TECHNICAL SPECIFICATIONS

Similar documents
Technical Information Pack

TECHNICAL SPECIFICATION Lighting Systems. Festival Theatre

Notes on Stage Map Page 18. DOn t glue it in YET

Technical Rider Preliminary, version 1.0 April 2018

GAIETY TECHNICAL SPECIFICATION

GAIETY TECHNICAL SPECIFICATION

RIVERSIDE THEATRES Corner Church St & Market St Parramatta NSW PO Box 3636 Parramatta NSW

PRODUCTION MANUAL 2017

Whaleys School Stage Set Up Guide

The SEC Armadillo CDM Information

SECTION THEATER CURTAINS AND TRACKS. A. American Society for Testing and Materials (ASTM):

The Kamikaze Fireflies

Spier Conference Centre

***************************************************************************************************************

PRODUCTION BIBLE 2017

Exit to Studio 3. Stage. Upper. Entrance. Stage. Ramp. Wheelchair Bay. Exit to Lift, Toilets, Stairs & Studio 3

PARK CENTER SENIOR HIGH

Lake Macquarie Performing Arts Centre Operating Manual

Operation Manual. ParaBeam 400/200 Series. ParaBeam 400 Center Mount. ParaBeam 400 Pole-Op

normal variant - traverse

TECHNICAL INFORMATION PACK. Main Auditorium. Carrick Street Ayr KA7 1NU TEL:

VENUE INFORMATION FOR SCHOOLS

Margaret Court Arena. Roadskills Spandau Ballet Human Nature The Preatures. Medical Simulation Labs Northern Health s Hi-Tech AV

D3D Wi-Fi GSM Smart Alarm System -User Manual

PRIVATE E V E N TS Walkers Court London, W1F 0ED

INTRODUCTION TO PERFORMING ARTS TERMINOLOGY

Access Statement. Dawyck Botanic Garden Access Statement November 1, Dawyck Botanic Garden Stobo Scottish Borders EH45 9JU +44 (0)

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

Iroquois theatre, Chicago, The fire in this newly opened but badly planned theatre in Chicago in January 1904 caused 572 deaths

Technical Information Handbook

C-Bus Application Note. Function Rooms and Ballrooms. Overview

SOHO X. 4" Two-way passive system

USER MANUAL Table of Contents

W-715X... Fog machine FLC liter container of water-based fluid for W C Cleaning solution

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Access Statement for Soleil D'or Bed and Breakfast

10 11 / / / 19 / 20 / / / 27

USER MANUAL Table of Contents

ISD 279 Osseo Area Schools Park Center Senior High School. Auditorium Handbook

Little Moreton Hall Access Statement

Intrusion. Outdoor protection perimeter

EQUIPMENT GUIDE LIST - CHAPTER

Little Moreton Hall Access Statement

SPECIFICATION MAZARIN 72 4 CABIN VERSION

Mompesson House The Close Salisbury Wiltshire SP1 2EL. T: E: Page 1 of 6

NOTE TO SPECIFYING ARCHITECT REGARDING SECTION PERFORMANCE LIGHTING SYSTEM (24 DIMMERS)

-SAMPLE- Safety Inspection Checklist: Manufacturing

PATRICIA GEORGE DECIO MAINSTAGE THEATRE

Osseo Senior High School

Diva Acoustical Shell

Custom Stage Curtains Theatrical Lighting Rigging Design/Installation/Inspection Since 1856

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Belper Rugby Club- Identified Repairs and Renewals

WPUMC Capital Report Existing Facilities February 19, Maintenance Coordinator George Smit

Special Features 3638 Quail View Road Charlotte, NC ,076 SF Heated Living Area Acre Lot July 14, 2009

Whitechapel Gallery Venue Hire. whitechapelgallery.org

MY HOME LaYOut Of the building 22

EAST DEAN & FRISTON VILLAGE HALL FIRE RISK ASSESSMENT

ARQIS Series CABINET LOUDSPEAKERS. Architectural Loudspeaker Cabinets USER MANUAL

Vehicle Detection: How To Choose the Right Technology... 3

Visual Story. This information is designed to help you prepare for a visit to Levant Mine in Cornwall. Created by

Fire Risk Assessment

Acoustics & Beam Steering Technology. Media Infrastructure Architect

Projecteur bain de pieds LED - Blanc variable LED - Variable White Footlight. Model Length Power S

Loud Technologies, Inc. CE DECLARATION OF CONFORMITY

Quotation of inels system

Festival of light. 10 th. H ow Busan Cinema Center has brought glitz and glamour to a culture-loving South Korean city

GENERAL CATALOGUE 2011

HIRE COLLECTION FINISHING TOUCHES

Office of the Fire Chief City of Richland Hills, Texas

SHELL SCHEME FOR EXHIBITIONS AND EVENTS GES COMPLETE

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

Lindsey Beane. Executive Summary

Access Statement for Craster Rocks

Furniture LOT 1-6. LOT 1: Textiles, curtains and bedding. Fitted Bed Sheet, Cotton, various colors, No. Item Picture Samples. Double Bed.

Landlord Application Pack

GROUNDPLAN DIVORCE PARTY by MARK SCHWARTZ, AMY BOTWINICK & JAY FALZONE RINKER SPACE AT THE KRAVIS CENTER DIRECTED BY JAY FALZONE

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Available with vacant possession and no onward chain

ARCSYSTEM. Fully-dimmable LED lighting for auditoriums, retail and commercial installations

GSM RFID VOICE Alarm System

Operations Manual. Updated To Include NEW Web Cam IPhone and Android Viewing Instructions

SIA/IAPSC CAD Security Symbols

Security GSM Alarm System

EMERGENCY EVACUATION PLAN

Public Address and Voice Alarm. Version 1 DESIGN & INSTALLATION GUIDE

Make Model Length Price Year Condition Location. Bertram Convertible 54 ft $ 290, Used

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

IDoorBell Fon DP68 Quick Installation Guide

SATURN 12 SYSTEM. Order Code: SPEA41 ENGLISH

Property Name Access Statement

Driver Resource Manual Unit 6 Emergency Evacuation

Hardy s Cottage Access Statement

Revision th July The Pinnacle Apartments. Standard Specifications and Finishes

14 Kirkstone Avenue, North Shields, NE30. Price guide 245,000

Fire alarm bells (and associated fire detection equipment) are tested on Wednesday mornings between

User Manual LIGHTMEN.COM. Apollo A75050

Whitechapel Gallery Venue Hire Gallery 1

Transcription:

TECHNICAL SPECIFICATIONS 1

Contents Contents 2 Address 4 Staff 4 Telephone Numbers 4 Auditorium and Seating Capacity 4 Stage 5 Access 5 Stage Specifications 5 Fly s 6 Masking & Drapes 8 Access Equipment 8 Lighting Control 9 Dimming 9 Mains Supplies 9 Lantern Stock 10 Accessories and cable 10 Sound Control 11 Outboard 11 Speaker System 11 Microphones 11 Ancillaries and Cabling 12 Touring 12 Communications 12 Q-Lites 12 Comms 12 2

Prompt desk 12 Hearing Assistance & Audio Description 13 Backstage Facilities 13 Venue plans 14 Directions to The Lime Tree Theatre 18 Scene Dock Access illustration 19 3

Address The Lime Tree Theatre Mary Immaculate Collage Limerick Ireland Staff Managing Director Marketing Manager Technical Manager Box Office Manager Louise Donlon Gill Fenton Jay Kavanagh Sharon Kiely Telephone Number (061) 953400 Auditorium and Seating Capacity 510 seat (4 disabled positions) raked auditorium across 3 building levels. 6 audience entrance / exit doors. There are 5 banks of seats that can be removed. Please inform the theatre at the earliest opportunity for the removal of any seats from the seating plan 4

Stage Access Get in is via a cargo lift from ground level loading bay to stage level, the get in door is situated on the stage right side of the stage. The cargo lift is 5.77m wide 2.40m deep and 3m high with a meter and a half headroom at the top. S.W.L 5000KG. Parking is available for a van or truck outside the cargo lift. Stage Specifications The stage is a ply sprung floor with an m.d.f skin painted matt black. You may not screw into the floor. We do however carry a stock of braces and stage weights. See masking and drapes p5. There is a removable arced stage extension in 13 pieces which runs the full width of the proscenium arch. 2.290m at the apex 96cm at the side and 1.1m high We have 4 steel deck 8x4 with a 80mm ply top. Assorted leg height. Please contact the technical manager for further details. Stage height 1.1m Proscenium opening 10m Proscenium Height 5.95m Depth of setting line without forestage 10m Grid height 11.23m Fly Bar height 9.m Fly bar length 11.m Fly bar diameter 48mm od Stage right wing dimensions 3m wide x 9.2m deep Stage left wing dimensions 3m wide x 9.2m deep. 5

Fly s Front of house 30cm box truss for pa immediately in front of the false proscenium flown on two Loadguard BGV C1 500kg hoist. U.D.L.1000kg. Point load 500kg 6 motorized dual speed bars normally containing 4 internally wired bars with 16amp sockets and 1 motorized set of traverse tabs. SWL. 500KG. 21 manual hemp sets with a 100kg SWL. Number Purpose Type S.W.L N/A Loudspeaker truss Motorized 1000kg N/A Blue house border Dead hung N/a N/A Blue house tabs Dead hung N/a N/A False proscenium Dead hung N/a 1 Black border Manual hemp set 100kg H1 Lx.1 with I.W.B Motorized set 500kg 2 Wind up rear projection screen Hand winch 200kg 3 Empty Manual hemp set 100kg 4 Empty Manual hemp set 100kg 5 Empty Manual hemp set 100kg 6 Black border Manual hemp set 100kg H2 Lx.2 with I.W.B Motorized set 500kg 7 Empty Manual hemp set 100kg 8 Empty Manual hemp set 100kg 9 Empty Manual hemp set 100kg 10 Black border Manual hemp set 100kg H3 Lx 3 with I.W.B Motorized set 500kg 11 Empty Manual hemp set 100kg 12 Empty Manual hemp set 100kg H4 Lx 4 with I.W.B Motorized set 500kg 13 Empty Manual hemp set 100kg 6

14 Black border Manual hemp set 100kg H5 Lx 5 with I.W.B Motorized set 500kg 15 Empty Manual hemp set 100kg 16 Empty Manual hemp set 100kg 17 Empty Manual hemp set 100kg 18 Black border Manual hemp set 100kg H6 Traverse tabs. Motorized set 500kg 19 Empty Manual hemp set 100kg 20 Empty Manual hemp set 100kg 21 Empty. This bar has a limited height of 6m. Manual hemp set 100kg Fly s Motorized set control from gantry or onstage pickle. Hemp sets located on the stage left side of gantry. 12 x Loadguard BGV C1 500kg hoists on three up down beams on beam trollies in groups of four to a beam. 2 x 11m lengths of ladder truss available rigged on chain hoists. 6-way guardian motor controller situated in the gantry. See hanging plot. For positions and additional rigging points Wrap around gantry 3 sides. Tension wire grid for access to position motors 13.15m x 13.15m 7

Masking & Drapes 1 x pair of midnight blue velour house tab and pelmet 6m x 7.5m 1 x pair of black wool serge curtains 6m x 7.5m 8 x black wool serge legs on swivels 2m x 5.9m 8 x black wool serge legs on tracks 1.5m x 6m 5 x black wool serge borders 11m x 2m 1 x white cyclorama 11m x 7.5m Assorted braces and stage weights Assorted lengths of conduit Access equipment. 1 x Zarges ladder max working height 6.5m 1 x Genie vertical hoist. Working height 8m s.w.l 150kg 1 x small A-Frame ladder. 8

Lighting Control ETC Congo avab console enabled up to 10 universes with riggers remote. Lighting facility panels with dimming power, non dims, hot power, dmx and data to the following locations. Control room Front of house bridges. 1 and 2. Mid auditorium boom left and right. Proscenium boom left and right. Stage floor downstage left and right and upstage left and right. Fly floor left and right. Dimming ETC sensor dimmers. 150 dimmable circuits 36 front of house Maximum of 106 onstage including floor patches 4 at each mid auditorium boom. 25 non dim dmx circuits located throughout the stage and auditorium 25 x 20amp independent circuits at various points around the stage and auditorium with a manual switch beside each circuit. Mains supplies. Lighting power. 200A, 220/315V 3Phase stage left check for hook! Sound power 1 x 32A single phase stage right Rigging power 1 x 63A 220/315v 3 phase located in the stage right gantry. 9

Lantern stock 6 x Source 4 19º 750W 16 x Source 4 26º 750W 6 x Source 4 36º 750W 16 x Source 4 15/30º 750W 10 x Source 4 25/50º 750W 24x Selecon Rama Fresnel 1200W 8x Selecon Arena Pebble Convex 2000W 36x Thomas Par 64 1000W 6x Selecon Lui 4-way cyc floods 1000W 2x Robert Juliat Topaze Follow spot with stand 1200w msd. 10x Ignition Par 64 LED floor cans. 20 x 3W LED 6x Euro light led flood with barn doors 18 x 8W 12º led Accessories 4 x iris for source 4 6 x gobo holder for source4 6 x top hat for source4 40 x Doughty boom arms 6 x Doughty Boom base 6 x aluminum scaffold pipe for above. 1 x rosco delta hazer. Cable (power and control) 12 x 6 way Internally wired bars 6 x 5m multicore 6 x 12m multicore 6 x 16m multicore 6 x 20m multicore. 10 x male 16A spider 10 x female 16A spider 6 x 4 way socket boxes (for cyc floods) 20 x 3m 16A mains cable 20 x 5m 16A mains cable 20 x 10m 16A mains cable 20 x 3way 16A splitter Please note that the multicore is used with the onstage lighting bars. 10

5 x 3m DMX 5 x 5m DMX 5 x 10m DMX While we have a stock of gel, it is limited and it is suggested that companies will supply their own colour. Sound Control Yamaha LS9 16 digital console (booth & auditorium mix positions) usually situated in control booth Fitted with YGDAI MY8-AD96 analogue input card, Dsub cable and 8 way pre amp. Outboard 1 x Denon DN-T620 CD/Tape player Speaker system 1 x D&B Q7 stage right on s/r proscenium lighting boom 2 x D&B Q7 Centre cluster on loud speaker truss 1 x D&B Q7 stage left on s/l proscenium lighting boom. 2 x D&B Q7 Delays hung from FOH 2 2 x D&B QSUB on the floor in front of the stage. 5 x D&B E0 front fills 4 x D&B E12 monitors. Microphones 4 x Shure Beta 91A 6 x Shure SM58-LC 4 x Shure SM57-LC 1 x Shure DMH57-52 Drum mic set. 4 x Shure PG81-XLR 11

Ancillaries and cable 6 x BSS AR133 Di box 10 x K&N tall boom mic stands 6 x K&N short boom mic stands Assorted mic cable 3m 15m Assorted multicore for patching into our audio system Touring We are happy for touring companies to use our system and equipment. The front of house mix position is located at the back of the auditorium with easy access to our full audio patch system. Q-Lites The theatre operates a totally patchable GDS Cuelight system, which is built into the stage management desk, with 12 remote outstations and further fixed outstations located at each auditorium door. Comms The theatre operates a 2-ring Techpro system capable of handling up to 12 outstations. We have 10 headsets and belt packs which can be patched to most areas in the stage and auditorium as well as comms built into the stage management desk. Prompt desk. The stage management desk has a full cue light system and paging facility to front of house, back of house and bar bells. The desk can be situated in the following areas. Stage right wing, stage left wing or control room. There is a paging station located in the control room. 12

Hearing Assistance The theatre operates a Sennheiser IR system for use with dedicated headsets and neck loops. This is connected to the show relay system. We have a stock of 12 headsets and 5 loop sets. WiFi. 1. Log on to the Visitor network. 2. Open your web browser. 3. You will be transported to a log in page and asked to enter a username and password. 4. Enter the username; limetree.production 5. Enter the password; Theatre1234 You should now have internet access. If you have any issues joining the network, please contact the technical manager. Backstage Facilities Access to the back stage and dressing rooms is via a door located in the foyer. This door is accessed with a swipe card, which we will provide to the company on their arrival. There are two dressing rooms and one green room. There is a shower and hand basin in each dressing room. There is a show relay video monitor and loudspeaker in both dressing rooms and the green room Toilet facilities are located outside dressing room 1. and the green room. Both toilets are wheelchair accessible 13

Laundry facilities There is a 7kg washer and a 9kg condenser drier located in the green room. PLANS. 14

15

16

17

Directions to the Lime Tree Theatre, Mary Immaculate College, Limerick Coming from East/North on M7 (Nenagh/Dublin) Follow the by-pass around Limerick city to last exit before the tunnel (EXIT 2) From EXIT 2: At roundabout at bottom of off-ramp at EXIT 2, take 3 rd exit, following signs for the city centre Immediately after passing under the motorway, is a second roundabout, take 2 nd exit, continuing to follow signs for City Centre (you are now on the Dock Road) Drive approx. 1 km, come to another roundabout, go straight through, continuing towards the city centre. Drive through next set of traffic lights At second set of traffic lights, turn right on to Courtbrack Avenue Drive approx 300m, main entrance to Mary Immaculate College is on the left. Drive into the grounds, following the road as it veers to the right. The Theatre is in the main modern building directly ahead. Parking is to the left. Access to the scene dock: as you drive towards the building you will see an entrance that allows you to drive in towards the main entrance (restricted access) 18

Scene Dock Access Scene Dock. 19