Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

Similar documents
Understanding Applications for Alternative Refrigerants

Understanding Applications for Alternative Refrigerants

DOE and EPA Impacts to Commercial Refrigeration

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

Refrigerant and Energy Regulations Update

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

REFRIGERANT CHANGEOVER

Refrigerant & Energy Regulations Update

How to Meet 2017/2020 Energy Regulations

BRA FACT FINDER Number 19

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

R-404A Alternative with Low Compressor Discharge Temperature

Low GWP Refrigerants for Air Conditioning Applications

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

SOLSTICE L40X (R-455A)

Making Sense of the Latest Rulemaking on Acceptable Refrigerants. E360 Webinar

2016 Annual Conference

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

R-407A R-448A R-449A

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

Refrigerant changeover guidelines

Gary Parker Refrigerants Product Manager

Honeywell Refrigerants. Retrofit Guidelines. R-404A/R-507A to: R-448A Solstice N40

Gary Parker Refrigerants Product Manager

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

January 16 th, 2014 New York City

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Chillers for High Ambient Conditions: What Technologies and Fluids?

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Refrigerant Glide and Effect on Performances Declaration

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

TEST REPORT #6. Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP)

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Development of centrifugal chiller and heat pump using low GWP refrigerant

The Case for R-290 in U.S. Commercial Foodservice

The Current Path of Refrigerants

Application Engineering

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Honeywell Refrigerant Update

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

TEST REPORT #2. System Drop-in Test of L-40, L-41a and N-40b in Ice Machines

Refrigerant and Energy Regulations Update

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Technical Information

4/19/2013. The Changing State of Refrigerants

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Comparative Performance of HFO Blends in a Condenser

Carwin COMPRESSOR SELECTION PROGRAM

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

Top Retailer Trends for Refrigeration, Controls and Facility Optimization. E360 Webinar March 6, 2018

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

Study of R161 Refrigerant for Residential Airconditioning

Evaluation of HCFC Alternative Refrigerants

R32 Compressor for Air conditioning and Refrigeration applications in China

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Low GWP Refrigerants for Air Conditioning and Chiller Applications

see notes on refrigerant type Refrigerant Type ASHR AE Refrigerant Composition (Mass % ) Zeotropes

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

AIRAH Victoria Refrigerants Update

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

Test Results from the AHRI Low GWP AREP II (Alternative Refrigerant Evaluation Program) Transport Refrigeration

CO 2 transcritical FTE System Full Transcritical Efficiency

System Considerations for Refrigerant Blends with Temperature Glide

PRACTICAL EXPERIENCE WITH AN ALTERNATIVE TO R-22 BASED ON R-32lR /R a. R E Low, B E Gilbert, T W Dekleva.

Refrigerants. Refrigerants with the Future in Mind

GWP Alternative Refrigerants

TEST REPORT #63. Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP)

Commercial CO 2 Refrigeration Systems

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

Scroll Chillers Transition from HCFC-22 to HFCs

AE R21 September 2017

Embraco Position Paper: Light Commercial Refrigeration

New Refrigerants Designation and Safety Classifications

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Flammability and the Low GWP Refrigerant Challenge

The Service Sector Prepares for HFO-1234yf Paul DeGuiseppi MACS Worldwide Mary Koban, DuPont Fluoroproducts

Technical Note. EHPA Quality Label Model Range Definition Version

HFO-1234yf Performance in a Beverage Cooler

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

AE R17 November 2016

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Otherwise, you can continue reading the file on the following pages.

Technical Bulletin (TB-0037)

10/4/2013. The Changing State of Refrigerants

Large AC units using a variety of low-gwp options

Transcription:

Understanding Applications for Alternate Refrigerants Ron Bonear Emerson Climate Technologies

Agenda Overview of R-448A/R-449A Refrigerant Development Methodology Evaluation Strategy R-448A /R-449A Refrigerants Performance Development Thermophysical Comparison of Refrigerants Refrigerant Performance Reliability Evaluation Effect of New Refrigerants on Compressor Components Reliability Assessment R-448A/R-449A Development Summary and Conclusions Brief Update on Alternate Refrigerants R-450A/R-513A and R-452A Update on ECT s Alternate Refrigerant Facilities Development Plan

R-448A/R-449A Refrigerant Evaluation Methodology Alternate Refrigerant Evaluation Performance Focus on Developing Fast/Flexible Refrigerant Release Sidney Refrigeration Engineering Team Developed Test Strategy for Simultaneous Approval of R-448A and R-449A Equivalent Chemical Composition Between the Two Refrigerants Thermophysical Comparison, Miscibility and Compatibility Analysis Performed on R-448A/R-449A

UL Qualification Strategy Objective: Reduce UL Qualification Time Due to Chemical Equivalency of Refrigerants, UL Agreed to Full Model Line Approvals of Both R-448A/R-449A by Testing Only R-448A Testing Required to Show That R-448A MCC Amp Values Were +10% Above R-404A In All Instances, R-448A Met This Criteria The Majority of MCC Values Fall Below That of R-404A As a Result, R-448A Has Been Released Using Existing R-404A MCC Values By Utilizing This Approach, It Was Possible to Significantly Reduce the Total Number of Compressors Tested: 8 Scroll Compressors 6 Semi-Hermetic Compressors (4 Discus / 2 KEL)

R-448A/R-449A Refrigerant Evaluation Methodology Alternate Refrigerant Evaluation Reliability Evaluation of the Interaction of Refrigerants With Oil Miscibility/Solubility/Viscosity Bearing Analysis Performed Using Mobility Analysis Full Operating Envelope and Reliability (CFM) Testing Performed Using R-448A/R-449A

Agenda Overview of R-448A/R-449A Refrigerant Development Methodology Evaluation Strategy R-448A /R-449A Refrigerants Performance Development Thermophysical Comparison of Refrigerants Refrigerant Performance Reliability Evaluation Effect of New Refrigerants on Compressor Components Reliability Assessment R-448A/R-449A Development Summary and Conclusions Brief Update on Alternate Refrigerants R-450A/R-513A and R-452A Update on ECT s Alternate Refrigerant Facilities Development Plan

Evaluation of Alternate Refrigerant Performance Evaluation of R-448A/R-449A Relative to Existing Medium- Pressure Refrigerants Evaluate Equivalency of R-448A Relative to R-449A Evaluate Refrigerant Chemical Compositions Evaluate R-448A Relative to R-404A and R-407A Thermophysical Comparison of Refrigerants Pressure Differential Density Enthalpy Refrigerant Performance Testing Comparison

Evaluation of Refrigerant Chemical Composition R-448A/R-449A Relative Comparison Both R-448A and R-449A are medium-pressure, A1 refrigerants Verify chemical composition ± 5% Honeywell R-448A Composition R-32 (26%) R-125 (26%) R-134a (21%) 1234yf (20%) 1234ze (7%) DuPont R-449A Composition R-32 (24%) R-125 (25%) R-134a (26%) 1234yf (25%) Determination Made That the Two Refrigerants Are Effectively Chemically Equivalent

Evaluation of Refrigerant Pressure Differential Evaluate R-448A P to R-404A/R-407A R-448A exhibits a lower pressure differential than R-404A. R-448A compressor loads will be lower. R-448a and R-407A have essentially identical pressure differentials.

Evaluation of Refrigerant Density Evaluate R-448A Density Relative to R-404A/R-407A

Evaluation of Refrigerant Enthalpy Evaluate R-448A Theoretical Enthalpy Relative to R-404A/R-407A

Scroll MT Mid/Dew Point Capacity R-404A Versus R-407A/R-448A (20/70)

Scroll MT Mid/Dew Point Capacity R-404A Versus R-407A/R-448A (20/120)

Scroll LT Mid/Dew Point Capacity R-404A Versus R-407A/R-448A (-25/70)

Scroll LT Mid/Dew Point Capacity R-404A Versus R-407A/R-448A (-25/105)

Scroll MT Mid/Dew Point Weighted EER R-404A Versus R-407A/R-448A

Scroll LT Mid / Dew Point Weighted EER R-404A Versus R-407A / R-448A

R-448A/R-449A Operating Envelopes Summary and Conclusions Following Operating Envelope Testing and CFM, R-448A/R-449A Will Use Same Envelope as R-407A R-448A/R-449A Demonstrated Thermophysical Equivalence Discharge Line Temperatures Are Similar to But Slightly Higher Than R-407A at HCR/MDP Conditions Reliability Testing Confirms Higher Temperatures at Envelope Corners Are Acceptable» Only Map Affected Is ZBK5 Envelope All R-448A/R-449A Are the Same Envelopes as R-407A Only Exception Is ZBK5 Envelope, With Slightly Reduced HCR Corner Point

Final R-448A/R-449A MT K5 Operating Envelope

Agenda Overview of R-448A/R-449A Refrigerant Development Methodology Evaluation Strategy R-448A /R-449A Refrigerants Performance Development Thermophysical Comparison of Refrigerants Refrigerant Performance Reliability Evaluation Effect of New Refrigerants on Compressor Components Reliability Assessment R-448A/R-449A Development Summary and Conclusions Brief Update on Alternate Refrigerants R-450A/R-513A and R-452A Update on ECT s Alternate Refrigerant Facilities Development Plan

Refrigerant Reliability Evaluation Refrigerant Reliability Assessment Reliability Bearing Analysis Miscibility Solubility/Viscosity Mobility Analysis DFMEA High RPN Failure Modes Drive CFM Test Strategy CFM Testing Summary

Refrigerant Reliability Evaluation Reliability Development Envelope

Miscibility Evaluation

Viscosity Evaluation

Mobility Analysis of R-448A Relative to R-404A

R-448A/R-449A CFM Summary Evaluated Full Range of Compressors Using Standard Reliability Engineering Procedure Performed CFM Testing at Envelope Corner Points HCR MDP High Load Flooded Start and Defrost Cycles Tested to Verify Miscibility Ensure Full Hydrodynamic Bearing Film Thickness Following Refrigerant Washout Mobility Used to Validate Minimum Oil Film Thickness to Surface Finish Ratio (ʎ) R-448A/R-449A Meets or Exceeds ʎ for R-404A All Scroll/Semi-Hermetic Compressors Passed Full Battery of CFM Testing

Agenda Overview of R-448A/R-449A Refrigerant Development Methodology Evaluation Strategy R-448A /R-449A Refrigerants Performance Development Thermophysical Comparison of Refrigerants Refrigerant Performance Reliability Evaluation Effect of New Refrigerants on Compressor Components Reliability Assessment R-448A/R-449A Development Summary and Conclusions Brief Update on Alternate Refrigerants R-450A/R-513A and R-452A Update on ECT s Alternate Refrigerant Facilities Development Plan

R-448A/R-449A Summary and Conclusions From R-448A/R-449A Qualification, the Sidney Refrigeration Engineering Team Has Utilized a Standardized Test Strategy for New Refrigerants - Comparative Evaluation of Refrigerant Properties - Full UL, Performance, Operating Maps and Reliability Testing Thermophysical Similarity of R-448A and R-449A Has Been Verified The Thermophysical Properties of R-448A Are Much Closer to R-407A Than R-404A - R-404A Is Much Denser Than R-448A; Higher Mass Flows - R-448A Exhibits Lower P; Lower Bearing Loading Than R-404A - R-404A Capacity Significantly Greater Than R-448A at LT Conditions, Roughly Equivalent on MT Applications

R-448A/R-449A Summary and Conclusions R-448A/R-449A Operating Envelopes Are Equivalent to Current R-407A - Ref ZB*K5 HCR Condensing Will Be Slightly Reduced to Accommodate R-448A/R-449A and R407A on One Map Bearing Analysis Performed by Evaluating Miscibility/Viscosity, Loads, M Mobility Analysis and CFM Comprehensive R-448A/R-449A Performance and Reliability Evaluation Complete Captured Lessons Learned in Standardized Document - Utilized for All New Refrigerant Releases Accuracy and Completeness of Data for Both Performance and Reliability Are Assured

Agenda Overview of R-448A/R-449A Refrigerant Development Methodology Evaluation Strategy R-448A /R-449A Refrigerants Performance Development Thermophysical Comparison of Refrigerants Refrigerant Performance Reliability Evaluation Effect of New Refrigerants on Compressor Components Reliability Assessment R-448A/R-449A Development Summary and Conclusions Brief Update on Alternate Refrigerants R-450A/R-513A and R-452A Update on ECT s Alternate Refrigerant Facilities Development Plan

Update on R-513A/R-450A and R-452A Performance and Initial Reliability Evaluations Underway for Low- Pressure R-513A/R-450A (Europe and U.S.) and for Medium-Pressure R-452A (U.S., Transport Scroll Only) Preliminary Performance Evaluation for Refrigerants Complete Initial Reliability Assessments of Both R-452A and R-513A Indicate Higher Solubility Index May Pose Challenge for Compressor Boundary Lubrication Higher Solubility Reduces Oil Viscosity and May Affect Boundary Lubrication During Liquid Applications Currently Evaluating Alternate, Higher Viscosity Oil as Countermeasure

R-450A/R-513A Refrigerant Performance Capacity

R-450A/R-513A Refrigerant Performance EER

R-452A Refrigerant Performance Capacity

R-452A Refrigerant Performance EER

Agenda Overview of R-448A/R-449A Refrigerant Development Methodology Evaluation Strategy R-448A /R-449A Refrigerants Performance Development Thermophysical Comparison of Refrigerants Refrigerant Performance Reliability Evaluation Effect of New Refrigerants on Compressor Components Reliability Assessment R-448A/R-449A Development Summary and Conclusions Brief Update on Alternate Refrigerants R-450A/R-513A and R-452A Update on ECT s Alternate Refrigerant Facilities Development Plan

Recap of Alternatives for Refrigeration Applications Pressure Building or Capacity CO 2 R-410A Like R-404A and R-407/22 Like 1 NH 3 R290 <150 2016 R-446A, R-447A, ARM-71a R-32/HFO 400 675 R32 Blends ~300 HDR110 DR3 ARM-20a A1 Non-Flammable A2L Mildly Flammable 4 R-444B = L20 L40, DR7 ARM-20b R-32/HFO Blends A3 Flammable B2L Toxic, Mildly Flam. R-448A = N40 R-449A = DR33 R-449B = ARM-32 N20 < 1,500 R-32/HFC/HFO Blends 3 2015 R-410A R-22 R-407A R-407C R-407F, R-452A = XP44 AR M-35 Qualitative Not to Scale 2 R-404A R-507A (3922) R-134a Like R-123 Like (V. Low Pr.) HFO 1234yf HFO 1234ze ARM-42 DR2, N12, ARC 1 HFC/HFO R-450A = N13 ~600 Blends R-513A = XP10 R134a 0 500 1,000 1,500 2,000 GWP Level

Emerson s A3 / A2L Facilities Development Plan

Emerson s A3 / A2L Facilities Development Plan

Emerson s A3 / A2L Facilities Development Plan

Selecting a TXV for Use With R-448A / R-449A / R-513A Brad Hopson Emerson Climate Technologies

Selecting a TXV for Use With R-448A / R-449A / R-513A Brad Hopson Emerson Climate Technologies

TXV Selection Review 1. Refrigeration Type 2. Evaporator Temperature/Pressure 3. Evaporator Capacity 4. Condensing Temperature/Pressure 5. Liquid Temperature 6. Distributor Type (if used) Note: The valve is sized to the evaporator and not the compressor.

Glide and the p-h Diagram Zeotropic Blends Exhibit Glide Calculating Delta P at Expansion Device: Bubble Point (Saturated Liquid) for Condensing Pressure Dew Point (Saturated Vapor) for Evaporating Pressure

TXV Pressure Differential This Is Also the Delta P at the Expansion Device Lower Delta P Generally Lowers Valve Capacity In the Given Applications, the Change in Pressure Differential Is Very Small

Superheat Superheat Curves (and Other Secrets) Evaporator Temp. R-404A Bulb Charges Are NOT Optimized for R-448/449 Superheat Settings MUST Be Adjusted At Low Temps, the Superheat Tends to Rise

Low-Temp. Valve Capacity Adjustment Low-Temp. Applications Require Larger Valves In Practice, Choose a Valve With 50% More Capacity

Summary Pressure Differential: Use Bubble Point for Condensing Pressure Use Dew Point for Evaporating Pressure R-513A Use R-134A Tables R-448A/R-449A Medium-Temp Very Similar to R-404A Low-Temp Select Approximately 50% More Capacity

Thank You! Questions? DISCLAIMER Although all statements and information contained herein are believed to be accurate and reliable, they are presented without guarantee or warranty of any kind, expressed or implied. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and the user assumes all risks and liability for use of the information and results obtained. Statements or suggestions concerning the use of materials and processes are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patents. The user should not assume that all toxicity data and safety measures are indicated herein or that other measures may not be required.