BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

Similar documents
B.D.I. The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc

B.D.I. The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc

WELL ACTIVATION TYPE A & TYPE I AND SAFETY PROTECTION RUPTURE DISCS FEATURES BENEFITS

Rupture Discs with B.D.I. Alarm System

OIL & GAS EXPERTS PRESSURE RELIEF & PRESSURE ACTIVATION WE ARE THE RIGHT SOLUTION

INSTRUCTION & SERVICE MANUAL

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Inductive slot sensor

Model 144H. Product Data Sheet , Rev DB February Content

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

FLAME SAFETY DEVICES THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT ARRESTERS DEFLAGRATION // ATEX CERTIFIED

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Technical Data. General specifications. Rated operating distance s n 5 mm

Ar-Mite TM Low Flow Armored Flowmeter

UL HAZARDOUS LOCATIONS SERVICES

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

4) Intrinsic Safety Certification

Certification Supplement Manual

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

standards: standards:

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Performance Data. curus Component Recognized; File No. E IP 20

IECEx Certificate of Conformity

Technical Data. Dimensions

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Dependable Solutions for Gas Detection

Model 144H. Product Data Sheet , Rev DB February Content

High Pressure Conductivity Monitor

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Worcester Controls PS/PM Series UltraSwitch. Switchbox

Fixed Gas Detection System/Meridian CERTIFICATION

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Dräger Polytron 7000 Fixed gas detector

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Safety instructions VEGAPULS 64

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Guide for hazardous areas

Rosemount 3490 Series

SET Installation and Operating Instructions. Level switch for one sensor

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Rosemount 2090P Pulp and Paper Pressure Transmitter

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Dräger Polytron 8000 Stationary gas detector (EC)

your dust explosion protection experts

Level gauges Series LS Level indicator, switch and transmitter for liquids

Instrumentation Products and Applications

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Sitron s CF Line of Flow Switch Monitors

Technical Data. Dimensions

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Intrinsically Safe Solutions

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Quick Start Manual July pointek CLS100

Dräger Polytron 5700 IR Detection of flammable gases and vapours

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

DB5 Intrinsically Safe Sounder Type DB-5

RF Admittance Technology FACTS

Certification Supplement Manual

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Technical Data. Dimensions

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Engineering Guideline. pac- Carriers Type Universal

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Glass Tube Variable Area Flowmeter

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

INSTRUCTION MANUAL (ATEX / IECEx)

Brooks MT3750 Low Flow Armored Flowmeter

Dräger Polytron 8200 Stationary gas detector (CatEx)

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Dräger Polytron 8310 Stationary gas detector (DSIR)

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Introduction to Flow Switch

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

SET-2000 Hi Level/Oil

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Flexible Heaters W A T L O W. Temperature Sensors and Controllers SERIES EHG

Transcription:

B URST DI S C S E N SOR SY STE M AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS The Burst Disc Sensor System utilizes an electronic instrument which provides instantaneous notification of the bursting of a rupture disc using versatile interface cable options. When combined with an alarm monitor, this system provides protection for lives, equipment and the environment. Designed for use with ASME and DIN flanges 1-12 (25mm-300mm) or sanitary applications 1-4 (25mm-100mm), the Burst Disc Sensor System utilizes a sensor strip with a flexible potentiometer (electrical component that varies resistance in response to deflection) to signal a rupture disc has burst. BENEFITS The Burst Disc Sensor System provides many benefits, which include: Allows direct interface to PLC s, DCS (Distributed Control Systems), alarm monitors or isolating barriers and can provide dry contacts for industrial controls Figure 5 Improved durability: The conductive element is fully encapsulated in corrosive resistant DuPont KAPTON polyimide film The advanced technologies of the sensor strip minimize the risk of damage due to excessive stress beyond recommended bolting load The alignment ring provides a rigid support for the sensor cable, minimizing cable strain Modernized output cable connectors in accordance with IEC 61076-2101. IP67 rated M12 connector. The sensor is installed at the downstream side of a rupture disc, bolted between the rupture disc holder and flange or sanitary ferrule as shown: FIGURE 1 OUTLET COMPANION FLANGE SENSOR LABEL SENSOR RUPTURE DISC & HOLDER ASSEMBLY INTEGRAL INSTALLATION INLET GASKET INLET COMPANION FLANGE FLOW BURST DISC SENSOR SYSTEM INSTALLATION OF THE BURST DISC SENSOR SYSTEM PERFO RMANC E U ND ER PRESS U RE

DATASHEET // PAGE 2 MAIN COMPONENTS OF THE SENSOR SYSTEM The Burst Disc Sensor System is comprised of two main assemblies: the Sensor and Interface Cable as shown below: FIGURE 2 Sensor TEFLON MEMBRANE METAL RING SENSOR CABLE SENSOR STRIP GASKET (on each side) SENSING ELEMENT INTEGRAL Sensor TEFLON MEMBRANE GASKET SENSOR CABLE Interface Cable PRE-AMP CABLE OUTPUT CABLE M12 CONNECTOR INTERFACE MODULE SENSOR STRIP SENSING ELEMENT SANITARY Sensor TEFLON MEMBRANE GASKET CDC Alarm Monitor SENSOR CABLE SENSING ELEMENT SENSOR STRIP BURST DISC SENSOR SYSTEM INFORMATION AVAILABLE ON PAGES 6 & 7 SENSOR FEATURES INDUSTRIAL APPLICATIONS SANITARY APPLICATIONS INTEGRAL SANITARY One-time use Sensor Assembly Configurable for all Model Interface Cable Assemblies Temperature: -40 F to 400 F (-40 C to 204 C) 1 Available for Industrial and Sanitary applications Figures 3, 4 Integral for SANITRX HPX, SANITRX HPX II & SANITRX LPX (2-3 only) Rupture Discs Standard 1.5 ft (0.45 m) long, shielded blue cable with M12 connector. The M12 connector ensures a secure connection to the interface cable. The connector can be easily disconnected and reconnected by the user for replacement of the disposable sensor. The M12 meets an IP67 rating. SENSOR NOMINAL SIZES & ACTIVATION PRESSURES FIGURE 3 FIGURE 4 NOMINAL SIZE MINIMUM PRESSURE 2 in mm psig barg 1 25 5 0,35 1 ½ 40 4 0,28 2 50 3 0,21 3 80 2 0,14 4 100 2 0,14 6 150 2 0,14 8 200 2 0,14 10 250 2 0,14 12 300 2 0,14 SANITARY/INTEGRAL NOMINAL SIZE MINIMUM PRESSURE 2 in mm psig barg 1 25 25 1,72 1 ½ 40 10 0,69 2 50 5 0,34 3 80 2 0,14 4 100 1 0,07 1 Temperature limits may vary based on gasket material 2 Minimum pressure is based on PSIG values. BARG values are provided for reference.

DATASHEET // PAGE 3 INTERFACE CABLE FEATURES Reusable assembly Routes electric power to the sensor Figures 2, 5 Monitors sensor strip resistance for rupture disc status Transmits output signal to user s system Figure 5 Temperature limits: -40 F to 158 F (-40 C to 70 C) 6 ft long (1.8 m) shielded pre-amp cable with M12 connector and 6 ft long (1.8 m) shielded output cable with bare lead ends (12 ft or 3.6 m total length) INTERFACE CABLE MODEL OPTIONS Interface Cable // Model 2W-IS 2W-IS MODEL Two-wire intrinsically safe design for use with a customer s safety barrier or the CDC MTB-700 Monitor Certified for ATEX (EU) & IECEx (International) for Zone 0 Group IIC and Zone 20, Group IIIC Certified for UL and c UL for Class I, Div 1 Group A, B, C, D; Class II, Div 1 Group F, G and Class III, Div 1 Interface Cable // Model 2W-NIS 2W-NIS MODEL Two-wire non-intrinsically safe design for use with PLC and DCS discrete input switching Powered from PLC or DCS or other suitable load that is in-series connected to DC power, no separate power input wiring is required Listed by UL and cul under Process Control Equipment Category Interface Cable // Model 4W-NIS 4W-NIS MODEL Four-wire non-intrinsically safe design with dry contact switching for non-classified (non-hazardous) locations Provides a single-pole single-throw (SPST) normally closed relay output signal Power-isolated switch output and switching capacity for DC and AC voltage Output available for PLC, DCS, interposing relays, alarm systems and actuator elements Listed by UL and cul under Process Control Equipment Category Best suited for non-hazardous applications that require full isolation for additional safety and where users are not limited to using two-wire connection

DATASHEET // PAGE 4 INTERFACE CABLE SPECIFICATIONS & CERTIFICATIONS FIGURE 5 INTERFACE CABLE SPECIFICATIONS & CERTIFICATIONS MODEL 2W-IS 2W-NIS 4W-NIS OPERATION Normally Closed Normally Closed Normally Closed INTRINSICALLY SAFE ATEX II 1 GD Ex ia IIC T4 Ga Ex ia IIIC T135ºC Da No No LOAD TYPE Safety Barrier Switching Amplifier PLC/DCS discrete input Resistive or Inductive load, e.g., PLC/DCS, relay, etc OPERATING VOLTAGE 6 ~ 12 VDC 7 ~ 30 VDC 6 ~ 28 VDC OUTPUT SIGNAL TYPE 2-Wire electronic switch (power input and signal output share the same 2-wire cable) 2-Wire electronic switch (power input and signal output share the same 2-wire cable) Reed relay switching dry contact OUTPUT LEVEL SWITCHING ON 4.5 ma typical 2.5 ma MIN 4.85 ma MAX 12 ma typical 10.5 ma MIN 12.5 ma MAX Max switching power: 3VA Max carry current: 250 ma Max switching voltage: 60 VDC or 30 VAC OUTPUT LEVEL SWITCHING OFF 0.85 ma MAX 0.85 ma MAX Open Contact CE MARK Yes (under the ATEX Directive) Not Required Not Required UL / cul MARK* Yes Class I Div 1 A,B,C,D Groups Class II Div 1 F,G Groups Class III Div 1 Yes UL File# E350819 Yes UL File # E350819 IECEx Ex ia IIC T4 Ga Ex ia IIIC T135 C Da No No ALARM MONITOR OPTIONS MTB-700 Yes No Yes** BB-100A No No Yes** BB-400A No No Yes** * UL and cul marks indicate compliance with USA and Canadian product safety standards ** The 4W-NIS model can work with any of our monitor models if separate input power is provided. However, the 4W-NIS is NOT for intrinsically safe applications and is not recommended for use in hazardous locations.

DATASHEET // PAGE 5 BOLTING CLASSES & GASKET MATERIALS/TEMPERATURES Bolting classes for the Sensor and gasket materials & temperatures for the Sanitary Sensor are as follows: BOLTING CLASSES // INDUSTRIAL APPLICATIONS SIZE BOLTING CLASS in mm ASME DIN 1 25 150#, 300#/600# PN 10/40 1½ 40 150#, 300#/600# PN 10/40 2 50 150#, 300#/600# PN 10/40 3 80 150#, 300#/600# PN 10/40 4 100 150#, 300# PN 10/16 6 150 150#, 300# PN 10/16 8 200 150#, 300# PN 16 10 250 150#, 300# PN 16 12 300 150#, 300# PN 16 FIGURE 6 ADDITIONAL BOLTING CLASSES ARE AVAILABLE UPON REQUEST GASKETS // INDUSTRIAL APPLICATIONS THE Sensor is available with non-asbestos or fiber reinforced fluoropolymer gaskets. GASKET MATERIALS & TEMPS // SANITARY APPLICATIONS FDA AND USP CLASS VI COMPLIANT GASKET MATERIALS SERVICE TEMPERATURES MINIMUM FIGURE 7 MAXIMUM F C F C Peroxide Cured Silicone -80-62 450 232 Platinum Cured Silicone -80-62 350 177 White VITON -20-29 400 204 Black VITON -20-29 400 204 White EPDM -55-48 275 135 Black EPDM -55-48 275 135 PTFE Fluoropolymer -40-40 450 232 Gaskets designed for use in ferrule connections having ASME-BPE dimensions or equivalent. Gaskets for use on Sanitary installations not integral to the rupture disc.

DATASHEET // PAGE 6 CONTINENTAL DISC ALARM MONITORS SENSOR SYSTEM, INCLUDING ALARM MONITOR A continuous signal flows between the Burst Disc Sensor System and the Alarm Monitor under normal conditions. Once the rupture disc bursts, the Sensor System indicates the event, opening the electrical circuit. NOTE: If the Burst Disc Sensor System loses power, it defaults to an open circuit. Continental Disc Alarm Monitors contain replaceable modules with individual channel relays. Each channel relay connects to one Sensor System. As the rupture disc bursts and the Sensor System indicates the event, a specific relay is actuated, sending a signal to the control panel. Control panels, annunciators, light panels or other signalling devices can be used to warn of a ruptured disc. The Sensor System has the versatility to adapt to a variety of warning devices. The individual relay circuitry will allow the user to monitor several Sensor Systems simultaneously. Pumps, valves and other systems may also be activated to respond to an overpressure situation by the indication of a specific Burst Disc Sensor System.

DATASHEET // PAGE 7 CONTINENTAL DISC ALARM MONITOR OPTIONS AVAILABLE ALARM MODELS DISCREET CHANNELS AVAILABLE FIGURE 8 MTB-700 BB-100A BB-400A 2 or 4 2 8 AUDIO / VISUAL ALARMS PROVIDED DRY CONTACTS FOR REMOTE ALARMS OUTPUT RELAY TYPE RELAY MAX CURRENT INTRINSICALLY SAFE* FIELD CIRCUIT BARRIER TYPE Optional NO NO YES YES YES DPDT Form C SPDT Form C SPDT Form C 5 A @ 240 VAC Resistive 5 A @ 24 VDC Resistive 1/8 HP @ 120/240 VAC, 7 A maximum carry current 2 A @ 120 VAC Resistive 1 A @ 120 VAC Inductive 2 A @ 24 VDC Inductive 2 A @ 120 VAC Resistive 1 A @ 120 VAC Inductive 2 A @ 24 VDC Inductive YES NO* NO* galvanically isolated zener diode zener diode ENCLOSURE RATING NEMA 4, 4X, 12, 13 NONE NONE OPERATING TEMPERATURE RANGE -4 F to +113ºF (-20ºC to +45ºC) -40ºF to +104ºF (-40ºC to +40ºC) -40ºF to +104ºF (-40ºC to +40ºC) RESET MODE (LATCHING, NON-LATCHING) OUTPUT CURRENT latching only either available either available 7 VDC @ 22 MA 6 VDC @ 0.1 MA 6 VDC @ 0.1 MA INPUT POWER OPTIONS 120/240 VAC, 50/60 Hz 24 VDC +/- 2 V 115/230 VAC 50/60 Hz 12 VDC +/- 1 V 115/230 VAC 50/60 Hz 12 VDC +/- 1 V REMOTE MASTER TEST CONTACTS YES NO NO REMOTE MASTER RESET CONTACTS YES YES YES BARRIER CERTIFICATIONS ALARM MONITOR OPTIONS FM, ATEX, CSA, IECEx None None 2W-IS 4W NIS** 4W NIS** * Intrinsically Safe is defined as: Apparatus, including wiring, in which any spark or thermal effect produced either normally or in specified fault conditions... is incapable under test conditions of causing ignition of a specified mixture of flammable or combustible material in air. ** The 4W-NIS model can work with any of our monitor models if separate input power is provided. However, the 4W-NIS is NOT for intrinsically safe applications and can NOT be used in hazardous locations.

CERTIFICATIONS Available When Specified Pressure Equipment Directive C LISTED US DATASHEET // PAGE 8 Rupture Disc Selection RUPTURE DISC SELECTION All Burst Disc Sensor System models can be used with the following rupture disc types, installed in insert type holders for 1 through 12 sizes: ATEX Directive Compliant HPX HPX-Ta LOTRX MICRO X COMPOSITE STANDARD All Sanitary and Integral Burst Disc Sensor System models can be used with the following rupture disc types: SANITRX HPX SANITRX HPX II SANITRX LPX (2-3 only) FOR MORE INFORMATION ON OUR OTHER BURST DISC INDICATION PRODUCTS, PLEASE SEE THE B.D.I. BURST DISC INDICATOR DATASHEET. Kapton is a registered trademark of E.I. du Pont de Nemours and Company // GYLON is a registered trademark of Garlock Family of Companies HEADQUARTERS // 3160 W. Heartland Drive Liberty, MO 64068 USA Ph (816) 792 1500 Fax (816) 792 2277 sales@contdisc.com contdisc.com THE NETHERLANDS Energieweg 20 2382 NJ Zoeterwoude-Rijndijk The Netherlands Ph +(31) 71 5412221 Fax +(31) 71 5414361 cdcnl@contdisc.com CHINA Room 1312, Tower B, COFCO Plaza No. 8 JianGuoMenNei Avenue Beijing (10005), P.R. China Ph +(86) 10 522 4885 Fax +(86) 10 6522 2885 cdcchina@contdisc.com INDIA 423/P/11, Mahagujarat Industrial Estate, Moraiya, Sarkhej-Bavla Road, Ahmedabad (GJ) 382213 INDIA Ph +(91) 2717 619 333 Fax +(91) 2717 619 345 gcmpl@contdisc.com Continental Disc Corporation reserves the right to alter the information in this publication without notice. // 2014 Continental Disc Corporation Reproduction without written permission is prohibited. PRINTED IN U.S.A. TCH1284 TEF TMR // 1114