PREMIER SERIES APARTMENT HOUSE SIZING

Similar documents
Distribution Restriction Statement

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

Commercial Hot Water Maker

Indirect-Fired Water Heaters

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Indirect-Fired Water Heaters

Sizing water heaters to provide sufficient hot water efficiently LEARN THREE METHODS YOU SHOULD BE USING TO DESIGN EFFICIENT SYSTEMS

Indirect-Fired Water Heaters

Indirect-Fired Water Heaters. BoilerMate Classic & Champion Series

Sizing Guide. For the Estimating of Flow Rates and Water Usage

TANKLESS PRODUCT GUIDE


Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

Intelligent ways to save fuel heating your Commercial building. Caravan Modular Boiler System. CHS Multiple Boiler System

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

Water Conservation Information. Regarding water well pump selection

The EnduroTi HIGH MASS. Superior Construction: COMMERCIAL CONDENSING BOILER. Stainless Steel Titanium Blend. 10 : 1 Turndown Ratio

Hot Water Makers. Efficiency at its Best

The WCGH High Efficiency Commercial Water Heater with Storage Tank

TANKLESS PRODUCT GUIDE

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

THE RINNAI LUXURY SERIES TANKLESS WATER HEATERS ENERGY-EFFICIENT HOT WATER NEVER LOOKED SO GOOD

NPE Series Condensing Tankless Water Heaters

Specifying High-Efficiency Water Heaters for Food Service

Instantaneous Water Heaters (IWH)

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

INDIRECT FIRED WATER HEATERS

More resources

G215 G315 Cast Iron Residential Boilers

energy-efficient Hot Water Never Looked So Good

HVAC Water chiller selection and optimisation of operation

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

National Grid s Direct Install Program for Commercial Customers

Presentation Outline. Commercial 1 Track. Unit #4: Commercial Water Heating

Effect Of Setup Thermostat Schedule On Heat Pump Water Heater Energy Consumption, Coefficient Of Performance And Peak Load

KLDJ : Task 2 Farm Bill Geothermal Heat Pump Template Appendix A. Appendix A Engineering Design

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

) Glossary of Terms Engineering Manual 1

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

Water Heaters. energy-efficient Hot Water Never Looked So Good #1 PRODUCT FOUR CONSECUTIVE YEARS IN BUILDER MAGAZINE S FAVORITE 50

AM Rapid Recovery Water Heaters

Hot Water Distribution System Losses in a Net-Zero Home

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

Ductless Series Variable Speed Split Systems

Copyright 2003 IBACOS, Inc. All rights reserved.

6 PIPING ARRANGEMENTS

THE NEW RINNAI LS SERIES TANKLESS WATER HEATERS

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

Why Pay for Two Condensing Systems When One Will Do?

Navien boilers for home heating

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

It Won t Just Meet Your Hot Water Needs IT WILL EXCEED THEM. RH180 HYBRID TANK-TANKLESS WATER HEATER

Versa- Hydro. up to 96% Efficient

Sustainable Hot Water: Better Design, Delivery, and Use

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

High Performance Building Guide 1

"Best Practices in Modern Hydronic Heating - THE DETAILS

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Reliance Commercial Program. Improved Business Continuity -Guaranteed!

iq1001, Gen II Submittal Data

Solar Thermal Planning Worksheet Date: / /

MACH CI. (Condensing-Indirect) Water Heating

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

iq751/iq1001/iq1501 Specifications (Floor-standing units)

Raptor 320HB & 399HB Submittal Sheet

Smith s Environmental High Efficiency Handbook

An evaluation of the reduced environmental impact from high density development

SPEED, STABILITY, & RELIABILITY N EW! IntelliQuad TM PLUS Combination Smoke and Carbon Monoxide (CO) Detector

For large or complex installa-

Split units, (single room unit and single condenser linked by pipework)

Commercial Gas Water Heaters

MECHANICAL VENTING VERSATILITY

REGULATIONS GOVERNING WATER SERVICE TO CUSTOMERS OF THE EAST BAY MUNICIPAL UTILITY DISTRICT SECTION 31 WATER EFFICIENCY REQUIREMENTS

YEARLY VIEW. 6/28/2016

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

PROFIRE -E SERIES BURNERS

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

Title: Heat Recovery From Milk Cooling Systems

The Revised Method of Test for Residential Water Heating and Its Impact on Incentive Programs

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

Water Heaters. energy-efficient Hot Water Never Looked So Good #1 PRODUCT FOUR CONSECUTIVE YEARS IN BUILDER MAGAZINE S FAVORITE 50

HYBRID GAS HEAT PUMP WATER HEATER WITH THERMAL EFFICIENCY 120% 23rd World Gas Conference, Amsterdam Main Author. Atsuya Tajima Japan

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Domestic Water Heating Systems CEU 255. Continuing Education from the American Society of Plumbing Engineers. January ASPE.

G315/6 Cast Iron Boiler

Hoval Modul-plus High-output calorifier 640 to 17,500 l/h

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

EXCEED THEM. COMPREHENSIVE WATER HEATING

Mul$family Buildings: Real World Monitored Data on Hot Water Energy and Water Use

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Transcription:

APARTMENT HOUSE SIZING _ Number of Apartments, A Average number of People per Apartment, P Sizing Commercial Premier Modules for Apartment Buildings Determine whether the apartment building usage should be classified as minimal, small shower head, 2 to 3 GPM, 2 1 /2 persons average occupancy; or average regular shower heads, 4 to 6 GPM, 3 to 4 persons per apartment. Select proper number of modules from Table 1 and the required heat generator capacity from Figure 1. Apartments (GPM) Head Manifold 2-5 1 7 20 3 6-25 2 14 20 1" 26-44 3 21 20 1 1 46-63 4 28 20 1 1 64-82 5 35 20 1 1 83-100 6 42 20 2" Apartments (GPM) Head Manifold 2-8 1 10 20 1" 9-32 2 21 20 1 1 33-55 3 31 20 1 1 56-79 4 42 20 2" 80-105 5 52 20 2" Apartments (GPM) Head Manifold 2-12 1 10 20 1" 13-40 2 21 20 1 1 41-66 3 31 20 2" 67-92 4 42 20 2" Apartments (GPM) Head Manifold 2-16 1 10 20 1" 17-62 2 21 20 1 1 63-105 3 31 20 2" 106-150 4 42 20 2" 0 20 40 60 80 100 120 140 Number of Apartment Units 2014 AMTROL Inc. MC 6107 Part #: 9040-573 (01/14)

COIN OPERATED LAUNDRY SIZING Machine Gallons Cycle Per Gallons Type/Model Quantity Per Cycle Hour* Per Hour Total # Machines Total Gals Per Cycle Total GPH Load** Corrected Total * If Cycle Per Hour Date is not available, use 1.5. ** Calculation based on a 40 F inlet water temperature. Use the correction factors on the right for other inlet water temperatures: Inlet Water Temperature Multiply Total GPH Load by: 50 F 0.90 60 F 0.80 70 F 0.70 Determining Storage Volume Sizing Commercial Premier for Coin Operated Laundry 1 Figure 1. For Required MBTU/hr 6 Diversification Table 1000 The number of machines drawing water at any one time varies widely. From the table below, determine the applicable diversification factor to use for this application. Total No. Machines Factor (D.F.) 1-12 100% 13-24 80% 25-36 60% 37-48 50% Required M BH 5 4 3 2 Number of Units Calculation: Total Storage Required Total gals/cycle x D.F. Selection of Models Calculation: Total Storage Number of Units = Storage Tank Gallon Storage Tank Gallon Premier Models 0-41 s 42-60 WH-60C s 61-80 WH-80C s 81-120 WH-120C s 120+ 1 0 1000 1 1 1 Total GPH Load Sizing based on recovery from 50 to 150 F plus storage. BTU/hr Number of Tanks Model Number 2014 AMTROL Inc. MC 6111 Part #: 9040-576 (01/14)

ELDERLY HOUSING SIZING Number of Apartments, A Average number of People per Apartment, P Sizing Commercial Premier Modules for Elderly Housing Determine usage as minimal, 1 1 / 4 persons with private kitchen facilities; or average,1 1 / 2 persons and/or with central dining facilities. Select proper number of modules from Table 1 and the required heat generator capacity from Figure 1. Apartments (GPM) Head Manifold 2-10 1 7 20 3 11-38 2 14 20 1" 39-66 3 21 20 1 1 67-94 4 28 20 1 1 95-122 5 35 20 1 1 123-150 6 42 20 2" Apartments (GPM) Head Manifold 2-16 1 10 20 1" 17-70 2 21 20 1 1 71-115 3 31 20 1 1 116-160 4 42 20 2" 161-5 52 20 2v Apartments (GPM) Head Manifold 2-22 1 10 20 1" 23-104 2 21 20 1 1 105-164 3 31 20 2" 165-230 4 42 20 2" Apartments (GPM) Head Manifold 2-34 1 10 20 1" 35-121 2 21 20 1 1 122-196 3 31 20 2" 197-260 4 42 20 2" 0 40 80 120 160 240 280 Number of Housing Units 2014 AMTROL Inc. MC 6106 Part #: 9040-572 (01/14)

HEAT GENERATOR / SPACE HEATING SIZING Introduction PREMIER SUPPLY There are two installation conditions that must be considered when sizing a heat generator/commercial Premier installation: A. When the heat generator is to work with the Premier to provide service hot water load only. B. When there are commercial applications that require sizing the heat generator for the combined space heating and service hot water loads the heat generator must be large enough to accommodate both loads. However, since both peaks do not occur simultaneously, it is advantageous to take diversity factors into consideration in sizing, since unnecessarily large equipment is wasteful of energy. The following guide will provide a rule of thumb method of PREMIER return estimation the additional heat generating capacity required for TYPICAL MODULAR INSTALLATION service hot water heating on typical Premier installations. NOTE: This guide is to be used in conjunction with Figure 1 from AMTROL s Commercial Evaluation and Sizing Forms for: 1. Apartment Houses 2. Motels 3. Nursing Homes 4. Coin Operated Laundry PREMIER PREMIER PREMIER A. Service Hot Water Load Only The heat generator installed to take care of the service hot water load only must meet the minimum capacity shown in the Evaluation and Sizing Forms for the particular application. B. Space Heating and Service Hot Water Loads Combined The factors which affect sizing for this type of installation are: 1. The piping and pickup losses which are typically applied when a boiler is installed only for space heating. 2. The number of hours of occurrence of temperatures anywhere near design temperatures for space heating represent an extremely low percentage of the total hours in the heating season. 3. The maximum space heating requirements do not occur at the time of day when the maximum peak service demands occur. 4. Service hot water heating equipment must be sized to supply the maximum rate of use for various periods of time from a few minutes to any hour or longer, and since these periods differ from day to day, and from month to month, the design capacity is significantly greater that that required for the vast majority of hours of service hot water usage. Rule-of-Thumb Estimating Method The factors shown provide a rule-of-thumb method for estimating the additional heat generating capacity required for service hot water heating on typical installations. The first is to calculate the ratio of maximum service hot water load to the gross output for space heating (including the normal allowance for piping and pickup). From Figure 2 determine the equivalent factor - this is multiplied by the service hot water load, and the product added to the gross space heating load, to determine the total heat generator capacity. EXAMPLE: 50 unit apartment, gross output required for space heating is 1,100,000 btu/h. Service hot water usage is minimal. Step 1. From Figure 1, Curve I, required for capacity for service hot water = 330,000 btu/h Step 2. The ratio of service hot water capacity to gross space heating capacity: RATIO.25.30.40.50.75 1.0 1.5 2.0 3.0 4.0 5.0 FACTOR 0.20.40.50.65.75.80.85.90.95 1.0 Maximum service hot water load 333,000 = Gross space heating 1,100,000 = 0.3 Step 3. From Figure 2, factor = 0.2 0.2 x 330,000 = 66,000 btu/h Step 4. Size of heat generator for combined service hot water and space heating loads: 1,100,000 + 66,000 = 1,166,000 btu/h 2014 AMTROL Inc. MC 6112 Part #: 9040-577 (01/14)

MOTEL SIZING _ Number of Rooms, A Average number of Occupants per Room, P Sizing Commercial Premier Modules for Motels Determine whether the motel should be classified as minimal, small shower head, 1 1 /2 persons typical occupancy; or average, regular shower heads 4-6 GPM, 2 persons per room (convention motel with scheduled meetings or tour buses with scheduled departures). Select proper number of modules from Table 1 and the required heat generator capacity from Figure 1. Laundry and food service are not included, these loads should be calculated separately. Rooms (GPM) Head Manifold 2-5 1 7 20 3 6-25 2 14 20 1" 26-44 3 21 20 1 1 45-63 4 28 20 1 1 64-82 5 35 20 1 1 83-100 6 42 20 2" Rooms (GPM) Head Manifold 2-9 1 10 20 1" 10-37 2 21 20 1 1 38-62 3 31 20 1 1 63-194 4 42 20 2" 95-128 5 52 20 2" Rooms (GPM) Head Manifold 2-14 1 10 20 1 15-48 2 21 20 1 1 /2 49-80 3 31 20 2 81-115 4 42 20 2 Rooms (GPM) Head Manifold 2-18 1 10 20 1 19-72 2 21 20 1 1 /2 73-123 3 31 20 2 124-176 4 42 20 2 0 25 50 75 100 125 150 175 Number of Units 2014 AMTROL Inc. MC 6108 Part #: 9040-574 (01/14)