Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Similar documents
Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Technical Bulletin 005(B) Developed with Building Standards Scotland

Building Regulations Approved Document F1 Means of Ventilation April 2006

A6VS VENTILATION STANDARDS

Introduction. General. Other regulations. British Standards and European Technical Specifications

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

RENTED DWELLING REGULATIONS

NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Third Edition. Prepared by the Department of Building and Housing

Verification Methods For New Zealand Building Code Clause G4 Ventilation

VENTILATION DESIGNED FOR CARE HOMES

ONLINE VERSION ONLINE VERSION

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

HOUSING (STANDARDS FOR RENTED HOUSES) REGULATIONS 2017

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

i PSV WHOLE-HOUSE VENTILATION SYSTEM

Ventilation for New Low-Rise Residential Buildings July 20, 2015

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Permanent Ventilators (for the Supply of Combustion Air)

Energy Efficiency Standards

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

NUAIRE POSITIVE INPUT VENTILATION SYSTEMS DRIMASTER-ECO LOFT MOUNTED POSITIVE INPUT VENTILATION SYSTEMS

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide

A GUIDE TO SELECTING THE RIGHT FAN

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

Building Regulations 2010: What it means to you.

Description of the property and water systems:

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

SFA Guide to Building Regulations and Solid Fuel Heating

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Quick Reference Guide to Cabinet types

Building Regulations Update. by Eamonn Smyth

SECTION 915 CARBON MONOXIDE DETECTION

Approved. Document. Sanitation, hot water safety and water efficiency. The Building Regulations 2010

Energy Efficiency in New Housing

DVS HOME VENTILATION SYSTEMS. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 375 [2014]

Installation and Maintenance

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Barnsley Accredited Landlord Scheme Accredited Property Registration Form

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

Riva Studio Dedicated Sealed External Air Kit

WHHR Midi & Midi Lite

ACTIVE VENTILATION SYSTEMS

(57.7) X. March 2006 PRODUCTS. ... the complete solution

technical specification smoke venting systems

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

Flueing and ventilation for gas appliances of rated input not exceeding 70 kw net (1st, 2nd and 3rd family gases)

Eligibility criteria

Protect Safety Alarms

Summer Works Scheme 2010

HHIC consumer guide to gas boiler servicing

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Northern Ireland HMO Fire Safety Guide

carbon monoxide alarms

T e c h n i c a l G u i d a n c e D o c u m e n t. Fire Safety. Dwelling Houses. Volume 2

Plymouth University - Application for Landlord Registration

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Certificate No: EWS534

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

FIRE AND SECURITY CONSULTING SERVICES

MAXIMISER Semi-Storage Calorifiers

Electrical Safety Policy

Specification for Road Works Series Introduction

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MHG201 Gas Hob Manual for Installation, Use and Maintenance

2006 edition. Fire safety APPROVED DOCUMENT VOLUME 1 DWELLINGHOUSES. The Building Regulations 2000

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

B COMMISSION REGULATION (EU)

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

QUALIFICATION, PRE-REQUISITES AND THE CERTIFICATION PROCESS FOR COMPETENCE CERTIFICATION SCHEMES

Installation and Maintenance

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Installation and Maintenance

Installation and Maintenance

The new Gas Appliances Regulation (EU) 2016/426

Department of the Environment Transport and the Regions Building Regulations Division

Condensation Control in New Homes. Important information for owners and occupiers

Carbon Monoxide Safety

Passive House Northwest AIA CEU Provider. Aubrey Gewehr March 27, 2015

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

NES. What s New June Contents: Detailed Technical guidance. Work section updates. (key points)

The Gas Safety (Installations and Use) Regulations 1998.

Review Fire Test Report

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Controlled Door Closing Devices

INSTALLATION INSTRUCTIONS FOR FLUE KIT

Guide to Membership Assessments

Habitability Guidelines

Introduction ... The HETAS Guide. to Approved Solid Fuel, Wood and Biomass Products and Services. List no. 24 HETAS 2018

Transcription:

Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy the requirements of the Building Regulations (Northern Ireland) 1994 ( the Building Regulations ). There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet. If you prefer you may adopt another way of meeting the requirements of the Building Regulations but you will have to demonstrate that you have satisfied those requirements by other means. Other regulations This Technical Booklet relates only to the requirements of Regulations K2 and K4. The work will also have to comply with all other relevant Building Regulations. British Standards and European Technical Specifications In this introduction and throughout this Technical Booklet any reference to a British Standard shall be construed as a reference to (a) a British Standard or British Standard Code of Practice; (b) a harmonised standard or other relevant standard of a national standards body of any Member State of the European Economic Area; (c) an international standard recognised for use in any Member State of the European Economic Area; (d) any appropriate, traditional procedure of manufacture of a Member State of the European Economic Area which has a technical description sufficiently detailed to permit an assessment of the goods or materials for the use specified; or (e) a European Technical Approval issued in accordance with the Construction Products Directive, provided that the proposed standard, code of practice, specification, technical description or European Technical Approval provides, in use, equivalent levels of safety, suitability and fitness for purpose as that provided by the British Standard. Products conforming with a European Council Directive Any product designed and manufactured to comply with the requirements of a European Council Directive does not have to comply with any other standard or part of a standard, whether British, International or other, which relates to the same characteristic or specific purpose as the EC Directive. CE marked construction products Any construction product (within the meaning of the Construction Products Directive) which bears a CE Mark shall be treated as if it satisfied the requirements of any appropriate British Board of Agrément Certificate, British Standard or British Standard Code of Practice relating to such a product, where the CE Mark relates to the same characteristic or specific purpose as the Certificate, Standard or Code of Practice. Testing of materials and construction Where for the purposes of this Technical Booklet testing is carried out it shall be carried out by an appropriate organisation offering suitable and satisfactory evidence of technical and professional competence and independence. This condition shall be satisfied where the testing organisation is accredited in a Member State of the European Economic Area in accordance with the relevant parts of the EN 45000 series of standards for the tests carried out. 1

Materials and workmanship Any work to which a requirement of the Building Regulations applies must, in accordance with Part B of the Building Regulations, be carried out with suitable materials and in a workmanlike manner. You can comply with the requirements of Part B by following an appropriate British Standard or you may demonstrate that you have complied with those requirements by other suitable means, such as an acceptable British Board of Agrément Certificate, Quality Assurance Scheme, Independent Certification Scheme or Accredited Laboratory Test Certificate. Reference Any reference in this Technical Booklet to a publication shall, unless otherwise stated, be construed as a reference to the edition quoted, together with amendments, supplements or addenda thereto current at 31 January 1998. Diagrams The diagrams in this Technical Booklet supplement the text. They do not show all the details of construction and are not intended to illustrate compliance with any other requirement of the Building Regulations. They are not necessarily to scale and should not be used as working details. Contents Page Section 1 General 3 Section 2 Domestic buildings 5 Section 3 Non-domestic buildings 8 Section 4 Ventilation of car parks 11 2

Section 1 General 1.1 This Section gives the definitions and general provisions relating to the ventilation of domestic and non-domestic buildings. Definitions 1.2 In this Technical Booklet the following definitions apply Background ventilation ventilation by means of a small adjustable ventilation opening (e.g. a trickle ventilator) some part of which is not less than 1.75 m above floor level and the sole purpose of which is to provide controllable ventilation at a low rate. Bathroom a room containing a bath or shower whether or not it also contains other sanitary appliances. Common space a space in a non-domestic building where people are expected to gather in large numbers such as shopping malls, foyers and similar common spaces but shall not include spaces used solely for circulation. Enclosed place a verandah, conservatory or similar place which is ventilated directly to the external air. Habitable room has the meaning assigned to it by Regulation A2 but does not include a room intended to be used for the lawful detention of any person other than a person of unsound mind. Passive stack ventilation (PSV) a ventilation system using a duct from the ceiling of a room to a terminal on or above the roof, which operates by a combination of the natural stack effect (i.e. the movement of air due to the difference in temperature between inside and outside) and the effect of wind passing over the terminal. Rapid ventilation ventilation by means of a large adjustable ventilation opening (e.g. a window), some part of which is not less than 1.75 m above floor level, and which allows the movement of a substantial volume of air in a short period of time. Sanitary accommodation sanitary accommodation has the meaning assigned to it by Regulation P1. Utility room a room used for laundry purposes which contains a sink, washing machine, tumble drier or similar moisture producing equipment and which is not entered solely from outside the building. Ventilation opening any part of a window, or any hinged panel, adjustable louvre or other means of ventilation which opens directly to the external air or to an enclosed place, but does not include any opening associated with a means of mechanical ventilation. Mechanical extract ventilation a system of ventilation operated by a power driven mechanism which extracts air from a room and discharges it only to the external air. Mechanical supply ventilation a system of ventilation operated by a power driven mechanism which supplies fresh air from outside the building to a room or space within the building. Occupiable room a room in a non-domestic building occupied as an office, workroom, classroom, hotel bedroom or similar room but does not include a bathroom, utility room, sanitary accommodation or rooms or spaces used solely or principally for circulation, building services plant or storage purposes. 3

Ventilation of sanitary accommodation 1.3 Where sanitary accommodation contains a cubicle or cubicles constructed so as to allow free circulation of air throughout the room or space, then the provisions shall apply to the room or space as a whole and not to the cubicle or cubicles separately. Interaction of mechanical extract ventilation and open-flued heat producing appliances 1.4 Mechanical extract ventilation can cause spillage of flue gases from heat producing appliances. The problem is mainly with openflued appliances which rely on natural draughts for their air supply, but it can also occur with fan assisted appliances. The installation of heat producing appliances is controlled by Part L and they must be able to operate safely whether or not the mechanical extract ventilation is operating. To minimise the risk of spillage of flue gases, mechanical extract ventilation (a) shall not be provided in the same room as a solid fuel burning appliance; (b) shall only be provided in the same room as an oil fired pressure jet appliance when the installation complies with OFTEC Technical Information Note TI/112. [Technical Information Note TI/112 is available from the Oil Fired Technical Association for the Petroleum Industry ( OFTEC ), Century House, 100 High Street, Banstead, Surrey, SM7 2NN]; and (c) extracting at a rate greater than 20 litres/second, shall not be provided in the same room as a gas fired appliance. ( BS 5440 : Part 1, Clause 4.3.2.3. both recommends and gives a method for a spillage test for gas fired appliances for use whether or not the mechanical extract ventilation and the combustion appliance are in the same or different rooms.) 4

Section 2 Domestic buildings 2.1 This Section gives provisions for the natural ventilation of rooms in domestic buildings and the mechanical ventilation of internal kitchens, utility rooms, bathrooms and sanitary accommodation in an otherwise naturally ventilated domestic building. Ventilation of rooms direct to external air 2.2 In a domestic building, any habitable room, kitchen, utility room, bathroom and sanitary accommodation ventilated direct to external air shall have ventilation provisions in accordance with Table 2.1. Table 2.1 Ventilation of rooms direct to external air Room (1) Rapid ventilation Background Mechanical extract opening(s) ventilation ventilation (3)(4) (minimum free area) opening(s) (2) (nominal airflow rates) (minimum free area) Habitable room 1/20th of floor area 8000 mm 2 Kitchen (5) 1/20th of floor area 4000 mm 2 30 litres/second adjacent to a hob (6) or 60 litres/ second elsewhere Utility room 1/20th of floor area 4000 mm 2 30 litres/second Bathroom (with 1/20th of floor area 4000 mm 2 15 litres/second or without WC) Sanitary 1/20th of floor area (7) 4000 mm 2 accommodation (separate from bathroom) Notes to Table (1) Where a room serves a combined function such as a kitchen-diner, the individual provisions for rapid, background and mechanical extract ventilation need not be duplicated provided that the greater or greatest provision for the individual functions in Table 2.1 is made. (2) As an alternative to the background ventilation provisions listed in Table 2.1, background ventilation openings equivalent to an average of 6000 mm 2 per room may be provided but no room shall have a background ventilation opening of less than 4000 mm 2. (3) As an alternative to mechanical extract ventilation, passive stack ventilation may be provided. Where passive stack ventilation is provided it shall be designed and constructed in accordance with BRE Information Paper 13/94 or a valid BBA Certificate. (4) Mechanical extract ventilation shall not be provided in a room where there is an open-flued solid fuel burning appliance (see paragraph 1.4). Mechanical extract ventilation (or passive stack ventilation) need not be provided in a room with an open-flued appliance which has a flue having a free area at least equivalent to a 125 mm diameter duct and the appliance s combustion air inlet and dilution air inlet are permanently open when the appliance is not in use. (5) This provision is for a domestic size kitchen where the appliances and usage are of a domestic nature. Guidance on the ventilation required for commercial kitchens is given in CIBSE Guide B, Tables B2.3 and B2.11. (6) Adjacent to a hob means either (a) incorporated within a cooker hood located over the hob; or (b) located near the ceiling within 300 mm of the centreline of the space for the hob. (7) As an alternative, mechanical extract ventilation at 6 litres/second may be provided. 5

Ventilation of an internal habitable room 2.3 Where a habitable room cannot be ventilated in accordance with paragraph 2.2 it shall be ventilated through (a) another habitable room in accordance with paragraph 2.4; or (b) an enclosed place in accordance with paragraph 2.5. 2.4 A habitable room which provides through ventilation to an internal habitable room shall have (a) a permanent opening or openings to the other habitable room with an area of not less than 1/20th of the combined floor areas of the rooms; (b) a rapid ventilation opening or openings with an area of not less than 1/20th of the combined floor areas; and (c) a background ventilation opening or openings of not less than 8000 mm 2. These provisions are shown in Diagram 2.1. 2.5 An enclosed place which provides through ventilation to a habitable room shall have (a) a rapid ventilation opening or openings with an area of not less than 1/20th of the combined floor areas of the rooms; and (b) a background ventilation opening or openings of not less than 8000 mm 2. The habitable room shall have openings for ventilation to the enclosed place of not less than the sizes given in (a) and (b) above. These provisions are shown in Diagram 2.2. Diagram 2.2 A habitable room ventilated through an adjoining space see para 2.5 8000mm 2 background ventilation in each position habitable room Diagram 2.1 Two rooms treated as a single room for ventilation purposes see para 2.4 permanent opening equal to at least 1/20th of the combined floor area conservatory or similar space both openings to provide rapid ventilation at least 1/20th of the combined floor area 8000mm 2 background ventilation provision for rapid ventilation at least 1/20th of the combined floor area 6

Ventilation of non-habitable internal rooms 2.6 Any kitchen, utility room, bathroom or sanitary accommodation which cannot have ventilation openings in accordance with paragraph 2.2 shall have mechanical extract ventilation in accordance with Table 2.2 and a permanently open air inlet having a minimum free opening area of 9000 mm 2. The mechanical extract ventilation shall have an overrun time of not less than 15 minutes and shall be activated either automatically or manually (e.g. by the operation of a light switch). Table 2.2 Ventilation of non-habitable internal rooms (1) (2) Room Mechanical extract ventilation (nominal airflow rates) Kitchen 30 litres/second adjacent to a hob (3) or 60 litres/second elsewhere Utility room Bathroom (with or without WC) Sanitary accommodation (separate from bathroom) 30 litres/second 15 litres/second 6 litres/second Notes to Table (1) As an alternative to mechanical extract ventilation, passive stack ventilation may be provided. Where passive stack ventilation is provided it shall be designed and constructed in accordance with BRE Information Paper 13/94 or a valid BBA Certificate. (2) Mechanical extract ventilation shall not be provided in a room where there is an open-flued solid fuel burning appliance (see paragraph 1.4). Mechanical extract ventilation (or passive stack ventilation) need not be provided in a room with an open-flued appliance which has a flue having a free area at least equivalent to a 125 mm diameter duct and the appliance s combustion air inlet and dilution air inlet are permanently open when the appliance is not in use. (3) Adjacent to a hob means either (a) incorporated within a cooker hood located over the hob; or (b) located near the ceiling within 300 mm of the centreline of the space for the hob. 7

Section 3 Non-domestic buildings 3.1 This Section gives the provisions for the natural ventilation of rooms in non-domestic buildings and the mechanical ventilation of internal kitchens, bathrooms and sanitary accommodation in an otherwise naturally ventilated non-domestic building. Ventilation of rooms direct to external air 3.2 In a non-domestic building, any occupiable room, kitchen, bathroom and sanitary accommodation shall have ventilation provisions in accordance with Table 3.1 and where appropriate paragraphs 3.5, 3.6 and 3.7. Table 3.1 Ventilation of rooms direct to external air Room (1)(2) Rapid ventilation Background Mechanical extract opening(s) ventilation ventilation (3)(4) (minimum free area) opening(s) (nominal airflow rates) (minimum free area) Occupiable room 1/20th of floor area for floor areas (i) up to 10 m 2-4000 mm 2 (ii) greater than 10 m 2 - at the rate of 400 mm 2 /m 2 of floor area Kitchen (5) 1/20th of floor area 4000 mm 2 30 litres/second adjacent to a hob (6) or 60 litres/second elsewhere Bathroom (including a 1/20th of floor area 4000 mm 2 per 15 litres/second per shower-room) bath/shower bath/shower Sanitary 1/20th of floor area (8) 4000 mm 2 per WC accommodation (7) (and/or washing facilities) Notes to Table (1) Where a room serves a combined function, the individual provisions for rapid, background and mechanical extract ventilation need not be duplicated provided that the greater or greatest provision for the individual functions in Table 3.1 is made. (2) For specific rooms where smoking is permitted see paragraph 3.6. (3) For domestic size facilities passive stack ventilation may be provided in place of mechanical extract ventilation. Where passive stack ventilation is provided it shall be designed and constructed in accordance with BRE Information Paper 13/94 or a valid BBA Certificate. (4) Where an open-flued appliance is provided in a building with mechanical extract ventilation, the spillage of flue gases could occur. The open-flued appliance needs to be able to operate safely whether or not the fan is running (see paragraph 1.4). (5) This provision is for a domestic size kitchen where the appliances and usage are of a domestic nature. Guidance on the ventilation required for commercial kitchens is given in CIBSE Guide B, Tables B2.3 and B2.11. (6) Adjacent to a hob means either (a) incorporated within a cooker hood located over the hob; or (b) located near the ceiling within 300 mm of the centreline of the space for the hob. (7) Where sanitary accommodation in a school or other educational establishment is for use by pupils or students see paragraph 3.7. (8) As an alternative, mechanical extract ventilation at 6 litres/second per WC or 3 air changes per hour may be provided. 8

Ventilation of internal kitchens, bathrooms and sanitary accommodation 3.3 Where a kitchen, bathroom or sanitary accommodation is an internal room it shall have mechanical extract ventilation, to extract air at a rate of not less than that given in Table 3.2, and a permanently open air inlet having a minimum free opening area of 9000 mm 2. The mechanical extract ventilation shall have an overrun time of not less than 15 minutes and shall be activated either automatically or manually (e.g. by the operation of a light switch). Table 3.2 Ventilation of internal kitchens, bathrooms and sanitary accommodation (1) (2) Room Mechanical extract ventilation (nominal airflow rates) Kitchen (3) 30 litres/second adjacent to a hob (4) or 60 litres/second elsewhere Bathroom (including a shower-room) Sanitary accommodation (5) (and/or washing facilities) 15 litres/second per bath/shower 6 litres/second per WC or 3 air changes per hour Notes to Table (1) For domestic size facilities passive stack ventilation may be provided in place of mechanical extract ventilation. Where passive stack ventilation is provided it shall be designed and constructed in accordance with BRE Information Paper 13/94 or a valid BBA Certificate. (2) Where an open-flued appliance is provided in a building with mechanical extract ventilation, the spillage of flue gases could occur. The open-flued appliance needs to be able to operate safely whether or not the fan is running (see paragraph 1.4). (3) This provision is for a domestic size kitchen where the appliances and usage are of a domestic nature. Guidance on the ventilation required for commercial kitchens is given in CIBSE Guide B, Tables B2.3 and B2.11. (4) Adjacent to a hob means either (a) incorporated within a cooker hood located over the hob; or (b) located near the ceiling within 300 mm of the centreline of the space for the hob. (5) Where sanitary accommodation in a school or other educational establishment is for use by pupils or students see paragraph 3.7. 9

Ventilation of common spaces 3.4 A common space shall be ventilated by (a) a ventilation opening or openings having an area of not less than 1/50th of the floor area of the common space; or (b) mechanical supply ventilation designed to provide fresh air at a rate of 1 litre/second per m 2 of floor area. Ventilation of rooms in which specialist activities are undertaken 3.5 The ventilation provisions in Table 3.1 may not be adequate where specialist activities are undertaken in a room. Additional ventilation should be provided in accordance with, in the case of (a) fume cupboards in a school or other educational establishment DFE Design Note 29; (b) specific workplaces and work processes HSE Guidance Note EH 22; (c) specific rooms in hospitals DHSS Activity Data Base and Department of Health Building Notes 4, 21 and 46 as appropriate; and (d) building services plant rooms which require emergency ventilation to disperse contaminating gas releases HSE Guidance Note EH 22, paragraphs 25 to 27. 3.6 Where smoking is permitted in rest rooms, mechanical extract ventilation at a rate of not less than 16 litres/second per person, shall be provided in addition to the provisions in Table 3.1. Air supply systems 3.8 Where the ventilation of a room in which a specialist activity is undertaken requires a controlled supply of air then (a) air inlets shall be sited so that they will not draw contaminated air from any adjacent source, for example, a flue outlet, exhaust ventilation outlet or an evaporative cooling tower, or from an area in which vehicles manoeuvre; and (b) measures shall be taken to avoid legionella contamination. [Guidance on such measures is contained in the Health and Safety Executive publication The control of legionellosis including legionnaires disease paragraphs 71 to 89 which should be read in conjunction with (i) BS 5720 : 1979 Clauses 2.3.2 and 2.3.3; 2.4.2 and 2.4.3; 2.5; 3.2.6; 3.2.8 and 5.5.6; or (ii) CIBSE Guide B Sections B2 and B3.] Ventilation systems 3.9 Where the ventilation of a room, in which a specialist activity is undertaken, is provided by a mechanical ventilation system its effective operation shall be ensured by (a) providing adequate access for maintenance of the system (see BSRIA Technical Note 10/92 : Sections A5 and D2); and (b) commissioning the system in accordance with a relevant commissioning code. (e.g. a CIBSE Code.) 3.7 Where sanitary accommodation in a school or other educational establishment is for use by pupils or students, the ventilation provisions given in Tables 3.1 and 3.2 will be unable to cope with peak usage e.g. break times. In these buildings, such sanitary accommodation shall be ventilated at a rate of not less than 6 air changes per hour. 10

Section 4 Ventilation of car parks 4.1 This Section gives the provisions for the ventilation of a car park for light vehicles i.e. cars, motorcycles or passenger or light goods vehicles weighing no more than 2500 kg gross. Where the car park also contains other rooms, for example, for attendants or sanitary accommodation, such rooms shall be ventilated in accordance with Section 3. 4.2 A car park which can be ventilated direct to external air at each car parking level shall have either (a) ventilation openings having a minimum free opening area not less than 1/20th of the floor area at that level, with not less than half of that area evenly distributed in two opposing walls; or (b) ventilation openings having a minimum free opening area of not less than 1/40th of the floor area at that level and a mechanical extract ventilation system capable of not less than 3 air changes per hour. The ventilation openings and the extraction points shall be located to ensure an adequate distribution of ventilation. 4.3 A car park or part of a car park which cannot have ventilation openings in accordance with paragraph 4.2 shall have a mechanical extract ventilation system capable of (a) providing general ventilation of not less than 6 air changes per hour and local ventilation at exits and ramps, where cars queue inside the building with engines running, at a rate of not less than 10 air changes per hour; or (b) ensuring that the concentration of carbon monoxide is limited so that it does not exceed (i) 50 parts per million averaged over an eight hour period; and (ii) 100 parts per million in any 15 minute period. Printed in the UK for the Stationery Office Ltd Dd 601165 C9 2/99 014567 11

12