure switch. Evaporator Sensor Malfunction This is a 10k sensor. If it is open or outside its range you ll get this error. Check connections before replacing. Water Sensor Malfunction This is also a 10k sensor. If it is open or outside of its range you ll get this error. Check connections before replacing. This is a standard refrigeration system and most diagnostics are the same as air conditioners. However, you must keep in mind that the Heat Exchanger is the condenser and the large air coil around unit is the evaporator. The system consists of a compressor, water-cooled condenser, TXV, and air heated evaporator. Diagnosing the refrigeration system is something all A/C technicians should know. However, there are a few points we would like to point out. Page 7

Charge The system holds 4 pounds for Turbotec R-410A unit, because the sub cooling & super heat vary greatly with air and water temperature. For field charging we use a condensing temperature of 24 degrees. After power is on and water has been running through unit for at least 5 minutes your high side temperature should be 24 degrees above water temperature. Read on control board. Unless the ambient temperature is less than 62 degrees, we expect a superheat of at least 15 degrees. You may read the suction line temperature by pushing and holding the Up arrow on control board. After about 15 seconds, the board will display suction line temperature, the board will read Evap and a temp. Please wait for at least 10 minutes run time before checking superheat. TXV (Thermal Expansion Valve) All units are manufactured with adjustable TXV s. If you suspect the TXV needs to be adjusted, please call 954-318-6900 from the jobsite and technical support will walk through it with you. Check temperature on both sides of filter. If more than 2 degrees different the filter is clogged. Compressor Broken valves, shafts, (not pumping) and shorted to ground are obvious problems. However, no starts are commonly misdiagnosed. Check the capacitor for correct MFD s. Check connections, voltage and open windings. If open windings, check to see if compressor is hot. If so, let it cool down, or run cool water over it before condemning. Check Ohm s: common to run and common to start should equal run to start. If everything above is correct, then add hard start to capacitor. Fan Please check connections and capacitor before condemning fan motor. If you do have to change fan motor ALWAYS change capacitor also. Page 8

Although the components of this system are the product of an engineer, the design of the unit was created by a service technician of 35 years. Therefore, wherever possible, the unit was put together with ease of service in mind. Time is important to both your company and ours so when replacing refrigerant components please start with recovering refrigerant, and then move on to disconnecting component. Remove and Replace Parts R&R Compressor Turn power to unit off. Start recovery of refrigerant. Remove the 4 screws holding the top on unit. Cut wire tie on fan wire bundle outside of the control box. Lift top of unit, flip over and stand on end next to unit. Bleed run capacitor. Remove wires from compressor (Note: colors and positions) Unbolt compressor from base. Remove TXV bulb from suction line. When recovery is done cut out filter. Unsolder compressor and move through top. Solder in new Filter/ Dryer. Solder in compressor. Pressurize system and check for leaks. Start evacuation. Rebolt compressor to base. Rewire compressor and reinstall wire cover. Reinstall TXV bulb. Put top back on unit and rescreen. Change Capacitor once system has reached 500 microns of vacuum then charge system to. Turn power back on and check unit operation. Reinstall front cover. Page

R&R TXV and/ or Filter Turn off power. Start refrigerant recovery. Remove 4 screws holding top on unit. Cut wire tie holding fan wires bundled at side of control box. Lift top off, flip over and lay on end next to unit. After recovery has finished remove component from system. Replace with new filter/ dryer. Solder in new component. Leak check, start vacuum. Replace top on unit. After vacuum has reached 500 microns, charge system to 4 lbs of R-410A for Turbotec Titanium unit, Start unit and check operation. Replace front cover. R&R Heat Exchanger Turn off power. Start recovery of refrigerant. Cut wire tie holding fan wires bundled next to control box. Remove 4 screws holding top on unit. Lift top off, flip top over and lay on end next to unit. Cut or break female half of unions off back of unit. Cut wire ties holding PVC ells to bottom of base. When recovery is complete cut refrigerant filter out. Unsolder and remove heat exchanger through top of unit. Set new heat exchanger in base of unit. Solder in heat exchanger. Start system on vacuum. Rebolt heat exchanger to base. Always cut the filter out, DO NOT UNBRAZE. Restrap PVC ells to bottom of unit and glue on new female half of unions. Reinstall top. After system has reached 500 microns of vacuum, charge system to 4 pounds R-410A. Turn power on, check system operation, and reinstall front cover. Page 10

WARNING: DO NOT Cut old WTS wire and splice in new WTS R&R Water Temp Sensor Turn off power. Remove front cover. Unscrew water temp sensor (WTS) and take out. Screw in new WTS. Take old WTS spade clips off of the back of the board. Place new spade clip in same slot. Close HP up. The water temp probe is located on the lower water inlet elbow and is unserviceable. Therefore when it s necessary to replace probe, drill a 3/8 hole in upper elbow and install new probe there. After it s installed, wrap it once with cork tape then with closed cell insulation, then again with cork tape. R&R Fan Motor Turn off power. Remove front cover. Disconnect fan wires from contactor, capacitor and ground. Remove strain relief bushing and holding wires where they penetrate control box. Feed wires out of control box. Cut wire ties holding wires in a bundle. Remove plastic fan motor cap from fan guard. Remove 4 screws holding top on unit and remove top. Flip top over and lay on ground or on level surface. Loosen setscrew and then remove fan blade. Lift one side of top up to a 45 degree angle and remove 4 nuts holding fan motor to fan guard. Lay top back down and remove motor. Reverse procedure to install new motor. Be sure to reinstall strain relief bushing where wires penetrate control box and replace fan motor capacitor. Page 11

R&R Defrost Sensor Turn off power. Remove front cover. Disconnect connectors from T-7 and T-8 on control board. Remove strain relief bushing where wires penetrate side of control box and feed sensor wires out of control box. On the suction line cut the cork tape and peel back exposing TXV bulb and strap. Loosen strap and slide old sensor out. Reverse procedure to reinstall being sure to reinsulate and reinstall strain relief bushing. R&R Water Pressure Switch Turn off power. Turn off water. Remove front cover. Remove wires from pressure switch. Remove 2 screws holding control box back to coil on right side of control box. Bend control box enough to get to back of flow switch. Cut tubing as close to flow switch as possible. Remove 1/2 nut holding flow switch to control box. Install new switch and reverse procedure. R&R High or Low Pressure Switch Turn off power. Remove front cover. Cut high-pressure switch wires near switch. Unscrew HP switch using back up wrench. Use leak lock when reinstalling switch. Remove strain relief bushing where wires penetrate control box. Feed old HP switch wires out and new HP switch wires in. Reinstall strain relief bushing. Install spades at HP terminals on control board. Start and check unit operation. Reinstall front cover. R&R Control Board Turn off power. Remove front cover. Loosen 4 screws holding control board to cover. Remove control board and let hang on wires. Push 4 screws through board and install new board. Remove wires from old board and install on new board one at a time, being sure to place wires from same terminals from old board to new board as you are taking them off. Turn power on. Start unit, check operation, and reinstall front cover. Page 12

Installation Before installing this heater there are several things to consider for performance, serviceability and warranty. Direction of Placement: Access panel should always face out away from wall. If you must face the service panel toward the wall, leave a minimum of 24 between the wall and the unit. You will not have a happy customer if they have to squeeze between the wall and the heater to use the controller. Placement: Airflow is critical to the performance and efficiency of a heater, therefore leave as much space around and above heater as possible. Installations under palm trees, inside screened porches etc. may help hide unit but will drastically reduce the performance of the unit. You will not have a happy customer. The unions were to the side of the unit to keep pipes out of the way of the control panel so that they are not stepped on while adjusting controls or WARNING: Do not plumb the pipes back around front where pipes will be stepped on, or prohibit access to the front panel. Make sure unit is bonded and conduit is connected all the way up to the control box. For a more detailed installation manual, please visit our website Gulfstreamheatpump.com, and the manual will be there for you to download. If no internet access, call service department 954-318-6900 and we will fax or mail a copy to you. Page 13

Page 14

Bill of Materials DRAWING NO. COMPONENT DESCRIPTION PART NO. 1 COMPRESSOR PLUG 1001001 2 FAN MOTOR, 2/5HP, 825 RPM 1001002 3 CONTROL 1001003 4 TEMP SENSOR, SUCTION 1001004 5 TEMP SENSOR, WATER 1001005 6 CONTACTOR, 2 POLE, 40A 1001006 7 TRANSFORMER, 40VA 1001007 8 CAPACITOR, 80UF, 370V 1001028 9 CAPACITOR, 7.5UF, 370V 1001009 10 PRESSURE SWITCH, HIGH, 540 1001054 11 PRESSURE SWITCH, LOW, 37 1001055 12 WATER PRESSURE SWITCH 1001012 13 TOP COVER 3003014 14 BASE PAN 3003013 15 FRONT PANEL 3003015 16 TOP CAP 3003033 17 ELECTRICAL BOX 3003017 18 FAN BLADE, 3P24CCW36 6006001 19 FAN GUARD 6006008 20 EVAP GUARD, 32 X 86 6006009 21 2" S-S UNION #200-100 7007023 22 EVAPORATOR, 32 X 84 8008078 23 FILTER/DRIER 8008052 24 TXV 8008081 25 CONDENSER, TI 8008084 26 COMPRESSOR, HLH061T1LP6 8008098 Page 15

10K Sensor Ohms Chart F OHM F OHM F OHM F OHM F OHM 20 46225 40 26100 60 15310 80 9297 100 5827 21 44879 41 25391 61 14921 81 9076 101 5697 22 43577 42 24704 62 14543 82 8861 102 5570 23 42318 43 24037 63 14176 83 8651 103 5446 24 41099 44 23391 64 13820 84 8447 104 5326 25 39919 45 22764 65 13473 85 8249 105 5208 26 38777 46 22156 66 13136 86 8056 106 5094 27 37671 47 21566 67 1209 87 7867 107 4982 28 36601 48 20993 68 12491 88 7684 108 4873 29 35565 49 20438 69 12182 89 7506 109 4767 30 34561 50 19900 70 11882 90 7333 110 4664 31 33590 51 19377 71 11589 91 7164 111 4563 32 32648 52 18870 72 11305 92 6999 112 4464 33 31737 53 18377 73 11029 93 6839 113 4368 34 30853 54 17899 74 10761 94 6683 114 4274 35 29998 55 17435 75 10500 95 6530 115 4183 36 29169 56 16985 76 10246 96 6382 116 4094 37 28365 57 16548 77 9999 97 6238 117 4007 38 27587 58 16123 78 9758 98 6097 118 3922 39 26832 59 15711 79 9525 99 5960 119 3839 Page 16

WARNING: Using any company that is not certified by G&F Manufacturing will cause the warranty on the unit to void. SERVICE All service must be handled by an Authorized Service Center. Warranty may be void if a nonauthorized service representative does service. Do not return the heater to your dealer, as they do not provide service. Before calling for assistance or service, please check the Troubleshooting section of this manual or call your dealer. This may save you the cost of a service call. If you still need help, follow the instructions below.!"#$%&"'&()'*"'+*,(%)"-'*.'&(//%)0'12'(,3''45678'9:;<=5>>' When asking for help or service please provide a detailed description of the problem, your heater s complete serial number, the purchase date and dealer purchased from. This information will help us respond properly to your request. Keep a copy of the sales receipt showing the date of purchase. Proof of purchase will assure you of in-warranty service. MANUFACTURED BY: G & F MANUFACTURING, INC. 7902 INTERSTATE COURT NORTH FORT MYERS, FL 33917 Page 17