GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Similar documents
outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Ø 1000 * 588 mm 50 kg

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Duct Cable GYTS-144B1.3

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

HELKAMA. Optical Fibre Cables

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Fiber Optic Distribution Cables (6-144 Fibers)

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

SPECIAL ELECTRICAL AND OPTICAL CABLES

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Fibre Optic Cable. Catalogue.

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Special Provision No. 683S28 December 2017

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

DNVGL-CP-0402 Edition February 2016

industry solutions: military

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Fibre Specification Standards

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

High Performance LSZH Fire Resistant Cable

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

fire resistant cables

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Caledonian Flame Retardant Coaxial Cables

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Fibre optic media options and trends

FIRE RESISTANT CABLES

Traction Cable Radox 3 GKW

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Caledonian Fire resistant Coaxial Cables

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

Connectors for Optic Fibre Cable

Fiber Optic Patch Cord and Pigtails

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Catalogue Telecommunication Cables INTRODUCCIÓN

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

ENHANCED FIRE PERFORMANCE CABLE

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

PRODUCT CATALOGUE Norröna

The Quality Connection. Cable fire protection Flammability tests on ship and offshore cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

The Quality Connection. BETAflam Fire Resistant Safety Cables

Comtran Cable. Hub-LINK Cables for Transit Applications

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Dome Fiber Optic Closure SC-221

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

DNVGL-CP-0401 Edition February 2016

Catalogue. Instrumentation & Control Cables

Detection of Solvents using a Distributed Fibre Optic Sensor

Introduction.

Installation Considerations for Pipelines

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Main features of the JETnet system

Total Fire Solutions. Includes BS 8519 and the updated BS :

Havells Fire Survival Cables

Tratos Railway Cables

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

FIRE RESISTANT CABLES FP400

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OIL & GAS INDUSTRY OTHER INDUSTRIES

FIRE PERFORMANCE CABLE

Single core cables with reduced wall thickness

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Telecommunication Cables

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Üntel is ready for CPR

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Fibre Optic Basics FIA Summer Seminar 2014

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

DNVGL-CP-0399 Edition March 2016

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Catalogue Power Cables

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

Transcription:

GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM GUCN0 GUCN04 GUCN06 GUCN08 GUCN GUCN6 GUCN4 50/5-OM BI GUCN0 GUCN04 GUCN06 GUCN08 GUCN GUCN6 GUCN4 50/5-OM3 BI GUCND0 GUCND04 GUCND06 GUCND08 GUCND GUCND6 GUCND4 50/5-OM4 BI GUCNE0 GUCNE04 GUCNE06 GUCNE08 GUCNE GUCNE6 GUCNE4 ITU G.655 C&D GUCN70 GUCN704 GUCN706 GUCN708 GUCN7 GUCN76 GUCN74 ITU G.65D & G.657A BI GUCN80 GUCN804 GUCN806 GUCN808 GUCN8 GUCN86 GUCN84 ITU G.657A BI GUCNF0 GUCNF04 GUCNF06 GUCNF08 GUCNF GUCNF6 GUCNF4 ITU G.657B3 BI GUCNI0 GUCNI04 GUCNI06 GUCNI08 GUCNI GUCNI6 GUCNI4 Std. plywood reel (non-returnable) Ø 000 * 588 mm 8 kg Std. delivery length 00 ± 05m Applications For outdoor and indoor use in structured (data) wiring systems such as (campus backbone). For outdoor and indoor use in networks for telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches. Suitable for direct burial. Features & Benefits A simple cable construction and consequently more cost-effective up to 4 fibres then multi-tube cables. High mechanical and full rodent protection provided by corrugated steel tape (CST) armour. Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794). Primary coated optical fibres: Ø 50 ± 5 um.. Central tube, jelly filled (non-dripping and silicon-free) with up to 4 fibres. Individually colour coded optical fibres: : red natural yellow blue green violet brown black orange - turquoise pink and white. 3 4: red natural yellow blue green violet brown grey orange turquoise pink and white with rings. 3. Water swellable E-glass yarns as strength members and for the longitudinal watertightness, surrounded by swelling tape. 4. Corrugated Steel Tape Armouring (CST): longitudinally applied steel tape (0.55 mm). 5. Black UV resistant FRNC/LSNH outer jacket. Identification: BELDEN OFC cable type number x fibre type + date-, meter- and marking. Mechanical Data No. of fibres Max. 4 Ø Central tube (mm) 3.3 Ø nom./max. (mm) 9.0/9.3 Energy of flame (kj/m) 045 Weight (kg/km) 03

Optical Characteristics Characteristics Single-Mode Matched-Cladded optical fibres according to ITU. Fibre-Type Mode-Field /Cladding Diameter (um) Attenuation B typical/ max. (db/km) Dispersion (ps/(nm-km) PMD A (ps/km) Cable Cut-off 7 G.655 C&D 8.4 ± 0.6 5 ± 0.7 0. / 0. 0. / 0.4 4.5 7.9 < 0.04 60 8 G.65D & G.657A BI OS 9. ± 0.4 5 ± 0.7 30 0.33 / 0.34 0.8 / 0.9 0.0 / 0.4 3. 7 0.06 60 F G.657A BI 8.9 ± 0.4 4.8 ± 0.3 30 0.34 / 0.35 0.9 / 0. 0.0 / 0.4 3.5 8 0. 60 I G.657B3 BI 8.8 ± 0.4 5 ± 0.4 30 0.34 / 0.35 0.9 / 0. 0.0 / 0.3 3.5 8 0.06 60 Note A- Link design value Note B- Due to cabling the optical attenuation values can increase with max. 0.05 db/km Characteristics Multi-Mode Graded-Index optical fibres according to IEC 60793 Fibre- Type Core/ Cladding Diameter (um) Attenuation C typical/ max. (db/km) Bandwidth (MHzkm) Ethernet Performance (m) GBE 0 GBE Num. Apert. (µm) 6.5/5 OM 50/5 OM BI 6.5 ±.5 5 ± 50 ±.5 5 ±.7 / 3.0 0.7 / 0.8.3 /.5 / 0.6 00 600 0 600 600 33 83 0.75 ± 0.05 0.0 ± 0.05 D 50/5 OM3 BI 50 ±.5 5 ±.3 /.5 / 0.6 000 0.0 ± 0.05 E 50/5 OM4 BI 50 ±.5 5 ±.3 /.5 / 0.6 3500 00 0.0 ± 0.05 Note C- Due to cabling the optical attenuation values can increase with max. 0.4 db/km 3

Macro Bending Performance Fibers Maximum attenuation increase for Bend Insensitive Single Mode fibers in db depending on turns and radius. 7 Fibre-Type G.655 C & D 00 30 mm 0.05 0.05 0 5 mm 6 mm 0 mm 7.5 mm ) 5 mm 8 G.65D & G.657A BI OS 0.5.0 0.75.5 F G.657A BI 0. 0. 0..0 I G.657B3 BI 0. 0.08 0.5 0.5 0.45 Maximum attenuation increase for Bend Insensitive Multi Mode fibers in db depending on turns and radius. Fibre-Type 6.5/5 OM 00 37.5 mm 5 mm ) 7.5 mm 50/5 OM BI 0. 0.3 0. D 50/5 OM3 BI 0. 0.3 0. E 50/5 OM4 BI 0. 0.3 0. 4

Mechanical, Physical and/or Environmental Characteristics Description: Tested according to: Requirement: According to Family specification: Storage Temperature Range IEC 60794---F -30 to +70 C IEC 60794-3-0 Installation Temperature Range -5 to +40 C Operating Temperature Range -30 to +70 C Bending Tube (Installation and Operation) > 5 mm Cable Water Blocking IEC 60794---F5 Pass Cable Min. Bend Operation (Long Term) IEC 60794---E 0 x Cable Diam. IEC 60794-3-0 Cable Min. Bend Installation (Short Term) IEC 60794---E6 0 x Cable Diam. Cable Max. Tensile Strength Operation (Long Term) IEC 60794---E 740 N IEC 60794-3-0 Cable Max. Tensile Strength Installation (Short Term) Cable Max. Crush Resistance Operation (Long Term) Cable Max. Crush Resistance Installation (Short Term) IEC 60794---E3 0 N kn/m kn/m IEC 60794-3-0 Safety Testing standard Reaction to fire IEC 6033- IEC 6033-3- EN 50575 Description / Value Cca-s,d,a Circuit Integrity IEC 6033-5 E0: duration of test 0 minutes PH0: duration of test 0 minutes including EN 5000 shocks Toxicity NF X 70-00- Smoke density IEC 6034- Halogen acid gas content IEC 60754- Zero Degree of acidity of gases IEC 60754- Min. 4.3 ph IEC 60754- Max. 0 µs/mm 5

Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Cables for outdoor use only. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 6