Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Similar documents
Grow your business: Get ready for flammable refrigerants!

Meeting the Challenges of the EU HFC Phase-Down

International New Technology and Refrigerant Symposium

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

The impact of legislation and trends for the industry

Retrofitting Existing Systems

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

Legislation & Standards

The Current Path of Refrigerants

Natural refrigerant trends in EU, Japan & North America

Low GWP alternative refrigerants to R404A

Effectively Managing the Transition to Lower GWP Refrigerants

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Overview of New Refrigerants and Expected Market Trends

Refrigerants & Cooling in renovation buildings

New Refrigerants & Selecting Capital Equipment

Flammability and the Low GWP Refrigerant Challenge

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

HFO-1234yf Performance in a Beverage Cooler

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Update on Opteon Refrigerants

FACT SHEET 6 Transport Refrigeration

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Refrigerant and Energy Regulations Update

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Understanding Applications for Alternative Refrigerants

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

AIRAH Victoria Refrigerants Update

Understanding Applications for Alternative Refrigerants

market trend update on industrial & light-commercial refrigeration

March 2014 AHRI Presents Research Findings at Low-GWP AREP Conference

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Navigating a changing refrigerants market

Making equipment decisions

Gary Parker Refrigerants Product Manager

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

Embraco Position Paper: Light Commercial Refrigeration

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Flammability and New Refrigerant Options

natural refrigerants - global trends & developments

Sanhua accepts the challenge of new low-gwp refrigerants

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Information Guide Maintenance and Refrigerant Regulations. Issue 35

HFCs or the Old Refrigerants - what is the best Choice?

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

The Industry s Most Complete Refrigeration Source

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

An Industry Prepares Service Technicians for Refrigerant Transition

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

Guidance for Stationary Refrigeration & Air-Conditioning

Japanese market and issue of Heat Pump Kenji Matsuda

The link between safety standards and legislation:

Be sustainable while protecting your business

DOE and EPA Impacts to Commercial Refrigeration

Effectively Managing the Transition to Lower GWP Refrigerants

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Low GWP Refrigerants for Air Conditioning Applications

Alternative Refrigerants Part 1 Future and Current Options. Overview

Gary Parker Refrigerants Product Manager

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Training and certification experience in Europe and opportunities in Hot Countries Tunis, 25th October 2016

The natural solution for domestic refrigeration

Overview of refrigerant alternatives in the air conditioning sector *

Large AC units using a variety of low-gwp options

Brazed Plate Heat Exchanger for CO Applications

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Update on Codes and Standards Research. Karim Amrane, Ph.D. Senior Vice President

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Chillers for High Ambient Conditions: What Technologies and Fluids?

GUIDE TO THE F-GAS REGULATION (EC 517/2014)

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

Refrigerant options now and in the future

Chapter 2. Alternatives to HCFCs and their Characteristics

world natural refrigerants trends market availability, technology trends & the impact of policy

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

CO 2 transcritical FTE System Full Transcritical Efficiency

R-407A R-448A R-449A

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

The Case for R-290 in U.S. Commercial Foodservice

Honeywell Refrigerant Update

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

New Refrigerants Designation and Safety Classifications

This presentation is posted for public use. ACEEE does not endorse any product or service.

Refrigerant & Energy Regulations Update

4/19/2013. The Changing State of Refrigerants

Refrigerants for residential and commercial air conditioning applications

Refrigerant options now and in the future

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Transcription:

Stay in business: R-507A R-404A STOP installing R-404A / R-507A!

WHY IS IT URGENT TO ACT? The massive HFC phase-down step in 2018 and the Global Warming Potential (GWP) limit of 2500 in 2020 do not leave you any choice: If you want to stay in business, you have to stop installing R-404A / R-507A - NOW! R-404A R-507A From 2018 onwards, the EU F-Gas Regulation (EU 517/2014) creates massive cuts in the available quantities of HFCs in the EU. Million tonnes CO 2 equivalent 200 150 100 50 0 Baseline 2018 2021 EU HFC Quota Pre-charged imports This reduction scheme, known as the HFC phasedown, is based on a quota system. Quota are expressed in CO 2 equivalent. 2

C0 2 equivalent The higher the Global Warming Potential of an HFC, the higher the quantity of CO 2 -equivalent 1 kg of refrigerant represents. 1 kg R-134a 5000 4000 3000 2000 1000 0 1 kg R-404A 5000 4000 3000 2000 1000 0 Therefore, the HFC phase-down hits HFCs with a high GWP, such as R-404A and R-507A, hardest; and if the consumption of these HFCs does not go down rapidly, all other HFCs, including blends containing HFCs, will suffer as a result. Pure HFOs, CO 2, hydrocarbons, ammonia, reclaimed or recycled HFCs etc. do not fall under the phase-down Additional to the huge HFC phase-down steps in 2018 and 2021, the EU F-Gas Regulation bans the use of HFCs with a GWP >_ 2500 from 2020 in new refrigeration equipment and also for service and maintenance in refrigeration equipment with a charge size of 40T of CO 2 -equivalent or more (= approx. 10 kg of R-404A / R-507A). Only exception: recycled and reclaimed HFCs even with a GWP > 2500 - can still be used for service until 2030 From 2022, HFCs with a GWP >_ 150 will be banned in new commercial, centralized, multipack refrigeration systems >_ 40 kw (except certain cascade types) and in stand-alone commercial refrigerators and commercial freezers. 3

WHAT ARE THE MAIN RISKS IF NO ACTION IS TAKEN? Impact on prices: A survey of the European Commission shows dramatic HFC price increases since the beginning of 2017 and expects this trend to continue. Prices for R-404A have increased by >500% since January 2017 R-404A 100 % 500 % Immediate shortage or even unavailability of high GWP HFCs such as R-404A and R-507A but also of other HFC containing refrigerants, if no actions are taken on R-404A and R-507A. WHAT CAN YOU DO? Don t wait, act now! > Stop using R-404A / R-507A in new equipment > Retrofit existing equipment from R-404A / R-507A to lower GWP refrigerants when systems are prone to leakage and/or other failures > Reduce leakages > Reduce the refrigerant quantity per system as much as possible > Recover, recycle and reclaim refrigerants The higher the GWP of the refrigerant, the more it will come under pressure by the HFC phase-down, leading to likely price increases and potential shortages. 4

WHAT ARE THE ALTERNATIVES FOR SYSTEMS WITH R-404A / R-507A? Numerous alternatives exist to replace R-404A and R-507A in new and in existing systems. However, properties such as volumetric refrigerating capacity, pressure level, flammability, toxicity, etc. of the alternatives may differ significantly from their predecessors. Therefore, it is always important to check availability of components and compressor manufacturer approval. Safety is more important than ever as many of the R- 404A and R-507A alternatives are flammable. Category A3 A2 A2L A1 WHAT does that mean? Classification Highly flammable Flammable Mildly flammable Non-flammable Many alternatives are currently under development and will become commercially available at a later stage. This leaflet will therefore be regularly updated and installers are invited to contact their suppliers for the latest information. A main difference between the categories is the lower flammability limit (LFL) of the refrigerant. For example, with an A3 gas such as R-290, the LFL (in kg/m3) is nearly 8 times lower than with an A2L gas. Another difference is the burning velocity which is much lower with A2L gases than with A3. In practical terms it means that for example in occupied spaces far higher charge sizes are possible with A2L refrigerants than with A3. Always check relevant standards, building codes and the installation instructions from manufacturers when using flammable refrigerants. 5

WHAT REFRIGERANT TO USE IN NEW SYSTEMS? Does your customer want a new system? Is the existing system too old to be retrofitted and/or in bad shape? >Then a new system needs to be installed Always ensure the safe and energy efficient operation of the system. APPLICATION Multipack centralized refrigeration systems for commercial use with a rated capacity of 40 kw or more GWP<150 GWP<1500 Medium and low temperature, direct expansion Primary refrigerant circuit (MT) of cascades Primary refrigerant circuit (LT) of cascades R-744 (CO 2 ) R-290 R-1270 R-454C R-455A R-744 (CO 2 ) R-1234yf R-1234ze(E) R-290 R-1270 R-744 (CO 2 ) R-454C R-455A R-32 R-134a R-407H R-448A R-449A R-450A R-513A R-515A 6 Flammable (A3) Mildly flammable (A2L) Non flammable (A1)

APPLICATION Commercial refrigerators and freezers GWP<150 Medium temperature Low temperature R-290 R-1270 R-454C R-455A R-744 (CO 2 ) R-1234yf R-1234ze(E) R-290 R-1270 R-744 (CO 2 ) R-454C R-455A APPLICATION Condensing units and multipacks with a rated capacity below 40kW GWP<150 GWP <1500 GWP<2500 Medium & low temperature R-454C R-455A R-744 (CO 2 ) R-32 R-134a R-407H R-448A R-449A R-454A R-454B R-407A R-407F R-410A R-452A Flammable (A3) Mildly flammable (A2L) Non flammable (A1) 7

WHEN TO DO A RETROFIT AND WHAT REFRIGERANT TO USE? Your system is prone to leakage and/or other failures but has not yet arrived at the end of its useful lifetime? Your customer does not want to invest into a new system yet? >Then you should consider a retrofit Always ensure that refrigerants are recovered for reclaim when carrying out retrofits. Criteria to be considered when selecting a refrigerant for retrofit of an existing R-404A / R-507A system The capacity must not be substantially lower than with the original refrigerant The pressure level must not be substantially higher Mildly flammable, flammable and highly toxic refrigerants are not suitable for retrofits of existing systems Discharge temperature, refrigerant mass flow, pressure / temperature relation, compatibility with oils and elastomers etc. differ in most of the cases from R-404A / R-507A. Always check with the supplier of components, especially compressors, for approval and reliable operation. GWP < 1500 GWP < 2500 R-448A, R-449A, R-407H R-407A, R-407F, R-452A Medium and Low Temperature Non flammable (A1) 8

A WORD ABOUT REFRIGERANT RECOVERY Refrigerants recycled and reclaimed in the EU do not fall under the HFC phase-down. Therefore, they can ease the pressure of the phase-down by providing additional refrigerant quantities to the market. Make sure you do not miss that opportunity! From 2030, the use of recycled and reclaimed refrigerants with a GWP>2500 will be banned in refrigeration equipment with a charge size of 40T of CO 2 -equivalent or more (= approx. 10 kg of R-404A / R-507A). Recover and reclaim the refrigerants at the end of lifetime or when retrofitting systems so that they can be used again in a safe way. Venting refrigerant is forbidden under the F-Gas Regulation and subject to fines 9

act now...... and stop installing R-404A / R-507A! Choosing the right refrigerant is crucial for your business to survive and to grow. R-404A R-507A That s why the European industry associations AREA, ASERCOM, EFCTC and EPEE have joined forces to alert the market and to communicate together on the urgency to step out of R-404A / R-507A.

AREA is the European association of refrigeration, air conditioning and heat pump contractors. Established in 1989, AREA voices the interests of 25 national associations from 22 countries representing 13,000 companies employing 110,000 people and with an annual turnover approaching 23 billion. www.area-eur.be ASERCOM, the Association of European Component Manufacturers is the platform for dealing with scientific and technical topics and their challenges, promoting standards for performance rating, methods of testing and product safety, focusing on improved environmental protection, serving the refrigeration and air conditioning industry and its customers. www.asercom.org Representing the European Fluorocarbons and Sulphur Hexafluoride Manufactures. www.fluorocarbons.org The European Partnership for Energy and the Environment (EPEE) represents the interests of the refrigeration, air-conditioning and heat pump industry in Europe. Founded in the year 2000, EPEE s membership is composed of 47 member companies, national and international associations from Europe, the USA and Asia, employing more than 200,000 people in Europe and realising a turnover of over 30 billion Euro. www.epeeglobal.org 11

Version 01 February 2018