COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Similar documents
COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

DISTRIBUTION SYSTEMS. Water Piping and Pumps

Principles of Mechanical Refrigeration

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Appendix 13. Categories of Cooling and Heating systems

ENGINEERING. Edition No. 13 October 2002

HVAC 101. H V A C S y s t e m s

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Vapor-Compression Refrigeration

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

August 15, 2013 Page 1 of 19

General HVAC Recommendations

Job Name Control Systems Description Date

C-Series. Unique Solutions for All-Indoor HVAC Projects

4. OVERVIEW OF MECHANICAL SYSTEM

COMcheck Software Version Review Mechanical Compliance Certificate

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

2009 IECC Commercial Mechanical Requirements

DISTRIBUTION SYSTEMS. Water Piping and Pumps

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

Temperature. In the HVAC area, we talk about two kinds of temperatures.

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Dehumidifying with Dedicated Outdoor Air

PDHengineer.com. Course HV Centralized Vs Decentralized Air Conditioning Systems

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

C13-Series. Unique Solutions for All-Indoor HVAC Projects

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Innovative Design, Performance, & Serviceability

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

CONTENTS. B. System Design and Performance Requirements

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

MECHANICAL SERVICES 101. Ian White

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Technical Report Three

7. MECHANICAL SYSTEM DESIGN

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Zoned Rooftop Systems. Light commercial packaged rooftop systems from Trane

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

1 - This title will copy onto other forms Date

COMcheck Software Version Mechanical Compliance Certificate

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

gforce Units Data Aire and Data Temp Series

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

APPLICATION GUIDE BEAMS

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

HVAC Design Fundamentals

Technical Assignment 3. Mechanical Systems Existing Conditions Evaluation

Advance Release September 2009

Flexible & Innovative. Cooling Solutions

GARCIA GALUSKA DESOUSA Consulting Engineers

50 Series AQUAZONE Water Source Heat Pumps

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Raised Access Floor - (AE Breadth Area)

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Leverage Building Energy Diversity in High Efficiency HVAC Design

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Explanation of Cooling and Air Conditioning Terminology for IT Professionals

Application of the 2012 North Carolina Energy Conservation Code

Summary Comparison of Simulation Program Features

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

Displacement Ventilation in Classrooms

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Transcription:

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units Technical Development Program

Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are targeted at engineers and designers who wish to develop their knowledge in this field to effectively design, specify, sell or apply HVAC equipment in commercial applications. Although TDP topics have been developed as stand-alone modules, there are logical groupings of topics. The modules within each group begin at an introductory level and progress to advanced levels. The breadth of this offering allows for customization into a complete HVAC curriculum from a complete HVAC design course at an introductory-level or to an advancedlevel design course. Advanced-level modules assume prerequisite knowledge and do not review basic concepts. Self-contained units are a unique segment of the packaged air-conditioning industry. They are available in a variety of configurations for both air-cooled and water-cooled applications. For comfort air conditioning applications, they are popular for use as spot coolers in stores, restaurants, and industrial buildings. Self-contained units are often used in multiples, usually with a cooling tower, to form a floor-by-floor system in hi-rise buildings. All sizes of self-contained units are available for constant volume (CV) applications. Smaller tonnage self-contained units can be used with zoning systems such as variable volume and temperature (VVT ) systems where multiple control zones are required. Units above 20 tons in capacity are available factorymodified for variable air volume (VAV) applications where multiple zones of control are necessary and fan energy savings is desired. 2006 Carrier Corporation. All rights reserved. The information in this manual is offered as a general guide for the use of industry and consulting engineers in designing systems. Judgment is required for application of this information to specific installations and design applications. Carrier is not responsible for any uses made of this information and assumes no responsibility for the performance or desirability of any resulting system design. The information in this publication is subject to change without notice. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Carrier Corporation. Printed in Syracuse, NY CARRIER CORPORATION Carrier Parkway Syracuse, NY 13221, U.S.A.

Table of Contents Introduction... 1 Self-Contained Unit Configurations... 2 Air-Cooled Units with Integral Condenser... 3 Remote Air-Cooled (Split System) Units... 4 Water-Cooled Units... 6 Self-Contained Unit Components... 7 Compressors... 8 Evaporator Coil... 9 Expansion Device... 11 Condensers... 11 Fans... 13 Filters... 14 Heating Options... 15 Safety Controls... 15 Self-Contained Units and Systems... 16 Advantages... 16 Disadvantages... 22 Hi-Rise Floor-by-Floor Systems... 24 Mechanical Room Layout...25 Acoustic Considerations... 26 Ductwork... 27 Vibration Isolation... 28 Waterside Economizer... 28 Variable Flow Condenser Loop... 30 Application Topics... 30 Gross, Net Capacity, EER... 30 Cooling Towers... 31 Water Quality in Tower Loop...33 Evaporative Condensers... 34 Freeze Protection... 35 IAQ Features... 36 Operating Limits... 38 Airside Economizer... 38 Integration with a WSHP System... 39 Modular Construction... 40 Air Delivery... 40 Head Pressure Control... 44 Refrigerants... 46 Refrigerant Piping for Remote Condenser... 46 Integral Ducted Condenser Fan Arrangements... 48 Electrical... 50 Controls... 51 Linkage... 52 Direct Digital Control... 53 Unit-Mounted Hardware and Software... 53 Codes and Standards... 55 ARI... 55 ASHRAE Standard 90.1...56 ASHRAE Standard 62.1 and LEED... 56 UL/ETL/CSA... 57

Electronic Selection... 57 Selection Wizard...58 Unit Selection...59 Accessories...61 Acoustic Plenum...62 Fan Performance...63 Summary... 63 Work Session... 66 Work Session Answers... 69 Appendix A Water Quality Guidelines... 71 Appendix B Performance Summary... 72 References... 73

INDOOR SELF-CONTAINED UNITS Introduction Packaged HVAC units are a large segment of the air-conditioning industry. They are easy to select and apply because they are a pre-engineered (packaged) type of product and have low installed cost. This makes them attractive to owners, contractors, and engineers. While packaged equipment covers a wide range of products, including rooftop units, this Technical Development Program module covers a specific type of packaged unit: indoor selfcontained units. Indoor self-contained units are a subset of unitary packaged products that are installed in or near the occupied space. See Figure 1. The Air Conditioning and Refrigeration Institute (ARI) defines a unitary air conditioner as one or more factory-made assemblies that normally include: an evaporator or cooling coil, an airmoving device or fan, and a compressor and condenser combination. The air conditioner may include a heating function as well. This is also a description of a selfcontained unit. In this TDP we will examine both air-cooled and water-cooled selfcontained units. For water-cooled units, their condensers are typically piped to a condenser water loop containing a cooling tower for heat rejection. For air-cooled units, the condenser is either integral to the unit cabinet or at a remote location. Versatility Indoor self-contained units offer a versatile approach to providing comfort on small single-zone or large multiplezone systems. Figure 1 Self-Contained Units The function of a packaged unit is to provide complete air conditioning, including control of temperature, humidity, air circulation, and filtering of air. Although indoor self-contained units do not directly control relative humidity, in most cases they dehumidify the air, which may result in acceptable humidity levels for most applications. Steam, hot water, or electric resistance heating coils can be added as an accessory to provide year-round control of temperature. Self-contained units are intended for installation indoors, near the occupied zones. The self-contained units discussed in this TDP are fully assembled products with factorymatched components. Little exterior piping or wiring is required for these units and they are usually five tons and larger in capacity. However, we will also discuss a spot cooling self-contained unit that is less than 5 tons. As we will learn in this TDP module, there are many design considerations involved when using self-contained units such as the use of an airside or a waterside economizer, sound dampening choices, and constant volume (CV) versus variable air volume (VAV) unit types. Variable air volume units comprise a large segment of self-contained unit configurations as they are used in the larger building systems. Commercial HVAC Equipment 1

INDOOR SELF-CONTAINED UNITS Indoor self-contained units are usually selected with software provided by the manufacturer. The selection is based on the customer s air or water-cooled requirements. An example selection of a water-cooled unit is included at the end of this TDP module. Self-Contained Unit Configurations Self-contained units are available in three different configurations. The first configuration that we will cover is an air-cooled unit with an integral, ductable condenser. Secondly, we will discuss a configuration that uses a remote air-cooled condenser. The condenser may either be an indoor type with centrifugal fans or an outdoor type with propeller fans. Lastly, we will discuss water-cooled, self-contained units. Air-cooled units usually offer lower installation and maintenance costs than water-cooled units, but air-cooled units have a higher operating cost. This is because air-cooled condensing temperatures are higher than water-cooled condensing temperatures. The higher the condensing temperature, the harder the compressor must work. This results in an increase in energy per ton of cooling produced. Figures 2 and 3 show the selfcontained unit market breakdown. Notice that below 20 tons, the selfcontained unit market is almost entirely constant volume units. The market is also predominantly aircooled units using either a remote or integral air-cooled condenser. Figure 2 Self-Contained Market Below 20 Tons Above 20 tons, water-cooled units are 75 percent of the selfcontained industry. In this category, the majority of self-contained units are variable air volume. Figure 3 Self-Contained Market Above 20 Tons 2 Commercial HVAC Equipment

INDOOR SELF-CONTAINED UNITS Air-Cooled Units with Integral Condenser We will look at the smallest self-contained units first. Some manufacturers offer horizontal indoor self-contained systems as small as 2 tons, however, the vast majority of self-contained units are vertical designs. These small horizontal designs can be conveniently located in the ceiling above the conditioned space. This saves floor space and potentially eliminates the need for return ductwork, as shown in Figure 4. Small selfcontained units are often referred to as spot coolers, because they can be located to condition a specific spot in a building, such as a conference room. These units range from 2 to 5 tons and feature a centrifugal fan condenser capable of overcoming the resistance from the intake and discharge ductwork and louvers. These units are available for constant Figure 4 volume use and have a single Horizontal Air-Cooled Unit refrigeration circuit. The small self-contained units also feature a design that permits splitting the centrifugal fan condenser section from the compressor and evaporator fan section. This allows the condenser fan to be located closer to the outside wall, minimizing airside pressure drop and ductwork length, resulting in lower condenser fan brake horsepower (bhp). As self-contained units with integral condensers increase in capacity over 5 tons, they typically use a vertical configuration. See Figure 5. The evaporator fans can be ducted or use a free blow plenum. A one-piece design incorporates a centrifugal air-cooled condenser inside the unit chassis. Vertical units with an integral aircooled condenser are typically available between 5 and 20 tons. Above 20 tons, the air-cooled condenser coil becomes large and may be difficult to design and install in a one-piece design. At 10 tons and above, self-contained units usually have multiple refrigeration circuits. Water source heat pump (WSHP) units are applied in the same manner as small capacity self-contained units. Vertical WSHP units one ton and above can be used with larger water-cooled selfcontained units. Often, the WSHP is applied in the cooling-only mode. For further information on WSHP Systems, see TDP-706, Water Source Heat Pumps. Figure 5 Integral Condenser Configuration Commercial HVAC Equipment 3

INDOOR SELF-CONTAINED UNITS Self-contained units in this capacity range are available with constant volume control. However, they can be used with a variable air volume and temperature (VVT ) system. The VVT system utilizes a constant volume unit of 20 tons and under. Air-cooled, vertical, self-contained units are used in industrial applications such as factories for larger scale spot cooling. Other applications include nightclubs, retail outlets, and restaurants. In most of these applications, the unit is located in the same space as the occupants. Figure 6 shows a typical integral condenser fan unit. Self-contained units are designed for comfort cooling applications. Another type of selfcontained unit is called close-control unit. Close-control units are designed to maintain a precise specified temperature and humidity. This type of unit comes equipped with special features and is not covered in this TDP module. An example of a close-control unit would be a dedicated computer room unit equipped with extra steps of capacity control, humidification controls, and other special features built into the design. Easy Installation Vertical air-cooled units are often used in retail stores with a free blow discharge plenum mounted on top of the unit. No ductwork is used. If there is access to an outside wall or window, condenser air intake and discharge is easily accomplished. Figure 6 Self-Contained Unit with Integral Condenser Remote Air-Cooled (Split System) Units This type of air-cooled self-contained unit can use one or more remote condensers to form a split system. This configuration is available in larger sizes, up to 60 tons. Above 60 tons, the number and size of the remote condensers required becomes less practical and multiple air-cooled selfcontained units or a single large water-cooled unit are used instead. Split systems require field-installed refrigerant piping and separate power supplies for the self-contained unit and the condenser section. Split systems are limited to about 100 to 200 feet in their total separation distance depending on the tonnage and manufacturer. This limits the application of these units on larger buildings. Figure 7 Split System Outdoor Remote Condenser 4 Commercial HVAC Equipment