DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

Similar documents
Design and Application Details

NMC Nozzle Mix Gas/Oil Combination Burners

INDITHERM. Low temperature gas burners

FLAME DETECTOR ADAPTERS 8832 through 8839 and Series R Bulletin 8832

North American Flame Detector Adapters 8832 through 8839 and Series R

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Eclipse AirHeat Burners

PBG PACKAGED GAS BURNER

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Eclipse AirHeat Burner

ECLIPSE INFORMATION GUIDE

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Power Flame Incorporated

INDITHERM. Low temperature gas burners

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Specifications of MULTIFIRE burners

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

SECTION HEATING BOILERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

ECLIPSE INFORMATION GUIDE

NMG NOZZLE MIX GAS BURNERS

PACKAGED COMMERCIAL WATERTUBE BOILERS

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

FXLF-9. High Efficiency Water Heaters and Boilers

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

PROFIRE -E SERIES BURNERS

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Direct Fired Heater Model AD Specification

Steam Fundamentals. (in heating & processing applications)

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

SERIES 19A. mith PRESSURIZED WET BASE

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Power Flame Incorporated

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

Installation Instructions

HAUCK STARJET BURNER SJ075 SJ980

Domestic Hot Water Heaters and Boilers FTIIIC-6

Power Flame Incorporated CMAX. Installation and Operation Manual

Revitalize Building Mechanical Systems (4619)

OPERATING AND MAINTENANCE MANUAL

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

STR-Series Indirect-Fired Air Turnover Units

Type CG Series Forced Draft Gas Burner

PACKAGED METALLIC BURNERS

MODEL CEW OHIO SPECIAL

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

A. Product Data: Include rated capacities, furnished specialties and accessories.

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Power Flame Incorporated

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Distributed By: M&M Control Service, INC

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Indirect gas-fired air heater

Model 601CRD Oil Burner

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Eclipse RatioMatic Burners

Specifications of V-Line burners

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Model CB-LE. Packaged Boiler HP. Operation, Service, and Parts Manual /09. and Model CB Ohio Special HP

Distributed By: M&M Control Service, Inc Building Technologies

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

MERIT SERIES Downflow

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Guidelines for Preparing for a Temporary Steam Plant

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

Eclipse Self-Check UV Scanner

SECTION PLUMBING EQUIPMENT

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

U n i t H e at e r s

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

DIVISION FINNED WATER-TUBE WATER HEATERS

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

DIVISION FINNED WATER-TUBE WATER HEATERS

SUBMITTAL SCHEDULE & DATA

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

Zeeco recently had the opportunity

Zeeco, Inc. Doc. No Tulsa, Ok Cover Page GLSF-14 Free-Jet and RWSF-4 Radiant Wall Burners. Range Fuels Soperton Plant, LLC

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Transcription:

INTEGRAL FAN BURNERS 43, 53, 63 Supplement 600- July 996 DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS Integral Fan (and) Shutter Section (hinged for quick access to internals) Combustion Air Interlock Observation Port with UV Flame Detector Mounting Body and Gas Section (Stationary) Mounting Plate and Tile Assembly Oil Atomizer Assembly Blower Motor Ignition Transformer Modulating Gas Butterfly Valve Pilot Solenoid Gas Valves Control Motor Air and Fuel Control Linkage (far side) Oil Solenoid Valves Modulating Sensitrol Oil Valve (far side) Sealtite Conduit Features of NORTH AMERICAN Integral Fan Burners BUILT-IN FAN: Delivers 00% of combustion air required for burner operation. Eliminates need to install an expensive and bulky air delivery system. Avoids dependency of several burners on one blower. CONTROL VARIETY: Building from the basic burner package, two ratio control systems are available along with many pre-packaged gas and oil trains, motorized controls, flame safeguard accessories, and programming systems. WIDE RANGE OF CAPACITIES: 3 000 000 to 30 000 000 Btu/hr, in seven sizes. Typical air turndown is 4: on standard models. Greater turndowns are available for special applications. RUGGED, VERSATILE, AND RELIABLE: An ultra stable burner designed to operate with 20% excess air in chambers at temperatures up to 2000 F and under negative or slightly positive pressures. Cold, tight chambers present no problem for this rugged, low-maintenance workhorse. Proven reliability while operating with natural gas, any grade of commercial fuel oil, crude oil, pitch, or refinery bottoms.

NORTH AMERICAN Mfg. Co. Cleveland, OH 4405-5600 USA Supplement 600-, 7-96 Page 2 BURNER DESIGNATION? CAPACITIES @ CHARACTERISTICS BLOWER Table. Main air, Natural Oil, Flame Size, Burner Data Btu/hr scfh gas, scfha gpha length hp rpm 43A 4 200 000 50 000 4 200 2.5' 5'.5 3450 53A- 2 4 200 000 50 000 30.3 2.5' 5'.5 3450 63A- 5,6 4 200 000 50 000 4 200 27.9 2.5' 5'.5 3450 CR 4 200 000 50 000 4 200 27.9 2.5' 5'.5 3450 43B 6 300 000 76 000 6 300 3' 7' 3 3450 53B- 2 6 300 000 76 000 50.7 3' 7' 3 3450 63B- 5,6 6 300 000 76 000 6 300 42.0 3' 7' 3 3450 CR 6 300 000 76 000 6 300 42.0 3' 7' 3 3450 53CL- 4 0 500 000 26 000 78 3.5' ' 5 750 63CL- 5,6 0 500 000 26 000 0 500 70 3.5' ' 5 750 43C B 2 300 000 4 000 2 300 3.5' 2' 5 3450 53C- 2B 2 300 000 4 000 9 3.5' 2' 5 3450 63C- 5,6 8 400 000 05 000 8 400 55.8 3.5' 2' 5 3450 43CS C 8 400 000 05 000 8 400 3.5' 2' 7.5 3450 53CS- 2C 8 400 000 05 000 55.8 3.5' 2' 7.5 3450 63CS- 2C 8 400 000 05 000 8 400 55.8 3.5' 2' 7.5 3450 43D 8 000 000 26 000 8 000 4' 2' 7.5 750 53D- 2 8 000 000 26 000 3 4' 2' 7.5 750 63D- 5,6 6 800 000 200 000 6 800 2 4' 2' 7.5 750 43E 25 200 000 300 000 25 200 4' 2' 0 750 53E- 2 25 200 000 300 000 82 4' 2' 0 750 63E- 5,6 25 200 000 300 000 25 200 67 4' 2' 0 750 CR 25 200 000 300 000 25 200 67 4' 2' 0 750 43FA 30 000 000 360 000 30 000 4' 8' 20 3450 53FA- 2 30 000 000 360 000 222 4' 8' 20 3450 63FA- 5,6 30 000 000 360 000 30 000 200 4' 8' 20 3450 CR 30 000 000 360 000 30 000 200 4' 8' 20 3450?Burner model number breakdown is as follows: First digit identifies burner as 4 = gas only 5 = oil only 6 = dual-fuel Next 3 digits, 3, identify burner as part of integral fan series Letters designate burner frame size Numerals or CR after hyphen show fuel selection 2 = #2 or #4 oil 5 = #5 oil 6 = #6 CR = crude oil @Capacities and flame lengths are with 20% excess air and.5"wc backpressure in a cold, tight chamber. Excess air operation at rates greater than 20%, through reduction of fuel input, is possible for nearly all of these burners. Consult factory for maximum excess air rate for any particular size and fuel. AFuel rates are based on the following calorific values: 000 Btu/cu ft of natural gas 35 000 Btu/gallon of light (#2 or #4) oil 50 000 Btu/gallon of heavy (#5 or #6) oil 45 000 Btu/gallon of crude oil BCapacity is with 5% excess air and 0.5"wc backpressure. CCapacity is with 20% excess air and 5"wc backpressure. Sand Dryer Heater Treater

NORTH AMERICAN Mfg. Co. Cleveland, OH 4405-5600 USA Supplement 600-, 7-96 Page 3 APPLICATIONS Process Heaters Water Heaters Liquid Asphalt Heaters Aluminum Melters Steam Generators Core Dryers Boilers Incinerators Emulsion Treaters Paint Dryers Vaporizers Air Heaters Direct-Fired Oil Heaters Ceramic Dryers Dross Reclaiming Furnaces Rotary Dryers for Ore, Sand, or Aggregate SPECIFICATIONS Integral fans provide 00% combustion air to these nozzle-mix burners. Oil atomizers are of the tip emulsion design, using steam or compressed air as the atomizing medium. Oil must be delivered to the nozzle at viscosities below 00 SSU. The ruggedly constructed burners consist of three basic sections. Front Section. A heavy cast iron mounting plate, with slotted mounting holes, fitted with a high strength castable burner tile rated for service up to 2600 F. A carbon steel or 304 stainless steel tile support jacket is available as an option. Center Section. A circular gas plenum with bottom gas inlet, a combustion air diffuser, a connection for a spark-ignited premix gas pilot (for natural gas or propane), and a threaded boss to accommodate a flame rod. Rear Section. Hinge-mounted includes blower motor, impeller, intake guard, a large reinforced glass observation port, provisions for mounting a flame detector, the flange-mounted oil atomizer, and the manual or motorized firing rate control. An accurate linked valve ratio control is provided by a compact arrangement of linkage rods and swivels that connect the internal main air proportioning shutters with a butterfly gas valve and/or a Sensitrol Oil Valve. Fuel oil enters the Sensitrol Oil Valve via a swivel type joint mounted on the hinge. Basic Gas Burner consists of the above three sections fitted with a manually positioned and lockable firing rate control lever (shown in burner photo) and a butterfly gas valve with linkage assembly. Refer to Bulletin 640 for main and pilot gas accessories. Basic Light Oil Burner consists of the three basic sections described above, with the following equipment: a manually positioned and lockable firing rate control lever, a Sensitrol Oil Valve with linkage assembly, and a flange mounted oil atomizer assembly. Refer to Table 2 for oil and atomizing medium pressure/flow requirements. Specify this burner arrangement for oils up to and including #4 grade. Basic Heavy Oil Burner is similar to the light oil burner except atomizer, Sensitrol Oil Valve, and oil piping are sized and arranged to accommodate heavy oil or crude oil. Oil temperature is maintained electrically within the burner through four low wattage cartridge heaters: one within Sensitrol valve body, two in heater blocks attached to oil tube, and one in a heater block attached to the nozzle. The hinge assembly is fitted with a hot oil return valve (shown in the photograph). This burner is recommended for all heavy oils, including blended grades. Basic Dual-Fuel Burner is similar to oil burner except provision is made for burning either gas or a pre-selected grade of oil. A dual-fuel burner fitted for heavy oil permits use of any grade, ranging from diesel through very heavy #6. Flame Supervision and Control. There is a long list of optional accessories that can be added to the basic burners described above. In many applications of this burner, the combustion chamber is below 400 F. Electronic flame supervisory systems are strongly recommended. Such systems are offered by North American and others. A specially designed system is available for boilers. Your local North American sales engineer can help select burner accessories required to make a firing system that will be reliable, efficient, and safe to operate. Flue Gas 2000 F Aluminum Dross Cooking Oil Heater Aluminum Dross Reclaiming Furnace

NORTH AMERICAN Mfg. Co. Cleveland, OH 4405-5600 USA Supplement 600-, 7-96 Page 4 Pathological Incinerator Liquid Asphalt Heaters Table 2. Flows and Atomizing Mediums@ Oil PressuresA Minimum Gas Pressures Req'd Comp. air flow, Steam flow, Light oil, Heavy oil, Gas PressuresB Metering at Burners scfm lb/hr psig psig "wc Valve SizeC Burner Size Designation? A 4 30 20 70 2.2 3" B 4 50 90 65 3. 3" CL (heavy oil) 8 70 80 2.8 4" C (light oil) 4 9 85 2.2 4" C (heavy oil) 7 30 70 2.2 4" CS (light oil) 6 0 25 4.0 4" D 6 30 50 60 4.0 6" E (light oil) 4 82 55 3.0 8" E (heavy oil) 28 68 70 3.0 8" FA 28 200 75 90 6.0 8"?Letters designate frame size see Table, page 2. @Oil and dual-fuel burners require an accessory package for the atomizing medium. Pressures required at the inlet of that package are 75-00 psi for air and 50-25 psi for steam. AOil and dual-fuel burners require oil delivered to burner hinge at a viscosity below 00 SSU and at pressures listed above. If a liquid fuel other than commercial fuel oil is to be used, consult North American for recommendations of pressure and flow requirements. BGas burners are intended for use with natural gas or propane. Listed pressures are for natural gas consult North American for propane pressures. Pressures listed are for system sizing only. They are not for ratio adjustment. CGas piping upstream of burner gas metering butterfly valve to be same size as the metering valve for a minimum of 0 pipe diameters. Place reducer, if used, as close as possible to the gas regulator. Printed in USA WARNING: Situations dangerous to personnel and property can develop from incorrect operation of combustion equipment. North American urges compliance with National Safety Standards and Insurance Underwriters recommendations, and care in operation. North American Mfg. Co., 4455 East 7st Street, Cleveland, OH 4405-5600 USA, Phone 26-27-6000, Facsimile 26-64-7852 E-mail sales@namfg.com www.namfg.com NA700-Suppl600-

CAPACITIES million Btu/hr DIMENSIONS inches Frame gas and light oil heavy oil A 3.4 to 4.2 2.5 to 4.2 B 5.2 to 6.3 5.2 to 6.3 C 8.4 to 2.3 8.4 CS 8.4 4 Lifting eye Combustion air switch Silencer 45 4/5/63-A, B, C, and CS FRAME SIZE BURNERS Air Inlet controller J K DD EE Ignition transformer L swing radius Pilot Pilot regulator Pilot solenoid valve Control motor with low fire Observation port start switch UV detector 8 slots for U- bolts equally spaced on W-BC Q P 9 Hinge switch 3 N Blower Business Group 4/5/63 BURNERS Engineering Dimensions 63 Prewired burner junction box R, R 2 Stainless tile jacket F, F 2 E ƒ E 2 ƒ G February 998 Est. Shipping Weightsˆ Frame lb A 400 B 500 C 700 CS 800 2 Y H BB AA S T 3 /8 fpt Oil inlet Z Blower housing Blower motor /2 fpt Pilot gas M min. floor clearance CC A pipe size Gas inlet X D C B FF, FF2 Air motor 3 Series with high and low switches Burner Frame Size 43-, 53-, 63- A B C D Eƒ E2ƒ F F2 G H J K L M N P Q A 3 36 3 /4 25 3 /4 6 6 3 /4 3 /2 3 /2 20 3 /4 0 3 /4 4 /4 3 /4 23 /2 22 /2 2 6 5 /6 6 B 3 4 3 /8 29 5 /8 3 /4 6 6 3 /4 /2 3 /2 20 3 /4 0 3 /4 4 /2 3 7 /8 27 /8 25 /2 2 6 5 /6 6 C 4 46 /8 33 /8 3 9 /2 20 /4 4 6 3 /8 24 4 /2 4 3 /4 6 /4 29 26 /2 23 6 3 /6 CS 4 53 40 3 9 /2 20 /4 4 6 3 /8 24 4 /2 2 /4 20 38 26 /2 23 6 3 /6 3 Series Burner Frame Size 43-, 53-, 63- R R2 S T U W X Y Z AA BB CC DD EE FF FF2 A 20 /2 24 0 3 /8 5 3 /4 B 20 /2 24 0 3 /8 5 3 /4 C 28 3 /2 2 6 /4 CS 28 3 /2 2 6 /4 /2 9 /2 4 /4 8 6 3 /4 3 3 /4 5 /8 5 7 /8 5 /6 2 3 /4 29 /4 27 3 /4 /2 9 /2 4 /4 8 6 3 /4 8 /8 6 3 /4 7 /2 7 /4 2 3 /6 29 /4 24 /4 5 /8 22 3 /4 5 3 /4 9 /4 8 7 /4 4 7 /8 7 3 /8 7 /4 5 /2 29 3 /4 24 3 /4 5 /8 22 3 /4 5 3 /4 9 /4 8 2 6 3 /8 9 /8 7 /4 5 29 3 /4 24 3 /4 ANSI 25 lb flanged connection. Not used on 52 or 53 Burners. Honeywell M9484 or M7284 motors shown. For other motor types, check with North American. ƒ Furnace opening for 3-A, B, and equivalent size 2 burners is 6 /2" (7 /2" with jacketed tile). Furnace opening for 3-C, CS, and equivalent size 2 burners is 20 /2" (2" with jacketed tile). With stainless steel tile jacket only. If one pilot solenoid valve is used, dimension R applies. Use dimension R 2 for burners with two pilot solenoid valves. Optional, furnished only when ordered. If Moore Positioner is used, dimension FF applies. Use dimension FF 2 if the Moore Positioner is not supplied. ˆ If air motor is used, add 50 lb to these figures. If burner is gas and/or light oil, dimension F applies. Use dimension F 2 if burner is heavy oil.

CAPACITIES million Btu/hr Frame gas and light oil heavy oil D 2.6 to 8.0 2.6 to 6.8 E 2.0 to 25.2 2.0 to 25.2 FA 29.4 to 30.0 29.4 to 30.0 FC 29.4 to 30.0 29.4 to 30.0 Lifting eye Combustion air switch 4 2 Silencer Y /2 fpt Oil inlet 4/5/63-D, E, FA, and FC FRAME SIZE BURNERS P DIMENSIONS 9 Prewired burner junction box inches K Air Inlet controller Z Blower housing 45 DD EE L swing radius 3 Series Burner Frame Size 43-, 53-, 63- A B C D Eƒ E2ƒ F G H J K L M N P Q Pilot Pilot regulator Pilot solenoid valve /2 fpt Pilot gas Control motor with low fire Observation port start switch UV detector 8 slots for U- bolts equally spaced on W-BC M min. floor clearance J H Blower motor BB AA CC Q A pipe size Gas inlet C B Hinge switch X T D S N G R, R 2 Ignition transformer FF Est. Shipping Weightsˆ Frame lb D 950 Stainless E 250 tile jacket FA 600 FC 700 F E ƒ E 2 ƒ GG, GG 2 Air motor with high and low switches D 6 62 7 /8 49 /8 3 3 /4 23 23 3 /4 7 28 4 /2 7 3 /4 20 37 /6 33 /2 25 2 3 /4 9 /6 E 8 64 /4 5 3 /4 23 23 3 /4 8 32 /4 6 /2 20 3 /8 20 4 38 26 3 /4 4 /8 /8 FA 8 68 3 /4 55 3 /4 23 23 3 /4 8 32 /4 6 /2 23 /8 23 3 /4 49 38 26 3 /4 4 /8 /8 FC* 8 74 6 3 /4 23 23 3 /4 8 32 /4 6 /2 27 23 3 /4 5 38 26 3 /4 4 /8 /8 3 Series Burner Frame Size 43-, 53-, 63- R R2 S T U W X Y Z AA BB CC DD EE FF GG GG2 D 29 3 /4 33 /4 4 5 5 /6 E 3 /2 35 /2 6 /8 8 /4 FA 3 /2 35 /2 6 /8 8 /4 FC* 3 /2 35 /2 6 /8 8 /4 5 /8 26 3 /8 7 /4 3 /2 0 28 /4 8 5 /8 2 3 /4 0 3 /4 5 /8 7 38 3 /4 33 3 /4 7 /8 30 8 3 /8 5 /2 2 29 /2 8 2 7 /8 0 3 /4 6 /4 7 /2 35 30 7 /8 30 8 3 /8 5 /2 2 36 3 5 9 3 /4 3 /6 7 /2 35 30 7 /8 30 8 3 /8 5 /2 2 37 3 /4 6 9 3 /4 2 7 /6 7 /2 35 30 * 50 hertz only. ANSI 25 lb flanged connection. Not used on 53 Burners. Honeywell M9484 or M7284 motors shown. For other motor types, check with North American. ƒ Furnace opening for 3-D, E, FA, and FC Burners is 23 /2" (24 /2" with jacketed tile). With stainless steel tile jacket only. If one pilot solenoid valve is used, dimension R applies. Use dimension R 2 for burners with two pilot solenoid valves. Optional, furnished only when ordered. If Moore Positioner is used, dimension GG applies. Use dimension GG 2 if the Moore Positioner is not supplied. ˆ If air motor is used, add 50 lb to these figures. FA and FC burner shutter assembly with blower assembly removed swing radius = 2 5 /6". DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM NORTH AMERICAN MFG. CO. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL. WARNING: Situations dangerous to personnel and property can develop from incorrect operation of combustion equipment. North American urges compliance with National Safety Standards and Insurance Underwriters recommendations, and care in operation. North American Mfg. Co., 4455 East 7st Street, Cleveland, OH 4405-5600 USA, Phone 26-27-6000, Facsimile 26-64-7852 Printed in USA AGS298-ED63-6000

Blower Business Group 43, 53, 63 PACKAGED AUTOMATIC BURNERS Engineering Specifications 63 May 994 Features of NORTH AMERICAN Packaged Automatic Burners BUILT-IN BLOWER: Delivers 00% of combustion air required for burner operation. Eliminates need to install an expensive and bulky air delivery system. CONTROL VARIETY: Building from the basic burner package, control systems are available along with many pre-packaged gas and oil trains, motorized controls, flame safeguard accessories, and programming systems. WIDE RANGE OF CAPACITIES: 2 500 000 to 30 000 000 Btu/hr, in six frame sizes. Typical air turndown is 4: on standard models. Greater turndowns are available for special applications. RUGGED, VERSATILE, AND RELIABLE: An ultra stable burner designed to operate in chambers at temperatures up to 2000 F and under negative or slightly positive pressures. Cold, tight chambers present no problem for this rugged, lowmaintenance workhorse. Proven reliability while operating with natural gas, #2 fuel oil, and #6 fuel oil. Crude oil, and pitch have also been successful, however, these are often application dependent. Consult North American Mfg., Cleveland, for applications with these fuels.

NORTH AMERICAN Mfg. Co. Engineering Specifications 63, 5-94 Cleveland, OH 4405-5600 USA Page 2 The Packaged Automatic Burners are ideal for steel firebox, scotch marine, cast iron sectional, and watertube boilers, and industrial process heating equipment, such as air heaters, dryers, oil heaters, ovens, and incinerators. Six frame sizes produce a wide range or capacities (2 500 000 to 30 000 000 Btu/hr). Design: The 43 Burner is for any fuel gas; the 53 for fuel oils, and the 63 for dual-fuel (combination gas and oil). All are of the nozzle mix design with an integral blower to supply 00% combustion air. Oil atomizers are of the tip emulsion design, using steam or compressed air as the atomizing medium. The hinged construction provides quick and complete accessibility. Fixed fuel lines need not be broken for service because fuel oil enters through the burner hinge and gas enters through a stationary gas section. Construction: This rugged burner consists of a cast iron mounting plate, with slotted mounting holes, fitted with a high strength case refractory burner tile rated for service up to 2600 F. A stainless steel tile support jacket is available as an option. The grade of stainless steel is application dependent. The circular gas plenum has a bottom gas inlet, a combustion air diffuser, and a spark-ignited premix gas pilot (for natural gas or propane). The hinge-mounted blower section includes the blower motor, impeller, intake guard (or optional intake silencer), a large reinforced glass observation port, provisions for mounting a flame detector, and flange mounted oil atomizer. An accurate linked valve ratio control is provided by a compact arrangement of aircraft-quality linkage rods and swivels that connect the internal main air proportioning shutters with a butterfly gas valve and/or a Sensitrol oil valve and the modulation motor. Standard Components: The 4/5/63 Burner includes the pilot gas regulator, pilot gas solenoid (2nd solenoid optional), 6000 volt ignition transformer, electric modulating control motor (air motor optional), low combustion air interlock, and burner hinge interlock switch. Oil burners also include a solenoid valve (or optional motorized automatic valve), piped between the hinge and atomizer assembly. All electrical components are wired to the burner mounted NEMA 4 junction box. Turndown: Typical air turndown is 4: on standard models. Greater turndown can be achieved with an optional blower air inlet controller. Consult North American, Cleveland, for details. Excess Air: Standard burner linkage is factory set to deliver 20% excess air. Rates greater than 20% are possible through reduction of fuel input. Flame Characteristics: These burners generate welldefined medium length flames. See Supplement 63- for flame sizes. Chamber Pressures: Designed for stable operation in chambers with pressures ranging from 0.5"wc to 2.0"wc. The "N" burner is specified on applications with 0 to 0.5"wc chambers (i.e., 2-pass boilers, dryers, heaters, etc.) and the "P" burner is specified on those with 0. to 2.0"wc chambers (i.e., 3-pass boilers, etc.). Consult North American, Cleveland, for burner performance with other pressures. Underwriters Laboratories Listing: The Model 4/5/63 Burners have been designed in accordance with the requirements of the Underwriters Laboratories. Consult North American Mfg., Cleveland, for labeling service. Hinged construction provides for complete accessibility to burner internals. WARNING: Situations dangerous to personnel and property can develop from incorrect operation of combustion equipment. North American urges compliance with National Safety Standards and Insurance Underwriters recommendations, and care in operation. Printed in USA AGS797-ES63-6000