Product Information to the manual

Similar documents
Instrumentation Products and Applications

Operating Instructions Edition 02/2007

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Temperature Measurement Transmitters for field mounting

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare

Model 144H. Product Data Sheet , Rev DB February Content

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Annubar Flowmeter Series

Technical Data. Dimensions

Certificate of Compliance

Assembly. Host Sub-D Alarm

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Technical Data. Dimensions

Indoor/outdoor resistance thermometer Model TR60

Model 144H. Product Data Sheet , Rev DB February Content

Inductive slot sensor

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

PEPPERL+FUCHS GmbH

Continuous level measurement - Radar transmitters

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET. PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Introduction 1. Components of the product

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Level Measurement Continuous level measurement - Ultrasonic transmitters

Rosemount 2051T In-Line Pressure Transmitter

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Engineering Guideline. pac- Carriers Type Universal

Tank Gauging System Special Safety Instruction

SITRANS T temperature transmitters A broad product family for every application. sitrans

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Rosemount 644H and 644R Smart Temperature Transmitters

Technical Data. Dimensions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Continuous level measurement Ultrasonic transmitters

Technical Data. Dimensions

Rosemount 3051CFC Compact Flowmeter

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Pressure Transmitter cerabar S PMC 731/631 cerabar S PMP 731/635 with ma output signal

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

Rosemount 752 Fieldbus Remote Indicator

Differential Pressure Transmitter deltabar S PMD 230/235 deltabar S FMD 230/630/633 with ma output signal

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

OPTIBAR DP 7060 Supplementary Instructions

Danfoss gas detection Controller unit

Operating Instruction OI/TSC400-EN. SensyTemp TSC400 Industrial thermometer. For plug-in connection For screw-in connection For surface measurement

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

TYPE APPROVAL CERTIFICATE

CERTIFICATE OF COMPLIANCE

Connection of CET4-AP to Siemens ET 200S

DF1151-Ex Infrared flame detector

FDOOT241-A9-Ex Multisensor fire detector

Rosemount 2051T In-line Pressure Transmitter

SITRANS F M MAG 3100 P:

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Physikalisch-Technische Bundesanstalt

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Electronic Pressure Digest. Pressure and Temperature Transmitters

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Rosemount 3051CFP Integral Orifice Flowmeter

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

DESCRIPTION. 42 mm. 125 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Dräger Polytron 7000 Fixed gas detector

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

DICTATOR Hold-Open Systems for Hazardous Areas

VERSAFLOW VORTEX Supplementary instructions

FAHM Co. Temperature Transmitter PTT74 Series

Rosemount 3051L Level Transmitter

Intrinsically Safe Transmitters, Option Code 2n

Functional Safety Manual June pointek CLS500/LC500

OOH740-A9-Ex Multi-sensor fire detector

Enraf Servo Gauge 854 XTG

Manual Power relay SR853

TYPE APPROVAL CERTIFICATE

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Flow Measurement. Product overview. 3/2 Siemens FI Overview. Siemens AG Software for parameterization

DF1101-Ex Infrared flame detector

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

Rosemount 848T High Density Temperature Measurement Family

ASIsafe Solution PROFIsafe

Technical Data. General specifications. Rated operating distance s n 5 mm

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

DB5 Intrinsically Safe Sounder Type DB-5

4) Intrinsic Safety Certification

Transcription:

Product Information to the manual Distributed I/O device ET 200iS, Version 10/2001 Introduction This product information contains fixes and additional information relevant to the user manual Distributed I/O device ET 200iS, versions 10/2001, order no. 6ES7 151-2AA00-8BA0. 1 Configuration options in zones: see Chapter 4.4 in the ET 200iS Manual Rules for the configuration of ET 200iS in Zone 1, Zone 2 and in the safety area Note Connect the fieldbus isolation transformer to the start of the PROFIBUS-DP segment. The fieldbus transformer is always required and must be installed in the safety area! Enable the terminating resistor on the fieldbus isolation transformer. Copyright 2004 by Siemens AG

2 Using ET 200iS in a redundant DP standard master system: see Chapter 4.7 of the ET 200iS manual Restrictions Since SIMATIC PDM can not access ET 200iS via the Y link, it must be connected to the PROFIBUS-DP segment downstream of the Y link (secondary side). 3 Limitation of the number of connectible electronic modules/maximum configuration: see Chapter 4.8 of the ET 200iS manual Number of electronic modules Each ET 200iS station consists of a maximum of 32 electronic modules, including digital and analog electronic modules. The actual number of electronic modules is often limited by the safety relevant maximum for which the system is designed (Limit value: < 7000 ma). the of the power supply module PS. This limit (maximum permitted) depends on ambient temperature at the PS power supply module and may not be exceeded. Unrestricted use and combination of modules in an ET 200iS is possible with the configurations shown below: ET 200iS up to 20 electronic modules, at an ambient temperature of 40 C (Limit value: < 5000 ma) ET 200iS up to 19 electronic modules, at an ambient temperature of 50 C (Limit value: < 4650 ma) ET 200iS up to 17 electronic modules, at an ambient temperature of 60 C (Limit value: < 4300 ma) For operation with a higher number of electronic modules (maximum 32) you must check you configuration according to the calculation table (see Table 1). 2

Calculation table Use the calculation table to check the safety relevant and typical consumption of ET 200iS. These typical values represent those of an average plant configuration. The following simultaneity factors apply to the ET 200iS station: with DI of 65 % with DO of 80 % with AI of 80 % with AO of 80 % If the specified simultaneity factors are too low for your application, you must base the calculated consumption on maximum values (see Chapter 5 in this product info). Procedure You must check the safety relevant and typical consumption of your ET200iS configuration!the limit values specified in the table columns =safety relevant consumption in ma and = typical consumption in ma must not be exceeded. 1. Multiply the safety relevant value of each module by the number of modules and then enter the result in the column x Number of modules and = and safety relevant consumption in ma. 2. Multiply the typical value of each module by the number of modules and then enter the result in the column = typical consumption in ma. 3. Add all modules and enter the value in the field Total number of modules (max. 32 electronic modules). 4. Add the safety relevant consumption and enter the sum in the field Accumulative consumption. 5. Add the typical consumption and enter the sum in the field Accumulative consumption. 6. Compare the calculated sum totals with the specified limit values. 3

Table 1 Current consumption calculation table Electronic modules x number of modules safety relevan t per module in ma = safety relevant consumption in ma. typical per module in ma 4DI NAMUR x 200 ma = 80 ma = 2DO 25VDC/25mA 1 x 330 ma = 240 ma = 2DO 25VDC/25mA 2 x 330 ma = 160 ma = 2AI I 2WIRE x 330 ma = 200 ma = 2AI I 4WIRE x 120 ma = 50 ma = 2AI RTD x 120 ma = 50 ma = 2AI TC x 120 ma = 50 ma = 2AO I x 330 ma = 200 ma = 2AI I 2WIRE HART x 330 ma = 200 ma = 2AI I 4WIRE HART x 120 ma = 50 ma = 2AO I HART x 330 ma = 200 ma = Total number of modules = max. 32 Total consumption = < 7000 ma 1 The maximum consumption of the connected valves is 25 ma. 2 The maximum consumption of the connected valves is 12 ma. Simultaneity factors with typ. DI: 65%, DO: 80%, AI: 80%, AO: 80% = typical consumption in ma Accumulative consumption = < 5000 ma at 40 C < 4650 ma at 50 C < 4300 ma at 60 C Example An ET 200iS is operated at an ambient temperature of 50 C. It consists of the following electronic modules: 5 modules 4DI NAMUR, 5 modules 2DO 25VDC/25mA with 25 ma valves 2 modules 2DO 25VDC/12mA with 25 ma valves 3 modules 2AI I 2WIRE 4

5 modules 2AI I 4WIRE 5 modules 2AI RTD 4 modules 2AI TC 3 modules 2AO I When operating with 32 electronic modules at an ambient temperature of 50 C, the consumption needs to be checked (< 4650 ma and < 7000 ma): Table 2 Current consumption calculation table Electronic modules x number of modules safety relevan t per module in ma = safety relevant consumption in ma. typical per module in ma = typical consumption in ma 4DI NAMUR x 5 200 ma = 1000 ma 80 ma = 400 ma 2DO 25VDC/25mA 1 x 5 330 ma = 1650 ma 240 ma = 1200 ma 2DO 25VDC/25mA 2 x 2 330 ma = 660 ma 160 ma = 320 ma 2AI I 2WIRE x 3 330 ma = 990 ma 200 ma = 600 ma 2AI I 4WIRE x 5 120 ma = 600 ma 50 ma = 250 ma 2AI RTD x 5 120 ma = 600 ma 50 ma = 250 ma 2AI TC x 4 120 ma = 480 ma 50 ma = 200 ma 2AO I x 3 330 ma = 990 ma 200 ma = 600 ma 2AI I 2WIRE HART x 330 ma = 200 ma = 2AI I 4WIRE HART x 120 ma = 50 ma = 2AO I HART x 330 ma = 200 ma = Total number of modules = 32 modules max. 32 Total consumption = 6970 ma result is OK! < 7000 ma 1 The maximum consumption of the connected valves is 25 ma. 2 The maximum consumption of the connected valves is 12 ma. Simultaneity factors with typ. DI: 65%, DO: 80%, AI: 80%, AO: 80% Total consumption = 3820 ma result is OK! < 5000 ma at 40 C < 4650 ma at 50 C < 4300 ma at 60 C 5

Note The limit values were complied with under both conditions (safety relevant and typical consumption). The ET 200iS can therefore be operated with this configuration. It must be ensured that the maximum ambient temperature of 50 C at the power supply module PS is not exceeded. 4 Installation rules: see Chapter 5.1 of the ET 200iS manual Cubicle for ET 200iS in Zone 1 The ET 200iS must be installed in a metal cubicle (stainless steel or steel sheet) of the protection class EEx e (Increased safety). Cubicle for ET 200iS in Zone 2 The ET 200iS must be installed in a metal cubicle (stainless steel or steel sheet) of the minimum protection class IP 54. A manufacturer s declaration of compatibility has to be available for operation of the cubicle in Zone 2 (according to EN 50021). 6

5 Technical data of the electronic modules: see Chapters 13, 14 and 15 of the ET 200iS manual Maximum consumption of the electronic modules Valid for the maximum consumption is a simultaneity factor of 100 %, that is, all channels of the ET 200iS station are active simultaneously under maximum power consumption. Table 3 Maximum consumption of the electronic modules Electronic module 4DI NAMUR 2DO 25VDC/25mA1 2DO 25VDC/25mA 2 2AI I 2WIRE 2AI I 4WIRE 2AI RTD 2AI TC 2AO I 2AI I 2WIRE HART 2AI I 4WIRE HART 2AO I HART Maximum consumption in ma 90 ma 270 ma 170 ma 250 ma 50 ma 50 ma 50 ma 250 ma 250 ma 50 ma 250 ma 1 The maximum consumption of the connected valves is 25 ma. 2 The maximum consumption of the connected valves is 12 ma. 7

6 Standards and certifications for the power supply module The power supply module itemised in Table 4 fulfills the following standards and certifications. Table 4 Power supply module Power supply module Power supply module Order no. 6ES7138-5EA00-0AA0 ATEX certification PTB 01 ATEX 2121 according to EN 1127-1:1997, EN 50014:1997+A1+A2, EN 50018:1994, EN 50019:1994 and EN 50020:1994 II 2 G EEx de [ib/ia] IIC/IIB T4 The EC declarations of conformity are kept on file at the following address for the authorities in charge: Siemens Aktiengesellschaft Automation and Drives Division A&D AS RD ST Type Test Postfach 1963 D-92209 Amberg UL/CSA certification See Control Drawing A5E00158421-01 HAZ. LOC. FM certification See Control Drawing A5E00158421-01 8

7 Standards and certifications for the interface module The interface module itemised in Table 5 fulfills the following standards and certifications. Table 5 Interface module Interface module Interface module Order no. 6ES7151-2AA00-0AB0 ATEX certification PTB 01 ATEX 2122 according to EN 50014:1997+A1+A2 and EN 50020:1994 II 2 G EEx ib IIB/IIC T4 The EC declarations of conformity are kept on file at the following address for the authorities in charge: Siemens Aktiengesellschaft Automation and Drives Division A&D AS RD ST Type Test Postfach 1963 D-92209 Amberg UL/CSA certification See Control Drawing A5E00158421-01 HAZ. LOC. FM certification See Control Drawing A5E00158421-01 9

8 Standards and certifications of the electronics modules The electronics modules itemised in Table 6 fulfill the following standards and certifications. Table 6 Electronics modules Electronics modules 4DI NAMUR 2DO DC25V/25mA 2AI I 2WIRE 2AI I 4WIRE 2AI RTD 2AI TC 2AI I 2WIRE HART 2AI I 4WIRE HART 2AO I 2AO I HART Order no. 6ES7131-5RD00-0AB0 6ES7132-5SB00-0AB0 6ES7134-5RB00-0AB0 6ES7134-5RB50-0AB0 6ES7134-5SB50-0AB0 6ES7134-5SB00-0AB0 6ES7134-5TB00-0AB0 6ES7134-5TB50-0AB0 6ES7135-5RB00-0AB0 6ES7135-5TB00-0AB0 ATEX certification KEMA 01 ATEX 1150, 1151, 1152, 1153, 1154, 1155, 1156 X according to EN 50014:1997, EN 50020:1994 and EN 50284:1999 II 2 G (1) GD EEx ib [ia] IIC T4 The EC declarations of conformity are kept on file at the following address for the authorities in charge: Siemens Aktiengesellschaft Automation and Drives Division A&D AS RD ST Type Test Postfach 1963 D-92209 Amberg Note Electronics modules of device category 2G may be used in zone 1 hazardous areas. Sensors of device categories 1G, 2G and 3G may be connected to the intrinsically safe inputs of the electronics modules for zones 0, 1 and 2; sensors of device categories 1D, 2D and 3D may be used for zones 20, 21 and 22. 10

UL/CSA certification See Control Drawing A5E00158421-01 HAZ. LOC. FM certification See Control Drawing A5E00158421-01 11

12