Betriebsanleitung Operating Instructions

Similar documents
Operating Instructions

Operating Instructions

Operating Instructions TSF 010. Power Failure Venting Unit PM BNE/L (0007)

Operating Instructions

Betriebsanleitung Operating Instructions

Operating Instructions

Betriebsanleitung Operating Instructions. Diaphragm Pumps

Betriebsanleitung Operating Instructions

Betriebsanleitung Operating Instructions

Operating Instructions

A New Generation of Two-Stage Rotary Vane Pumps!

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

All-Metal Control Valve

OPERATING INSTRUCTIONS HICUBE PRO. Turbo pumping station. Translation of the original instructions PT 0265 BEN/E (1602)

TMH 260 / TMU 260 TMH 260 P / TMU 260 P

Technology for Vacuum Systems. Instructions for use

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Operating Instructions incl. Manufacturer's Declaration. Diffusion pump. with optional baffle DIF 501 BP BE (0003) 1

Betriebsanleitung Operating Instructions

Laboport Chemically-resistant Laboratory Pumps and Systems

Operating Instructions

Diaphragm pump 4 - headed

Oil-Sealed Rotary Vane Pumps

Operating manual Incl. Manufacturer s declaration. Diffusion pump. with optional baffle DIF 320 BP BE (9906) 1

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

Operating instructions

Installation and maintenance instructions

Betriebsanleitung Operating Instructions

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Operating Instructions

Operating Instructions

Installation and maintenance instructions

BK 45 BK 45-U BK 45-LT BK 46

OPERATING INSTRUCTIONS HIPACE 700. Turbopump. Translation of the original instructions PT 0209 BEN/I (1604)

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Operating Instructions

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

OPERATING INSTRUCTIONS

Betriebsanleitung Operating Instructions. Compact Turbo TurboDrag Pump

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Karlsruher Glastechnisches Werk KGW-ISOTHERM

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

TMH 520 / TMU 520 TMH 520 P / TMU 520 P

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Overpressure Leak Detector

Original Operating Instructions V-VC

OPERATING INSTRUCTIONS HIPACE Turbopump. Translation of the original instructions PT 0240 BEN/H (1603)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Original Operating Instructions V-VCA / V-VCE

Betriebsanleitung Operating Instructions. Compact Turbo TurboDrag Pump

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Installation and Operating Instructions

Operating Instructions

Basically, the instruction handbook shall contain the following information:

Friwa Compact. Operating instructions EN

INSTRUCTION MANUAL MODEL: 690E

Installation and Maintenance Instructions

cooled, Non-heated ATH 1603 M, DN 200 CF-F, External drive electronics, Water cooled, Non-heated

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

Operating manual Incl. Manufacturer s declaration. Diffusion pump. with optional baffle DIF 630 BP BE (9803) 1

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

Installation instructions Air drying unit for Bubble Sensor OTT CBS. English

Original Operating Instructions V-VTE

Aquamax KF Oil Evaporator. User Manual

HKF 8180 Operating instructions

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

GB162 Concentric Horizontal Vent Kit

O 2. Installation and Operating Instructions. Vacuum Pumps R 5, RA 0155 A Oxygen. with Operating Fluid YLC 250 B

Operation Manual. Scroll pumps. Dry Run II

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Instructions

Vacuum Controller with Control Unit VC 900

INSTRUCTION MANUAL W-400

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Instruction Manual. Vapour Pump Thermal Snap-Switches. Cooling-Fail Thermal Snap-Switch

ASSEMBLY & OPERATING INSTRUCTIONS

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Mechanical seals external, single or double, to DIN EN 12756

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Model: 1100 Float-Controlled Condensate Trap, PN 25

Instruction manual ASPIMAX 16

Helium Leak Detection Systems

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Supplemental Installation & Operation Manual. THE COLDWELL Stainless Steel Cold Trap

MP 2401 E, MP 1801 Z, MP 1201 T

Operating Instructions and Spare Parts List. ZR Monocyclone. Issued 09/01. ZR Monocyclone 9

Aluminum Heating Mantles

ST1. Mod. USE AND MAINTENANCE MANUAL

SFE 2311BK. EN Desktop Fan. Copyright 2017, Fast ČR, a.s

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Transcription:

Betriebsanleitung Operating Instructions Oil mist filter idealvac.com (505)872-0037 idealvac.com ONF 16 PK 0213 BE/G (0811) ONF 25/25L/25XL

Table of contents Table of contents 1 About this manual...................................... 3 1.1 Validity................................................ 3 1.2 Conventions........................................... 3 2 Safety................................................ 4 2.1 Safety precautions...................................... 4 3 Transport and storage.................................. 5 3.1 Storage............................................... 5 4 Product description.................................... 5 4.1 Product identification..................................... 5 4.2 Function.............................................. 6 5 Installation............................................ 7 5.1 Assembly.............................................. 7 5.2 Installing the oil return line................................. 8 6 Operation............................................. 9 7 Maintenance.......................................... 10 7.1 Draining the operating fluid............................... 10 7.2 Changing and cleaning the filter insert...................... 11 8 Service.............................................. 13 9 Accessories.......................................... 14 10 Technical data........................................ 14 10.1 Dimensions........................................... 15 11 Spare parts.......................................... 16 11.1 Spare parts packages................................... 16 12 Disposal............................................. 17 2

About this manual 1 About this manual 1.1 Validity This operating manual is for customers of Pfeiffer Vacuum. It describes the functioning of the designated product and provides the most important information for safe use of the unit. The description follows applicable EU guidelines. All information provided in this operating manual refer to the current state of the product's development. The documentation remains valid as long as the customer does not make any changes to the product. Up-to-date operating instructions can also be downloaded from www.pfeiffer-vacuum.net. 1.2 Conventions Safety instructions The safety instructions in Pfeiffer Vacuum operating manuals are the result of risk evaluations and hazard analyses and are oriented on international certification standards as specified by UL, CSA, ANSI Z-535, Semi-S1, ISO 3864 and DIN 4844. In this document, the following hazard levels and information are considered: DANGER Immediate danger Death or very severe injuries occur. WARNING Possible danger Death or injuries may occur. CAUTION Possible danger Medium to slight injuries may occur. NOTE Command or note Command to perform an action or information about properties, the disregarding of which may result in damage to the product. Pictogram definitions Prohibition of an action or activity in connection with a source of danger, the disregarding of which may result in serious accidents. Warning of a displayed source of danger in connection with operation of the unit or equipment. Command to perform an action or task associated with a source of danger, the disregarding of which may result in serious accidents. 3

Safety Instructions in the text Work instruction: here you have to do something. Abbreviations used ONF: Oil Mist Filter ORF: Oil Return Device 2 Safety 2.1 Safety precautions NOTE Duty to inform Each person involved in the installation, operation or maintenance of the vacuum pump must read and observe the safety-related parts of these operating instructions. The operator is obligated to make operating personnel aware of dangers originating from the vacuum pump, the pumped medium and the entire system. Vor allen Arbeiten die Betriebsanleitung und Sicherheitshinweise zum Pumpstand und den Einzelkomponenten lesen und beachten. Connection to pumps or units which are not suitable for this purpose according to their operating instructions. Connection to units which have exposed voltage-carrying parts. Observe the safety and accident prevention regulations. Check regularly that all safety precautions are being complied with. When returning the components to us please note the instructions in the Service section. The use of accessories, which are not named in this manual. 4

Transport and storage 3 Transport and storage 3.1 Storage The ONF should be stored dry and protected from moisture. The filter inserts can absorb moisture, and the lubrication properties of the oil and hence the end pressure can be negatively influenced in pumps with an oil return unit. 4 Product description 4.1 Product identification To correctly identify the product when communicating with Pfeiffer Vacuum, always have the information from the rating plate available. Model and model number Date of manufacture D-35614 Asslar Mod.: ONF 025 Mod.-No.: PK Z40 157 Made in Germany 2008/03 Fig. 1: Product identification on the rating plate (example) Variants Type Connection nominal intended for pump type diameter ONF 16 DN 16 ISO-KF UNO 2.5, UNO 5, DUO 2.5, DUO 5 M ONF 25 DN 25 ISO-KF DUO 10 M, Penta 10 ONF 25L DN 25 ISO-KF UNO 30, DUO 20 M, Penta 20, TWIN 20-10 ONF 25XL DN 25 ISO-KF Penta 35 Connection nominal diameter 5

Product description 4.2 Function The oil mist filter is mounted on the exhaust connection of rotary vane pumps. It prevents air pollution from operating fluid mist that is ejected by the pump to a greater or lesser degree depending on the operating pressure. The filter inserts are installed in a housing made of corrosion-resistant aluminum and consist of a cylindrical filter of glass polyester fleece. The filter inserts are opened by an incorporated pressure relief valve when the contamination becomes excessive so that the maximum working pressure of 1.5 bar (absolute) cannot be exceeded. The collected operating fluid can be observed through a sightglass and discharged with a drain screw. 2 2 Housing ONF 4 Cover 10 Connection flange (exhaust flange of rotary vane pump) 12 Sight glass 30 O-ring 33 Operating fluid drain screw 33 12 30 10 4 Fig. 2: ONF 16/25/25 L Operating fluid return line An oil return unit ORF (optional) can be used to return collected operating fluid from the ONF automatically to the pump automatically without interrupting the pump. 6

Installation 5 Installation 5.1 Assembly To install the ONF in a vacuum system, an ISO small flange or ISO clamp flanges are provided on the input side and output side. The flanges are provided with protective caps when delivered to protect the seals. If gases are pumped that may not enter the atmosphere, an exhaust line must be connected to the exhaust flange. If large amounts of vapour arise during operation, it is recommendable to install a condensate separator between the rotary vane pump and ONF so that condensate is removed in the KAS, and only oil mist enters the ONF. WARNING Poisonous substances exit from the exhaust! There is a poisoning hazard from discharged gases or vapours that can be hazardous and/or polluting during use. Install and run the exhaust line so that overpressure cannot build up inside it. Follow the vacuum pump installation instructions in the respective operating instructions. NOTE The filter inserts can become gummed! When pumping off gases and vapours that can polymerise, the filter inserts in the ONF can become gummed. Install a condensate separator upstream from the ONF. Remove the protective caps from the connection flanges. Place the ONF on the exhaust side of the rotary vane pump with the sightglass facing downward, and fasten it with the clamping ring (accessory) or bracket screws (accessory) if clamp flanges are used. 7

Installation 5.2 Installing the oil return line An oil return unit ORF (optional) can be used to return collected operating fluid from the ONF automatically to the pump automatically without interrupting the pump. ONF 16/25/25 L Unscrew operating fluid drain screw 33. Drain off operating fluid if so and fill in the pump. Screw in hose nipple 241 inplace of the operating fluid drain screw; take care with O-ring. Remove gas ballast valve 42 from the pump and absorb the operating fluid underneath. Re-fit the gas ballast valve with intermediate flange 46 and screw tight with longer screws; take care with O-ring 148. Screw fitting 240 into intermediate flange 46; take care with O-ring 138. Fit operating fluid return hose 242 at both sides on the hose nipples and tighten with hose clip 243 at the ONF side. Tighten the union nut of the fitting 240. ONF 33 (241/145) 243 242 42 240(138) 46(148) 196 Fig. 3: DUO Rotary vane pump with ONF and operating fluid return line 33 Operating fluid drain screw 42 Gas ballast valve 46 Intermediate flange 145 O-ring 240 Swiveling screw-fitting 241 Hose nipple 242 Operating fluid return line 243 Hose clip ONF 25 XL Unscrew operating fluid drain screw 33. Drain off operating fluid if so and fill in the pump. Screw in hose nipple 241 inplace of the operating fluid drain screw; take care with O-ring. Unscrew and remove the union nut of the screw fitting 77 and remove the sealing plug 78. Fit operating fluid return hose 242 at both sides on the hose nipples and tighten with hose clip 243 at the ONF side. Tighten the union nut of the screw fitting 77. 8

Operation 33 (241/145) 77 243 (78) 242 Fig. 4: PentaLine pump with ONF and Operating fluid return line 33 Operating fluid drain screw 77 Screw fitting 78 Sealing plug 145 O-ring 241 Hose nipple 242 Operating fluid return line 243 Hose clip 6 Operation NOTE Make sure that the return for the operating fluid works. Operating fluid is only sucked in and returned from an operating pressure of < 100 mbar and starting from a minimum quantity of operating fluid in the ONF. Top up with operating fluid in order to ensure the return of operating fluid at the start of the evacuation phase. Long evacuation phases with a high intake pressure should always be followed by operating phases with a lower operating pressure. NOTE Damage to the pump as a result of condensation in the operating fluid. Condensation caused by steam or by temperature differences between the ONF and the pump will impair the quality of the operating fluid after it is returned to the pump. The operating fluid should be drained in good time if it starts to accumulate condensation. 9

Maintenance 7 Maintenance 7.1 Draining the operating fluid If the accumulated operating fluid in the ONF is above the top edge of the sightglass 12, the operating fluid must be drained. The intervals at which the operating fluid is drained depends on the operating conditions. WARNING Operating fluid may contain toxic substances from the pumped media! Danger of poisoning from the emission of harmful substances from the operating fluid. Wear suitable protective clothing and respirators. Dispose of operating fluid according to the local regulations WARNING Toxic vapours! Danger of poisoning when igniting and heating synthetic operating fluids (e.g. F4/F5) above 300 C. Observe the application instructions of the operating fluid manufacturer. Do not allow operating fluid to make contact with tobacco products; observe safety precautions when handling chemicals. Screw out the operating fluid drain screw 33; pay attention to the O-ring 145. Drain the operating fluid. If the drained operating fluid is free of foreign material, it can be fed back to the rotary vane pump. 10

Maintenance 7.2 Changing and cleaning the filter insert The filter insert must be exchanged or cleaned when the exhaust pressure increases until the pressure relief valve opens inside the ONF and oil mist exits. Dismantling 4 30 11 2 22 20 16 6 28 8 28 33/143 18 14 8.1 12/13 32 Fig. 5: ONF 16/25/25 L (with ONF 25 XL 8.1 is a part of 8) 2 Casing 4 Cover 6 Casing of pressure relief valve 8 Filter insert 11 Deflector 12 Sight glass 14 Valve buffer 16 Pressure spring 18 Washer 20 Circlip 22 Compression spring 28 O-ring 30 O-ring 32 Screw 33 Operating fluid drain screw Switch off the pump, vent it to atmospheric pressure and let it cool down. Unscrew operating fluid drain screw 33. Drain operating fluid. If the drained operating fluid is free of contamination, it can be fed back to the rotary vane pump. Remove ONF from the system and pour out the remaining operating fluid. Unscrew and remove the screws 32 and carefully detach the housing 2 from the cover 4; Caution! The parts are under preload. Detach casing 2 and filter insert 8 and all other internally located parts from cover 4; take care with o-rings 30 and 28 (not with ONF 25 XL). Replace or clean the filter insert and re-assemble the parts in reverse order. Dismantling the pressure relief valve The pressure relief valve 8.1 at the ONF 25 XL is integrated in the filter insert 8 and cannot be dismantled. Loosen circlip 20 with pliers and dismantle washer 18, spring 16 and valve buffer 14 from valve housing 6. Clean all parts and inspect for wear. Check the sealed surface of valve buffer 14; replace if necessary. 11

Maintenance When assembling lightly oil valve buffer and ensure the correct seating in the valve housing. Cleaning WARNING Explosion hazard The use of volatile or combustible cleaning agents in vacuum systems can lead to explosive vapour-air mixtures. After cleaning ventilate and dry components adequately and let dry completely. Let the filter insert remain for approx. 12 h in solvent. Use air under slight pressure to eject the solvent from the filter inserts, and then dry them. Assembling Continue assembly by reversing the dismantling sequence, paying particular attention to compliance with the following steps. Put up cover 4, opening facing upwards. Lightly oil O-ring 28 (seal at ONF 25XL). When mounting casing 2 ensure the correct seating of the filter insert 8 and of the pressure relief valve casing; in particular take care with regard to the position of compression spring 22 and O-rings 28 and 30. 12

Service 8 Service Pfeiffer Vacuum offers first-class service! Fast replacement with exchange products in mint condition Advice on the most cost-efficient and quickest solution Detailed information, addresses and forms at: www.pfeiffer-vacuum.net (Service). Maintenance and repairs in the Pfeiffer Vacuum ServiceCenter The following steps are necessary to ensure a fast, smooth servicing process: Download the forms "Service Request" and "Declaration on Contamination". 1) Fill in the "Service Request" form and send it by fax or e-mail to your service address. Include the confirmation on the service request from Pfeiffer Vacuum with your shipment. Fill in the declaration on contamination and include it in the shipment (required!). Drain off operating fluid. If possible, send pump or unit in the original packaging. Sending of contaminated pumps or devices No units will be accepted if they are contaminated with micro-biological, explosive or radioactive substances. Hazardous substances are substances and compounds in accordance with the hazardous goods directive (current version). If pumps are contaminated or the declaration on contamination is missing, Pfeiffer Vacuum performs decontamination at the shipper's expense. Neutralise the pump by flushing it with nitrogen or dry air. Close all openings airtight. Seal the pump or unit in suitable protective film. Return the pump/unit only in a suitable and sturdy transport container and send it in while following applicable transport conditions. Service orders All service orders are carried out exclusively according to our repair conditions for vacuum units and components. 1) Forms under www.pfeiffer-vacuum.net 13

Accessories 9 Accessories Oil return unit ONF 16 ONF 25 ONF 25 L ONF 25 XL ORF from ONF 16 to UNO 2.5, DUO 2.5, UNO 5 ORF from ONF 16 to DUO 5 M ORF from ONF 25 to DUO 10 M ORF from ONF 25 L to DUO 20 M, TWIN 20-10 ORF from ONF 25 L to UNO 30 M ORF from ONF 25 to Penta 10 ORF from ONF 25 L to Penta 20 ORF from ONF 25 XL to Penta 35 PK 194 315 -T PK 196 172 -T PK 196 172 -T PK 198 545 -T PK 196 172 -T PK 196 944 -T PK 198 545 -T PK 198 545 -T 10 Technical data Parameter ONF 16 ONF 25 ONF 25 L ONF 25 XL Degree of separation 99.98 99.98 99.98 99.98 Flange (in) DN 16 ISO-KF DN 25 ISO-KF DN 25 ISO-KF DN 25 ISO-KF Flange (out) DN 16 ISO-KF DN 25 ISO-KF DN 25 ISO-KF DN 25 ISO-KF Capacity 0.15 l 0.15 l 0.25 l 0.35 l For pumping speed 2.5-5 m 3 /h 10 m 3 /h 30 m 3 /h 34 m 3 /h Weight 1.35 kg 1.4 kg 1.6 kg 1.9 kg 14

Technical data 10.1 Dimensions A E C F G D Fig. 6: ONF 16/25/25 L Dimensions ONF 16 ONF 25 ONF 25 L A 142 mm 147 mm 218 mm B 80 mm 80 mm 80 mm C 120 mm 132 mm 134 mm D 127 mm 127 mm 182 mm E 16 mm 16 mm 25 mm F 105 mm 105 mm 105 mm G 17 mm 23 mm 27 mm H 48 mm 48 mm - mm B H DN 25 ISO-KF 25 26 105 23 134 113 284 80 25 3 DN 25 ISO-KF Fig. 7: ONF 25 XL 15

Spare parts 11 Spare parts The spare parts packages listed here are only applicable for standard models. Please state all information on the rating plate when ordering spare parts. Other spare parts than those described in this manual must not be used without the agreement of Pfeiffer Vacuum. 11.1 Spare parts packages Spare parts package Maintenance kit Overhaul kit Model No. Consisting of ONF 16 PK E37 001 -T 8, 30 ONF 25 PK E37 001 -T 8, 30 ONF 25 L PK E37 003 -T 8, 30 ONF 25 XL PK E37 100 -T 8,30 ONF 16 PK E37 002 -T 8, 12, 13, 14, 16, 18, 20, 22, 30, 33 ONF 25 PK E37 002 -T 8, 12, 13, 14, 16, 18, 20, 22, 30, 33 ONF 25 L PK E37 004 -T 8, 12, 13, 14, 16, 18, 20, 22, 30, 33 ONF 25 XL PK E37 101 -T 8, 12, 22, 24, 30, 33 ONF 16/25/25 L 4 30 11 2 22 20 16 6 28 8 28 33/143 18 14 8.1 32 12/13 Fig. 8: ONF 16/25/25 L 16

Disposal ONF 025 XL 10 4 30 11 8 22 32 2 33 24 12 Fig. 9: ONF 025 XL 12 Disposal Products or parts thereof (mechanical and electrical components, operating fluids, etc.) may cause environmental burden. Safely dispose of the materials according to the locally applicable regulations. 17

Vacuum is nothing, but everything to us! Turbopumps Rotary vane pumps Roots pumps Dry compressing pumps Leak detectors Valves Components and feedthroughs Vacuum measurement Gas analysis System engineering Service Pfeiffer Vacuum Technology AG Headquarters/Germany Tel. +49-(0) 64 41-8 02-0 Fax +49-(0) 64 41-8 02-2 02 info@pfeiffer-vacuum.de www.pfeiffer-vacuum.net