The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Similar documents
PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

The Current Path of Refrigerants

New Refrigerants & Selecting Capital Equipment

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager

Flammability and the Low GWP Refrigerant Challenge

Update on Opteon Refrigerants

R-404A Alternative with Low Compressor Discharge Temperature

Refrigerant and Energy Regulations Update

International New Technology and Refrigerant Symposium

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

AIRAH Victoria Refrigerants Update

Natural Refrigerants.

Understanding Applications for Alternative Refrigerants

Understanding Applications for Alternative Refrigerants

Meeting the Challenges of the EU HFC Phase-Down

Refrigerants & Cooling in renovation buildings

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

HFO-1234yf Performance in a Beverage Cooler

Retrofitting Existing Systems

Chapter 2. Alternatives to HCFCs and their Characteristics

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Low GWP alternative refrigerants to R404A

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

4/19/2013. The Changing State of Refrigerants

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Making Sense of the Latest Rulemaking on Acceptable Refrigerants. E360 Webinar

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

REFRIGERANT REPORT 20 A EN

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

CO 2 transcritical FTE System Full Transcritical Efficiency

Frequency Inverters to save energy. ASERCOM EPEE Symposium. John P. Gibson ASERCOM WG Inverter. Nuremberg,

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Overview of New Refrigerants and Expected Market Trends

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Commercial CO 2 Refrigeration Systems

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Effectively Managing the Transition to Lower GWP Refrigerants

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

REFRIGERANT CHANGEOVER

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

Honeywell Refrigerant Update

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

DOE and EPA Impacts to Commercial Refrigeration

R-407A R-448A R-449A

Chillers for High Ambient Conditions: What Technologies and Fluids?

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

HFCs or the Old Refrigerants - what is the best Choice?

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Refrigerants and lubricants

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Alternative Refrigerants Part 1 Future and Current Options. Overview

March 10, 2016 San Joaquin Valley RETA Meeting

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

FACT SHEET 6 Transport Refrigeration

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

Refrigerant & Energy Regulations Update

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Low GWP Refrigerants for Air Conditioning Applications

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Trends and Perspectives in Supermarket Refrigeration

Legislation & Standards

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

New Refrigerants Designation and Safety Classifications

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

Thermodynamics I. Refrigeration and Heat Pump Cycles

Test Results from the AHRI Low GWP AREP II (Alternative Refrigerant Evaluation Program) Transport Refrigeration

Magnetic Refrigeration. Study Case

Reducing Refrigerant Leakage

DuPont ISCEON 9 Series Refrigerants

Framtidens köldmedier

A refrigeration system for supermarkets using natural refrigerant CO 2

Embraco Position Paper: Light Commercial Refrigeration

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR AC AND REFRIGERATION

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

CHAPTER 1 INTRODUCTION

COMPARATIVE STUDY OF NEW ECOLOGICAL GASES

10/4/2013. The Changing State of Refrigerants

Scroll Chillers Transition from HCFC-22 to HFCs

Transcription:

Opteon Refrigerants The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard Mark Hughes Business Development Manager Opteon Refrigerants

Agenda Intro Chemours The Chemical Company F Gas Regulations and Market Consequences The size of the problem and possible solutions Opteon solutions - A1 commercial HFO blends Opteon XP40 - Results and market progress Why the Industry standard? March 2, 2016 2

A start-up with more than 200 years of experiences More than 6000 Employees Serving over 5000 customers in 130 countries Excellent portfolio, divided into TiO 2, Fluoroproducts and Chemical Solutions

F-Gas regulation and it s market consequences March 2, 2016 4

New Equipment Service Bans HFC Phasedown The Three Pillars Of F-Gas II F-Gas II - (EU) 517/ 2014

EU-Regulation(EU) 517/ 2014 Service Ban (Control of use in article 13 (3)) Jan 2020 STOP of HFC and HFC-containing (GWP>2500) above 40t of CO2-e (e.g. >10,2kg R404A); means Supermarkets, industrial Refrigeration, larger food stores, etc. Exceptions: a. Military Equipment b. Applications with product temp <-50 C, e.g. R23/ R508 c. Recycled/ Reclaimed HFCs with GWP>2500 is allowed until end of 2029

EU F-Gas II: Drivers for Low GWP Precharge Volume = required CO 2 -equivalents for precharged equipment (ca. 12 %) Precharge Volume Precharge Volume Pre-charge impact Precharge Volume Cap reduction impact Drivers for low GWP 404A replacements: Cap/reduction supply & price pressures on 404A GWP limits ban 404A GWP (AR4) 404A 3922 GWP Limits GWP Limit GWP Limit 407A 2107 New 2500 Service 2500 > 10kg 404A New centralized >40kW 150 New centralized >40kW Primary of cascade 1500 407F 1825 134a 1430 XP40 1397

The potential solutions (1) Not-In-Kind refrigerants Many large end users have a program for new install A lot of noise in the market but what are the facts? Must play a part but the drawbacks limit speed and spread of implementation 8

Can 100% of the market go to naturals to meet the cap? Natural refrigerants xx Use constraints CO 2 New systems only. Retrofit not possible (high pressure). Inefficient in high ambient climates. hydrocarbons ammonia Theoretically YES.practically NO! Naturals not possible/practical for retrofit, top-up of installed systems. Naturals have constraints for range of new equipment use safety, cost, codes/standards. Limited industry capacity & skilled contractors for installed base replacement with Natural equipment. New systems only. Very small charge size only; retrofit not allowed (highly flammable; codes/standards). New systems only; retrofit not allowed (flammable, toxicity, codes/standards). Non-public areas. Market Use Good choice for supermarket low T in cascade with HFC for med T use growing in EU. 100% CO2 systems only practical in N.EU. Common choice for hermetically sealed small refrigeration/freezing equipment. Growing use for some low T freezing in discount supermarkets in EU. Common for industrial refrigeration. Lower GWP HFO blends Confidentialrequired to meet the CAP

Carbon Dioxide Equivalent Emissions Energy Efficiency will be the major Environmental Concern Loss of 10% in Energy Efficiency=Loss of all benefits of eliminating HFCs 100 If Energy Efficiency Decreases by 10% 80 60 40 If Energy Efficiency is Maintained 20 0 2010 Intended Effect of Phasedown by 2030 Refrigerant Energy Phasedown but with - 10% Energy Efficiency 2030 Source: EPEE Bangkok presentation 27.06.2013

The potential solutions (2) Lower GWP HFCs 407A/407F are offered for retrofit or new install Large marketing effort has influenced uptake Proven energy savings versus R-404A Lower GWP than R-404A 407F has issues with high discharge temperature GWP level means likely to have to replace in future Only an interim solution

How will the market change by 2030? 12

Prognosis for Commercial Sector into 2030 HFC/ HFO-Refrigerants in Commercial Refrigeration 70 68 Mill t 60 50 40 30 20 19kt 15,5kt 11,1 Mill t 2010 2030 10 0 Vol. [ kt ] CO2-eq [ Mill t CO2-eq ] Criteria: Retail vs. Cond. units is 50%-50%; refrigerant decrease of 0,5%/ year

GWP (AR4) Sustainability of F Gases in EU 4500 2015 4000 3500 R404A/ 507 3000 2500 2000 R407A/F ISCEON MO29 R410A ~ 2000 GWP R407C 1500 Opteon XP40 R134a 1000 R32 Opteon XP10 500 Recycled HFO 0-10 0 Others 10 20 30 40 50 60 70-500 CO 2 Equivalent (Million tonnes)

GWP (AR4) Sustainability of F Gases in EU 4500 2030 * 4000 3500 3000 2500 2000 R407A/F ~ 2000 GWP R407C 1500 R134a Opteon XP40 1000 500 Other HFO Opteon XP10 B250 Opteon XL41 R32 0 Recycled -10 0 10 20 30 40 50 60 70-500 CO 2 Equivalent (Million tonnes) * SKM Enviros & DuPont assuming the quantity of refrigerant used remains constant

GWP (AR4) Sustainability of F Gases in EU 2500 2030 2000 R407A/F ~ 2000 GWP R407C Opteon XP40 1500 R134a 1000 Opteon XP10 R32-80 % 500 ~ 400 GWP Others HFO Opteon XL40 & Opteon XL20 Opteon XL41 0 Recycled -5 0 5 10 15 20-500 CO 2 Equivalent (Million tonnes)

Volume as a percentage of 2015 HFC/HFO Volume Relative Volumes (Tonnes Product) represented as a Percentage of the 2015 HFC/HFO Volume 100% HFC/HFO Reclaim Other 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 2015 2030 17

The Immediate Problem (1) Large banks of installed R-404A/R-507A Equipment still being installed on R-404A R-404A is today still a cheap option and widely used The market does not understand what is coming Inertia from end users and contractors EU wide Confusion in the market - R-???

The Immediate Problem (2) Excerpt from EPEE Gapometer project

Which new Alternative Refrigerants are already available Today? March 2, 2016 20

Refrigerant Selection Best Balance of Properties for each Application Non-FGas are best sometimes; not always. HFOs are necessary for cost-effective, safe transition. Zero-ODP, Low-GWP, Favorable LCCP Favorable Toxicity No or Low Flammability Safety and Sustainability System Energy Efficiency + Capacity Performance Cost to Use First Cost + Operating = Total Cost to Use ** ** Impacted by maturity of technology Timing of Commercial Availability NOW

Low GWP Options - HFOs CFC HCFC HFC HFO Chloro-Fluoro-Carbon Hydro-Chloro-Fluoro-Carbon Hydro-Fluoro-Carbon Hydro-Fluoro-Olefin HFO-1234yf CF 3 CF=CH 2 Unique properties: Stable in operating system Not stable in atmosphere = low GWP Efficient performance

A long term solution HFO blends why? GWPs low enough to be maintained under the cap A range of products for different applications Formulated to give best balance of properties Can use in existing equipment Easier to handle than Not-In-Kind refrigerants Opteon Refrigerants The Future is Clear

Opteon Refrigerants Refrigerant Opteon XP10 (R-513A) Opteon XP40 (R-449A) GWP* 631 (573) 1397 (1282) Flammability Class (ASHRAE)** Commercially Available 1 YES 1 YES Application Area Refrigeration & AC replacing R134a in DX and flooded systems Medium & Low Temperature Refrigeration Opteon XP44 (R-452A) Opteon YF (R-1234yf) Opteon XL20 (R454C***, DR-3) Opteon XL40 (R-454A, DR-7) Opteon XL41 (R-454B, DR-5A) Opteon XL55 (R-452B***, DR-55) 2141 (1945) 4 (1) 148 (146) 239 (238) 466 (467) 698 (676) 1 YES 2L YES 2L Planned 2016 2L Planned 2016 Transport Refrigeration and small LT hermetics Automotive AC & Small Charge Refrigeration Small Hermetic Medium and Low Temperature Refrigeration Small non-hermetic Medium and Low Temperature Refrigeration 2L Planned 2016 AC Replacement for R-410A 2L Planned 2016 AC Replacement for R-410A (Preferred R-410A replacement for Trane) *Intergovernmental Panel for Climate Change (IPCC) Assessment Report 4 (AR4) values used for EU F-Gas Legislation. IPCC Assessment Report 5 (AR5) values given in brackets for comparison. **ASHRAE Flammability class 2L must be used in accordance with the current codes and standards e.g. EN-378. *** Preliminary assignment and classification

Alternative Refrigerants commercially available today R134a Alternative March 2, 2016 25

Opteon XP10 Replaces R134a ASHRAE #: R-513A HFC/HFO blend: R1234yf / R134a (56% / 44%) ODP: Zero Ozone Depletion Potential GWP: 631 (AR4) ASHRAE safety: A1 non-flammable Glide: 0K (Azeotrope) Can be topped off while servicing (do not mix with R-134a) Compatible with POE lubricants Compressor approvals: Bitzer, Emerson, many others in progress

Opteon XP10 Competitive Benchmark Calculations using Bitzer Software (v.6.4.3 rev1302) in 4FES-3Y Reciprocating compressor, at 40ºC Condensing Temperature Opteon XP10 R134a R450A Capacity + 23 % C.O.P. 27

Opteon XP10 Evaluation in Supermarket Hybrid System Retrofitted from R-134a Medium Temp; CO 2 in Low Temp Running for >three years 28

Opteon XP10 Approved by Trane Trane Announced the use of Opteon XP10 for EcoWise Chillers in January 2015

Opteon XP10 Approved by York Centrifugal and Screw Chillers 30

Alternative Refrigerants commercially available today R404A Alternatives March 2, 2016 31

Opteon XP40 Replaces R404A ASHRAE #: R-449A HFC/HFO blend: R32 / R125 / R1234yf / R134a (24.3%/24.7%/25.3%/25.7%) ODP: Zero Ozone Depletion Potential GWP: 1397 (AR4) ASHRAE safety: A1 non-flammable Glide: ~4-5K Can be topped off while servicing (do not mix with R-404A) Compatible with POE lubricants Compressor approvals: Bitzer, Emerson, Frascold, Dorin

Ahold, Marum, Netherlands Retrofit from R407F to Opteon XP40 R-407F Base Data gathered from July to November 2013 Opteon XP40 Data Measured from November 2013 until June 2014 Medium (100 kw) and Low temperature (14 kw) Racks Monitored Copeland Compressors (MT = 1x D4DH-250 50-100% & 2x D4DA-200x, LT = 1x D3DC-100 & 2x D3DA-75X Danfoss ADAP-Kool Controller and electronic expansion valves 3/2/2016 33

Medium Temperature Power Consumption vs Outside Temperature T outside (ºC) Power consumption of Opteon XP40 vs R407F 13-0.4% 18-7.5% 24-11.4% 34

Low Temperature Power Consumption vs Outside Temperature T outside (ºC) Power consumption of Opteon XP40 vs R407F 10-3.4% 15-5.5% 20-5.5% 35

LT Maximum Compressor Discharge vs Outside Temperature T outside (ºC) T discharge of Opteon XP40 vs R407F 10-7.5 K 15-7.9 K 20-8.2 K 36

Italian Supermarket Medium Temp Cascaded with LT CO 2 Cabinet & Expansion Valve Models Compressor Models (Bitzer Screw) Compressor Model Quantity Range Capacity / W 1 HSK 6451-50 1 15/ +45 C 83200 2 HSK 6451-50 1 15 /+45 C 83200 3 HSK 6451-50 1 15 /+45 C 83200 4 HSK 6451-50 1 15 /+45 C 83200 5 HSK 6451-50 1 15 /+45 C 83200 6 HSK 7471-90 1 15 /+45 C 105500 Total Capacity / W 521500 Margin relative to requirement / W 57412 (11,01%) 37

System Measurements Daily Average Temperature of 28ºC 38

Energy Comparison Daily Power vs Daily Ambient Temperature -9% 39

Belgian Supermarket Retrofit 2 Medium Temperature (MT) Racks each with 2 Bitzer 4J-22.2Y (35kW) compressors. Rack A has an expected maximum load of 46kW and Rack B an expected maximum load of 73kW. The Low Temperature (LT) rack (Rack D) has 3 Bitzer 4NCS-12.2Y (8.63 kw) compressors with cooling fans fitted and an expected maximum load of 24kW. 47 cabinets (35 MT and 12 LT) with 10 cold rooms (8MT, 2LT) operating on the racks. All the cabinets and cold rooms use Danfoss (TE) thermostatic expansion valves. 40

Medium Temperature System 19ºC Average Daily Temperature 41

Low Temperature System 19ºC Average Daily Temperature 42

Daily & Cumulative Power Consumption for Days with Similar Temperatures Click to edit Master title style

Working with GEA Refrigeration Industrial applications replacing R-404A and R-507 March 2, 2016 44

New installation CoOp convenience stores Opteon XP40 chosen for new stores in Lincoln CoOp One third the GWP of R-404A Lower GWP than interims such as R-407A/F Chosen as a long term solution for equipment lifetime Finalist Environmental Project of the Year ACR News Awards 2016 March 2, 2016 45

UK Supermarket Retrofits/Refits Watch this space! March 2, 2016 46

Opteon XP40 Approvals Opteon XP40 (R-449A) Approvals, Many More Soon

Opteon XP40 - Approvals In both product types Frigolink and Frigoentry the new refrigerant Opteon XP40 (R449A) will be fully supported & included in the near future.

Opteon Refrigerants Refrigerant Opteon XP10 (R-513A) Opteon XP40 (R-449A) GWP* 631 (573) 1397 (1282) Flammability Class (ASHRAE)** Commercially Available 1 YES 1 YES Application Area Refrigeration & AC replacing R134a in DX and flooded systems Medium & Low Temperature Refrigeration Opteon XP44 (R-452A) Opteon YF (R-1234yf) Opteon XL20 (R454C***, DR-3) Opteon XL40 (R-454A, DR-7) Opteon XL41 (R-454B, DR-5A) Opteon XL55 (R-452B***, DR-55) 2141 (1945) 4 (1) 148 (146) 239 (238) 466 (467) 698 (676) 1 YES 2L YES 2L Planned 2016 2L Planned 2016 Transport Refrigeration and small LT hermetics Automotive AC & Small Charge Refrigeration Small Hermetic Medium and Low Temperature Refrigeration Small non-hermetic Medium and Low Temperature Refrigeration 2L Planned 2016 AC Replacement for R-410A 2L Planned 2016 AC Replacement for R-410A (Preferred R-410A replacement for Trane) *Intergovernmental Panel for Climate Change (IPCC) Assessment Report 4 (AR4) values used for EU F-Gas Legislation. IPCC Assessment Report 5 (AR5) values given in brackets for comparison. **ASHRAE Flammability class 2L must be used in accordance with the current codes and standards e.g. EN-378. *** Preliminary assignment and classification

Opteon XP44 Replaces R404A/R507A ASHRAE #: R-452A HFC/HFO blend: R32 / R125 / R1234yf (11% / 59% / 30%) ODP: Zero Ozone Depletion Potential GWP: 2140 (AR4) ASHRAE safety: A1 non-flammable Glide: 3-4K Can be topped off while servicing (do not mix with R-404A) Compatible with POE lubricants Compressor approvals: Frascold, many others in progress Applications: High compressor discharge temperature e.g. transport.

Opteon XP44 Performance Comparison Capacity, COP and Compressor Discharge temperatures are almost identical to R404A. Ideal for Applications where low compressor discharge temperatures are essential. T cond = 40ºC, Compressor isentropic efficiency = 0.7, evaporator superheat = 5K, total subcooling = 5K, suction line superheat = (T 51 cond -10-T evap )*0.35

Transport Refrigeration Opteon XP44 (R452A) March 2, 2016 52

Transport Refrigeration Opteon XP44 (R452A) Carrier Transicold has announced at the CV Show that it will offer R452A as an optional alternative to the existing R404A refrigerant. R452A has the same cooling capacity, fuel efficiency, reliability and refrigerant charge as R404A, but offers a 45 per cent GWP reduction. 53

Opteon XP44 Approved by Tecumseh GWP Discharge Temperature

Commercial Refrigeration - Opteon XP40 Over 200 supermarkets already Retrofitted in Europe. Germany, Netherlands, Spain, Italy, Belgium, Austria, UK, Greece, Sweden... Different makes of compressors and operating modes and technologies such as MT, LT, cascade systems More than 1000 installations using Opteon XP40 by the end of 2016. Minor or no adjustments made and no component or oil changes needed. To date all retrofits to Opteon XP40 have shown an improvement in refrigeration system power consumption compared with R-404A/ R-507A and R- 407F. Many more projects with major supermarkets and other refrigeration applications are in progress.

56

Help and Support www.opteon.com Product Information Case Studies Retrofit Guidelines Technical Data 57

Thank You! mark.hughes@chemours.com