Manhattan Fire Protection District

Similar documents
2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

CARBON MONOXIDE (CO)

Model Carbon Monoxide (CO) Alarm Response Policy

Travis County Emergency Services District #1 Standard Operating Guidelines

Carbon Monoxide Poisoning

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

Carbon Monoxide Safety Information

Protecting Children from Carbon Monoxide Poisoning

CARBON MONOXIDE DETECTOR, i4h-co-m330

Carbon Monoxide Detectors. What is carbon monoxide?

Ontario is taking another step to keep families and homes in Ontario safe by making carbon monoxide alarms mandatory in all residential homes.

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

Seriously how do you know your CO monitor is Working!

Carbon Monoxide Alarm Response Guide. High Country Training Center Training On Demand

Frequently Asked Questions About Carbon Monoxide Detectors

Carbon Monoxide Detection in Buildings Frequently Asked Questions

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

Carbon Monoxide Alarm

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

Frequently Asked Carbon Monoxide Questions

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

The Village of Franklin Gas Safety Pamphlet

Special Edition. Routt County Office of Emergency Management. Carbon Monoxide The Silent Killer. What is Carbon Monoxide (CO)?

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

System-Connected Carbon Monoxide Detectors

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

Office of the Fire Commissioner

This About Your House answers often-asked questions about carbon monoxide to help you make the right decision to make your home safe.

Red Alarm Indicator Light

can quickly rise to dangerous levels

carbon monoxide Preventing carbon monoxide poisoning in your home

NATURAL GAS SAFETY. Your safety. Our priority Update

about your house Carbon Monoxide

Natural Gas Pipeline Safety. EDM Services, Inc. April 2009

TEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms

Home Heating MORE THAN JUST STAYING WARM

OWNER S MANUAL for Models:

LA GRANGE FIRE DEPARTMENT JANUARY 2018

OWNER'S MANUAL PLEASE READ AND SAVE!

Carbon monoxide household alarm. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

COMPUTHERM. CO1400 Carbon Monoxide Alarm OPERATING INSTRUCTIONS

Carbon Monoxide Alarm User s Manual

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Notes From the Commish

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Models & ABOUT THIS ALARM

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Suburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL 65 Series Surface Mount Models: , R, MS, R-MS

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

From Your Building Inspector

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL Models RV & RV ABOUT THIS ALARM

Carbon Monoxide Alarm Owner s Manual

INTRODUCTION USER S MANUAL TABLE OF CONTENTS HOW YOUR CO ALARM WORKS THE COVER OF YOUR CO ALARM BASIC SAFETY INFORMATION

EL195DFE SERIES GAS FURNACE WARNING

WARNING FIRE OR EXPLOSION HAZARD.

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

TIMOTHY R. SZYMANSKI Instructor

PLUMBING & CARBON MONOXIDE

EL195UH SERIES GAS FURNACE WARNING

SAFETY TIPS. From Your Building Inspector. The Sound of Safety.

NATURAL GAS SAFETY. Este folleto está disponible en Español. Visite o llame al

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

Housing Division Notice

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

RESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO

Carbon Monoxide Room Alarm Installation and User Guide Part No:

Macurco Gas Detection Products

USER S INFORMATION MANUAL

G61MPV SERIES GAS FURNACE WARNING

OWNER S MANUAL for Models:

ML180UH SERIES GAS FURNACE WARNING WARNING

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

MODEL FCD3N User s Manual Battery-Operated Carbon Monoxide Alarm

Installation and User Guide

WARNING FIRE OR EXPLOSION HAZARD.

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

WELCOME TO ROSEVILLE UNIVERSITY

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

Carbon Monoxide Alarm. with 10 Year Permanent Power Sealed Battery

BASIC SAFETY INFORMATION TABLE OF CONTENTS INSTALLATION USER S MANUAL PLUG-IN CARBON MONOXIDE ALARM WITH BATTERY BACK-UP AND SILENCE FEATURES

Carbon Monoxide Alarm User s Guide

3 Macurco Carbon Monoxide Detector CM-16A

Contents

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Carbon Monoxide Alarm. with 10 Year Permanent Power Sealed Battery

Introductions HERS Industry HERS Ratings ACCA Standard 12 Resources

COMBUSTION SAFETY BASICS

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Carbon Monoxide Alarm User Guide

Carbon Monoxide Alarm User s Guide

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Carbon Monoxide Alarm User s Guide

Macurco CM-E1 Carbon Monoxide Detector

ADT Carbon Monoxide Alarm

USER S INFORMATION MANUAL

Carbon Monoxide: The High Cost and Affects of Complacency

RV Carbon Monoxide Alarm

Transcription:

Section: RESCUE OPERATIONS Page 1 of 5 PURPOSE: This procedure is established to ensure proper detection and mitigation of carbon monoxide alarms and emergencies, and to provide a standard of response to the same. SCOPE: The Manhattan Fire Protection District has established the following procedure regarding the response to and detection of carbon monoxide (CO) alarms and emergencies. This procedure shall apply to all personnel operating at the scene of a carbon monoxide emergency incident. ENFORCEMENT: The primary responsibility for adherence to this procedure rests with each individual. Company Officers are responsible for enforcement of this procedure. APPLICATION: A carbon monoxide problem or alarm sounding in a structure of the district will require an Engine and Ambulance response of the appropriate still district at a minimum. Characteristics of Carbon Monoxide (CO): 1. Carbon Monoxide is an odorless, tasteless, colorless gas that can be deadly in relatively low concentrations. It is a by-product of incomplete combustion originating from fuels such as wood, oil, propane, coal, gas, kerosene or charcoal. These types of fuels can be found to be used in appliances such as furnaces, grills, dryers, fireplaces, ranges, water heaters, and autos. When a faulty device, or condition exists, carbon monoxide may be vented into areas where humans are present causing carbon monoxide poisoning. 2. Carbon monoxide has a specific gravity of.97, which causes the gas to be distributed evenly from floor to ceiling. Carbon monoxide has a lower explosive limit (LEL) of 12.5% and an upper explosive limit (UEL) of 74.2%. Ignition temperature of carbon monoxide is 1,128 degrees Fahrenheit. 3. The greatest danger of carbon monoxide is its attraction to the hemoglobin in the bloodstream. CO is inhaled through the lungs and bonds with the hemoglobin in the blood displacing the oxygen that the body needs to function. CO accumulates in the bloodstream forming a toxic compound, this compound called carboxy hemoglobin (CO poisoning) may cause the following symptoms: Beginning stages: head pressure, weakness in the knees, confusion, nausea, and ringing in ears. Ending stages: increasing weakness and confusion, severe frontal headache, dizziness, inability to think clearly, vomiting, loss of consciousness, drop in blood pressure, pulled reflexes, convulsions, loss of muscular control, shallow to absent respirations, death.

Section: RESCUE OPERATIONS Page 2 of 5 Detector Parameters and Alarm Settings: Underwriters Laboratories standard for residential carbon monoxide detectors require them to alarm prior to: 1. 400 PPM in 15 minutes 2. 200 PPM in 35 minutes 3. 100 PPM in 90 minutes Types of residential carbon monoxide detectors and different methods of reading each type: 1. The typical 110V detector plugs directly into a household outlet. These detectors have lights and audible warning tones: Green light indicates the unit is receiving power. Flashing yellow light indicates a warning alarm, this flashing light will be accompanied with 3 to 5 beeps every 5 minutes. Red light indicates a full alarm and is accompanied with a constant alarm. 2. The typical battery 3. The digital readout detectors are usually 110V monitors that plug directly into household outlets. These detectors have audible warning tones, but instead of a light they have a screen that displays the Parts Per Million being read by the detector. There are also combination smoke/co detectors that are hardwired with a battery back-up. 4. The performance of all detectors may be affected by a number of contaminates which may produce false alarms, while others may delay the onset of an alarm or damage the sensor. Some of these contaminates include: Hair spray Alcohol fumes Ammonia fumes Perfume Paint or thinners Cleaning products Steam or humidity Silicone sprays (will damage most sensors) Charging of lead acid batteries. Responding to Carbon Monoxide Alarms: There are two types of carbon monoxide calls, those where the occupants are experiencing symptoms of CO poisoning and those where the occupants are not having symptoms. Although the assessment of these situations will be the same, the responses will differ.

Section: RESCUE OPERATIONS Page 3 of 5 CO ALARM WITHOUT SYMPTOMS: 1. Engine and Ambulance shall respond non emergency to all reported CO alarms. 2. Once units have arrived on the scene and evaluate the situation, additional equipment may be requested. The response status (emergency vs. non-emergency) of any additional equipment shall be determined by the Officer/firefighter in-charge on the scene. CO ALARM WITH SYMPTOMS: 1. Engine and Ambulance from both stations shall respond immediately in emergency mode to CO alarms when occupants are experiencing symptoms of CO poisoning. 2. Additional units will respond per SOP# 401-1b Conducting an Assessment for Carbon Monoxide: The following procedures shall be followed for all CO alarms regardless of whether or not occupants are experiencing symptoms: 1. When arriving at the scene normal procedures shall be followed for equipment placement, keeping in mind the possible response of additional equipment. 2. An interview shall be conducted by the Officer/firefighter in-charge with the occupant to determine the level of risk to personnel. If anyone is experiencing signs or symptoms of CO poisoning, appropriate actions shall be taken to treat any victims. 3. All personnel entering the structure shall be in full Personal Protective Equipment (PPE) with SCBA on but not breathing air. 4. The monitor shall be turned on and zeroed outside and away from the origin of the alarm and away from any responding equipment. This shall be done in an area assumed to be free of carbon monoxide. 5. Monitoring shall begin as personnel enter the structure. Test open-air throughout the structure at eye level; unlike natural gas, carbon monoxide is slightly lighter than air and minimal circulation is needed to keep it diffused throughout the room. If an immediate open-air reading of 35 PPM or greater is received, the following shall be immediately initiated: All personnel shall be in full PPE and breathing air. All occupants shall be evacuated. Ventilation shall be initiated until the occupants are evacuated. Ventilation shall stop once occupants have been evacuated (to assist in finding source of CO), unless levels are above 100 PPM. Officer/firefighter in-charge shall determine if further resources are needed to stabilize the incident. 6. Operate all fuel-burning appliances in structure approximately 5 minutes, move at a walking pace towards the most likely source. Using the following procedures and the CO Checklist, systematically assess the structure documenting readings along the way.

Section: RESCUE OPERATIONS Page 4 of 5 Gas Furnace and Water Heater: Visually inspect venting pipes and draft hoods for gaps, leaks or clogs which could prevent exhaust products from venting properly. With monitor, check the same area taking samples at each elbow and around draft hood. Visually inspect the combustion chamber, checking for an access panel and a pure blue flame, without any discoloration or damage to this area. Test around this area with monitor. Gas Clothes Dryer: Visually inspect vent piping for crimping and observe whether the appliance is too close to the wall. With monitor, sample around the door to check the seal and at the access panel or combustion chamber. Check for a pure blue flame and confirm no CO is escaping from an inadequate pilot. Space Heaters/Gas Logs: Visually check the area around the pilot and combustion chamber. Repeat this process with monitor. Check prior to and during operation for any escaping CO. Fireplace: Check for a damaged, inadequate, clogged or obstructed chimney and flue. If in use, check with monitor for proper venting and possible backdrafting. Gas Range/Oven: Visually inspect access panels and vent piping for soot build-up or clogs. Check for a pure blue pilot light and with monitor, for any escaping CO from the combustion chamber. With monitor check inside of oven for any CO. With monitor check around burners for CO. Attached Garage: With monitor check ambient air in garage. Check around autos and other fuel powered equipment and heaters.

Section: RESCUE OPERATIONS Page 5 of 5 7. If an appliance is found to be the source, the appliance and its fuel source shall be shut off, ventilate the structure until the open-air in the structure returns to a safe level. Officer/firefighter in-charge shall notify the gas company and advise the homeowner of problem and suggest a corrective action. NO MEMBER SHALL ATTEMPT TO RE-LIGHT A PILOT OR RE- START/REPAIR ANY APPLIANCE/DEVICE. 8. If the source cannot be found, you may contact the homeowners gas/lp company to assist personnel in locating the source. 9. Once the open-air spaces in the structure have returned to a safe level, the structure may be re-entered at the discretion of the incident commander, utility representative and the occupants. 10. Advise the owner/occupant of any actions taken, and repairs/problems that need corrected. Officer/firefighter in-charge shall fill out a Carbon Monoxide follow up letter and review it with the owner/occupant. Use of the RAD 57: The RAD 57 shall be used on each occupant of the structure and any firefighter that was inside of the structure to verify findings of CO in the structure. If the RAD 57 detects a SpCO reading greater than 10 or the the occupant is showing signs and symptoms of CO poisoning, you must treat and transport occupant per EMS protocol. For structures with high occupancy EMS triage protocols shall apply. Approved by Chief Daniel Forsythe Date 1/1/11

Manhattan Fire and Ambulance District 100 Park Road P.O. Box 65 Manhattan, Illinois 60442 Station 1 (815) 478-3197 Station 2 (815) 478-5578 Fax (815) 478-9880 Dear Resident, Carbon Monoxide (CO) is an odorless, tasteless, colorless gas that is DEADLY. It is a by-product of a fuel burning process. It can cause symptoms that can mimic the Flu, result in unconsciousness and even death. Many appliances around the home are capable of producing Carbon Monoxide when a faulty or unusual condition exists. Since the source may be transient, it may not always be detectable. Carbon Monoxide ( ) was ( ) was not found by our instruments. This does not mean that this was a false alarm. Our instruments found the highest average interior level of CO to be Parts Per Million (PPM). WHAT DOES THIS READING MEAN? 9 PPM or less: Our instruments did not detect elevated levels at this time. This does not mean that higher levels did not exist prior to our arrival nor that higher levels will not accumulate after our departure. Check your Carbon Monoxide detector per the manufacturer s recommendations. Call the Gas Company or appliance repair company as an added precaution. 10 PPM to 35 PPM: Our instruments have detected potentially dangerous levels of Carbon Monoxide. We have shut down the affected appliance and recommend that you not use it until it has been repaired. As an added precaution you may wish to call the Gas Company. 36 PPM to 99 PPM: This exceeds the maximum allowable concentration for continuous exposure in any 8-hour period according to OSHA (for an adult). Concentrations at this level require immediate action including evacuation of the premises, ventilation, shutting down affected appliances and fuel sources, and notification of Gas Company. 100 PPM or greater: We have detected a potentially lethal level of Carbon Monoxide in your home. We have shut off all fuel sources and requested that you leave your building immediately and not return until repairs are made and tested by the Gas Company. A licensed technician should make repairs. After repairs are made, replace or reset your Carbon Monoxide detector according to the manufacturers specifications.