IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Similar documents
Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS 476: Part 6: 1989+A1:2009

BS EN : 2001 & IEC :2000

BS 476: Part 6: 1989+A1:2009

BS EN ISO : 2010

BS EN ISO : 2010

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BS EN ISO : 2010

NF X : Parts 1, 2, 3, 4 & 5

Review Fire Test Report

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

IMO Resolution MSC 61(67): Annex 1: Part 2

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

25 th November Title:

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Fire Test Reports for Interpon D Powder Coatings

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

Test Report No: ICL/H17/7967

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

CERTIFICATE OF APPROVAL No ME 5085

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Exova Warringtonfire - Expert Witness Directory 2018

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ENHANCED FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

Test Report: ICL/CR15/11/087

Catalogue Telecommunication Cables INTRODUCCIÓN

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA

LSOH Flexible Cables

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

Fire Resistant Cables

INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Testing coated fabrics

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

LV FIRE RESISTANT CABLES

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

ISO INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

Overhead Line Insulators

Telecommunication Cables

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

ISO 3733 INTERNATIONAL STANDARD. Petroleum products and bituminous materials Determination of water Distillation method

ISO INTERNATIONAL STANDARD

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

Catalogue Power Cables

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

INTERNATIONAL STANDARD

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

CERTIFICATE OF APPROVAL No CF 136

Test Report: ICL/H18/9039 Rev 1

High Performance LSZH Fire Resistant Cable

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

INTERNATIONAL STANDARD

Traction Cable Radox 3 GKW

ISO 5657 INTERNATIONAL STANDARD. Reaction to fire tests Ignitability of building products using a radiant heat source

INTERNATIONAL STANDARD

AS/NZS IEC :2015

FIRE RESISTANT CABLES FP400

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion

STANDARDS INSTALLATION. Certificate No 077m

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

DNVGL-CP-0401 Edition February 2016

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

INTERNATIONAL STANDARD

DNVGL-CP-0399 Edition March 2016

ISO INTERNATIONAL STANDARD

Transcription:

Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IEC 60331-11-21 Method of test defined in IEC 60331-11 / -21 for determining the circuit integrity of electric cables under fire conditions A Report To: Arabian Vermiculite Industries Date: 17 th September 2010 Issue No.: 1 Page 1 Document Reference: Additional test report No. 196979 Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429 This report in issued in accordance with our terms and conditions, a copy of which is available on request.

Executive Summary Objective To determine the performance of the following coated cable when it is subjected to the conditions of test specified in IEC 60331-21: 1999, utilising the test apparatus detailed in IEC 60331-11:1999 + A1: 2009. Generic Description Thickness / Weight per unit diameter area or density Coated cable Avicoat Cable 24mm Not stated Individual components used to manufacture composite: Ablative coating Avicoat Cable 3mm Not stated Copper conductor Not Stated 1.5mm Not Stated XLPE Conductor Insulation Not Stated 1.0mm Not Stated PVC inner sheath Not Stated 3.0mm Not Stated Galvanised steel armour Not Stated 1.2mm Not Stated PVC outer sheath Not Stated 1.2mm Not Stated Please see page 5 of this test report for the full description of the product tested Test Sponsor Arabian Vermiculite Industries, 1 st Dammam Industrial Area, P.O. Box 7137, Dammam 31462, Kingdom of Saudi Arabia Test Results: When tested in accordance with the procedures specified in IEC 60331-21: 1999, utilising the test apparatus detailed in IEC 60331-11: 1999 + A1: 2009, at a temperature of at least 750 C and at a rated voltage of 1000 V-rms, the coated cables maintained their circuit integrity for a duration of 24 minutes 35 seconds for specimen 1 and 23 minutes 42 seconds for specimen 2. Date of Test 25 th August 2010 This test report is additional to that issued as WF No. 196059 dated 7 th September 2010 and has been issued at the request of the sponsor. The original test report remains valid and is not replaced by this additional test report. The product referred to in the original report and this additional test report has not been re-tested since the original test and neither has a technical review of the original test report resulting in any technical changes been carried out. The name and address details of the original sponsor have been removed and the details of Arabian Vermiculite Industries have been entered. The original product reference of the coating has been removed and the reference Avicoat Cable has been inserted. The name of the manufacturer of the coating has been removed for confidentiality purposes. The sponsor of the test has stated that the material described in this additional report is identical to the material which was tested. Both the original and the alternative name and address details and the original and alternative product references have been documented and the documentation is maintained in the confidential file covering this investigation. Signatories Responsible Officer S. Deeming * Senior Technical Officer * For and on behalf of Exova Warringtonfire. Report Issued: 17 th September 2010 Authorised C. Dean * Operations Manager P.P. D.J. Owen This version of the report has been produced from a.pdf format electronic file that has been provided by Exova Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Exova Warringtonfire. Document No.: Additional test report No. 196979 Page No.: 2 of 8

CONTENTS PAGE NO. EXECUTIVE SUMMARY... 2 SIGNATORIES... 2 TEST DETAILS... 4 DESCRIPTION OF TEST SPECIMENS...5 TEST RESULTS... 7 REVISION HISTORY... 8 Document No.: Additional test report No. 196979 Page No.: 3 of 8

Test Details Purpose of test Scope of test To determine the performance of a specimen of a cable when it is subjected to the conditions of test specified in IEC 60331-21: 1999, utilising the test apparatus detailed in IEC 60331-11:1999 + A1: 2009. The purpose of this test method is to determine whether a cable can maintain circuit integrity when it is exposed to the fire conditions described within the method. IEC 60331-21: 1999 specifies a test procedure and gives a performance requirement, including a recommended flame application time, for cables of rated voltage up to and including 600/1000 V. It is intended to cover low voltage power cables and control cables with a rated voltage. In accordance with section 7.1 of the test standard, a 90 minute flame application time was used. At the specific request of the original sponsor of the test, two specimens of coated cable were tested. IEC 60331-11: 1999 + A1: 2009 specifies the test apparatus to be used for testing cables required to maintain circuit integrity when subject to fire alone where the test condition is based upon a flame with a controlled heat output corresponding to a temperature of at least 750 C. Fire test study group/egolf Instruction to test Provision of test specimens Certain aspects of some fire test specifications are open to different interpretations. The Fire Test Study Group and EGOLF have identified a number of such areas and have agreed Resolutions which define common agreement of interpretations between fire test laboratories which are members of the Groups. Where such Resolutions are applicable to this test they have been followed. The test was conducted on the 25 th August 2010 at the request of the original sponsor of the test. The specimens were supplied by the original sponsor of the test. Exova Warringtonfire was not involved in any selection or sampling procedure. The specimens were received on the 6 th August 2010. Burner verification procedure The verification procedure for the burner was conducted in accordance with Annex A of IEC 60331-11: 1999 + A1: 2009 at the start of the test day. This determined the gas & air flow rates and the position of the burner that were used for the subsequent cable tests. Document No.: Additional test report No. 196979 Page No.: 4 of 8

Description of Test Specimens The description of the specimens given below has been prepared from information provided by the original sponsor of the test. All values quoted are nominal, unless tolerances are given. General description Flexible ablative coating applied to cable (coated cable) Avicoat Cable Overall diameter (coated cable) 24mm (stated by original sponsor) 25mm (determined by Exova Warringtonfire) Overall weight per unit length (coated cable) Ablative coating Avicoat Cable Detailed description / See Note 2 Below composition details See Note 3 Below Coating Colour White Number of coats 1 Application thickness per coat 3mm Application method Brush Flame retardant details See Note 2 Below Curing process per coat Drying at room temperature for 2 weeks. CU/XLPE/SWA/PVC Cable markings ELECTRIC CABLE 600/1000V BS 5467 (DRAKA UK) BASEC MADE IN UK Cable function Power cable for residential or industrial areas Number of cores 3 Voltage rating 600/1000 V Cable manufacturer Nexans Copper Total cross-sectional area of 3.142 x 3 2 = 28.28mm 2 Conductors each conductor Diameter of each strand 1.5mm Weight per unit length per strand Number of strands per 7 conductor XLPE Conductor Colour Brown, Black, Grey Insulation Thickness 1mm Density / weight per unit area Flame retardant details See Note 4 Below Cable Continued on next page Document No.: Additional test report No. 196979 Page No.: 5 of 8

Cable (continued) Inner sheath Armour Outer sheath PVC Colour Black Thickness 3mm Density / weight per unit area Flame retardant details See Note 4 Below Single layer galvanised round steel wire Diameter of each strand 1.2mm Weight per unit length of each strand Number of strands 34 PVC Colour Black Thickness 1.2mm Density / weight per unit area Flame retardant details See Note 4 Below Coating is brush applied to the cable at the desired thickness. The original sponsor was unwilling to provide further information relating to the manufacturing process of the coating and was unable to provide information relating to the manufacturing process of the cable Brief description of manufacturing process of coating / cable Note 1 - The original sponsor was unable to provide this information. Note 2 - The original sponsor was unwilling to provide this information. Note 3 - The original sponsor of the test has provided this information but at the specific request of the sponsor, these details have been omitted from the report and are instead held on the confidential file relating to this investigation. Note 4 - The original sponsor of the test has confirmed that no flame retardant additives were utilised in the production of the product / component. The original sponsor has confirmed that the cable specimen was manufactured by another party and that they were not able to obtain from the manufacturer some details that would normally be included in Exova Warringtonfire test reports. The description of the specimen given above is therefore not as complete as would normally be the case for descriptions included in Exova Warringtonfire test reports and the description may not fully comply with the requirements of the test standard. In all other respects however the test was conducted fully in accordance with the requirements of the test standard and the test results are valid. Document No.: Additional test report No. 196979 Page No.: 6 of 8

Test Results Applicability of test result The test results relate only to the specimen of the cable in the form in which it was tested. Small differences in the composition of the product may significantly affect the performance during the test and may therefore invalidate the test results. Care should be taken to ensure that any product, which is supplied or used, is fully represented by the specimen, which was tested. Results of test When tested in accordance with the procedures specified in IEC 60331-21: 1999, utilising the test apparatus detailed in IEC 60331-11: 1999 + A1: 2009, at a temperature of at least 750 C and at a rated voltage of 1000 V-rms, the coated cables maintained their circuit integrity for a duration of 24 minutes 35 seconds for specimen 1 and 23 minutes 42 seconds for specimen 2. Validity The specification and interpretation of fire test methods are the subject of ongoing development and refinement. Changes in associated legislation may also occur. For these reasons it is recommended that the relevance of test reports over five years old should be considered by the user. The laboratory that issued the report will be able to offer, on behalf of the legal owner, a review of the procedures adopted for a particular test to ensure that they are consistent with current practices, and if required may endorse the test report. This report may only be reproduced in full. Extracts or abridgements shall not be published without permission of Exova Warringtonfire. Document No.: Additional test report No. 196979 Page No.: 7 of 8

Revision History Issue No : Revised By: Reason for Revision: Issue Date: Approved By: Issue No : Revised By: Reason for Revision: Issue Date: Approved By: Document No.: Additional test report No. 196979 Page No.: 8 of 8