SGS Condensing High Efficiency Gas-Solar Water Heater

Similar documents
SGE Condensing Gas - Solar Water Heater

BFM Balanced flue commercial water heater

BFC Cyclone Condensing Glass-Lined Water Heater

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

Boiler systems Upsilon Cascade. Innovation has a name.

BFM. Balanced Flue Commerial Water Heater BFM - 30/50/80/100/120. Installation, User and Service Manual. Innovation has a name.

C Tahiti. condensing

Condensing, pre-mixed, wall-hung gas boilers with water tank

Wall hung combination

Knight & Charger Water Heaters

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

WOLF GAS CONDENSING BOILERS COMFORTLINE

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

CITY OPEN - CITY BOX from 25 to 35 kw

PRODUCT GUIDE 2018/19 ACV HEATING AND HOT WATER SPECIALISTS

ADMP. Commercial Atmospheric Water Heater ADM - 40/50/60/80/90/115. Installation, User and Service Manual. Innovation has a name.

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Ultimate 3. Range Brochure

Energy. Range Brochure

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Brute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency

FASTflo. Working towards a cleaner future

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency

BENSON.... Variante3 Fired Unit Heaters...

Submittal. SFK 55 (Aqua 2 )

Rotavapor R-220 SE Technical data sheet

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

S-AF Floor Standing Condensing Boiler kW

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Hamworthy Dorchester DR-FC Evo 98%

1 VICTRIX ZEUS Superior kw I features

FCX FUEL OIL CONDENSING BOILER RANGE

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Easicom 3. Range Brochure

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Condensing Boiler It s a comfortable decision to make

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

RAYPAK HOT WATER & HEATING

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

940ESO Tankless Water Heater

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

aquaplus High performance combination boiler with integrated power store

Light commercial products. High output boilers Cascade systems

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

FORMENTERA KC - KRB - KR

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Sirius FS. Working towards a cleaner future

AM Rapid Recovery Water Heaters

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: MonoWave single-coil and DuoWave twin-coil unvented heat pump cylinders

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

Super high efficiency heating and hot water boilers for every type of home and commercial property.

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

ENERGY TOP. Condensing boiler solutions

RAYPAK HOT WATER & HEATING

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

GHP AWO 38 Technical overview

Sirius WH. Working towards a cleaner future

PRODUCT GUIDE HIGH EFFICIENCY HOT WATER AND HEATING PRODUCTS

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

The Main Heating Range Guide. The Main Heating range of affordable combi, system and heat only boilers, cylinders and water heaters.

thermocompact High performance system boiler range

ecomax pro High efficiency condensing boiler range for traditional systems

Commercial Tankless Rack System

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Baxi 600, 400 & 200 boilers. Range guide

ecotec range High efficiency condensing boiler range

SATK 30 heat interface unit

Duo-tec combi, Megaflo system and Solo heat only boilers. Range guide

ecotec plus New high efficiency condensing combination and system boiler ranges

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

White paper: New Ecodesign rules and energy labelling for space and water heaters

CBX 24, 32 & 38 SBX 30

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Commercial Gas Fired Water Heaters

For latest prices and delivery to your door visit MyTub Ltd

VICTRIX Superior kw Export VICTRIX Superior kw X Export

EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Broag Pressurisation equipment

8FUEL OIL CONDENSING BOILERS

VORTEX BLUE OIL RANGE

Versa. Series. 96% Efficient. Versa-Hydro. Versa-Flame. Advanced Heating & Hot Water Systems

VORTEX BLUE OIL RANGE

Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

The energy you need. High Efficiency Boilers & Accessories

Cylinders for Domestic Purposes Heat Pumps

Transcription:

ondensing High Efficiency as-solar ater Heater - 8/0/0/0/80/100/10 Solar control Storage tank ully room-sealed condensing high efficiency gas-solar water heater Maximum solar contribution through fully integrated intelligent solar controller, heat comfort guaranteed utomatic gas/air premix burning system including burner modulation elivered with low-maintenance inert anodes Efficiency 7% (gross) NOx emission 0 ppm (dry air free) NOx class hisper quiet operation (< db() at m distance from roof duct) One control and display unit for the complete installation Extra solar contribution possible up to 0% compared to standard solar systems Easy fault diagnosis and computer controlled digital week timer Programmable for legionella purge cycle Voltage-free contact for general fault indication to BMS Suitable in combination with ITE indirect water heaters up to 10 litres or larger applications.o. Smith developed the IT storage tanks up to 000 litres Varying water temperature setting from 0 to 80 with use of week timer elivered on steel base for convenient transport and installation Innovation has a name.

eatures and options - ully room-sealed condensing high efficiency gas-solar water heater - Maximum solar contribution through fully integrated intelligent solar controller, heat comfort guaranteed - utomatic gas/air premix burning system including burner modulation - elivered with low-maintenance inert anodes - Efficiency 7% (gross) - NOx emission 0 ppm (dry air free) NOx class - hisper quiet operation (< db() at m distance from roof duct) - One control and display unit for the complete installation - Extra solar contribution possible up to 0% compared to standard solar systems - Easy fault diagnosis and computer controlled digital week timer - Programmable for legionella purge cycle - Voltage-free contact for general fault indication to BMS - Suitable in combination with ITE indirect water heaters up to 10 litres - or larger applications.o. Smith developed the IT storage tanks up to 000 litres - Varying water temperature setting from 0 to 80 with use of week timer - elivered on steel base for convenient transport and installation - Solar collectors available with ingenious drain-back system to prevent stagnation temperatures from arising in the installation - is compatible with solar collectors or as a stand-alone water heater - ummy sensor kit: an optional dummy sensor kit available for the to operate without a solar circuit; for use in a staged development where H may be required ahead of fitting a solar circuit. Energy labeling 8 0 0 0 10 Load Profil - XXL XXL XXL XXL XL XL XL Energy labeling - - - - Efficiency % 1 1 1 0 nnual Electricity onsumption (E) kh 7 7 7 aily Electricity onsumption kh 0.1 0. 0. 0. 0.81 0.0 0.01 nnual uel onsumption (E) J V 1 1 1 1 aily uel onsumption kh V.01....811. 0.00 Nitrogen ioxide Emission (NO) mg/kh V 7 7 Mixed ater of 0 (according V0) ltr. 1 18 Sound Power Level db 7 Other Load Profil - - - XL XL - - - Efficiency % - - 8 8 - - - nnual Electricity onsumption (E) kh - - - - - aily Electricity onsumption kh - - 0. 0. - - - nnual uel onsumption (E) J V - - 1 1 - - - aily uel onsumption kh V - -.01.1 - - - Nitrogen ioxide Emission (NO) mg/kh V - - 7 - - - Mixed ater of 0 (according V0) ltr. - - 01 - - -

Technical specifications 8 0 0 0 10 as data natural gas H (0) Input* k.... 8. 10. 18.8 Output k 1.0.7 0. 0. 8. 100.7 11.8 Inlet pressure mbar 0 0 0 0 0 0 0 as consumption ** m/h.1..0.0 8. 10.1 1. lue gas discharge 0 0 0 0 as data propane P (1) Input* k 1.. 1.1.0 8.8 10. 1.1 Output k 1.0.7 0. 0. 8. 100.7 11.8 Inlet pressure mbar 7/0 7/0 7/0 7/0 7/0 7/0 7/0 as consumption ** kg/h...7..1 7..0 lue gas discharge 0 0 0 0 eneral Nox ppm 0 0 0 0 0 0 0 Noise level db() < < < < < < < Efficiency (gross) % 8 7 eight empty kg 0 80 80 80 Maximum weight kg 1 07 07 07 0 0 0 Storage capacity l 17 8 8 8 80 80 80 Max. temperature setting 80 80 80 80 80 80 80 Maximum working pressure kpa (bar) 800 (8) raw-off capacity *** T set = º / T cold = 10º 0 min. T l 70 0 0 70 0 1100 100 0 min. T l 70 70 100 100 1800 100 00 0 min. T l 80 1100 1700 000 00 100 700 10 min. T l 100 100 100 00 00 100 00 ontinuous T l/h 10 0 0 100 1700 000 00 Heating-up time T= min 1 1 17 1 1 0 min. T 0 l 10 0 0 10 780 10 1100 0 min. T 0 l 70 0 0 100 100 1800 00 0 min. T 0 l 80 0 100 1700 00 700 00 10 min. T 0 l 100 100 100 00 000 00 00 ontinuous T 0 l/h 0 70 870 1100 100 1800 100 Heating-up time T 0 min. 1 0 17 1 0 min T= l 0 0 0 0 70 70 0 0 min T= l 00 0 80 1000 100 100 100 0 min T= l 70 800 100 100 000 00 00 10 min T= l 0 1100 1700 000 700 00 800 ontinuous T l/h 0 0 70 0 100 100 000 Heating-up time T min. 7 8 18 1 Elektrical data Power consumption 7 11 1 0 Power supply V/Hz 0 (-1% +10% V)/0 (±1Hz) Shipping data eight incl. packaging kg 1 1 1 idth packaging mm 870 870 870 870 0 0 0 Height packaging mm 10 0 0 0 00 00 00 epth packaging mm 0 0 0 0 100 100 100 * as data on gross value ** as consumption at 1 en 101, mbar *** Based on nat gas

imensions 8-0 Hx E º º º Hy Ny 8 0 0 0 18 01 01 01 00 00 00 0 0 0 0 0 0 0 70 70 70 70 80 80 80 E 1000 1000 1000 80 80 80 80 00 00 00 100/10 100/10 100/10 100/10 10/00 10/00 10/00 H 18 180 180 180 1 1 1 Hx 10 10 10 Hy 7 7 7 7 0 0 0 K 180 110 110 110 18 18 18 M N 18 01 01 01 00 00 00 Ny 0 0 0 0 0 0 0 P 70 70 70 0 0 0 R 180 170 170 170 S 10 10 10 1 1 1 0 0 0 0 0 0 10 K S N H 1 old water connection R1 1 / Hot water connection R1 1 / as valve connection R / rain valve connection 1 (8-0) / (80-10) Temperature and pressure valve 1 / 11. NPT Inspection flange x70 7 ondensate drain Rp1 P M 1 R 7 imensions in mm. -10 Hx Hy E.º Ny º 18º º Solar control N K H S P R 1 M 7 Storage tank

Installation diagrams UNVENTE 1 1 10 1 VENTE 1 T 1 T 11 1 1 T 1 T 8 B 11 S S S1 8 7 S Q T 17 1 1 1 H 1 Pressure reduce valve Inlet security group T&P valve Stop valve Non-return valve irculation pump 8 ontrol pump rain valve 10 as valve 11 Service valve 1 Temperature meter 1 ondense drain 1 Hot water tap 1 Expansion valve 1 Expansion vessel 17 Three way valve 18 ater cistern 1 loat valve Pressure valve ir bleed 7 lowmeter 8 Solar pump station Junction box S1 T-collector S T-tank S T-top tank S T-return solar old water supply B Hot water outlet irculation pipe as supply E ater overflow oil inlet oil outlet H Expansion pipe S1 11 1 1 1 10 B 8 B S 8 1 18 E.O. Smith unvented system kits utilise combination valves. In the instruction manual you will find all the necessary information regarding connection, installation and maintenance of the product; including information on the electrical connections. Information regarding the recycling or disposal of the 1 S 7 S Q T product can also be found in the manual. This manual is delivered with the appliance and can also be found on our website; www.aosmith.co.uk. Optional: Theta ual Service Theta dual service means using the available hot water from one of our water heaters for both domestic hot water (H) and heating. ual service can be used in combination with a B yclone, SE or system. This is a perfect system for locations where a lot of domestic hot water and a little bit of heating is requested. The intelligent control uses the available hot water very efficiently to meet the heating demand from one system without compromising comfort levels. THET MOULE OR rt. No. k H capacity T H system omestic hot water ontrol H flow T 0 0 0 0 T 0 10 0 10 T 0 0 0 0 T 0 0 0 0 T 0 10 0 10 T 0 0 0 0 T 0 0 0 0 T 0 10 0 10 T 0 0 0 0 T Plate heat exchanger single separation (a double separated plate heat exchanger can be delivered upon request) Primary H pump Temperature sensor with cable incl. clip Three-way mixing valve including cables Instruction manual urther information is available on our website: www.aosmith.co.uk old water H return

Installation options water heater should be installed according category B, 1,, or *. 1 8 0 0 0 10 B oncentric iameter (mm) 100/10 100/10 100/10 100/10 10/00 10/00 10/00 Max. length (m) 0 0 0 0 1 1 1 Max. /0 bends 7 7 7 7 Parallel (standard diameter) iameter (mm) 100 100 100 100 10 10 10 Max. length (m) L equivalent /bend 0 (m)....... L equivalent /bend º (m) 1. 1. 1. 1. 1. 1. 1. Parallel (larger diameter for more length) iameter (mm) 10 10 10 10 10 10 10 Max. length (m) 100 100 100 100 100 100 100 L equivalent /bend 0º (m)....... L equivalent /bend º (m) 1. 1. 1. 1. 1. 1. 1. * ll appliances are also approved for installations where the unit is supplied without venting materials (). oncentric flues It is not permitted to use more than the specified number of bends, even when the duct is shorter than the maximum length. bend is equivalent to a 0 bend. Parallel flues - The maximum permissible length should be reduced by the equivalent length of each bend. (Note: for a parallel installation this means that changes in direction amount to bends ( in the supply duct and in the flue). - The maximum length also applies if a parallel installation has different supply and flue duct lengths (B, ). - ombined flues () shall be fitted with a condensate drain. urther information on the flue gas discharge materials can be found in the Installation manual. Note: horizontal flue runs must be installed with a fall of at least mm per metre. Minimum space requirements X Y V X Y V 8 0 0 Minimal space for wall duct (mm) V 0 0 0 0 0 0 0 70 70 70 70 0 0 0 X 10 170 170 170 0 0 0 X * 080 0 0 0 80 80 80 Y 180 180 180 180 10 10 10 Y * 100 100 100 100 1170 1170 1170 Minimal space for roof duct (mm) V 100 100 100 100 170 170 170 10 10 10 10 110 110 110 X 00 0 0 0 0 0 0 X ** 110 70 70 70 70 70 70 Y 11 11 11 11 10 10 10 Y ** 10 10 10 0 * istance without concentric pipe between bend and wall duct. ** istance without concentric pipe between appliance and roof duct. 10 Ø100/10 Ø100/10 Ø100/10 Ø100/10 Ø10/00 Ø10/00 Ø10/00 ata subject to change UK/11//10 Terms and conditions apply, please refer to our website..o. Smith ater Heaters, Unit B8 rmstrong Mall, Southwood Business Park, arnborough, Hampshire, U 1 ONR www.aosmith.co.uk.o. Smith ater Heaters is a trading name of dveco Ltd. Reg. No. 1078