INSTALLATION & OPERATION MANUAL

Similar documents
INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

Please read this manual completely before attempting to install, operate or service this equipment

ADD FLUID 300 NDNL 300 CT 300 OC 700 NDNL 725 NDNL 950 NDNL

INSTALLATION & OPERATION MANUAL

Insta-Therm Series Service, Installation and Operation Manual

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE

E-Chef Hot Food Table Installation and Operation Manual

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE

INSTALLATION & OPERATION MANUAL

I N ST ML (3-PAN, SELF-SERVICE) ML (4-PAN, SELF-SERVICE)

INSTALLATION & OPERATIONAL MANUAL

Owner s Guide Installation & Operation

Duke Manufacturing Co.

Freshly-drawn Traditionally Served Environmentally Friendly Specially Branded. Owner s Manual. V3 Dispensing System MODEL V3-203

Solid Door Top Mount Reach-In Freezer

Please read this manual completely before attempting to install, operate or service this equipment

For additional information on Vulcan-Hart or to locate an authorized parts

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATIONAL MANUAL

PRO SERIES GAS FRYERS OWNER S MANUAL

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Glass Door Merchandiser Refrigerator and Freezer

Freshly-drawn Traditionally Served Environmentally Friendly Specially Branded. Owner s Manual. V3 Dispensing System MODEL V3-202.

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

INSTALLATION & OPERATION MANUAL GAS CHARBROILERS

MHC-1 Holding Cabinet Series Service, Installation and Operation Manual

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

MD 25/40/48. 3, 4, 5 level INSTRUCTIONS IMPORTANT! Installation, operation and care of: MD Series Multideck Hot Food Display Cases

Chef Base Refrigerators

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES.

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

Owner s Guide Installation & Operation

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

INSTALLATION & OPERATIONAL MANUAL

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

INSTALLATION & OPERATION MANUAL

Professional Warming Drawer and Warming Drawer Cabinet

OWNER S MANUAL MODELS AP8, AP8B, AP8C, AP8D DUMP STATION HEATER

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

AIR SCREEN REFRIGERATOR MODELS PHB495 & PHB15 OWNER / OPERATOR S MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

INSTALLATION & OPERATION MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

As a safety precaution we recommend all instructions and safety tips appearing in this manual be reviewed prior to operation.

INSTALLATION & OPERATION MANUAL

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS

INSTALLATION & OPERATION MANUAL GAS 2/3 JACKETED STATIONARY AND TILTING KETTLES MODELS K60GLT

Wine Cellar. Instruction Booklet. Model: WC-2038

OPERATING INSTRUCTIONS

CNH12LP CNH28 CNH40 CNH28LPC

ELECTRIC COUNTERTOP DECK OVEN INSTALLATION & OPERATING MANUAL

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

HOT DOG STEAMER Instruction Manual Models: 8007 & 8012

V SERIES HDR GAS RANGES

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMERS MODELS: GSX-5HE GSX-7HE GSX-10HE GSX-16HE

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

USER MANUAL Gas Countertop Charbroilers

Direct Draw Equipment

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCMQ Series Hot Cabinet and H138NPSCMQ-15A Series Hot Cabinet

Please read this manual completely before attempting to install, operate or service this equipment

OPERATING INSTRUCTIONS

Please read this manual completely before attempting to install, operate or service this equipment

INSTALLATION & OPERATIONAL MANUAL

Use and Care Manual. For Beverage Cooler RU

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

OPERATING, INSTALLATION, SERVICE & PARTS MANUAL FOR MEDIUM DUTY GAS CHAR BROILERS MGB-A SERIES

OPERATING INSTRUCTIONS

Operation Manual and Parts Directory

FlexiShield Food Shields

FOOD WARMING/MERCHANDISING CABINET

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RRE SERIES (ELECTRIC RANGE & CONVECTION)

FTM-LE SERIES SINGLE OR TWIN ELECTRIC STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INSTALLATION - OPERATION - MAINTENANCE

Safety Instructions... 2, 3 Installation Instructions... 4 Operating Instructions Control Settings... 5

Coldwells Models: CW-1, CW-2, CW-3, CW-4, CW-5

UNDERCOUNTER DISHWASHER

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

User Manual / Installation Instructions

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

REFRIGERATED CONDIMENT RAIL

Transcription:

CBFT SERIES CORRECTIONAL HEATED HOLDING CABINETS INSTALLATION & OPERATION MANUAL MODELS: CBFT CBFTHS ML-152028-0000Z ML-152029-0000Z VULCAN 3600 NORTH POINT BLVD. DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC BALTIMORE, MD 21222 www.vulcanequipment.com Vulcan 2014 All Rights Reserved F-47102 (06-14)

F-47102 (06-14) CBFT SERIES IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL ELECTRICAL EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START- UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITYOF THIS OR ANY OTHER APPLIANCE. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing equipment. IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE 1

F-47102 (06-14) CBFT SERIES TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY........................................ 1 GENERAL........................................................... 3 INTRODUCTION................................................. 3 INSTALLATION.................................................. 3 ELECTRICAL REQUIREMENTS..................................... 4 OPERATION......................................................... 5 CONTROLS..................................................... 5 OPERATING INSTRUCTIONS...................................... 5 CLEANING...................................................... 6 STAINLESS STEEL CARE......................................... 6 MAINTENANCE.................................................. 7 TROUBLESHOOTING.................................................. 8 SERVICE & PARTS INFORMATION....................................... 8 2

F-47102 (06-14) CBFT SERIES GENERAL INTRODUCTION Vulcan Heated Holding Cabinets are produced with quality workmanship and material. Proper installation, usage, and maintenance of your cabinet will result in many years of satisfactory performance. It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions provided. The CBFT Correctional Holding Cabinets are Heavy Duty and designed for tough transportation operations. INSTALLATION Before installing, verify that the electrical service agrees with the specifications on the rating plate located on the lower back corner of the cabinet. (Fig.1) If the supply and equipment requirements do not agree, do not proceed with unpacking and installation. Contact your Vulcan Customer Service Department immediately. UNPACKING: The Cabinet was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage to the cabinet. If the cabinet is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. 1. Open the door and carefully remove any packaging materials. 2. Peel off vinyl protection film. CLEANING: The cabinet should be thoroughly cleaned prior to putting into service. Use a mild soap and water solution to clean the interior of the unit. Never use harsh chemicals or abrasive pads to clean the unit. Refer to cleaning instructions in this manual. LOCATION: For efficient cabinet operation, choose a location that will provide easy loading and unloading without interfering with the final assembly of food orders. The installation location must allow adequate clearances for servicing and proper operation. Carefully unpack and place in a work accessible area as near the installation position as possible. 3

F-47102 (06-14) CBFT SERIES ELECTRICAL REQUIREMENTS ELECTRICAL CODES & STANDARDS: The cabinet must be installed in accordance with: In the United States of America: 1. State and Local Codes. 2. National Electrical Code, ANSI/ NFPA-70 (latest edition.) Copies may be obtained from: The National Fire Protection Association, 1Batterymarch Park, Quincy, MA 02269. 1-617-770-3000 www.nfpa.org In Canada: 1. Local Codes. 2. Canadian Electrical Code, CSA C22.1 (latest edition.) Copies may be obtained from: The Canadian Standard Association. www.csa.ca All cabinets are equipped with a three-prong plug. It is imperative that this plug must be connected into a properly grounded three-prong receptacle. If the receptacle is not the proper grounding type, contact an electrician. Do not remove the grounding prong from this plug. Verify that the power source matches the Serial Data Plate located on the lower back corner of the cabinet and the plug configuration before the connection is made. (Fig.1) SERIAL DATA PLATE ELECTRICAL CONNECTIONS: The cabinet is factory wired for 120 volt single phase operation. The cabinet is equipped with an 8 foot cord and a NEMA 5-15 plug as standard equipment. Refer to wiring diagrams in the back of this manual. The cord and plug supplied is a suitable durable cord with a molded three-prong plug, and is provided with a heavy-duty strain relief. (Fig.1) 4

F-47102 (02-14) CBFT SERIES OPERATION CONTROLS ON/OFF SWITCH The cabinet is pre-set/programmed at the factory at a recommended temperature of 165⁰ F. OPERATING INSTRUCTIONS Once the cabinet has been properly installed by competent service people, cleaned, and connected to the appropriate power source, the cabinet is ready for operation. TEMPERING: At least 1 (one) hour prior to loading the cabinet with the trays, plug the cabinet into the proper electric outlet, and switch the rocker switch to the ON position. Allow the cabinet to run while the doors remain closed. In 1 (one) hour, the temperature inside should be 165⁰. ( + / - 10 degrees ). LOADING: Insert bulk food trays onto supplied shelves as quickly as possible, exposing only small quantities to room temperature for short periods of time. Load the cabinet while it is running, keeping the doors closed as much as possible. When the cart is loaded, allow the temperatures to recover for approximately 10 minutes prior to transporting cabinet. UNLOADING: Once cabinet has been transported, plug the cabinet into an appropriate electrical outlet. This will re-activate the heating element and automatically hold the temperature at 165⁰. While the meal trays are being distributed, keep the door closed as much as possible. At the completion of the meal service, restack the trays within the cart, and return the cabinet and trays to the washing area. The temperature in any heated cabinet will fluctuate with door opening and transportation. The operator should always monitor the food product to insure that it remains at a proper temperature. 5

F-47102 (02-14) CBFT SERIES CLEANING Always UNPLUG ELECTRICAL POWER SUPPLY before cleaning. Keep the cabinet clean and sanitary so it will meet your local sanitation code. DO NOT USE HIGH PRESSURE WATER OR STEAM ON THE CABINET, FLOOD WITH WATER, OR ALLOW ELECTRICAL PARTS TO BECOME WET. DAILY: 1. Unplug electrical power supply. 2. Allow cabinet to cool before cleaning. 3. Clean the interior of the cabinet with a mild soap and water. Never use harsh chemicals or abrasive pads to clean the cabinet. 4. Rinse and dry with a soft dry cloth. 5. Clean the exterior of the cabinet with a clean damp cloth. HEAVY-DUTY CLEANING: For heavy-duty cleaning, use warm water, a degreaser, and a plastic, stainless steel, or Scotch-Brite pad. Never rub in a circular motion -- rub gently in the direction of the steel grain. Always rinse thoroughly. STAINLESS STEEL CARE CLEANING: Stainless Steel contains 70 80% iron, which will rust if not properly maintained. Stainless Steel also contains 12 30% chromium, which forms an invisible passive, protective film that shields against corrosion. If the protective film remains intact, the stainless steel will remain intact. However, if the film is damaged, the stainless steel can break down and rust. PREVENTIVE CARE: To prevent stainless steel breakdown, follow these steps: 1. Never use any metal tools, scrapers, files, wire brushes, or scouring pads (except for stainless steel scouring pads,) which will mar the surface. 2. Never use steel wool which will leave behind particles that will rust. 3. Never use acid-based or chloride containing cleaning solutions which will break down the protective film. 4. Never rub in a circular motion. Always rub gently in the direction of the steel grain. 5. Never leave any food products or salt on the surface. Many foods are acidic. Salt contains chloride. 6

F-47102 (02-14) CBFT SERIES PRESERVING & RESTORING: Special stainless steel polishing cleaners can preserve and restore the protective film. Preserve the life of stainless steel with a regular application of a high-quality stainless steel polishing cleaner, as a final step to daily cleaning. If signs of breakdown appear, restore the stainless steel surface. First, thoroughly clean, rinse, and dry the surface. Then, on a daily basis, apply a high-quality stainless steel polish according to manufacturer s instructions. MAINTENANCE HEAT TINT: Darkened areas, called heat tint, may appear on stainless steel exposed to excessive heat. Excessive heat causes the protective film to thicken. This is unsightly, but is not a sign of permanent damage. To remove heat tint, follow the routine cleaning procedure. Stubborn heat tint will require heavy-duty cleaning. The cabinet and its parts are HOT. Be very careful when operating, cleaning, or servicing the cabinet. Always unplug electrical power supply before servicing the cabinet. Beyond periodic inspections, checking for frayed or damaged power cord, plug, hinges, racks, and overall cabinet body, there is little maintenance required. The caster axles, however, should be kept free of foreign objects such as mop strings, plastic, etc. Depending on the handling of the cabinet, the casters should be greased at least quarterly. If harsh detergents are used, more frequent greasing will be required. LOCKOUT / TAGOUT PROCEDURE Always perform the LOCKOUT / TAGOUT Procedure of your facility before attempting to service this equipment. The Lockout / Tagout Procedure is used to protect personnel working on an electrical appliance. Before performing any type of maintenance or service on an electrically operated appliance, follow these steps: 1. In electrical box, place unit s circuit breaker into OFF position. 2. Place a lock or other device on electrical box cover to prevent someone from placing circuit breaker ON. 3. Place a tag on electrical box cover to indicate that unit has been disconnected for service and power should not be restored until tag is removed by maintenance personnel. 4. Disconnect unit power cord from electrical outlet. 5. Place a tag on cord to indicate that unit has been disconnected for service and power should not be restored until tag is removed by maintenance personnel 7

F-47102 (02-14) CBFT SERIES. TROUBLESHOOTING SYMPTOMS POSSIBLE CAUSES REMEDY Cabinet not connected to power source. Connect cabinet to power source. Cabinet not operating ON/OFF switch not ON No power. Turn ON/OFF switch ON Check circuit breaker Check GFCI GFCI or Ground Fault Circuit Indicator tripped Cabinet is connected to power source, switch is ON, circuit breaker is ON, but cabinet is not heating. Cabinet does not heat properly Fan not operating Moisture problem. Shorted element Pinched/damaged wire. Damaged power cord. Defective: element, thermometer, thermostat, etc. Door not shut properly or needs adjustment Defective: element, thermometer, thermostat, thermostat requires adjustment ON/OFF switch not ON Defective fan. Dry moisture problem. Contact Authorized Service Provider. Contact Authorized Service Provider. Contact Authorized Service Provider. Contact Authorized Service Provider. Check door seal and Contact Authorized Service Provider. Contact Authorized Service Provider. Turn ON/OFF switch ON Contact Authorized Service Provider. SERVICE & PARTS INFORMATION To obtain Service and Parts information concerning this model, contact Vulcan-Hart Service Department at the address listed on the front cover of this manual or refer to our website: www.vulcanequipment.com for a complete listing of Authorized Service and Parts depots. Customer Service 1-800-814-2028 Technical Service 1-800-814-2028 Service Parts 1-800-814-2028 8

F-47102 (02-14) CBFT SERIES 9

F-47102 (02-14) CBFT SERIES 10