Sidekick II Receiver Model # SK2-SS 418MHz

Similar documents
Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Auto Dialer. Manual E-921APQ E-921GPQ

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

ERS-3600B. PERS-3600B Personal Emergency Reporting System

9 100% Recycled Paper

MEGA WAY LCD 4-CHANNEL MOTORCYCLE ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 3100 OPERATE 1

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Automatic Phone-Out Home Monitoring Systems

INSTRUCTION MANUAL PC255O

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

Fire Command Keypad. XR5 User s Guide

KA300TX / KA300RX / KBS300RX Alarm Monitor INSTRUCTION MANUAL PATENT PENDING

INSTRUCTION MANUAL PC255O

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Water Tank Level Monitor

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Home Doorway Alert Kit

System Introduction. 1.1 Specifications S E C T I O N 1

SR-i500 INSTALLATION MANUAL AND USER S GUIDE. FM 2-Way Security System. Setting Clock Time. Setting Alarm Clock. FCC Notice

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

NetworX NX-8V2. LED Keypad User Manual

MOBILE CALL GSM Alarm System User s Manual

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Dual Alarm Clock with Wireless Alarm Monitoring Receiver

Fire Command Center. XR2400F User s Guide

MiniAlarm Plus. Model MA-5000

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

U ser's Guide PC6010

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

DIY Home Security Support 30 numbers wireless sensors

Sound Soother 20 Soothing Sounds

Installation and ZONES: Operation Manual. Model: ON STI-34108

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Simon XTi Quick Operation Guide

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

X64 Wireless Training

TRUST WIRELESS ALARM SYSTEM 200S

Honeywell Temperature & Humidity Sensor with LCD

Security System. User s Guide for the Text Command Center

Operating Guide. English Version 3.3

Atomic Projection Alarm Clock

THE BELLMAN & SYMFON WAY Visit technical training

LCD and 16-Zone LED Keypads. User s Manual

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

Computer Room Guard Model VM Manual and Installation Instructions

Alarm System SECURE AS 302

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

FEATURES AND SPECIFICATIONS

WIRELESS COLOR FORECAST STATION

NETWORX TM. User manual NX-4

WM3000 WIRELESS MODULES

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

G4S SMARTalarm User Guide

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

1. Introduction. 2. Product overview

Watchguard WGAP864 User Manual

Complete Home Alerting Solution HA360MK Main Unit USER GUIDE

Wireless External Alarm

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

status AW1 Plus WiFi Alarm System User Manual

All-In-One Wireless Security System V1.0. Model #: MG-6060

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

Sonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3

System Introduction. 1.1 Specifications

WIRELESS COLOR WEATHER STATION

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

10-Zone Spectra LED Keypads

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

PiSector GSM Cellular Wireless Alarm System

Destiny Destiny Owners Manual

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Intruder alarm system Operating Instructions

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

INSPECTION AND TESTING FORM

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

ThinkPro Security and Automation Panel User Guide

Supervised Security System Owner's Guide

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

SECURITY SYSTEM NOTES

MLS. ALPHA-PAGE-LT v5.3. Contact monitoring-paging system. installation/owners manual #AP-LT53. Micro Logic Systems. phone 866-MLS-FREE

Model: C Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Document No

Transcription:

www.silentcall.com Sidekick II Receiver Model # SK2-SS 418MHz Signature Series

Sidekick II Signature Series Model # SK2-SS (418 MHz Receiver) Setup and Operation: 1. Plug the power supply pin jack into the connector located next to the Power ON/OFF switch on the back of the receiver. (see page 6 for diagram) Plug power supply into a wall electrical outlet. Battery Back-up Installation Instructions Your Sidekick II Signature Series Receiver comes with the battery back-up pre-installed at the factory. In the event that you need to re-install the battery pack, follow the instructions below. The battery compartment door is secured by one screw. To gain access to the battery compartment remove the screw (pg 6). Plug the female connector from the battery pack onto the male connector pin in the battery compartment. Be sure to line up the pins with the holes in the connector. It will only fit one way. Replace the battery compartment door and secure the screw. You will notice and On/Off switch on the right hand bottom corner of the battery compartment door (see pg 6). With the battery back-up installed and the back-up switch turn to the ON position, the Sidekick II s blue light (AC power indicator) will turn to an amber color when the unit goes into battery back-up mode because of a power failure. Turning the battery back-up power switch to OFF will turn off the battery back-up to the receiver and the clock. It is important that the battery back-up feature be turned ON for proper operation. The Ni-Cad battery is intended to keep the Sidekick II operational during a short term power outage for several hours without the strobe or vibrator operating. If both strobe and vibrator are operating, the battery back-up will operate the system for approximately 10 minutes. The battery back-up is automatically being charged when the Sidekick II power supply is plugged into a standard electrical wall outlet. The BATTERY ICON will display itself on the LCD screen once the battery back-up level has reached 2/3 of its discharge. However, the BATTERY ICON will not be displayed until this condition is reached. When the Amber LED is on but the BATTERY ICON is not displayed on the screen, this means that the battery is at a full or close to full charge. 2. Turn the Power ON by sliding the ON/OFF SWITCH on the back of the receiver to the ON position. The front panel display will show the time 11:59AM. A blue light will be visible from the Strobe lens. The blue light indicates that the unit s AC power is on. An amber light will appear if the unit is in battery backup mode. (If your unit is equipped with a battery back-up.) 3

3. Set Clock Time: Press and release the MODE pushbutton (the large button located at the lower right hand side on the unit). The Orange LED will light up to let you know that you are in Set Clock Time mode. 4. Press and release the minute button to set the minutes. Press and release the hour button to set the hour. 5. When you are finished setting the minutes and hours, press and release the MODE pushbutton three times to exit the Setup Mode. Note: Any time you unplug your Sidekick II Receiver from the wall outlet or turn the power off, the next time you turn your Sidekick II Receiver on again, you will need to reset the clock. If you are using the Battery Backup feature, you will not need to do this. 6. All of your Signature Series transmitters come pre-programmed from the factory to work with your Sidekick II Signature Series Receiver. If you need to set your transmitters to a different address, please refer to the section in this manual on programming transmitters. The only reason you would need to do this is if someone in your area is using Silent Call products and they are interfering with your products or if you want to use the Supervision Capability with your Silent Call Smoke Detectors or Fire Transmitters. Setting Alarm Clock: 1. Press and release the MODE push button twice. 2. The Green LED will light up indicating that you are in the SET UP mode. The display will show the present Alarm Clock Time setting. 3. Press and release the MINUTES button to set minutes and press and release the HOURS button to set the hours. 4. Once the Alarm Clock Time has been set, press the MODE button 2 times to exit the SET UP mode. 5. When your alarm is activated the strobe light and bell icon will flash and the bed vibrator (optional) will shake. 6. To turn the ALARM on or off, press and release the Alarm Clock button. When the alarm is turned ON the BELL ICON will appear on the screen. 4

LCD Display: The LCD Display screen is back lighted. The back light brightness is automatically controlled by the light level in the room. When the room becomes dark, the back lighting comes on. When the room becomes light, the back lighting goes off. Telephone Direct Interface: The Sidekick II Signature Series Receiver has the ability to plug a standard telephone line directly into the receiver using the supplied telephone wire and dual connector and it will notify you each time the telephone rings. Plug the dual connector into your phone jack wall outlet. Then plug the wire from your telephone into one side of the dual connector. Next, take the telephone wire that came with your Sidekick II Signature Series Receiver and plug it into the other side of the dual connector (See illustration #1.) Finally, plug the other end of that cable into the back of the Sidekick II Signature Series Receiver (See illustration #2.) The receiver will notify you in the same way as if you were using a Telephone Transmitter (see section on Notifications). Illustration #1 5 Illustration #2

Remove screw to gain access to battery backup compartment. 2 AAA Batteries Clock Battery Backup Accessory Battery Backup 12V NI-CAD 300mA Compartment & Connector Battery Backup On/Off Switch On/Off Switch Power Supply Terminal Telephone Interface Input Vibrator Jack Antenna 6

Transmitters When the Sidekick II Signature Series Receiver detects an incoming signal from any of the Signature Series transmitters it will notify you by: Transmitter Type Icon Notification Alarm Clock Bell Icon, Strobe flashes (Vibrator Optional) Sound Monitor Transmitter Telephone Transmitter Doorbell Transmitter Door/Window Access Transmitter Sound Icon, Orange LED, Strobe flashes (Vibrator Optional) Phone Icon, Green LED, Strobe flashes (Vibrator Optional) Door Icon, Yellow LED, Strobe flashes (Vibrator Optional) Door Icon, Yellow LED, Strobe flashes (Vibrator Optional) TransMATTer Transmitter Door Icon, Yellow LED, Strobe flashes (Vibrator Optional) Weather Icon, 2nd Red LED, Strobe flashes (Vibrator Weather Alert Transmitter Optional) Carbon Monoxide Transmitter CO CO Icon, 2nd Red LED, Strobe flashes (Vibrator Optional) Smoke or Fire Transmitter Fire Icon, 4th, 5th, or 6th Red LED, Strobe flashes (Vibrator Optional)* *See information on Supervision Mode for more information on LED indicators. If you are using the optional Bed Vibrator and your Sidekick II Signature Series Receiver detects an incoming signal from any of the Signature Series transmitters, along with the above Notifications, the bed vibrator will also pulse in a specific way for each transmitter. Transmitter Type Pulse Pattern Short Pulse Long Pulse Alarm Clock Two Short Pulses and One Long Pulse Sound Monitor Transmitter Three Short Pulses Telephone Transmitter One long pulse Doorbell Transmitter Two Short Pulses Door/Window Access Transmitter Two Short Pulses TransMATTer Transmitter Two Short Pulses Weather Alert Transmitter One Short Pulse and One Long Pulse Carbon Monoxide Transmitter Three Short Pulses and One Long Pulse Smoke or Fire Transmitter Continuous Short Pulses 7

Transmission Range: Transmission range refers to the distance a Silent Call Transmitter can communicate with the Sidekick II Signature Series Receiver. Range is measured in an outdoor environment without obstructions from metal objects or buildings. The range for the Sidekick II Signature Series Receiver is up to 2000 feet. The actual range inside a building will vary depending on many factors outside of one s control. Cancelling An Incoming Alert To cancel an alert, press and release the mode button once. Programming the transmitters: All Signature Series Transmitters come pre-programmed at the factory. You do NOT need this step unless you need to change the address due to someone in your area that has Silent Call products and they are interfering with your equipment OR if you want to use the Supervision Mode with your smoke detectors. 1. Make sure that all Silent Call transmitters in the area are turned off. 2. Perform the ALL ERASE function (see pg 9) 3. Select the transmitter you wish to program with the Sidekick II Signature Series Receiver. It is important to program the Smoke Detector and Fire transmitters first because of the supervision capability. 4. Located on the back of the transmitter case is a removable access panel. Remove the access panel and take out the batteries. 5. Locate the switch on the transmitter circuit board that has 5 small dip switches. 6. Set the switches to any combination that you want. For Example: 1, 2 On 3, 4, 5 OFF. (Do not set them to all ON or all OFF as this can cause interference). This gives your transmitter an address. Note that you MUST remove the batteries first or the switch setting will not take effect. 7. Reinstall batteries and replace the access panel. 8. Make sure that the transmitter is near the Sidekick II Signature Series Receiver. 9. On the Sidekick II Signature Series Receiver, press and release the MODE pushbutton until the Yellow LED lights up and PPP is displayed on the screen. This means you are now in program mode. 10. Press the test button on the transmitter so that it sends a signal to the Sidekick II Signature Series Receiver. The unit will flash its strobe, turn on the appropriate LED and display Icon for the transmitter that you used. Your transmitter is now programmed to work with your receiver. 8

11. Repeat the above steps ONLY if the other transmitters are set to a DIFFERENT address setting than the transmitter you just programmed. We recommend keeping all of your transmitters set to the same address to reduce interference from other Silent Call systems that may be in your area. All Erase: Provisions are made to erase all programmed transmitter addresses. The only time you would need to use the ALL ERASE feature is if you are receiving signals from another Silent Call System in your area. You would then do the ALL ERASE feature on your receiver and then re-program your transmitters to a different address. The ALL ERASE function is performed as follows: 1. Turn off the Sidekick II Signature Series Receiver by turning the AC power switch to the off position. Turn back-up battery to off position (if you have the backup battery installed). An indication of power being off would be that the blue and amber light on the strobe lens is off. 2. Press and hold the MINUTES pushbutton DO NOT RELEASE THE BUTTON 3. Turn the power back on while holding the MINUTES pushbutton in. 4. Once power is on, release the MINUTES pushbutton. The all erase function is complete and the unit will now need to be re-programmed with its transmitters. The Supervisor MODE is also disabled. Please Remember to program the smoke detectors and fire transmitters before programming any other transmitters. Supervision Mode for Smoke and Fire Transmitters: The Sidekick II Signature Series is capable of monitoring up to three Silent Call Smoke Detectors and/or Fire transmitters for low battery, out of range, interference from outside sources, and missing or failure of the transmitter to communicate with the receiver. The MODE is referred to as the SUPERVISOR MODE. All 418 MHz Signature Series Silent Call Fire and Smoke Detector transmitters send out a special alarm signal at two minute intervals. The receiver will continue to operate in its normal mode provided the unit is receiving the supervisory alarm signals from the Smoke or Fire transmitter. The receiver will alert the user if a Smoke Detector or Fire transmitter signal has not been received within a period of 10 minutes. When this happens, the LCD will flash the FIRE ICON and the CHK ICON for 10 seconds every 30 seconds. Also, the RED LED that corresponds to the transmitter that is having the problem will light up and that is how you will know which unit is having a problem. The Sidekick II Signature Series Receiver automatically enters the supervisor mode once it has been programmed for a smoke detector or fire alarm transmitter. 9

Each Smoke Detector or Fire alarm transmitter must be assigned an address different from all other transmitters. For example, if two smoke detectors and one fire alarm transmitters are being used, they may be assigned address #1 (1 OFF and 2, 3, 4, 5 ON); address #2 (1 ON, 2 OFF, 3, 4, 5 ON); address #3 (1, 2 ON, 3 OFF, 4, 5 ON). Once programmed for the Smoke Detectors and Fire alarm transmitters, the receiver automatically assigns each transmitter a location on one of the three RED LED s located on the Front Panel, right side. The red LED located furthest left of the three is assigned the first Smoke Detector or Fire alarm program. The second Red LED, the second Smoke Detector or Fire alarm programmed and the third Red LED, the third Smoke Detector or Fire alarm programmed. Once installed and operating correctly, the transmitters can be identified by location. For Example, a smoke alarm on LED # 1 may represent the bedroom, a smoke alarm on LED # 2 may be located in the basement and a smoke alarm on the LED # 3 may be located in the garage. Low battery notification: The Silent Call Signature Series Transmitters, operates on two AA batteries and has a built in low battery sensor. The transmitters will send out a special low battery signal whenever the low battery condition exists. When the Sidekick II Signature Series Receiver detects the signal it will display the condition by turning on the units ALARM LED and displaying the ALARM ICON along with the CHK ICON. For example, a smoke detector battery is low. The smoke detector or fire alarm transmitter sends a signal to the Sidekick II Signature Series Receiver about its battery condition. The receiver will display the FIRE ICON, the CHK ICON, and turn on the FIRE LED. The unit will not turn on the Strobe or Vibrator. The display will continue to show the low battery condition until the problem is resolved. Once resolved, the transmitter will no longer send the low battery alarm. Technical Support For technical support on this or any other Silent Call product, please feel free to contact us. You can reach us by phone at 800-572-5227 (voice or TTY) or by Email at support@silentcall.com Limited Warranty Your Silent Call product is warranted to be free of defects in material and workmanship for five years from the date of initial purchase. During that time, the unit will be repaired or replaced free of charge when shipped prepaid to Silent Call Communications. This warranty is void if the defect is caused by customer abuse or neglect. We honor the smoke detector manufacturer s warranty for their smoke detector. Only Silent Call products are warranted for 5 years. 10

11

5095 Williams Lake Road Waterford, MI 48329 Phone 800-572-5227 v/tty www.silentcall.com