F261 Series Fluid Flow Switches

Similar documents
P266 Series Single-Phase Condenser Fan Speed Control

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC2100 Series Networked Thermostats

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

TEC210x-2 Series Networked Thermostats

MR3CCUHV Temperature/Defrost Control

TEC1100 Series Thermostats

NS Series Network Sensors

safety & regulatory information

Surface-Mounted NS Series Network Sensors without LCD

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

CD-Px Series Duct Mount CO 2 Transmitters

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Installation Instructions

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD

SEE DISCLAIMER ON REVERSE

NS Series Network Sensors

T500 Series Non-Programmable Thermostats

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

! WARNING. Before using product, read and understand instructions.

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Location Requirements

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage

! WARNING. Before using product, read and understand instructions.

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

! WARNING. Before using product, read and understand instructions.

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Facility Explorer One-to-One Wireless Room Sensing System

3M Benchtop Air Ionizer 963E. User s Guide

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Optima ZigBee Thermostat

Series A28 Two stage Thermostats. Feature and Benefits

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

ShockLink. Important Product Information.

Pet Immune SAW PIR Motion Sensor

Flow Switches. Liquid Flow Switches. Mounting Methods

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

Comfort Air Fan with Remote Installation and Operation Manual

ACT2-CS Convenience Store Controller

Wireless High Bay Sensor (WHS100) Installation Instructions

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Fume Hood Operating Display Panel

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Centro-Matic Automated Lubrication Systems System Controls

40 Built-in Electric Fireplace Operating and Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Installation & Operation Manual

A-4400 Series Refrigerated Air Dryers for Pneumatic Control Systems

Installation & Operation Manual

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Smart Hub THERMOSTAT. Installation Manual

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Projection Alarm Clock

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Wireless Home Appliance Timer Remote Control Kit

Wireless Outdoor Air Reset Adaptor PN:

POWERED ANODE SYSTEM

TC-5231 Series, TC-5232, & TC-5241 Series

270XT Freeze Protection, IP30

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

U5600. Wireless Pressure Transducer SPECIFICATIONS

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

A99B Series Temperature Sensors

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Installation & Operation Manual

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Performance Thermal Binder

Installation & Operation Manual

180 Degree Ceiling Mounted Occupancy Sensors

TM-3100 Series Room Temperature Sensor

Flush Mount SIP Access Control Intercom with Relay Installer s Guide

Panel XTO210/610/710 GPRS

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

Installation & Operation Manual

Panel XT210/610/ Description. Supervised Wireless Technology

Wi-Fi DOOR/WINDOW SENSOR

W43A Humidistat. Features and Benefits

Transcription:

F261 Series Fluid Flow Switches Product Bulletin Code No. LIT-12011987 Issued July 22, 2015 Refer to the QuickLIT website for the most up-to-date version of this document. The F261 Series Flow Switches respond to fluid flow in lines carrying water, ethylene glycol, or other nonhazardous fluids. These models also work in applications with swimming pool water and lubricating oils. F261 Series Standard Flow Switches use a variety of paddle sizes to respond to fluid flow rates in applications with 1 inch trade size (or greater) pipe. F261 Series Low Flow Switches respond to low fluid flow rates in applications with 1 inch trade size (or less) pipe. A low-energy model with gold-plated contacts provides improved electrical performance in low-voltage, low-current circuits (dry circuits) to switch low-energy resistive loads, such as control signals. Figure 1: F261KAH Flow Switch Table 1: Features and Benefits Features Type 3R (NEMA) or Type 4 (NEMA) Polycarbonate Enclosure Viton Diaphragm Low-Flow Operation on Low-Flow Models Gold-Plated Contacts on Selected Models Maximum Fluid Pressure of 290 psig (20 bar) Benefits Provides dust protection in indoor and outdoor applications. Allows use in fluid lines carrying chlorinated water, treated water, or other nonhazardous fluids. Actuates switch with less than 2.0 GPM (7.6 L/min) flow for water applications or 11.0 GPM (41.6 L/min) flow for steam applications. Reduce intermittent contact problems in low-voltage and low-current circuits (dry circuits). Permits use in a wide range of pressure flow conditions. 1

Application IMPORTANT: All F261 Series Flow Switches are intended to control equipment under normal operating conditions. Where failure or malfunction of an F261 Flow Switch could lead to an abnormal operating condition that could cause personal injury or damage to the equipment or other property, other devices (limit or safety controls) or systems (alarm or supervisory) intended to warn of, or protect against, failure or malfunction of the F261 Flow Switch must be incorporated into and maintained as part of the control system. IMPORTANT: Do not install or use this F261 Series Flow Switch in or near environments where corrosive substances or vapors could be present. Exposure of the F261 Series Flow Switch to corrosive environments may damage the device s internal components and will void the warranty. IMPORTANT: Do not use F261 Series Flow Switches where the fluid in the pipes drops below the fluid s freezing point, causing an internal freeze-up. Standard Flow Switches Use F261 Series Standard Flow Switches in applications with fluid pressures up to 290 psig (20 bar). A typical application for a standard F261 flow switch is to shut down the refrigeration compressor on a fluid chiller system if flow stops, reducing chances of chiller freeze-ups. Low-Flow Switches The F261 Series Low-Flow Switches have 1/2 in. Female NPTF or 3/4 in. Female NPTF inlet and outlet connections. Use F261 Low-Flow Switches in applications where flow rates are low, such as: water purification and treatment systems booster pumps cooling systems for electronic tubes, bearings, and compressors rapid recovery water heaters (starting the water heater when water is withdrawn) control of food waste disposal units (starting the motor when a predetermined amount of water is flowing through the unit and stopping when the flow decreases to a predetermined rate) switch to shut down the refrigeration compressor on a fluid chiller system if flow stops, reducing chances of chiller freeze-ups Low-Energy Flow Switches with Gold-Plated Contacts Models with gold-plated contacts provide improved electrical performance in low-voltage, low-current circuits (dry circuits). Use these models to switch low-energy resistive loads, such as control signals. Type 3R (NEMA) / IP43 Enclosures Use models with Type 3R (NEMA) / IP43 enclosures for indoor or outdoor applications where they are protected from weather and splashing water. Use these models with pipes carrying fluids at temperatures in the range of -20 F to 250 F (-29 C to 121 C). A drain hole allows Type 3R (NEMA) models to be used in applications where the fluid temperature is below the ambient dew point temperature. The drain hole knockout is plugged on IP43 models to prevent the intrusion of objects 1 mm Ø and greater. Removing the plug reduces the enclosure rating to IP23, allowing these models to be used in applications where the fluid temperature is below the ambient dew point temperature. Do not use these models in applications or environments where the temperature may cause the fluid to freeze. Type 4 (NEMA) / IP67 Enclosures Use models with Type 4 (NEMA) enclosures for indoor or outdoor applications in high humidity environments. Use these models with pipes carrying fluids at temperatures in the range of -20 F to 250 F (-29 C to 121 C). A sealing O-ring between the cover and case allows these models to be used in high-humidity environments, or applications where the fluid temperature is below the ambient dew point temperature. Do not use these models in applications or environments where the temperature may cause the fluid to freeze. Media Compatibility F261 Series Flow Switches are compatible with several common media: water ethylene glycol brine sea water swimming pool water lubricating oils 2

Dimensions 4 [102] 2 [51] 2-3/4 [70] 11/16 [18] 2-9/16 [65] 1/2 [12] Typical Thread Engagement 30 mm Hex 1-11 1/2 NPT 4-1/2 [114] 3-1/2 [89] 1/2 in. trade size or PG-16 conduit opening 2-1/8 [54] 5-11/16 [144] 8-3/4 [222] Figure 2: Dimensions for F261 Standard Flow Switch, in. [mm] FIG:F261_stndrd_dmnsns 4 [102] 2 [51] 2-3/4 [70] 11/16 [18] 2-9/16 [65] 1/2 in. - 14 NPTF or 3/4 in. - 14 NPTF, as specified (both ends) PG-16 conduit opening 1-1/2 [39] 2-5/16 [59] 1-1/8 [29] 3/4 [19] 1-1/2 [38] FIG:F261_lwflw_dmnsns Figure 3: Dimensions for F261 Low-Flow Switch, in. [mm] 3

Operation The flow switch responds to pressure exerted on the fluid paddle by the flowing fluid. A range adjustment screw adjusts the rate of the flow required to activate the switch. See Table 3 through Table 8 for flow rates. The red terminal is the Common. Red to Yellow closes on flow increase. Red to Blue closes on flow decrease. Increase in Flow Above Setpoint Table 2: F261 Switch Action Flow Action Switch Closure Blue Increase Red to Yellow Decrease Red to Blue Figure 4: F261 Control Switch Action Red Yellow Decrease in Flow Above Setpoint Table 3: Flow Rates for Standard Models, 1-3 in. Paddles GPM (m 3 /hr) Required to Activate Switch for Pipe Size (in.) 1 1-1/4 1 1-1/2 1 2 2-1/2 2 3 4 3 5 3 6 3 8 3 Minimum Flow Increase (Close R to Y) 4.20 (0.95) 5.80 (1.32) 7.50 (1.70) 13.7 (3.11) 18.0 (4.09) 27.5 (6.24) 65.0 (14.8) 125 (28.4) 190 (43.2) 375 (85.2) Flow Decrease (Close R to B) 2.50 (0.57) 3.70 (0.84) 5.00 (1.14) 9.50 (2.16) 12.5 (2.84) 19.0 (4.32) 50.0 (11.4) 101 (22.9) 158 (35.9) 320 (72.7) Maximum Flow Increase (Close R to Y) 8.80 (2.0) 13.3 (3.02) 19.2 (4.36) 29.0 (6.59) 34.5 (7.84) 53.0 (12.0) 128 (29.1) 245 (55.6) 375 (85.2) 760 (173) Flow Decrease (Close R to B) 8.50 (1.93) 12.5 (2.84) 18.0 (4.09) 27.0 (6.13) 32.0 (7.27) 50.0 (11.4) 122 (27.7) 235 (53.4) 360 (81.8) 730 (166) 1. Values for 2 in. paddle trimmed to pipe. 2. Values for a 3 in. paddle trimmed to fit pipe. 3. Values calculated for a factory-installed set of 1, 2, and 3 in. paddles. Table 4: Flow Rates for Standard Models, 6 in. Paddles Minimum Maximum Flow Increase (Close R to Y) Flow Decrease (Close R to B) Flow Increase (Close R to Y) Flow Decrease (Close R to B) GPM (m 3 /hr) Required to Activate Switch for Pipe Size (in.) 4 5 6 8 37.0 (8.40) 57.0 (12.9) 74.0 (16.8) 205 (46.6) 27.0 (6.13) 41.0 (9.31) 54.0 (12.3) 170 (38.6) 81.0 (18.4) 118 (26.8) 144 (32.7) 415 (94.3) 76.0 (1.93) 111 (25.2) 135 (30.7) 400 (90.8) 4

Flow Rate (L/Min) 0 7.6 15.1 22.7 30.3 37.9 45.4 53.0 60.6 68.1 75.7 83.3 90.9 98.4 106 113.6 20 137.9 18 124.1 16 110.3 Pressure Drop (PSI) 14 12 10 8 1/2 in. pipe size 3/4 in. pipe size 96.5 82.7 69.0 55.2 Pressure Drop (kpa) 6 41.4 4 27.6 2 13.8 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 0 FIG:F261_LwFlw Flow Rate (GPM) Figure 5: Pressure Drop versus Flow Rate, F261 Series Low-Flow Switches (F261KEH-V01C, F261MEH-V01C, F261KFH-V01C, F261MFH-V01C) Table 5: GPM (L/Min) Required to Actuate F261 Series Low Flow Switches Pipe Size Minimum Maximum 1/2 x 1/2 in. Female NPTF 1 3/4 x 3/4 in. Female NPTF 2 3/4 x 3/4 in. Female NPTF 3 Flow Increase (R to Y Closes) 1.30 (4.92) 2.00 (7.57) 10.90 (41.26) Flow Decrease (R to B Closes) 0.60 (2.27) 0.60 (2.27) 7.20 (27.25) Flow Increase (R to Y Closes) 2.60 (9.84) 3.60 (13.63) 17.00 (64.35) Flow Decrease (R to B Closes) 1.25 (4.73) 1.30 (4.92) 14.20 (53.75) 1. F261KEH-V01C, F261MEH-V01C 2. F261KFH-V01C, F261MFH-V01C 3. F261KFH-V02C (designed for steam applications) 5

Ordering Information F61 to F261 Cross-Reference Tables Table 6: Standard Flow Models Cross Reference F61 Series Model F261 Series Model F61KB-11C F261KAH-V01C F61LB-1C F261MAH-V01C F61MB-1C F261MAH-V01C F61MB-5C F261MAH-V01C Table 7: Low-Flow Models Cross Reference F61 Series Model F261 Series Model F61KD-3C F261KEH-V01C F61KD-4C F261KFH-V01C F61KD-8C F261KFH-V02C F61MD-1C F261MEH-V01C F61MD-2C F261MFH-V01C Selection Tables Table 8: F261 Series Standard Model Flow Switches Product Code Description Number F261KAH-V01C F261MAH-V01C F261MAL-V01C 1 Repair Information Standard model flow switch with Type 3R (NEMA) enclosure; 1 in., 2 in., 3 in., and 6 in. stainless steel paddles, lock-tooth washer, and stainless steel paddle screw supplied uninstalled Standard model flow switch with Type 4 (NEMA) enclosure; 1 in., 2 in., 3 in., and 6 in. stainless steel paddles, lock-tooth washer, and stainless steel paddle screw supplied uninstalled Standard model flow switch with Type 4 (NEMA) enclosure;1 in., 2 in., 3 in., and 6 in. stainless steel paddles, lock-tooth washer, and stainless steel paddle screw supplied uninstalled 1. This model is a low-energy flow switch with gold-plated electrical contacts. Table 9: F261 Series Low-Flow Model Flow Switches Product Code Description Number F261KEH-V01C F261KFH-V01C F261KFH-V02C F261MEHV01C F261MFH-V01C Low-flow model flow switch with Type 3R (NEMA) enclosure 1/2 in. x 1/2 in. Female NPTF inlet and outlet Low-flow model flow switch with Type 3R (NEMA) enclosure; 3/4 in. x 3/4 in. Female NPTF inlet and outlet Low-flow model flow switch with Type 3R (NEMA) enclosure; 3/4 in. x 3/4 in. Female NPTF inlet and outlet Low-flow model flow switch with Type 4 (NEMA) enclosure; 1/2 in. x 1/2 in. Female NPTF inlet and outlet Low-flow model flow switch with Type 4 (NEMA) enclosure; 3/4 in. x 3/4 in. Female NPTF inlet and outlet Table 10: Replacement Paddle Parts Product Code Description Number KIT21A-600 KIT21A-601 KIT21A-602 Stainless steel 3-piece paddle (3 in., 2 in., and 1 in. segments) Stainless steel 6 in. paddle Stainless steel 3-piece paddle (3 in., 2 in., and 1 in. segments) and Stainless steel 6 in. paddle Do not make field repairs, except for replacement of the flow paddle. For a replacement control or paddle kit, contact the nearest Johnson Controls/PENN distributor. For more information, contact Johnson Controls/PENN application engineering at 1-800-275-5676 or 1-414-524-5535. 6

Technical Specifications Table 11: F261xxH Series Standard Controls Electrical Ratings UL60730/UL1059 EN60730 Volts 50/60 Hz 24 VAC 120 VAC 208 VAC 240 VAC 24 VAC 230VAC Horsepower 1 1 1 Full Load Amperes 16 10 10 8 Locked Rotor Amperes 96 60 60 48 Resistive Amperes 16 16 10 10 16 16 Pilot Duty VA 125 720 720 720 77 720 Table 12: F261xxL Series Low Energy Controls Electrical Ratings, AC Current UL60730/UL1059/EN60730 Volts AC, 50/60 Hz 4 VAC 24 VAC 120 VAC Resistive Amperes 1 10 10 10 Pilot Duty VA 2 12 72 360 1. Maximum Dry Circuit Rating: Resistive only, 400 mw at 28 VAC/VDC. Once a relay has been used at the General Rating level, the Dry Circuit Rating is no longer valid. 2. Meets UL 100,000 cycle UL endurance test requirement at switch with T min greater than or equal to 32 F (0 C). Table 13: F261xxL Series Low Energy Controls Electrical Ratings, DC Current UL60730/UL1059/EN60730 Volts DC 4 VDC 24 VDC 48 VDC Resistive Amperes 1 1 1 1 1. Maximum Dry Circuit Rating: Resistive only, 400 mw at 28 VAC/VDC. Once a relay has been used at the General Rating level, the Dry Circuit Rating is no longer valid. Table 14: UL Conformity Declaration Information (Part 1 of 2) Information Description Purpose of Control F261 Fluid Flow Switch Construction of Control Electronic independently mounted control Number of Cycles 100,000 cycles Method of Mounting Mounting to sensed media vessel/orientation Control Type 1 or Type 2 Action Type 1.C (Microinterruption) External Pollution Situation Pollution degree 4 Internal Pollution Situation Pollution degree 2 Rated Impulse Voltage 4,000 VAC Ball Pressure Temperature Enclosure: 266 F (130 C ) Switch Component: 252 F (122 C) Control - Instruction 7

Table 14: UL Conformity Declaration Information (Part 2 of 2) Field Wiring Rating Wire/Cord Temperature Ratings: 140 F (60 C) only permitted when ambient air and media are less than 113 F (45 C) 167 F (75 C) only permitted when ambient air and media are less than 140 F (60 C) 194 F (90 C) only permitted when ambient air is less than 140 F (60 C) and media is less than 167 F (75 C) 302 F (150 C) permitted when ambient air is less than 140 F (60 C) and media is less than 249 F (121 C) Vessel Pressure F261 Fluid Flow Switch: 290 psi (20 Bar) F261 Series Fluid Flow Switches Switch SPDT Enclosure UL: Type 3R or Type 4 CE: IP43 (IP23 with drain hole plug removed) or IP67 Wiring Connections Three color-coded screw terminals and one ground terminal Conduit Connection One 7/8 in. (22 mm) hole for 1/2 in. trade size (or PG16) conduit Pipe Connector Standard: 1 in. 11-1/2 NPT Threads Low-Flow: 1/2 in. x 1/2 in. Female NPTF; 3/4 in. x 3/4 in. Female NPTF Maximum Fluid Pressure 290 psi (20 bar) Minimum Fluid Temperature 1-20 F (-29 C) Maximum Fluid 250 F (121 C) Temperature 2 Ambient Conditions -40 to 140 F (-40 to 60 C) Compliance North America: culus Listed; UL 60730, File E6688; FCC Compliant to CFR47, Part 15, Subpart B, Class B Industry Canada (IC) Compliant to Canadian ICES-003, Class B limits Europe: CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive and the Low Voltage Directive. Australia/New Zealand Mark: RCM Compliant 1. Ensure that the low liquid temperature combined with the low ambient temperature does not lead to the freezing the liquid inside the body (or bellows, where appropriate). Please observe the liquid freezing point. 2. At higher ambient temperatures, the maximum allowed liquid temperature becomes lower. The temperature of the electrical switch inside should not exceed 158 F (70 C). The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult Johnson Controls/PENN Refrigeration Application Engineering at 1-800-275-5676. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 8

United States Emissions Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help. Canadian Emissions Compliance This Class (B) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe (B) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls and PENN are registered trademarks of Johnson Controls, Inc. in the United States of America and/or other countries. All other trademarks used herein are the property of their respective owners. Copyright 2015 by Johnson Controls, Inc. All rights reserved. Published in U.S.A. 9 www.johnsoncontrols.com