Oxylog VE300 Emergency & Transport Ventilation

Similar documents
Oxylog VE300 Emergency & Transport Ventilation

Oxylog VE300 Emergency & Transport Ventilation

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Oxylog 2000 plus Pocket Guide Software version 1.n

Dräger Pac 6000 Single-Gas Detection Device

Dräger Pac 5500 Single-Gas Detection Device

Dräger Pac 8500 Single-Gas Detection Device

Dräger Pac 8000 Single-Gas Detection Device

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Pac 3500 Single-Gas Detection Device

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Bodyguard 1000 Warning Device

Dräger Polytron 5720 IR Toxic Gas Detection

Training Gas Detection Level 3 Maintenance and Repair

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Configuration and Evaluation Software

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Bump Test Station Calibration and Bump Testing

Dräger OR Lights Simply good light

Dräger X-am 2500 Multi-Gas Detector

Dräger Pac 7000 Single-Gas Detection Device

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger REGARD -1 Control System

Training Authorised Gas Tester Level 1. Basic Information

Dräger VVP 1000 System Components

Tropic 2.0 ultrasonic nebuliser

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger X-pid 9000 / 9500 Multi-Gas Detection

On-site & Shutdown Safety Service CSE Monitoring

Dräger REGARD 3900 Series Control System

Dräger X-am 5000 Multi-Gas Detector

VarioVac vacuum regulators Consumables and Accessories

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 7000 Detection of toxic gases and oxygen

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection

Dräger Catalytic Ex-Sensors DrägerSensors

D Moving beyond telemetry INFINITY M300

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger FRT 1000 / ETR 1000 Location Devices

Powder Extinguisher ABC - composite Portable powder extinguishers

Portable wet chemical extinguishers

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Infinity M300+ Telemetry

PRODUCT SPECIFICATIONS VENTILATOR Aeros-4600

Dräger QuadGard Control System

Dräger Flame 5000 Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger P4000 Pressure and Leak Testing

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Dräger GS01 (wireless) Detection of flammable gases and vapours

GS01 (wireless) Detection of flammable gases and vapours

Dräger Pac 3500 Single-Gas Detection Device

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Dräger X-am 7000 Multi-Gas Detection

Dräger Flame 5000 Flame Detection

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger PIR 7200 Detection of toxic gases and oxygen

Carina Guidelines. The Carina Guidelines are not a replacement or substitute for the Instructions for Use.

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Dräger Flame 2100 (UV) Flame Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Pac 6000 Single-Gas Detector

Dräger Pac 8500 Single-Gas Detector

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger X-zone 5500 Area Monitoring

Dräger REGARD -1 Control System

Dräger X-am 5000 Multi-Gas Detection

Dräger PIR 7000 Flammable Gas Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Flame 2370 (UV&IR) Flame Detection

Quick start guide. English

Quick setup guide. English

Dräger Flame 2500 (IR3) Flame Detection

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

Dräger REGARD -1 Control System

MT Always in focus BABYTHERM

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

Dräger UCF 7000 Thermal Imaging Camera

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

CLEO VERSATILITY IN VITAL SIGNS

The SharpEye 40/40R (IR) Flame Detection

Transcription:

Oxylog VE300 Emergency & Transport Ventilation The straightforward and user-friendly Dräger Oxylog VE300 is built to face your challenges in preclinical emergency services With reliable ventilation technology, robustness and intuitive operation, it provides you with reliable and safe assistance in an emergency D-128-2017

02 Oxylog VE300 Benefits Simple, ergonomic, robust and economical: Reliable even under extreme operating conditions (-20 to +50 C) Three step device start up, takes less than 10 seconds Device check takes less than a minute Preset parameters for fast ventilation start Replaceable and rechargeable battery for up to 9 hours of operation Low oxygen consumption thanks to DuroFlow technology* Clear user guidance with moderate training time Easily accessible documentation with Bluetooth and USB interface: patient data, system test, screen shots Wall mount permits flexible positioning Practical extras available as options: belt, stretcher mounting, accessory bag, battery charger Ergonomic carrying handle directly above the device s centre of gravity Easy to carry, quick-start ventilation Clear colour touch screen Flip-screen button rotates the display 180 Volume-controlled ventilation: VC-CMV / VC-AC, VC-SIMV Pressure-controlled ventilation: PC-BIPAP** Spontaneous breathing support: SPN-CPAP/PS with NIV Pressure support: PS CPR mode can be selected with a single keystroke Capnography: main-stream CO₂ measurement Logbook supports documentation *DuroFlow technology: based on the Venturi-Principle without additional base flow ** trademark used under license

Oxylog VE300 03 Related Products Dräger Oxylog 3000 plus MT-5809-2008 Offering high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation, the compact and robust Oxylog 3000 plus helps you transport your patients safely and provides feedback on correctness of intubation and ventilation effectiveness The Oxylog 3000 plus gives you confidence to master even the most demanding situations

04 Oxylog VE300 Technical Data Device specifications Dimension (W x H x D) Main device Main device, with carrier system Weight Main device, without battery Main device, with battery Main device, with carrying system, battery and bag Screen Technology Size External connections USB Sound pressure level (SPL) Average sound pressure level Leq(A) (Free-field measurement at 1 m distance according to ISO 3744, with typical ventilation): Sound pressure level L(A) of alarm signals (measured according to IEC 60601-1-8) 399 x 153 x 160 mm (157 x 68 x 63 inches) 607 x 228 251 x 166 mm (239 x 90 99 x 65 in) Approx 33 kg (73 lb) Approx 36 kg (79 lb) Approx 56 kg (124 lb) TFT colour screen 43 inch 20 Only connect passive storage media, ie devices that do not have a separate power supply 45 db(a) Approx 47 to 83 db(a), depending on alarm priority Ambient conditions Operating conditions Temperature (device) Temperature (power supply) Permissible operating temperature during charging Ambient pressure (device) Height above sea level Ambient pressure (power supply) Relative humidity -20 C to +50 C (-4 to +122 F) 0 C to +50 C (+32 F to +122 F) 0 to +45 C (+32 to +113 F) 620 to 1,100 hpa (899 to 1595 psi) Automatic ambient pressure compensation within this pressure range Up to 4,000 m (13,123 feet) 700 to 1,200 hpa (1015 to 1595 psi) 5 to 95% (without condensation) Settings Ventilation modes Optional Respiratory rate RR VC-CMV, VC-AC, SPN-CPAP VC-SIMV/PS, PC-BIPAP, SPN-CPAP/PS Adults: 2 to 50 /min (VC-SIMV) Adults: 5 to 50 /min (VC-AC, VC-AC) Child: 2 to 50 /min (VC-SIMV, PC-BIPAP) Child: 10 to 50 /min (VC-CMV, VC-AC) Maximum airway pressure Pmax 20 to 60 mbar (20 to 60 cmh 2 O) Ratio of inspiration time to expiration time I:E 1:4 to 4:1 Inspiration time Ti Tidal volume VT 03 to 10 s Adult: 01 to 20 L, BTPS Child: 01 to 04 L, BTPS Measured values based on patient's lung conditions, body temperature 37 C (986 F), ambient pressure, water vapour-saturated gas

Oxylog VE300 05 Technical Data O 2 concentration 100% O 2 and O 2 /air mixture Actual value depends on inspiratory flow and mean airway pressure Positive end-expiratory pressure PEEP 0 to 20 mbar (0 to 20 cmh 2 O) Trigger sensitivity (flow trigger) Trigger sensitivity (pressure trigger) Pressure support ΔPsupp Off or 3 to 15 L/min Off or 3 to 15 steps 0 to 35 mbar (0 to 35 cmh 2 O) (relative to PEEP) Pressure rise time for pressure support slow (1 s), standard (04 s), fast (<04 s) Regions of alarm limits MVe high MVe low RR high etco 2 high etco 2 low 2 to 60 L/min 05 to 40 L/min 10 to 99 /min 5 to 99 mmhg / 05 to 132 kpa / 05 to 132 vol% 0 to 94 mmhg / 0 to 127 kpa / 0 to 127 vol% Performance characteristics Control principle Maximum inspiratory flow 100 L/min 1 Device compliance Time-controlled, constant volume, pressure monitored with 15 m breathing tube < 15 ml/mbar (15 cmh 2 O) with 30 m breathing tube < 2 ml/mbar (2 cmh 2 O) Inspiratory and expiratory resistance of the device with breathing tube system, with Plus option Inspiratory and expiratory resistance of the device with breathing tube system, without Plus option Emergency air valve Safety valve < 6 mbar (6 cmh 2 O) at 60 L/min < 4 mbar (4 cmh 2 O) at 30 L/min < 2 mbar (2 cmh 2 O) at 5 L/min < 6 mbar (6 cmh 2 O) at 60 L/min < 4 mbar (4 cmh 2 O) at 30 L/min < 2 mbar (2 cmh 2 O) at 5 L/min Opens breathing system if there is insufficient gas and enables spontaneous breathing with room air Opens breathing system if device fails at about 80 mbar (80 cmh 2 O) 1 At supply pressure > 350 kpa (5076 psi) At a supply pressure < 350 kpa (5076 psi), the maximum inspiratory flow is reduced to 80 L/min, at a supply pressure < 280 kpa (4061 psi) to 39 L/min Values displayed Airway pressure measurement 0 to 100 mbar, BTPS Resolution 1 mbar (1 cmh 2 O) Accuracy ±(2 mbar (2 cmh 2 O) +2% of measured value) Flow measurement Minute volume MVe Resolution Accuracy Tidal volume VTe Resolution Accuracy 0 to 100 L/min, BTPS 01 L/min ± 20% of measured value or ± 04 L/min, the larger value applies 0 to 5,000 ml, BTPS 1 ml ± 20% of measured value or ± 20 ml, the larger value applies (adults-breathing tube)

06 Oxylog VE300 Technical Data CO 2 measurement (option) Measurement basis Resolution Respiratory rate measurement Resolution Accuracy Main-stream method 0 to 100 mmhg / 0 to 132 vol% / 0 to 133 kpa 1 mmhg / 01 vol% / 01 kpa 0 to 99 /min 1 /min ±1 /min Graph Airway pressure Paw (t) 0 to 90 mbar (0 to 90 cmh 2 O) CO 2 0 to +100 mmhg / 0 to +15 vol% / 0 to +15 kpa Monitoring Expiratory minute volume MVe (option) Alarm, upper alarm limit If the upper alarm limit has been exceeded 2 to 60 L/min Alarm, lower alarm limit Apnoea Alarm Respiratory rate RR Alarm, upper alarm limit If the value has fallen below the lower alarm limit 05 to 40 L/min 40 seconds after start of ventilation If no respiratory phase change for > 15 seconds is detected If the upper alarm limit has been exceeded 10 to 99 /min 30 seconds after start of ventilation End expiratory CO 2 concentration etco 2 (option) Alarm, upper alarm limit Alarm, lower alarm limit Leakage Alarm Disconnection Alarm If the upper alarm limit has been exceeded 5 to 99 mmhg / 05 to 132 kpa / 05 to 132 vol% 30 seconds after connection and calibration If the value has fallen below the lower alarm limit 0 to 94 mmhg / 0 to 127 kpa / 0 to 127 vol% 30 seconds after start of ventilation, connection and calibration Only for Plus option in VC modes and deactivated NIV in CPAP: If VTe < 45% of VTi 30 seconds after start of ventilation If disconnection of the breathing circuit is detected 30 seconds after start of ventilation

Oxylog VE300 07 Technical Data Data communication (option) Exported data Measured values Waveforms Alarm messages Alarm settings User settings System test information Screenshots Operating data Power supply Input Voltage Duration of operation Power consumption Battery type Charging time 19 V + 5/-3 VDC Power supplies (power supply unit and DC converter) are specified as parts of the Oxylog VE300 With new and fully charged battery, without external power supply: 8 hours with typical ventilation (VC-CMV, RR = 12/min, VT = 500 ml, PEEP = 5 mbar (5 cmh 2 O), I:E = 1:2) 9 hours (without CO 2 sensor and at reduced screen brightness) While charging: max 20 A at 19 VDC With typical ventilation: max 08 A at 19 VDC Lithium-ion battery Approx 5 hours The specified charging time applies when recharging the battery completely after it has been depleted Power supply unit Protection class (according to IEC 60601-1) Degree of protection Input Class II IP22 100 to 240 V~ / 50/60 Hz / 10 A Output 19 V / 447 A (0 to +40 C (32 to +104 F)) / 357 A (+40 to +50 C (+104 to 122 F)) To disconnect the ventilator from the power supply, disconnect the power cable from the power socket The power supply unit is intended for indoor use only (eg in hospitals or fire stations) Fuses F1 and F2 T 25 AH/ 250 V~ Gas supply Oxygen supply pressure Gas characteristics Connection to the oxygen supply: From a central gas supply system or an oxygen cylinder 270 to 690 kpa (3916 to 10008 psi) Medical oxygen, 93% oxygen NIST (Non-Interchangeable Screw-Threaded) according to EN 739 / ISO 5359 or DISS (Diameter Index Safety Systems) according to CGA V5-1989 or NF (Norme française) S90-116 Specific quick connection

08 Oxylog VE300 Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status 91 04 149 1804-3 HQ PP Subject to modifications 2018 CORPORATE HEADQUARTERS Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Manufacturer: Moislinger Allee 53-55 23542 Lübeck, Germany REGION DACH Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION MIDDLE EAST, AFRICA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL 59 East Street, Nuevo Paitilla House 30, San Francisco Town Panama City, Panama Tel +507 377 9100 Fax +507 377 9130 servicioalcliente@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact