VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

Similar documents
VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

VISTA-128B. Installation and Setup Guide. Commercial Burglary. Partitioned Security System. with Scheduling K3271 7/98

Expansion Modules & Accessories

&RPPHU LDO)LUHDQG%XUJODU\

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Vista-128FB System Design Sheet

VISTA-128FB. Installation and Setup Guide. Commercial Fire & Burglary Partitioned Security System with Scheduling

Vista-50P/-50PUL System Design Sheet

Commercial Fire and Burglary Partitioned Security System with Scheduling

DS7400Xi Addressable Control/ Communicator

&RPPHUFLDO)LUHDQG%XUJODU\

Honeywell Combination Fire & Burglary Control Panel

&RPPHUFLDO%XUJODU\ ,QVWDOODWLRQDQG6HWXS*XLGH 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 3 STAY 1 OFF 6BYPASS 5 TEST 4 MAX 9 CHIME 7 INSTANT OFF 2 AWAY

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

Vista-10SE System Design Sheet

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

Vista-20SEUL System Design Sheet

P Zone Expandable Hybrid Security System

Commercial Burglary Partitioned Security System With Scheduling. Installation and Setup Guide. N5944-6V2 5/04 Rev B

V2 1/13 Rev C

If you want to. grow your business expand your. expectations.

VISTA-100 Commercial Fire & Burglary Partitioned System

VISTA-100. COMMERCIAL FIRE AND BURGLARY PARTITIONED SECURITY SYSTEM with SCHEDULING. INSTALLATION INSTRUCTIONS and PROGRAMMING GUIDE N6019-2V1 1/98

EVO192 v3.0 Fire and Burglary What s New

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Installation Guide. Control/Communicator

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Addressable Fire Alarm Control Panel

VISTA-50P VISTA-50PUL

Integrated Solutions. Integrated Solutions HONEYWELL SECURITY & COMMUNICATIONS. More and more, customer requirements cannot

VISTA-40. Installation and Setup Guide. 2-Partition Security System N7001V4 7/98

WIRELESS CONTROLS & DETECTORS

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

First Alert 1200C Installer Notes M. Leuck

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

ADEMCO CONTACT ID REPORTING (revised )

OmniPro II. Technical Sheet. DESCRIPTION

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

9,67$36HULHV 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH. The formatting of this version has been significantly revised. K5305-1V3 10/03 Rev.

D2412 Control / Communicator Installation Manual

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Model 17A00 Expansion Enclosure

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

9,67$&1 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH K3892V1 4/00

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

UltraSync Modular Hub

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling.

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

FA130CP. Installation and Set-Up Guide. K0735-1V1 4/04 Rev. A OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 READY R BYPASS MAX

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

INSTALLATION INSTRUCTIONS

System Overview. PC4020 v3.3

AL800ULADA. NAC Power Extender. Installation Guide

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Integrated Security Solutions

Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem

&RPPHUFLDO)LUHDQG%XUJODU\ 6HFXULW\6\VWHP ZLWK6FKHGXOLQJ ,QVWDOODWLRQDQG6HWXS*XLGH 35(/,0,1$5< -8/< K3822V2 6/01

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

Security & Communications INTRUSION AND ALARM COMMUNICATIONS

PC4020 v3.2 Installation Manual DLS-3 v1.3

D7024 Fire Alarm Control Panel

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Integrated Security Solutions

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Addressable NAC Output Module D327A

System Introduction. 1.1 Specifications S E C T I O N 1

Installation Instructions

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM.

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

XR10/XR20 Command Processor Panels Installation Guide

RE6100 Series Helix Security and Automation Platform

/<1; 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH N8889V1 10/98 OFF AWAY STAY AUX

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

good things in small packages

All-In-One Wireless Security System V1.0. Model #: MG-6060

Transcription:

Designed to integrate seamlessly with, access control and ADEMCO s full range of fire and burglary components, the VISTA-32FB provides the ultimate protection of life and property. The UL listed Fire and Burglary Control Platform can control up to two separate partitions independently, and supports up to 32 zones/points using hardwired, wireless and addressable technologies. A diverse line of ADEMCO initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays support this extremely powerful control platform. Advanced technology, combined with simple end-user operation, make the versatile VISTA-32FB the smartest choice for the most demanding applications. Fire/Burg/ and Access Control Platform FEATURES: Supports addressable access control points using VistaKey (1 to 4 doors) Supports up to 16 doors of access control using Vista Gateway (VGM)* Supports applications with the new VistaView-100 Switcher Identifies the point or zone of a fire using the new FSA-8/FSA-24 Fire System Annunciator Supports eight hardwired zones, 24 addressable points/zones, or 32 wireless points/zones Can control two separate areas (partitions) independently Stores up to 512 events and can accommodate 75 user codes New E2 Software Simplifies Programing Easily programmed and maintained with newly upgraded Compass Downloader Software Automatic smoke detector sensitivity maintenance testing UL Fire and Burg * Connects to Northern Computer s PassPoint Systems. Maximum 32 doors.

Additional Features Notification Appliance Circuits (two): Programmable Temporal code compliant Individually silenceable Programmable on-board auxiliary relay SIA false alarm reduction features: Exit error logic Exit delay reset Cross zoning Call waiting defeat Recent close report Supports commercial hardwired, addressable polling loop and wireless zones Hardwired zones Provides nine style B hardwired zones EOLR supervised for Fire and UL burglary installations Supports N.O or N.C. sensors Individually assignable to one or all eight partitions Up to 16 two-wire smoke detectors each on zone one and two (32 total) Up to 50 two-wire glassbreak detectors on zone eight Patented addressable polling loop technology Supports up to 24 two-wire zones/points Global polling technology for faster processing Increased current draw capacity (128mA) Supervised by panel Individually assignable to partitions, notification circuit (bell) output or aux relay 4,000 ft capability without the use of shielded cable Extender/Isolation bus module Two-wire smoke detector zone/group expansion module adds two or four zones Eight zone Class A and B extender module Eight zone Class B extender module One zone supervised contact monitor module UL Listed wireless expansion Supports up to 32 wireless zones/points using 5881ENHC Supervised by control for check-in signals Tamper protection for transmitters Individually assignable up to eight partitions Supports UL864/NFPA approved wireless smoke detectors Event reporting Local printer of access or VISTA related event Scheduled uploading of events to central station Up to four doors using VistaKey Supported by a diverse line of ADEMCO initiating devices, the VISTA-32FB is well suited for a variety of smaller to medium sized applications as an integrated fire and burglary control including restaurants, small retail stores and shops, churches and synagogues, strip malls, larger residences and small factory and warehouse environments. Stored events for one call retrieval Communication Phone mapping by zone response type Supports VIP Interactive Phone Voice Panel operation during download Uploading equipment list to central station Communication to PassPoint via Vista Gateway 9500SN Glassbreak Sensor 4101SN Relay 4208U 4293SN V-Plex Adapter 5192 Series V-PLEX Loop 6160CR Red Alpha Console 5881ENHC 4208SNF With Two Class A Zones 4278EX Quad P ECP Bu VistaKey V-Plex VistaView-100 Switcher 4204 Relay NAC (Bell) Circuit 4204CF }Eight Class B Hardware Zones 4146 Key Switch Option 5140 LED Communicator Status RS232 4100SM Printer Interface 6220S Printer Phone Line to Central Station 7720ULF Long Range Radio 7845C Cellular

Applications The VISTA-32FB control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-32FB alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. Specifications Electrical: Primary power: 18VAC @ 72VA ADEMCO No. 1451 Quiescent current draw: 350mA Backup battery: 12VDC, 7AH min to 34.4AH max Lead acid battery (gel type) Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Aux. standby pwr: 12VDC, 1A max Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources 24 hours with 1A standby load or 60 hours with 205mA max standby load using 34.4AH battery Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Main Dialer: Line seize: Double Pole Ringer equiv.: 0.7B Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Cabinet dimensions: 14.5 H X 12.5 W X 3 D Environmental: Storage temp: -10 C to 70 C Operating temp: 0 C to 50 C Humidity: 85% RH EMI: Meets or exceeds the following requirements: FCC Part 15, Class B Device FCC Part 68 IEC EMC Directive Agency Listings Burglary FCC Part 15, Class B; FCC Part 68 UL Residential and UL864/NFPA Local Fire UL864/NFPA Central and Remote Station Fire UL609 Grad A Local Mercantile Premises/Local Mercantile Safe and Vault UL365 police station connected burglar alarm Grade AA Service (with LRR Model 7920SE) UL611/UL610 Central Station Burglar Alarm California State Fire Marshal FM Manual Pull Stations 5140MPS-1* 5140MPS-2* IR 4193SN Serial Interface 5881 (Max Two) 4190SN V-Plex Two-Zone Expander 4944SN Addressable Recessed Mount Contact Q2260SN Multiplex DUAL TEC Motion Detector Tamper Switch* Flow Switch* Low Temp Switch* 6139R 32 Character Red-Alpha Keypad 4204CF Supervised NAC Notification Appliance 5816 Door/Window Miniature 5800 Series Devices 5869 Hold-Up Switch 5890 PIR 5817CB 4209U Group Zoning Supports Up To 16 Supports Up To 32 VGM (PTVGM) Vista Gateway PassPoint *Use with 4193SN Mini-Zone

SPECIFICATIONS: Fire/Burg/ and Access Control Platform 165 Eileen Way, Syosset, NY 11791 Copyright 2002 Pittway Corporation ADEMCO is an ISO9001 Registered Company Compatible Devices See ADEMCO Group control accessories compatibility chart for complete list Auxiliary devices 4204 Relay, four form C contacts 4204CF Two supervised output circuits 5140DLM, Supervised Dialer 5881 Series RF supporting 5800 wireless detectors 6160CR Red Alpha Keypad 6139R Red Alpha Keypad/annunciator 6220S System printer used with 4100SM serial module FSA-8, FSA-24 Fire Annunciators Two-wire smoke detectors conventional: System Sensor smoke detectors Horn/Strobes: System Sensor Manual Pull Stations: 5140MPS-1 5140MPS-2 V-Plex (addressable) Devices: 4101SN Relay Zone 4190SN Remote Point two zones 4190WH 4193SN Two Zone Serial Interface 4208U Loop eight zones 4208SNF Eight Zone/2 Class A/6 Class B Expander 4209U Group Zoning two/four zones 4293SN One Zone Serial Interface 4297 Isolation/Extender VistaView-100- Switcher V-Plex (addressable) : 5192SD 5192SDT Vista Interactive Phone : 4286 Voice Passive Infrared : 998MX 4275EX-SN 4278EX-SN QUEST2260SN V-Plex (addressable) Contacts: 4194WH, 4193SN 4939SN-WH 4944SN-WH 4959SN Glassbreak : 9500SN Long Range Radio: 7720ULF 7845C Cellular Radio Upgraded software: Upgraded Compass Downloader Windows compatible Devices: 5804 Key 5804BDV Bi-directional with voice 5804BD Bi-directional Key 5808C - Detector 5816 Door/Window 5819 Shock Sensor 5827BD Bi-directional Keypad 5849 Glassbreak Detector 5890 PIR : VistaKey V-Plex (addressable) VistaKey-SK Starter Kit VistaKey-EX Kit VGM Vista Gateway to PassPoint (Northern Computers) Devices: - Detector 5809 - Heat Detector 5817CB - 5869 - Hold up 5881ENHC - Fire/Burg ORDERING: Part No. Description VISTA-32FB Fire and Partitioned Burglary Alarm Platform L/VIST32FB/D 1/02

Additional Features Notification Appliance Circuits (two): Programmable Temporal code compliant Individually silenceable Programmable on-board auxiliary relay SIA false alarm reduction features: Exit error logic Exit delay reset Cross zoning Call waiting defeat Recent close report Supports commercial hardwired, addressable polling loop and wireless zones Hardwired zones Provides nine style B hardwired zones EOLR supervised for Fire and UL burglary installations Supports N.O or N.C. sensors Individually assignable to one or all eight partitions Up to 16 two-wire smoke detectors each on zone one and two (32 total) Up to 50 two-wire glassbreak detectors on zone eight Patented addressable polling loop technology Supports up to 24 two-wire zones/points Global polling technology for faster processing Increased current draw capacity (128mA) Supervised by panel Individually assignable to partitions, notification circuit (bell) output or aux relay 4,000 ft capability without the use of shielded cable Extender/Isolation bus module Two-wire smoke detector zone/group expansion module adds two or four zones Eight zone Class A and B extender module Eight zone Class B extender module One zone supervised contact monitor module UL Listed wireless expansion Supports up to 32 wireless zones/points using 5881ENHC Supervised by control for check-in signals Tamper protection for transmitters Individually assignable up to eight partitions Supports UL864/NFPA approved wireless smoke detectors Event reporting Local printer of access or VISTA related event Scheduled uploading of events to central station Up to four doors using VistaKey Supported by a diverse line of ADEMCO initiating devices, the VISTA-32FB is well suited for a variety of smaller to medium sized applications as an integrated fire and burglary control including restaurants, small retail stores and shops, churches and synagogues, strip malls, larger residences and small factory and warehouse environments. Stored events for one call retrieval Communication Phone mapping by zone response type Supports VIP Interactive Phone Voice Panel operation during download Uploading equipment list to central station Communication to PassPoint via Vista Gateway Applications The VISTA-32FB control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-32FB alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. Specifications Electrical: Primary power: 18VAC @ 72VA ADEMCO No. 1451 Quiescent current draw: 350mA Backup battery: 12VDC, 7AH min to 34.4AH max Lead acid battery (gel type) Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Aux. standby pwr: 12VDC, 1A max Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources 24 hours with 1A standby load or 60 hours with 205mA max standby load using 34.4AH battery Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Main Dialer: Line seize: Double Pole Ringer equiv.: 0.7B Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Cabinet dimensions: 14.5 H X 12.5 W X 3 D Environmental: Storage temp: -10 C to 70 C Operating temp: 0 C to 50 C Humidity: 85% RH EMI: Meets or exceeds the following requirements: FCC Part 15, Class B Device FCC Part 68 IEC EMC Directive Agency Listings Burglary FCC Part 15, Class B; FCC Part 68 UL Residential and UL864/NFPA Local Fire UL864/NFPA Central and Remote Station Fire UL609 Grad A Local Mercantile Premises/Local Mercantile Safe and Vault UL365 police station connected burglar alarm Grade AA Service (with LRR Model 7920SE) UL611/UL610 Central Station Burglar Alarm California State Fire Marshal FM Manual Pull Stations 5140MPS-1* 5140MPS-2* 9500SN Glassbreak Sensor 4101SN Relay 4208U VistaKey V-Plex 4293SN V-Plex Adapter 5192 Series V-PLEX Loop 4204 Relay } 6160CR Red Alpha Console Eight Class B Hardware Zones 4146 Key Switch Option 5881ENHC NAC (Bell) Circuit 4204CF 5140 LED Communicator Status 4208SNF With Two Class A Zones VistaView-100 Switcher 4278EX Quad PIR ECP Bus 4193SN Serial Interface 6139R 32 Character Red-Alpha Keypad 4204CF Supervised NAC 5881 (Max Two) 4190SN V-Plex Two-Zone Expander Notification Appliance 5816 Door/Window Miniature 5800 Series Devices 5869 Hold-Up Switch 4944SN Addressable Recessed Mount Contact 5890 PIR 5817CB Q2260SN Multiplex DUAL TEC Motion Detector 4209U Group Zoning Supports Up To 16 Tamper Switch* Flow Switch* Low Temp Switch* RS232 4100SM Printer Interface 6220S Printer Supports Up To 32 VGM (PTVGM) Vista Gateway PassPoint Phone Line to Central Station 7720ULF Long Range Radio 7845C Cellular *Use with 4193SN Mini-Zone