Lighting Redesign. Art & Visual Technology Building. Allen Walker Lighting/Electrical Option. Advisors: Dr. Mistrick Professor Dannerth

Similar documents
Thesis Proposal. Christine Clowes Lighting/Electrical Option Faculty Consultants: Professor Dannerth & Professor Mistrick January 30, 2009

Chandler City Hall Chandler, Arizona

Executive Summary. Houston Museum of American Art New York, New York

Technical Report One

Depth Work Part 1: Lighting Design

HARRY RANSOM HUMANITIES RESEARCH CENTER

Tech Report. September 9,

Senior Thesis Presentation

Duke University Medical School. Duke School of Nursing

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

Thesis Proposal Update #2

Shepherd University Wellness Center AE 481 Revised Thesis Proposal

Des Places Residence Hall

Franklin Square Hospital Center

Shepherd University Wellness Center AE 481 Thesis Proposal

Perot Museum of Nature and Science Final Lighting Design Presentation. Yucheng Lu, Lighting Electrical, Adviser: Shawn Good

4/30/2008. St. Elizabeth s New Hospital Nicholas Nigro Construction Management. AE Senior Thesis Outline

THE AUGUST WILSON CENTER FOR AFRICAN AMERICAN CULTURE PITTSBURGH, PENNSYLVANIA. PERKINS + WILL chematic Design Presentation MICHAEL P.

Center for Health Research and Rural Advocacy

Existing Area Description: The area is an angle around the North point of the building. It is a wide patio wrapping the façade of the building.

Kimberly Morton The Pennsylvania State University Architectural Engineering Program Lighting/Electrical Faculty Advisor: Dr.

Lindsey Beane. Executive Summary

HARRY RANSOM HUMANITIES RESEARCH CENTER

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr.

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

Jamie Devenger Senior Thesis Princeton University Sherrerd Hall 1 Lighting Proposal Memo September 11, 2009

City of Green Administration Building. Brian Koze November 12, Lighting Schematic Design Presentation

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

Café DUSON- Overview

Lighting Proposal Memo

Lighting Proposal Memo. Lighting Proposal. Angela Nudy Lighting/Electrical Dr. Mistrick Lighting Proposal Memo 1

Lord Stirling Community School

Lighting Depth CAL IT 2. Brian Smith. Introduction

SMEAL COLLEGE OF BUSINESS BUILDING University Park, PA

Duke Tower Main Entrance Lobby Overview

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

Towson West Village Commons

Lighting Existing Conditions and Design Criteria Report

Architectural Engineering Lighting/Electrical Option

Schematic Design Proposal Presentation

Thesis Proposal Sherrerd Hall, Princeton University, NJ

Dorrance H. Hamilton Building

Lobby Lighting Redesign

Lighting System Conceptual Design

Technical Report IVb: Proposal

dr. robert paterson Spring 2016

Technical Report #1 Existing Lighting Conditions and Design Criteria

The Ed Roberts Campus Berkeley, CA

Developing Early Design Simulation Tools For Persons with Vision Impairments

Allen Street Civic District Redevelopment Area Plan Redevelopment Plan & Proposal State College Planning Commission State College Redevelopment

Technical Report Two

2012 Exhibition of School Planning and Architecture. North Toronto Collegiate Institute Redevelopment (NTCI)

NORTH TORONTO COLLEGIATE INSTITUTE. the Journey to a New Urban School + the Partnerships which gave it Life

THE ESTABLISHMENT OF URBAN OPEN SPACES TO MEET USER NEEDS: A COMPARATIVE CASE STUDY OF TWO NEIGHBOURHOOD PARKS IN ABUJA, NIGERIA

Challenges and Methods of Estimating a Conceptual HVAC Design

NRG SYSTEMS, HINESBURG, VT

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

Hawthorn Building. Penn State Altoona Campus Altoona, PA. Walter Nichols. Lighting/Electrical Option Faculty Advisor: Dr.

F.W. Olin Physical Science Laboratory

Lighting Depth Part 1: Exterior Space

Marie Ostrowski Lighting/Electrical Dr. Mistrick Science Building Phase 1 Buffalo State College Buffalo, NY Monday, October 5, 2009 Technical Report

Amendment C146 Melton Planning Scheme Expert Evidence Statement Traffic & Transport Beattys Road, Plumpton

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Daylight and Whole-Building Energy Analysis Using Radiance in IES <Virtual Environment>

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

Lighting Existing Conditions and Design Criteria Report

Erin McCauley The Gateway Building

1.1.0 Exterior Facade

University of California Santa Barbara. Student Resource Building

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

MD and Its Impact on Lab Facilities

Video: Universal Design

Description. Summary. MCPB Item No. Date: 01/17/13. Bethesda Crescent, Limited Site Plan Amendment, A, A

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Tech Report 1, Part 1: Lighting Proposal Memo TO: Shawn Good

[Lighting Proposal Memo ] Hotel and Conference Center Virginia, USA

UNIVERSITY OF PENNSYLVANIA NEURAL AND BEHAVIORAL SCIENCES BUILDING 415 University Ave, Philadelphia, PA 19104

TEAM 6 NWARAMBILLI UGBODE

Retrofitting a Multi-Unit Residential Building To Reduce Purchased Energy by a Factor of 10. Chris Richards

The AstroPower Headquarters Newark, Delaware

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

2017 CIDA Standards Infused into Undergraduate Courses

GBCSL Presentation, Colombo

Residence Inn by Marriott, Stamford CT BREADTH STUDY: MECHANICAL REDESIGN

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Campus Sign Plan. Adopted by the Campus Planning Committee Adopted: June 26, 2006 Revised: April 14, 2016

Sheridan Boulevard S TAT I O N A R E A P L A N S H E R I D A N B O U L E VA R D S TAT I O N A R E A P L A N

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

Technical Assignment 3

Technical Report 1 Part 2

Architectural Engineering Senior Thesis Mechanical System Redesign

Queens Quay East & Lake Shore Boulevard East & 26 Richardson Street Public Art Plan

Hotel and Conference Center. AE481W AE482 Revised Thesis Proposal

Lighting Depth Study. Exterior Departure/Canopy Area

Compact Residential Development Beijing

BEFORE THE ENVIRONMENT COURT I MUA I TE KOOTI TAIAO O AOTEAROA ENV-2018-AKL IN THE MATTER. of the Resource Management Act 1991 (RMA) AND

Technical Report I. jack risser lighting/electrical. s. good the nerman museum. overland park, kansas sept 16 th, 2013.

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Transcription:

Lighting Redesign Allen Walker Senior Thesis 2008 Advisors: Dr. Mistrick Professor Dannerth

Presentation Outline Building Overview Lighting Depth Main Entrance Courtyard Painting Studio Entry Lobby Exhibit Gallery Electrical Depth Phot0voltaic Array Energy Efficient Transformers Structural Breadth Acoustical Breadth Conclusions *Topics not covered in this presentation

Building Overview Location: Fairfax, VA Size: 88,902 ft 2 Cost: $20.5 million Function: To house the Art & Visual Technology department whose curriculum spans from metal working to sculpting to painting. The building will also feature an exhibit gallery to host student and professional collections and also provide space for general education Scheduled to open in 2009

About the Art & Visual Technology Department The Department of Art and Visual Technology s primary purpose p is to foster the conceptual and technical education of the artist in a highly professional and studio-oriented environment. Believing that the artist's success is dependent on both creative vision and technical expertise, the Department encourages excellence, critical inquiry, and experimentation. - Harold Linton, Chair Department of Art and Visual Technology -24 full-time & 25 part-time faculty. 550 students

Lower Level Floor Plan

Entry Level Floor Plan

Upper Level Floor Plan

Lighting Depth

Main Entrance Courtyard Design Goals Create a sense of space and identity for the building and department Highlight g department logo on ornamental banner Assist in way finding

Main Entrance Courtyard Lighting Layout

Main Entrance Courtyard

Main Entrance Courtyard

Main Entrance Courtyard

Main Entrance Courtyard Summary Use of LED fixtures creates a sense of place for the department and building while providing a visual cue to the entrance of the building Illuminance levels Pedestrian walkway Avg. 1.7 fc (0.5 fc target) t) Building Entrance Avg. 2.9 fc (3 fc target) ASHRAE 90.1 1866W used > 1641W allowed

Painting Studio Design Goals Create a flexible lighting design that integrates high quality daylight with the electric lighting Allow the ability to give occupants of the space to create a multitude of appearances to the object being painted Utilize daylight to decrease the dependence on electric lighting Provide high uniform light levels on the work surface (easels)

Painting Studio Existing Conditions

Painting Studio

Painting Studio Lighting Layout

Painting Studio Control Scheme Zone 1 Zone 4 Zone 2 Zone 5 Zone 3

Painting Studio

Painting Studio Daylight Study (SkyCalc) Diffuse skylight glazing assembly Visible Transmittance 34% U-Value 0.2 SHGC 0.32 2,500 kwh/yr saved per room 10,000kWh/yr total savings 30% decrease in electric light needed May 5 th 11:00am

Painting Studio Summary High quality of daylight achieved through implementation of skylight system Control system allows for complete control over the appearance of the space Illuminance levels Avg. 25-30 fc on easel (30fc target) ASHRAE 90.1 2,088W used <2,124 W permitted

Electrical Depth

Photovoltaic Array Study Design Goals Establish the effectiveness of a photovoltaic array in Fairfax, VA To determine the cost feasibility of the installation of a photovoltaic array on the roof of the A&VT building.

Photovoltaic Array Study Design Parameters Product analyzed 170W monocrystalline PV module Fairfax, VA weather climate Possible Federal & State t incentives Utility Rate:.272 /kwh

Photovoltaic Array Study Results (RetScreen Analysis)

Structural Breadth

Structural Breadth Design Goals Redesign the roof framing to support the new skylight system Limit any construction impacts Reduce tonnage of steel number of connections

Structural Breadth Existing Framing System

Structural Breadth Existing Clerestory Section Detail

Structural Breadth Redesigned Framing System Existing Member New Member

Structural Breadth Skylight Section Detail

Structural Breadth Steel Comparison Existing Framing System Member Size Linear Feet Weight lb/linear ft total weight (lbs) w12x14(b3) 71.00 14.00 994.00 w21x44 320.00 44.00 14,080.00 w12x19 64.00 19.00 1,216.00 w18x40 120.00 40.00 4,800.00 w8x15 340.00 15.00 5,100.00 TS12x6x3/8 248.00 42.70 10,589.60 L3x3x3/8 264.00 7.17 1,892.88 TS8x4x3/8 88.00 27.40 2,411.20 WT6x15 53.30 15.00 799.50 TS6x4x3/8 150.00 22.30 3,345.00 total tons 22.61 *Connection Tonnage 4.52 **Price/ton 3,800.00 total Estimated Cost 103,120.25 New Framing System Member Linear weight total Weight Size Feet (lbs)/linear ft (lbs) w12x26 480.00 26.00 12,480.00 w18x40 320.00 48.00 15,360.00 w18x55 288.00 55.00 15,840.00 total tonage 21.84 *Connection Tonage (20%) 4.368 **Price/ton 3,800.00 total estimated cost 99,590.40

Conclusions Lighting Met design criteria through unique and creative solutions Able to provide target illuminances while meeting ASHRAE power density standards Electrical Due to extraordinary low utility rate and a lack of federal incentives, the implementation of a photovoltaic array is not recommended. Structural The redesign of the roof framing system effectively accommodates the new skylight system. A reduction in tonnage of steel and connections will lead to a A reduction in tonnage of steel and connections will lead to a cheaper and easier constructed roof.

Acknowledgements Thank you to all of those who helped and supported me throughout h t the journey that t has been thesis. The entire staff of Mueller Associates in particular Adam Fry Dr. Mistrick i Professor Dannerth Professor Moses Ling All of my AE friends especially my fellow lighting/electrical options Ashley Bradford Bryan Hart Antonio Verne Tom Yost who all provided me Ashley Bradford, Bryan Hart, Antonio Verne, Tom Yost who all provided me great advice on my structural breadth

Questions/Comments?