Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Similar documents
Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Troubleshooting Guide

Troubleshooting Guide

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Please read this sheet as it contains important information

100 Series Gas Ventilation Interlock System

VGPS-evo V3.3. Installation Instructions. The VGPS-evo is a gas pressure proving system with ventilation interlock and optional CO2 detection.

GPPS-evo V3.3. Installation Instructions

Multi Function Control System for Boiler and Plant rooms SEC-B. The Home of Control & Automation in Ireland

Installation Instructions

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock.

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

BX444-Mc Gas Detector

OPERATION AND INSTALLATION MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

GS100M Gas Detection Controller

MERLIN RANGE GAS DETECTION EQUIPMENT

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Installation and user manual for the BiWire / Conventional Repeater Panel

GL-CO-RFG Channel Gas Leak Alarm System

GS100M Gas Detector. Technical Specification

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Reflective Optical Beam Smoke Detector User Guide

Installation, Operating and Maintenance Manual

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Door Release Power Supply

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

FEC400 Series. Installation Manual

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

EXAMPLES OF HOW TO ORDER

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

EXAMPLES OF HOW TO ORDER

Operation and Maintenance Manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Beacon 110 Gas Monitor Operator s Manual

Public Safety DAS Annunciator Panel

INSTALLATION AND OPERATING INSTRUCTIONS

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

KM300 Carbon Monoxide Detection System Installation Manual

Installation Instructions 4 Zone Fire Panel

ESP TECHNOLOGIES LIMITED

Carbon Monoxide Transmitter

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

CaterSense 03 & ATSC-02-xx

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

21-light Remote Annunciator. Owner s Manual

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Intelligent Security & Fire Ltd

ACCU-TEST SAFETY. Assured Gas Shut Off Protection

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Water Detection Controllers

QA16 Addressable System

5000 INSTALLATION GUIDE

Beacon 800 Gas Monitor Operator s Manual

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

Conventional Releasing Control Panel

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Control Panels and Fire Detection Equipment

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Fire and Smoke Control Systems

RTD-10 Installation Instructions

FEC403EN Installation Manual

EXTINGUISHING AGENT RELEASE MODULE

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

Transcription:

Gas Safety Products Merlin 1500S Gas Interlock System Installation, operating and maintenance Rev: 03 Date: 08-01-18 1

Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Mains Supply... 3 2.3 Gas solenoid valve.... 3 2.4 Supply Fan & Extract Fan PD Switches.... 3 2.5 BMS Connections.... 3 2.6 Remote emergency shut off buttons.... 3 2.7 Gas Detector.... 3 2.8 FS 123.... 3 2.9 CO2 Monitor.... 3 2.10 12v DC.... 3 2.11 Internal Buzzer.... 3 3 Operation Instructions... 4 3.1 How to turn the system on and off... 4 3.2 Explanation of LED status... 4 3.2.1 Power LED... 4 3.2.2 Gas on LED... 4 3.2.3 Supply fans LED... 4 3.2.4 Extract fans LED... 4 3.2.5 Fan Fault LED... 4 3.2.6 EM Stop LED... 4 3.2.7 Gas Detected LED... 5 3.2.8 CO2 High LED... 5 3.3 CO 2 MODE... 5 3.4 Using the emergency shut off... 5 3.5 BMS integration... 5 3.6 Fire alarm integration... 5 3.7 Fan switch integration... 6 1500S Wiring Diagram... 7 Rev: 03 Date: 08-01-18 2

1 General information The Merlin 1500S is a ventilation interlock panel. The Merlin 1500S can receive connections from up to four external remote air pressure differential switches or current monitors, remote emergency shut-off buttons, gas detectors and a Merlin CO2 monitor. It can also be integrated with a BMS and fire alarm. It is recommended that the user reads this guide before using the system. Please do NOT attempt to operate the unit until the contents of this document have been read and are thoroughly understood. 2 Installation 2.1 Panel Mounting The control panel is designed for surface mounting using 4 mounting screws. Removing the cover on the panel gives access to the circuit board. The PCB should be removed before drilling entry holes into the case. 2.2 Mains Supply A 100-240VAC electrical supply should be supplied to the panel. This should be externally fused at 3 Amps using a fused spur and should be connected to the terminals marked LNE Power 2.3 Gas solenoid valve The gas solenoid valve should be powered using the terminals on the Merlin 1500S marked LNE GAS VALVE. 2.4 Supply Fan & Extract Fan PD Switches These terminals are used to receive an input signal from external air pressure switches or external current monitors. These are linked out as a factory setting. Wiring to the air pd switches & current monitors should be made using two-core volt free connections. If only one fan is being used the terminals not in use should be left linked out. 2.5 BMS Connections Terminal connections are available on the circuit board for connections to Building Management systems etc. Detailed on the circuit board as BMS OUT N/C, Com and N/O these are volt free connections. 2.6 Remote emergency shut off buttons The terminal for remote emergency shut-off buttons is detailed on the circuit board as EM REMOTE. These connections are linked out as a factory setting. Remote emergency shut-off buttons should be volt free and wired to the Merlin 1500S using two-core cable. 2.7 Gas Detector The terminals detailed on the circuit board as Gas Detector. These connections are +,- and these can be wired to a Merlin gas detector. Natural gas, Carbon monoxide or LPG. If no detector is being used leave the link in between the. Other detector types are available. 2.8 FS 123 This terminal switches when the key is turned on and off. This can be linked to a fan switch (panel supplied separately) which can provide power to the fans when the control panel is switched on. 2.9 CO2 Monitor This terminal can be wired to CO2 monitor to shut off the system in the event of CO2 being at alarm level. If no CO2 monitor is supplied leave the terminal link in. 2.10 12v DC This is a permanent 12v DC output when there is power at the panel. This is normally used to power a PM2 current monitor. (Supplied separately) 2.11 Internal Buzzer Operates at 65dB measured 30cm from closed panel. Note: all low voltage connections should be made using a screened cable. To avoid electrical interference this should not be in the same conduit as mains cable as per the low voltage directive. Rev: 03 Date: 08-01-18 3

3 Operation Instructions 3.1 How to turn the system on and off 1. Turn the Fans On. 2. Turn the key switch to on position. 3. To turn the system off, turn the key switch to off position. 3.2 Explanation of LED status 3.2.1 Power LED When the system is connected to the mains supply, the Red LED of the AGS Logo located in the bottom right corner of the panel will illuminate. When no power is present, this LED will not light up. RED = OK OFF = No power to 1500S, a loose ribbon connection or the fuse may not be intact. 3.2.2 Gas on LED When the fans are running at the correct speed and the key switch is turned on, the Merlin 1500S will open the gas valve and the green Gas On LED will illuminate. GREEN = Gas On OFF = Gas Off 3.2.3 Supply fans LED Under normal working the LED will illuminate GREEN. If a supply fan fault is detected, the LED will be flashing. GREEN = OK FLASHING = One of the supply fans is not running. 3.2.4 Extract fans LED Under normal working the LED will illuminate GREEN. If an extract fan fault is detected, the be flashing. GREEN = OK FLASHING = One of the extract fans is not running LED will IF SUPPLY AND/OR EXTRACT FANS LED FLASHES FOR MORE THAN 20 SECONDS, THE Merlin 1500S WILL SHUT OFF THE GAS. 3.2.5 Fan Fault LED Under normal working conditions this LED is off. If a fan fault is present for more than 20 seconds, the LED will illuminate RED. OFF = OK RED = the gas supply has been shut off due to a ventilation fault. IF A FAULT IS FOUND YOU WILL NEED TO CONTACT YOUR SERVICE/MAINTENANCE COMPANY YOU SHOULD NOT ATTEMPT TO CARRY OUT A REPAIR OR RECTIFY THE FAULTS UNLESS YOU ARE QUALIFIED TO DO SO. 3.2.6 EM Stop LED If an emergency shut off button (either remote or on the panel) is pressed, the LED will illuminate AMBER and the gas will be turned off. The EM Stop button must be re-set before restarting the system. OFF = OK AMBER = EM Stop button pressed Rev: 03 Date: 08-01-18 4

3.2.7 Gas Detected LED Under normal working conditions this LED is off. If the external Merlin detector connected detects gas this will show RED and the Gas valve will turn off. OFF = OK RED = Gas detected. 3.2.8 CO2 High LED Under normal working conditions this LED is off. If the concentration of CO2 in the air is at alarm level (relevant detector required), the LED will show RED and the Gas valve will turn off. OFF = OK RED = the concentration of CO2 is at alarm level. 3.3 CO 2 MODE Under normal working conditions the Merlin 1500S monitors the ventilation and the concentration level of CO2. In the event of ventilation failure or if the CO 2 level is at alarm level, the panel will shut off the gas supply. The Merlin 1500S features a CO2 Mode this allows the kitchen to have the access to the gas supply in the event of a fan failure. There is a CO2 Mode button located on the front of the panel. This button will only be available to use when Fan fault LED illuminates Red. To enable the CO2 Mode, the CO2 button has to be pressed for 5 seconds. The Fan Fault LED will go off and CO2 Mode LED will come on. In this mode, the Merlin 1500S will monitor only the CO 2 levels to ensure there is a safe working environment. This mode will allow the gas valve to open for 8 hours each time the system is energised, provided there are satisfactory levels of CO2. At the end of 8 hours, the gas valve will close and CO2 Mode LED will be flashing. To reinstate the system the panel has to be restarted. The CO2 Mode will be permanently disabled if a CO2 Sensor is not detected at power up. 3.4 Using the Emergency Shut Off The Emergency shut off button is located on the front of the panel. There is also a facility for remote shut off buttons to be wired in series. The Emergency shut off button(s) will cut off the gas supply when activated. To reinstate the system, the Emergency shut off button(s) will need to be reset and the panel restarted. 3.5 BMS integration The Merlin 1500S can be integrated with a BMS to make or break a circuit on gas on/gas off, (valve open or valve closed). This will tell the BMS whether or not 100-240VAC is being sent to the solenoid. There is a dip-switch located on the inside facia of the Merlin 1500S labelled BMS Selection. This is factory set in the off position which signals the BMS on gas on/gas off. When switched to the on position, the 1500S will only signal the BMS on a gas detected. 3.6 Fire alarm integration The Merlin 1500S can be integrated with a fire alarm to close the gas supply automatically in the event of a fire. The volt free fire alarm signal can be wired in series with any remote emergency shut off buttons. If there is no remote emergency stop buttons installed wire this directly to the terminal marked EM REMOTE. Rev: 03 Date: 08-01-18 5

3.7 Fan Switch Integration There is the facility to connect a Fan Switch (FS1 or FS2 sold separately). The Fan Switch provides the facility to turn on the fan(s) when the key switch on the Merlin 1500S is in the on position and turn the power off to the fan(s) when the key switch on the Merlin 1500S is in the off position. There is a dip-switch located inside the facia of the Merlin 1500S labelled EM Selection. This is factory set in the off position which instructs the system to shut down the fan(s) and gas supply on activation of the Emergency shut off button(s). On installation, this can be switched to the on position if required. This will instruct the system to leave the fans on and only shut off the gas supply on activation of the Emergency shut off button(s). Note: This option is not available if Fan Switch is not installed. Rev: 03 Date: 08-01-18 6

1500S Wiring Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 L N E Gas Detector CO2 Monitor PM2 Gas Valve PD Switches or Current Switches (Volt Free) EM Stop 1. Mains Input 100-240VAC. 2. Gas Solenoid Valve Power Output, 100-240VAC. 3. This terminal is disabled on this system. 4. This terminal is disabled on this system. 5. Supply Fan 1 external pressure differential switch or current switch. VOLT FREE INPUT 6. Supply Fan 2 external pressure differential switch or current switch. VOLT FREE INPUT 7. Extract Fan 1 external pressure differential switch or current switch. VOLT FREE INPUT 8. Extract Fan 2 external pressure differential switch or current switch. VOLT FREE INPUT 9. BMS output contacts. Normally Closed, Common and Normally Open. Max.1A @ 240VAC. 10. This terminal is disabled on this system. 11. Remote EM Stop buttons and Fire Alarm input wired in series (purchased separately). VOLT FREE INPUT 12. Methane, CO or LPG Detector, power supply and VOLT FREE INPUT (purchased separately). 13. Fan Switch output (purchased separately). For wiring instruction see Fan Switch user manual. 12. CO2 Monitor (purchased separately). VOLT FREE INPUT 13. Permanent 12VDC output (Normally used to power a PM2 Current Monitor). 50A Max. Please note, Mains wires and low voltage wires should not be run in the same conduit as per the LOW VOLTAGE DIRECTIVE Rev: 03 Date: 08-01-18 7

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the materials used. Please contact your supplier or local authority for details of recycling schemes in your area. CONTACT US: AGS Head Office Tel: (727) 608-4375 Fax: (727) 538-4237 info@americangassafety.com American Gas Safety is the owner of this document and reserves all rights of modification without prior notice. Rev: 03 Date: 08-01-18 8