REFRIGERANTS. Refrigerants

Similar documents
Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Ceramic insulated band heaters

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Mica insulated band heaters

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Chapter 2. Alternatives to HCFCs and their Characteristics

INSTRUCTION MANUAL AND WARRANTY

Mica insulated flat heaters

Small is beautiful and useful anywhere... Electric "Point of Use" Water Heaters "Open-Outlet" for single outlet "Unvented" for one or more outlets

HAZARDOUS AREA. The very best in high pressure water jetting systems SURFACE PREPARATION/ COATING REMOVAL PIPE CLEANING HEAT EXCHANGER CLEANING

ELECTRIC UNDERFLOOR HEATING

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Electrorad Digi-Line. Installation, Operating & Instruction Manual. After Sales Service:

Turbosteam iron steam/spray/steam boost

MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL. heatingthroughinnovation. APRIL 2013

Buderus. Quality Doesn t Cost It Saves! Comfortable. Efficient. Intelligent Heating. GA124 GA244 Gas Boilers Sealed Combustion Draft Induced.

Operating Manual. Model Coolant Exchanger

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Positively Innovative R32 R32. Instructions for Use and Handling

Machinery Space Fire Protection System from an Approved Product Portfolio

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Thermo shaker PHMP/ PHMP-4

Think FATI for Hot Solutions

''HEAT TRANSFER STUDIES"

Code Accessories HUB RADIATOR PACK. First start from 1 to 2 HR booster

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

The natural solution for domestic refrigeration

Update on Refrigerant Blends

Responsible Care Product Stewardship for Refrigerants

Thermo shaker PHMP/ PHMP-4

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Spray Etching Device

PRODUCT CATALOG MEDICAL AUTOCLAVE.

Our home standard. Your home is where our heart is...

Classic ECO. Eco Series -86 C Ultra-low Freezer KM-DU34H1E

HFCs or the Old Refrigerants - what is the best Choice?

EPLE Air-Cooled. Chillers. EUWA*5-24KZ / EUWY*5-24KZ Hydronic systems

Chapter 10. Refrigeration and Heat Pump Systems

HOW TO INCREASE YIELD AND IMPROVE PROPERTY VALUES? WITH ADEQUATE SOIL DECOMPACTION!

REQUIRED CONDITIONS FOR OPTIONAL OPERATION OF AN AIR-CONDITIONING SYSTEM

. Ev d & AUTOMATIC WASHER

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

water-cooled CHILLERS

Globo H. Ball valves Gunmetal ball valve

UseAndCare. -. wh H 01. nawtouua*naur~- I Call our Comumw Aubtmnca Center with quwiion* cf ccmmonb. AIR CONDITIONERS

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

30 and 36 m Sealed Burner

INUI-LEDSDL10 Specification

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Use & Care Guide. SELF-CLEANINGAS RANGE SF370PEW (Shown) SF365BEW. Stop time w Clean indicator light. Oven vent \ Burner grates

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

c P UseAndCare I ROPER Call us with questions or comments. J3ome Appliances

NO-FROST REFRIGERATOR-FREEZERS Ell8DK Ell8RK

11/22/2014. (c) DR.A.M.SURENDRA KUMAR

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

Clean and simple waste water removal

ANCILLARY DEVICES. Contents. Fire System Document Box. EN54-4 Approved Power Supply Units. Transformer Rectifier 24v Door Retainer Power Supply Units

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

Operating Instructions OPTISWITCH 3100 C with contactless electronic switch

UseAndCare. T&f1 HOme Appliances 01. A Note To You. Important Safety Instructions. Parts And Features. Using Your. Refrigerator. Caring For Your 15

ComfiGrip iron steam/spray/shot/press

UseAndCare. lq l 301 Call our Consumer Assistance Center with questions or comments.

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 -

Natural refrigerants - naturally efficient

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

UseAndCare I 301 Call our Consumer Assistance Center with questions or comments. 22 TO 25 NO-FROST TOP FREEZER REFRIGERATOR

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Low GWP alternative refrigerants to R404A

4/19/2013. The Changing State of Refrigerants

PRODUCT CATALOG MEDICAL REFRIGERATOR. LABSTAC LTD, Kemp House, 152 City Road, London EC1V 2NX, United Kingdom. labstac.

Code Accessories HUB RADIATOR HRC. mod. Connection BUS mod.

UseAndCare. Tikll I 301 Call us with questions or comments. MODEL RF354BXD

E W I TY S RP. ISO 9001:2008 Certified Co. EOT Crane DSL BUSBAR Systems FESTOON Systems BOX TYPE DSL Systems PENDANT Stations

UseAndCare. TLidl Call our Consumer Assistance Center with questions or comments.

DC Disconnect with remote control and arc fault detection PVREM-...-AF1

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

Retrofitting Existing Systems

The Problem of Counterfeit Refrigerants

Design of LPG Refrigeration System

Operating Instructions OPTISWITCH 3100 C with transistor output

INSTALLATION INSTRUCTION

solo A complete range of test and maintenance equipment for smoke, heat and CO detectors. detectortesters Solo 330 Aerosol Dispenser

Ammonia. Background on ammonia as a refrigerant

2

AUTOMATIC MARINE AND RV TOILETS

I Call ua with que6tion6 or comm6nb. TWO SPEED AUTOMATIC

A Note To You 2. Understanding Safely 3. Knowin Your Dryer s F eatures 5. Operating Your Dryer 6. Laundry Tips 16. E2tE 22.

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Propane A Replacement Refrigerant For Cfcs and Hcfcs

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

UseAndCare ONE SPEED AUTOMATIC

ASHRAE Technical Committees Update On ASHRAE Society Meetings Daniel Dettmers HVAC&R Center/Industrial Refrigeration Consortium

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Transcription:

Refrigerants REFRIGERANTS Recaimed HCFCs HFCs Ammonia Hydrocarbons Refrigerant repacement tabe Software and accessories Packaging characteristics Refrigerant fuid recovery Ammonia recovery Physico-chemica characteristics of fuids

Cimaife Recommendations Fuids appications Cimate contro / Air conditioning Commercia refrigeration R-134a R-404A R-407C R-410A R-417A (ISCEON MO59) R-422D (ISCEON MO29) R-422A (ISCEON MO79) R-427A (Forane 427A) R-507 ISCEON is a registered trademark of DuPont 8

REFRIGERANTS Industria refrigeration Heat pump / Reversibe cimate contro Liquid chiing Refrigerated transport Refrigerants for retrofit of direct expansion systems running with R-22. 9

Refrigerants Refrigerant gases intended for refrigeration and air conditioning Recaimed HCFCs Definition of recyced product from CE reguation N 1005/2009: The reuse of a recovered controed substance foowing a basic ceaning process. The pacing on the market of recyced HCFCs for free or against payment is prohibited. Definition of recaimed product from CE reguation N 1005/2009: The reprocessing of a recovered controed substance in order to meet equivaent performance of a virgin substance, taking into account its intended use. The pacing on the market of recaimed HCFCs for free or against payment is aowed unti 31 December 2014. Ref. Products Packaging Charge Comments 3962 R-22 T Friopack 10 kg 127 R-22 T Cyinder 52 L 50 kg 7458 R-22 T Drum 448 L 450 kg 138 R-22 T Drum 930 L 950 kg 7454 R-408A T Friopack 10 kg 7455 R-408A T Cyinder 52 L 40 kg 7444 R-409A T Friopack 12 kg Ask us for other package sizes or recaimed HCFCs. Recaiming Service: Cimaife can recaim for its customers, under conditions where a recaimed product wi remain in the customers ownership. The product wi be regenerated in order to have the same performance as a virgin substance and wi then be repackaged. See Services range on page 76. Products, packaging and fi weights may vary by country. Contact your subsidiaries for more detaied information. 7455 Friostar HydroChoroFuoroCarbons: Refrigerant fuids whose sae and use are reguated by European reguation 1005/2009 of 16 September 2009, because they depete the ozone ayer (Montréa Protoco). From 1 January 2010 to 31 December 2014, ony the use of non-virgin HCFCs (recyced or recaimed ) is authorised. R 127 10

REFRIGERANTS HFCs Ref. Products Packaging Charge Comments 257 R-134a Friocatch 14 kg 255 R-134a Friostar 20 kg 251 R-134a Cyinder 52 L 53 kg 3247 R-134a Drum 448 L 460 kg Vertica container. 3249 R-134a Drum 930 L 950 kg 7445 R-227ea Friocatch 14 kg 6731 R-227ea Cyinder 27 L 31 kg 4925 R-227ea Cyinder 52 L 62 kg HFCs (HydroFuoroCarbons): Nonfammabe and non-toxic fuids whose pacing on the market, use, recovery and destruction are restricted by EU reguation 842/2006 (F-Gas). These products do not affect the ozone ayer and are recommended to repace CFCs and HCFCs. 6618 R-236fa Cyinder 12,5 L 10 kg 7259 R-236fa Cyinder 52 L 50 kg 7246 R-404A Cubikoo 10 kg 385 R-404A Friostar 15 kg 7205 R-404A Friopus 18 kg 383 R-404A Cyinder 52 L 40 kg 3781 R-404A Drum 448 L 350 kg Vertica container. 3274 R-404A Drum 930 L 740 kg 7244 R-407C Cubikoo 11 kg 350 R-407C Friostar 18 kg 7245 R-407C Friopus 20 kg 348 R-407C Cyinder 52 L 48 kg 3647 R-407C Drum 448 L 400 kg Vertica container. 4501 R-407C Drum 930 L 840 kg 7242 R-410A Cubikoo 10 kg 6821 R-410A Friostar 16 kg 7243 R-410A Friopus 17 kg 4011 R-410A Cyinder 52 L 40 kg 6617 R-410A Drum 448 L 360 kg Vertica container. 7560 R-437A Friocatch 12 kg Friopus 3663 R-507 Friostar 15 kg 468 R-507 Cyinder 52 L 40 kg 3664 R-507 Drum 930 L 740 kg 7466 R-427A Friocatch 12 kg 7596 R-427A Cyinder 52 L 48 kg 7201 R-427A Container 448 L 430 kg 7202 R-427A Container 930 L 850 kg 5541 R-417A (ISCEON MO59) Friocatch 14 kg 5157 R-417A (ISCEON MO59) Cyinder 52 L 50 kg 7006 R-422D (ISCEON MO29) Cyinder 9,25 L 8 kg 6835 R-422D (ISCEON MO29) Friocatch 12 kg 6832 R-422D (ISCEON MO29) Cyinder 52 L 47 kg 7091 R-422D (ISCEON MO29) Container 448 L 380 kg 6834 R-422D (ISCEON MO29) Container 930 L 840 kg Friocatch 11

Refrigerants Refrigerant gases intended for refrigeration and air conditioning HFCs (continued) References Products Packaging Charge Comments 6842 R-422A (Isceon MO79) Friocatch 12 kg 6839 R-422A (Isceon MO79) Cyinder 52 L 45 kg 7093 R-422A (Isceon MO79) Container 448 L 380 kg 6841 R-422A (Isceon MO79) Container 930 L 818 kg Low temperature appication 7517 Isceon MO89 Friocatch 10 kg 5673 Isceon MO89 Cyinder 52 L 37 kg 4058 R-508B Cyinder 1,34 L 1 kg 4060 R-508B Cyinder 6,7 L 6 kg 4061 R-508B Cyinder 13,4 L 12 kg Ask us. 155 R-23 Cyinder 6,7 L 5 kg 157 R-23 Cyinder 13,4 L 12 kg 160 R-23 Cyinder 50 L 47 kg 7516 FX 80 Friocatch 11 kg 867 Ammonia NH 3 is an L2 (toxic and fammabe) secondary refrigerant fuid. Its transport and use in instaations are governed by reguations and security standards. The product suppied is a high quaity one: quaifying HP 100. Purity: 99,99% weight, water content: 100 ppm weight. 4122 Standard refrigerant Combination of caibrated refrigerants. Compiance certificate. Ammonia References Products Packaging Charge Comments 867 Ammonia Cyinder 88 L 45 kg Without dip tube. 868 Ammonia Cyinder 88 L 45 kg With dip tube. 869 Ammonia Conteneur 930 L 480 kg Hydrocarbons References Products Packaging Charge Comments 155 3602 6732 Propane R-290 Aeroso 390 g To be used with prestovave. 6741 Propane R-290 Cyinder 27 L 10 kg 3602 Isobutane R-600a Aeroso 420 g To be used with prestovave. 6755 Isobutane R-600a Cyinder 27 L 12 kg 1479 Prestovave Box of 2 The ceaning of refrigerant circuits: For interna ceaning, see page 52: Faciisov, GC1. Anaysis in Cimaife Laboratory Cimaife offers a specific anaysis range in order to hep you with the maintenance of your instaations (see on page 68). Products, packaging and fi weights may vary by country. Contact your subsidiaries for more detaied information. 1479 12

REFRIGERANTS Possibe repacement refrigerant according to appications CFCs HCFCs HFCs - NH 3 R-12 R-401A / R-401B R-409A R-22 Air-conditioning appication R-134a R-437A R-134a R-407C R-410A R-417A R-422D R-427A R-22 Refrigeration appication R-134a R-404A / R-507 R-422D R-427A NH 3 R-114 R-124 R-227ea / R-236fa / R-245fa 4068 R-500 R-502 R-13B1 R-13 R-503 R-401B R-409B R-408A R-404A / R-507 R-402A / R-402B R-422A R-403B FX 80 Isceon MO89 R-23 R-508B Software, accessories References Products Packaging Comments 5823 Refrich@rge Cacuates the charge of instaations. 339 Thermofuid Cacuates thermodynamic cyces. 3746 Software programme refrigerant oad osses Cacuates charge oss. 7041 4068 Cimaife refrigerants comparator Piece 6446 Training Kit Piece Incudes 1 bue book, 1 comparator and thermodynamic diagrams. 7041 Bue Handbook Piece Thermodynamic data. 7351 Instaation abes Batch of 25 Labeing required on new equipment by EU reguation 842-2006. 7351 13

Refrigerants Refrigerant gases intended for refrigeration and air conditioning Packaging characteristics Packaging Packaging materia Test pressure Capacity (L) Tare (kg) Diameter (mm) Height (mm) Exit vaves Vave materia Number per paet Cubikoo TM Friopus Lightened stee + Poypropyene Lightened stee + Poypropyene 42 12,5 6 310 x 310 400 Mae 21.8 x 1.814 on right Brass 24 42 22 8,5 305 543 Mae 21.8 x 1.814 on right Brass 16 Friostar Au 31 20 7 300 530 Mae 21.8 x 1.814 on right Brass 11, 16 or 24 Friostar Au 36 20 7 300 530 Mae 21.8 x 1.814 on right Brass Friostar Au 48 20 7,3 300 530 Mae 21.8 x 1.814 on right Brass Cyinder 9,25 L Stee 47 9,25 7,2 245 276 Mae 21.8 x 1.814 on right Brass 14 Cyinder 12 L Stee 47 12,3 7,6 229 505 Mae 21.8 x 1.814 on right Brass 15, 25 or 40 Friopack Stee 29,5 12,5 7 300 310 Mae 1/4 SAE on right Brass 30 or 45 Cyinder 27 L Stee 33 27 14,5 300 625 Mae 21.8 x 1.814 on right Brass 11, 12 or 16 Cyinder 27 L Stee 45 27 16 300 631 Mae 21.8 x 1.814 on right Brass Cyinder 27 L Stee 46,5 27 16 300 606 Mae 21.8 x 1.814 on right Brass Cyinder 52 L Stee 45 52 29,5 267 1195 Mae 21.8 x 1.814 on right Brass 16 Cyinder 88 L Stee 33 88 38 300 1525 Mae 21.8 x 1.814 on right Brass 12 Cyinder 88 L Stee 46,5 88 40 300 1525 Mae 21.8 x 1.814 on right Brass Cyinder NH 3 Stee 46,5 88 40 300 1525 Mae 21.8 x 1.814 on right Stee 12 Drum 448 L Stee 42 448 450 800 1565 Mae 26.1 x 1.814 on right Brass Drum 615 L Stee 42 615 380 800 1600 Mae 26.1 x 1.814 on right Brass Drum 930 L Stee 33 930 440 800 2330 Mae 26.1 x 1.814 on right Brass Drum 930 L Stee 42 930 470 800 2330 Mae 26.1 x 1.814 on right Brass Drum 930 L Stee 48 930 590 800 2330 Mae 26.1 x 1.814 on right Brass Non-contractua information. Products, packaging and fi weights may vary by country. Contact your subsidiary for more detaied information. 14

REFRIGERANTS Refrigerant fuid recovery References Products Packaging Pressure Comments Impementation and use 793 Recovery barre 217 L Packaging designed for haogenated refrigerants to be regenerated or destroyed. 6566 Recovery cyinder 12 L 45 bars For a Low or midde pressure haogenated refrigerants. In Europe, it is compusory to recover CFCs, HCFCs and HFCs from instaations of any weight under European reguation 842-2006 or 1005-2009. These must be returned with appropriate waste documentation as required in each country. R 796 Recovery cyinder 27 L 33 bars For R-22. 6246 Recovery cyinder 27 L 45 bars For a ow or midde pressure haogenated refrigerants. 799 Recovery cyinder 88 L 33 bars For R-22. 6248 Recovery cyinder 88 L 45 bars For a ow or midde pressure haogenated refrigerants. 795 Recovery cyinder 13,4 L 200 bars For high pressure refrigerants: R-13, R-23, R-503. 801 Recovery drum 930 L Our temporary storage (Receiver) cyinders are ceaned and vacuumed to avoid refrigerant contamination. Thus, the refrigerant wi be recharged into the instaation without any contamination probems. 6566 6565 Temporary storage cyinder 12 L 45 bars 750 Temporary storage cyinder 27 L 33 bars 6245 Temporary storage cyinder 27 L 45 bars 752 Temporary storage cyinder 88 L 33 bars 6247 Temporary storage cyinder 88 L 45 bars For temporariy evacuating a system before reintroducing fuids. 754 Temporary storage drum 930 L Ammonia recovery References Products Packaging Impementation and use 757 Ammonia recovery cyinder 88 L 758 Ammonia recovery container 930 L See our services range. Regeneration HCFCs/HFCs 793 Recamation Service: Cimaife can recaim for its customers, under conditions where a recaimed product wi remain in the customers ownership. The product wi be regenerated in order to have the same performance as a virgin substance and wi then be repackaged. See Services range on page 76. 796 15

Refrigerants Refrigerant gases intended for refrigeration and air conditioning HFCs physico chemica properties * Units Forane 23 R-125 R-134a R-152a R-227ea R-236fa R-404A R-407C Composition CHF 3 CHF 2 -CF 3 CH 2 F-CF 3 CH 3 -CHF 2 CF 3 -CHF-CF 3 CF 3 CH 2 CF 3 44% R-125, 52 % R-143a, 4% R-134a 23% R-32, 25% R-125, 52%R-134a Boiing point (under 1,013 bar) C -82-48,09-26,08-24,03-16,35-1,44-46,23-43,63 Temperature gide under 1,013 bar K 0 0 0 0 0 0 0,75 7 Density of iquid at 25 C kg/m 3 680,09 1189,35 1206,71 899,5 1387,67 1359,8 1044 1137,5 Density of saturating vapour at norma boiing point kg/m 3 4,662 6,788 5,257 3,375 8,484 7,14 5,48 4,63 Saturation pressure (Liquid sat.) 25 C bar 49,986 13,78 6,654 5,964 4,55 2,72 12,55 11,9 50 C 25,37 13,18 11,77 9,16 5,84 23,11 22,16 Critica temperature C 26,14 66,02 101,06 113,26 101,75 124,92 72,05 86,03 Critica pressure bar absoute 48,32 36,18 40,59 45,17 29,25 32 37,29 46,29 Critica density kg/m 3 526,5 573,58 511,9 368 594,25 551,29 486,54 484,2 Latent vapourisation heat at norma boiing point kj/kg 239,4 164,11 216,97 329,9 131,77 160,32 200,94 249,8 Specific heat at 25 C Liquid kj/(kg.k) 18,87 1,407 1,425 1,8 1,182 1,26 1,542 1,535 Vapor under 1,013 bar 0,737 0,797 0,8512 1,051 0,813 0,839 0,877 0,837 Cp/Cv ratio at 25 C under 1,013 bar 1,201 1,104 1,119 1,155 1,075 1,083 1,118 1,144 NF-EN 378 cassification L1 L1 L1 L2 L1 L1 L1 L1 ODP (R11 = 1) 0 0 0 0 0 0 0 0 GWP (CO 2 = 1) 14800 3500 1430 124 3220 9810 3220 1774 0 HFCs physico chemica properties * Units R-507 R-508B Forane FX80 Isceon MO89 Composition 50% R-125, 50% R-143a 46% R-23, 54% R-116 32% R-32, 68% R-125 86% R-125, 9% R-218, 5% R-290 Boiing point (under 1,013 bar) C -46,75-87,6-50,9-53,41 Temperature gide under 1,013 bar K 0 0,44 0,21 3,06 Density of iquid at 25 C kg/m 3 1047,9 at -30 C 1234,4 1101,8 1082,5 Density of saturating vapour at norma boiing point kg/m 3 5,585 6,548 4,85 6,507 Saturation pressure (Liquid sat.) 25 C bar 12,83 _ 16,09 15,28 50 C 23,61 _ 29,74 27,52 Critica temperature C 70,62 11,21 69,46 64,18 Critica pressure bar absoute 37,05 37,72 45,55 37,35 Critica density kg/m 3 490,77 568,45 496,92 535,33 Latent vapourisation heat at norma boiing point kj/kg 196,94 165,36 234,38 170,42 Specific heat at 25 C Liquid kj/(kg.k) 1,539 _ 1,613 1,501 Vapor under 1,013 bar 0,87 0,7567 0,814 0,84 Cp/Cv ratio at 25 C under 1,013 bar 1,117 1,136 1,149 1,103 NF-EN 378 cassification L1 L1 L1 L1 ODP (R11 = 1) 0 0 0 0 GWP (CO 2 = 1) 3985 13996 3168 3806 A eements are simuated using Refrop 8 and given purey as an indication. 16

REFRIGERANTS HFCs physico chemica properties * Composition Units R-410A R-413A R-417A R-422A R-422D R-427A R-437A 50% R-32, 50% R-125 9% R-218, 88% R-134a, 3% R-600a 46,6% R-125, 50% R-134a, 3,4% R-600 85,1% R-125, 11,5% R-134a 3,4% R-600a 65,1% R-125, 31,5% R-134a, 3,4% R-600a 50% R-134a, 25% R-125, 15% R-32, 10% R-143a 78,5% R-134a 19,5% R-125 1,4% R-600 0,06% R-601 Boiing point (under 1,013 bar) C -51,45-33,4-39,07-46,5-43,2-46,55-32,33 Temperature gide under 1,013 bar K 0,08 5,33 4,99 2,46 4,86 6,75 4,27 Density of iquid at 25 C kg/m 3 1058,6 1157,8 1151,3 1135,6 1143,44 1124,98 1177,74 Density of saturating vapour at norma boiing point kg/m 3 4,173 5,399 5,685 6,317 5,954 4,78 5,382 Saturation pressure (Liquid sat.) 25 C bar 16,57 7,82 9,83 12,75 11,28 11,43 7,94 50 C 30,71 14,91 18,44 23,42 20,89 21,25 15,26 Critica temperature C 71,35 96,58 87,13 71,72 79,6 85,32 96,26 Critica pressure bar absoute 49 40,22 40,35 37,46 39,05 43,91 40,86 Critica density kg/m 3 459,53 510,87 520,6 538,71 529,14 689,97 512,43 Latent vapourisation heat at norma boiing point kj/kg 272,97 213,12 200,75 177,04 190,05 236,52 213,13 Specific heat at 25 C Liquid kj/(kg.k) 7,708 1,441 1,444 1,446 1,443 1,517 1,436 Vapor under 1,013 bar 0,823 0,871 0,855 0,833 0,844 0,847 0,858 Cp/Cv ratio at 25 C under 1,013 bar 1,176 1,114 1,111 1,105 1,108 1,131 1,116 NF-EN 378 cassification L1 L2 L1 L1 L1 L1 L1 ODP (R11 = 1) 0 0 0 0 0 0 0 GWP (CO 2 = 1) 2088 2054 2347 3144 2730 2138 1805 HCFCs physico chemica properties * Units R-22 R-408A R-409A Composition CHF 2 C 7% R-125, 60% R-22, 46% R-143a, 25% R-124, 47% R-22 15% R-142b Boiing point (under 1,013 bar) C -40,82-44,58-34,45 Temperature gide under 1,013 bar K 0 0,46 8,49 Density of iquid at 25 C kg/m 3 1190,7 1059,5 1213,7 Density of saturating vapour at norma boiing point kg/m 3 4,704 4,83 4,98 Saturation pressure (Liquid sat.) 25 C bar 10,44 11,67 8,02 50 C 19,43 21,47 14,98 Critica temperature C 96,15 83,24 109,26 Critica pressure bar absoute 49,9 42,95 46,99 Critica density kg/m 3 523,8 485,1 508,9 Latent vapourisation heat at norma boiing point kj/kg 233,7 225,78 222,51 Specific heat at 25 C Liquid kj/(kg.k) 1,257 1,448 1,23 Vapor under 1,013 bar 0,662 0,8 0,7095 Cp/Cv ratio at 25 C under 1,013 bar 1,185 1,148 1,151 NF-EN 378 cassification L1 L1 L1 ODP (R11 = 1) 0,055 0,026 0,033 GWP (CO 2 = 1) 1810 2906 1584 Cubikoo TM 17