STANDARD CONFORMANCE

Similar documents
STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

FIBER OPTIC TESTING JIM HAYES OVERVIEW

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Fiber Optics for Todays Industry Applications

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

DNVGL-CP-0402 Edition February 2016

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Basic Professional Fiber Optic Installation

HELKAMA. Optical Fibre Cables

Hands-On CAT 5/6 & Fiber Optic Installer

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

INTERNATIONAL STANDARD

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Jan07 Rev B

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

This is a preview - click here to buy the full publication

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Optical Time Domain Reflectometry (OTDR)

Certified Fibre Optic Specialist - Testing

Qualification Test Report LC Duplex Adapter For LC Cutouts

Ensuring Cabling Performance in the Customer-Owned Outside Plant

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

Field Test Procedure for Optical Fibre Link Measurements

ITU-T L.404. Field mountable single-mode optical fibre connectors

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Fibre (TIA) Field Test Specification

Clearlite Photonic Fibers

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Apr06 Rev A

INTERNATIONAL STANDARD

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

Fibre Optic Basics FIA Summer Seminar 2014

4120 Fire Alarm Network Reference

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Based Fiber Optic Sensors

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

AS/NZS ISO/IEC :2012

Optical Fibres ELEC8350

Special Provision No. 683S28 December 2017

Fiber Optic Patch Cord and Pigtails

Broadband System - H

Dome Fiber Optic Closure SC-221

Fli'l HEWLETT. Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution

The True Value of Connector Inspection: New Challenges and Best Practices

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Figure 1 - Parts of a Fiber Optic Connector

New optical frequency domain differential mode delay measurement method for a multimode optical fiber

Fibrlok II 2529 Universal Optical Fiber Splice

White Paper Fiber optic connections: check and clean first, then connect!

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Four channel video link For low cost video transmission

INTERNATIONAL STANDARD

The Rise of Tier 2 Testing

industry solutions: military

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Duct Cable GYTS-144B1.3

OFS IV Optical Fibre System

Fibre Specification Standards

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

INTERNATIONAL STANDARD

Jul07 Rev C

Chapter 1. Introduction

G4 Pulsed Fiber Laser

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Propagation loss in optical fibers (01/29/2016)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fiber Optic Distribution Cables (6-144 Fibers)

Distributed sensing based on reflections and Rayleigh backscatter. Brian Culshaw University of Strathclyde Glasgow Scotland

OPTICAL FIBER SOLUTIONS

INTERNATIONAL STANDARD

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

62 MAX/62 MAX + Infrared Thermometer. Users Manual

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

DEGRADATION OF OPTICAL FillERS AT CARBON-CARBON PYROLYSIS. Rockwell International Science Center P.O. Box 1085 Thousand Oaks, CA 91358

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

A leading resource for the cable industry

INTERNATIONAL STANDARD

Instruments Designed for POF & Fibre Optic Cable Testing

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

ETSI TS V1.2.1 ( )

64 Max IR Thermometer

G4 Pulsed Fiber Laser

Cooled Butterfly 980nm Pump Laser Module

Luna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Transcription:

STANDARD CONFORMANCE IEC 60331-11, Tests for electric cables under fire conditions- Circuit integrity- Fire alone at a flame temperature of at least 750C IEC 60331-21, Tests for electric cables under fire conditions- Circuit integrity- Cables of rated voltage upto and including 0.6/1.0kv IEC-60793-1-20, Measurement Methods and Test Procedures- Fiber Geometry IEC-60793-1-21, Measurement Methods and Test Procedures- Coating Geometry IEC-60793-1-22, Measurement Methods and Test Procedures- Length Measurement IEC-60793-1-30, Measurement Methods and Test Procedures- Fiber Proof Test IEC-60793-1-31, Measurement Methods and Test Procedures- Tensile Strength IEC-60793-1-32, Measurement Methods and Test Procedures- Coating Strippability IEC-60793-1-33, Measurement Methods and Test Procedures- Stress Corrossion Susceptability IEC-60793-1-34, Measurement Methods and Test Procedures- Fiber Curl IEC-60793-1-40, Measurement Methods and Test Procedures- Attenuation IEC-60793-1-41, Measurement Methods and Test Procedures- Bandwidth IEC-60793-1-43, Measurement Methods and Test Procedures- Numerical aperture IEC-60793-1-44, Measurement Methods and Test Procedures- Cutoff wavelength IEC-60793-1-45, Measurement Methods and Test Procedures- Mode Field Diameter IEC-60793-1-46, Measurement Methods and Test Procedures- Monitoring of changes in optical transmittance IEC-60793-1-47, Measurement Methods and Test Procedures- Macrobending loss IEC-60793-1-52, Measurement Methods and Test Procedures- Change of temperature IEC-60793-1-53, Measurement Methods and Test Procedures- Water Immersion IEC-60794-2-1, Generic Specifications : Optical Fiber Cables Part 1-1

IEC 60793-2, Optical fibes -Product Specifications IEC-60794-4-1, Optical Fiber Cables : Part 4-1: Aerial Optical cables for high voltage power lines IEC 332-1, Part 1; Tests on Electrical Cables under fire conditions IEC 332-3, Tests on electrical cables under fire conditions, Part 3 IEC 60793-1-1, Optical Fibers-Part-1-1 Measurement methods and test procedures -General and guidance IEC 60794-1-2, Optical Fiber cables EIA-445 Fiber Optic Test Procedures (FOTPs) (These are commonly known as "FOTPs" but are officially called "EIA-455-x, e.g. EIA-455-34 is FOTP-34) FOTP-3 Temperature Effects Measurement Procedure for Optical Fiber, Optical Cable, and Other Passive Components FOTP- 1 3 Visual and Mechanical Inspection of Fibers, Cables, Connectors, and Other Devices FOTP-20 Measurement of Change in Optical Transmittance FOTP-25 Repeated Impact Testing of Fiber Optic Cables and Cable Assemblies FOTP-27 Fiber Diameter Measurements FOTP-28 Measurement of Dynamic Tensile Strength of Optical Fiber FOTP-31 Fiber Tensile Proof Test Method FOTP-33 Fiber Optic Cable Tensile Loading and Bending Test FOTP-37 Fiber Optic Cable Bend Test, Low and High Temperature FOTP-41 Compressive Loading Resistance of Fiber Optic Cables FOTP-43 Output Near Field Radiation Pattern Measurement of Optical FOTP-45 Microscopic Method for Measuring Fiber Geometry of Optical FOTP-46 Spectral Attenuation Measurement (Long Length Graded Index Optical Fibers) FOTP-47 Output Far Field Radiation Pattern Measurement FOTP-48 Measurement of Optical Fiber Cladding Diameter Using Laser- Based Instruments FOTP-49 Measurement for Gamma Irradiation Effects on Optical Fiber and Cables FOTP-50 Light Launch Conditions (Long Length Graded Index Fibers) FOTP-51 Pulse Distortion Measurement, Multimode Fiber FOTP-53 Attenuation by Substitution (Multimode Graded Index) FOTP-54 Mode Scrambler Requirements for Overfilled Launching Conditions (Multimode) FOTP-55End View Methods for Measuring Coating and Buffer Geometry FOTP-56 Test Method for Evaluating Fungus Resistance of Optical and Cables FOTP-57 Optical Fiber End Preparation and Examination FOTP-58 Core Diameter Measurements (Graded Index Fibers) FOTP-59 Measurement of Fiber Point Defects Using an OTDR FOTP-60 Measurement of Fiber or Cable Length Using an OTDR FOTP-61 Measurement of Fiber or Cable Attenuation Using an OTDR

FOTP-62 Optical Fiber Macrobend Attenuation FOTP-63 Torsion Test for Optical Fiber FOTP-65 Flexure Test for Optical Fiber FOTP-66 Test Method for Measuring Relative Abrasion Resistance FOTP-68 Optical Fiber Microbend Test Procedure FOTP-69 Evaluation of Minimum and Maximum Exposure Temperature on the Optical Performance of Optical Fiber FOTP-71 Measurement of Temperature Shock Effects on Components FOTP-75 Fluid Immersion Test for Optical FOTP-77 Procedure to Qualify a Higher-Order Mode Filter for Measurements of Single-mode Fibers FOTP-78 Spectral Attenuation Cutback Measurement (Single-mode) FOTP-80 Cutoff Wavelength of Uncabled Single-mode Fiber by Transmitted Power FOTP-81 Compound Flow (Drip) Test for Filled Fiber Optic Cable FOTP-82 Fluid Penetration Test for Fluid-Blocked CablC- FOTP-83 Cable to Interconnecting Device Axial Compressive Loading FOTP-84 Jacket Self-Adhesion (Blocking) Test for Cables FOTP-85 Fiber Optic Cable Twist Test FOTP-86 Fiber Optic Cable Jacket Shrinkage FOT'P-87 Fiber Optic Cable Knot Test FOTP-88 Fiber Optic Cable Bend Test FOTP-89 Fiber Optic Cable Jacket Elongation and Tensile Strength Test FOTP-91 Fiber Optic Cable Twist-Bend Test FOTP-92 Optical Fiber Cladding Diameter and Noncircularity Measurement by Fizeau Interferometry FOTP-94 Fiber Optic Cable Stuffing Tubing Compression FOTP-95 Absolute Optical Power Test for Fibers and Cables FOTP-96 Fiber Optic Cable Long-Term Storage Temperature Test for Extreme Environments FOTP-98 Fiber Optic Cable External Freezing Test FOTP-99 Gas Flame Test for Special Purpose Cable FOTP- I 00 Gas Leakage Test for Gas Blocked Cable FOTP- I 0 1 Accelerated Oxygen Test FOTP- 102 Water Pressure Cycling FOTP- 104 Fiber Optic Cable Cyclic Flexing Test FOTP- 1 07 Return Loss for Fiber Optic Components FOTP- 127 Spectral Characterization of Multimode Laser Diodes FOTP-162 Fiber Optic Cable Temperature-Humidity Cycling FOTP-164 Measurement of Mode Field Diameter by Far-Field Scanning (Single-mode) FOTP-165 Measurement of Mode Field Diameter by Near Field Scanning (Single-mode) FOTP-166 Transverse Offset Method FOTP-167 Mode Field Diameter Measurement, Variable Apeiture Method in Far-Field FOTP-168 Chromatic Dispersion Measurement of Multimode Graded- Index and Single-mode Optical Fiber by Phase-Shift Method

FOTP-169 Chromatic Dispersion Measurement of Optical Fibers by the Phase-Shift Method FOTP-170 Cable Cutoff Wavelength of Single-mode Fiber by Transmitted Power FOTP- 171 Attenuation by Substitution Measurement (Short Length Multimode Graded-Index and Single-mode) FOTP- 172 Flame Resistance of Firewall Connector FOTP- 173 Coating Geometry Measurement of Optical Fiber, Side-View Method FOTP- 174 Mode Field Diameter of Single-mode Fiber by Knife-Edge Scanning in Far-Field FOTP- 175 Chromatic Dispersion Measurement of Optical Fiber by the Differential Phase-Shift FOTP- 177 Numerical Aperture Measurement of Graded-Index Fiber FOTP- 178 Coating Strip Force Measurement FOTP- 179 Inspection of Cleaved Fiber End Faces by Interferometer FOTP- 180 Measurement of Optical Transfer Coefficients of a Passive Branching Device FOTP- 184 Coupling Proof Overload Test for Fiber Optic Interconnecting Devices FOTP- 185 Strength of Coupling Mechanism for Fiber Optic Interconnecting Devices FOTP- 186 Gauge Retention Force Measurement for Components FOTP- 187Engagement and Separation/Force for Connector Sets FOTP- 188 Low-Temperature Testing for Components FOTP- 189 Ozone Exposure Test for Components FOTP- 190 Low Air Pressure (High Altitude) Test for Components FOTP-191 - Measurement of Mode Field Diameter of Single-Mode Optical Fiber FOTP-193 - Polarization Crosstalk Method For Polarization Maintaining Optical Fiber And Components FOTP-195 - Coating Geometry Measurement For Optical Fiber FOTP-196 - Guideline For Polarization-Mode Measurement In Single Mode Fiber Optic Components And Devices FOTP-197 Differential Group Delay Measurement Of Single-Mode Components And Devices By The Differential Phase Shift Method FOTP-200 Insertion Loss Of Connector zed Polarization-Maintaining Fiber Or Polarizing Fiber Pigtailed Devices And Cable Assemblies FOTP-201 Return Loss Of Connector zed Polarization-Maintaining Fiber Or Polarizing Fiber Pigtailed Devices And Cable Assemblies FOTP- 203 {Transceiver output pattern} FOTP- 204 {Restricted Modal Launch Bandwidth for Multimode Fibers} FOTP- 220 {Differential Modal Dispersion in Multimode Fiber - Pulse Broadening As A Function of Source Launch Offsets} EIA-472 General Specification for Fiber Optic Cable EIA-472A Sectional Specification for Fiber Optic Communication Cables for Outside Aerial Use

EIA-472B Sectional Specification for Fiber Optic Communication Cables for Underground and Buried Use EIA-472C Sectional Specification for Fiber Optic Communication Cables for Indoor Use EIA-472D Sectional Specification for Fiber Optic Communication Cables for Outside Telephone Plant Use EIA-4750000-B Generic Specification for Fiber Optic Connectors EIA-475COOO Sectional Specification for Type FSMA Connectors EIA-475CAOO Blank Detail Specification for Optical Fiber and Cable Type FSMA, Environmental Category I EIA-475CBOO Blank Detail Specification Connector Set for Optical Fiber and Cables Type FSMA, Environmental Category 11 EIA-475CCOO Blank Detail Specification Connector Set for Optical Fiber and Cables Type FSMA, Environmental Category III EIA-475EOOO Sectional Specification for Fiber Optic Connectors Type BFOC/2.5 EIA-475EAOO Blank Detail Specification for Connector Set for Optical Fiber and Cables, Type BFOC/2.5, Environmental Category I EIA-475EBOO Blank Detail Specification for Connector Set for Optical Fiber and Cables, Type BFOC/2.5, Environmental Category 11 EIA-475ECOO Blank Detail Specification for Connector Set for Optical Fiber and Cables, Type BFOC/2.5, Environmental Category III EIA-492AAAA Detail Specification for 62.5 micron Core Diameter/I 25 micron Cladding Diameter Class I A Multii-node, Graded Index Optical EIA-5390000 Generic Specification for Field Portable Polishing Device for Preparation Optical Fiber EIA-5460000 Generic Specification for a Field Portable Optical Inspection Device, Combined EIA-NECQ Specification EIA-546A000 Sectional Specification for a Field Portable Optical Microscope for Inspection of Optical Waveguide and Related Devices EIA-587 Fiber Optic Graphic Symbols EIA-590 Standard for Physical Location and Protection of Below-Ground Fiber Optic Cable Plant EIA-598 Color Coding of Fiber Optic Cables WWW.MEFC.COM