Shipboard & Offshore Cables

Similar documents
Telecommunication Cables

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue. Instrumentation & Control Cables

Catalogue Power Cables

PRODUCT CATALOGUE Norröna

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Flame Retardant Overall Screened Instrumentation Cables (multicore)

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Caledonian Flame Retardant Coaxial Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Caledonian fire Resistant signal & Data cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Lloyd s Register Type Approval System Test Specification Number 3

DNVGL-CP-0401 Edition February 2016

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

DNVGL-CP-0399 Edition March 2016

FIRE RESISTANT CABLES

OIL & GAS INDUSTRY OTHER INDUSTRIES

High Performance LSZH Fire Resistant Cable

Caledonian Fire resistant Coaxial Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

TYPE APPROVAL CERTIFICATE

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Havells Fire Survival Cables

INTERNATIONAL STANDARD

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

DNVGL-CP-0402 Edition February 2016

Caledonian. FIREFLIX ire Resistant Coaxial Cables

SAS Security and Alarm Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables

Fire Resistant Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

BS /1000V XLPE Insulation LSZH Sheath Cables

INTERNATIONAL STANDARD

CABLES FOR ALARM AND SAFETY SYSTEMS

Cablosam Tapes for Fire-Resistant Cables

INTERNATIONAL STANDARD

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Low Smoke Zero Halogen

fire resistant cables

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Firecel Safety Cables

Evolution of Cable Fire Safety Standards in Australia

Custom-designed and standard Multiconductor (Multicore) Cables

UNIKA Universal Cable Cable Specialist

Total Fire Solutions. Includes BS 8519 and the updated BS :

THE TRUE FIRE SURVIVAL CABLE

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

(Notices) EUROPEAN COMMISSION

Compact Module. Category 6A FTP Cabling System 1.1

Sensor and transducer cables

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

Multi-Core Fire Resistant Cable

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

SPECIAL ELECTRICAL AND OPTICAL CABLES

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Tratos Railway Cables

Cable technology for highest safety requirements

SOLAR CABLES. Electric cables for solar PV installations

FIRE PERFORMANCE CABLE

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

ENHANCED FIRE PERFORMANCE CABLE

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

QUALITY THROUGH EXPERIENCE

Traction Cable Radox 3 GKW

Nuclear Power Plant LSZH Cable Overview

Photovoltaic Cables EN H1Z2Z2-K

FIRE RESISTANT CABLES FP300

Introduction.

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CONNECTION SYSTEMS TRANSIT APPLICATIONS

REACTION TO FIRE OF CABLE SYSTEMS. G. DENCHE* N. GENERÓ O. RODRIGUEZ Red Eléctrica de España S.A.U. Grupo General Cable Sistemas

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

IEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Wire and Cable The Industry Standard for Rugged, Reliable Performance

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

WHITE PAPER: IBS & IBSB ADVANCED

Power Control Cable Iec

PERFORMANCE POLYMER SOLUTIONS

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES

FIRE RESISTANT CABLES FP400

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

STANDARDS INSTALLATION. Certificate No 077m

PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. COMPANY PROFILE 2015

Transcription:

Shipboard & Offshore Cables

Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR 10 XOLC4L / XOLC4L-FR 11 elecwires 2 www.elecwires.es

INTRODUCTION Shipboard & Offshore Cables The cables used in the Shipboard & Offshore industries are used for signalling, control and security applications. All our cables comply with the most demanding international and/or military standards and are inspected by recognized certification entities such as; Det Norske Veritas, Lloyd's Register or Bureau Veritas. Because of the special environment conditions, applications and uses, these cables are manufactured fire retardant, as well as halogen free and low smoke emission (LSZH, Low Smoke Zero These cables can also be provided with the optional feature of fire resistant. There are many different options to design the most suitable cable for each application. As an indication, the most commonly used configurations are: Power Cables 0,6/1 kv: XL / XL-FR*. Unscreened Cables XC4L / XC4L-FR*. Braided Copper Armour Cables XLC4L / XLC4L-FR*. Braided Copper Armour and Inner Sheath Cables Instrumentación cables 250 V: XHL / XHL-FR*. Cables with Individual Screened Pairs XOL / XOL-FR*. Cables with Overall Screened Pairs XHC4L / XHC4L-FR*. Cables with Braided Copper Armour and Individual Screened Pairs XOLC4L / XOLC4L-FR*. Cables with Braided Copper Armour, Inner Sheath and Overall Screened Pairs Option FR*. Fire resistant feature Sheaths. These cables can be manufactured either with SHF1 Sheaths (thermoplastic LSZH, Low Smoke Zero Halogen) or SHF2 Sheaths (cross linked thermostable LSZH, Low Smoke Zero elecwires 3 www.elecwires.es

Depending on the application, these cables can be manufactured under standard IEC 60092 Electrical Installations in Ships: Electrical installations in ships. Cables (construction, testing and installations). IEC 60092-3 (UNE 21135-3) Shipboard power cables. General construction and test requirements. IEC 60092-350 (UNE-EN 21135-350) Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables. IEC 60092-351 (UNE-IEC 60092-351) Cables for control and instrumentation circuits 150/250 V (300 V). IEC 60092-376 According to cable behaviour against fire, the above mentioned configurations can be manufactured: Fire resistant. IEC 60331, UNE-EN 50200 & UNE-EN 50362. IEC 60332-3 Cat. C & -3-24 Cat. C. (-1-1) & IEC 60332-2 (UNE- EN 60332-1-2) Low Smoke Emission. (UNE-EN 61034) Halogen free. () Además se pueden fabricar según las siguientes normas: Resistente al fuego. IEC 60331, UNE-EN 50200 y UNE-EN 50362 OPTIONS & ALTERNATIVES Different types of cable features can be provided: Hydrocarbon and mineral oil resistant. UNE-EN 60811-2-1 & UIC 895 OR Configurations with different types of armours and materials elecwires 4 www.elecwires.es

SHIPBOARD & OFFSHORE CABLES - POWER XL / XL-FR* 0,6/1 kv Sections: 0,5 a 400 mm 2. *OPTION FR, Optional mica layer or mineral insulation for fire resistant performance. Cabled in concentric layers. Outer Sheath SHF1 (thermoplastic LSZH, Low Smoke Zero thermostable LSZH, Low Smoke Zero *OPTIONS (others available under request) Sheaths SHF1 & SHF2 APLICATION Y PROPERTIES: Multi-conductor cables installed in power systems for shipboards and off-shore platforms with special features against fire; fire retardant, low emission of dark fumes and corrosive and toxic gases. Cables with high flexibility which provides good performance against vibrations and easy installation features. IEC 60228 (UNE-EN 60228) IEC 60092-350 y UNE-EN 21135-350 IEC 60092-351 y UNE-EN 21135-351 IEC 60092-359 y UNE-EN 21135-359 elecwires 5 www.elecwires.es

SHIPBOARD & OFFSHORE CABLES - POWER XC4L / XC4L-FR* 0,6/1 kv Sections: 0.5 to 400 mm 2. *OPTION FR, Optional mica layer or mineral insulation for fire resistant performance. Cabled in concentric layers. Separator Polyester tape. Overall Screen Copper wire braid. Outer Sheath thermostable LSZH, Low Smoke Zero *OPTIONS (others available under request) Sheaths SHF1 & SHF2 APLICATION & PROPERTIES: Multi-conductor cables installed in power systems for shipboards and off-shore platforms with special features against fire; fire retardant, low emission of dark fumes and corrosive and toxic gases. The Cooper wire braid screen provides the cable with mechanical and electromagnetic protection against undesired interferences. Cables with high flexibility which provides good performance against vibrations and easy installation features. IEC 60092-350 IEC 60092-351 IEC 60092-359 UNE-EN 61034 elecwires 6 www.elecwires.es

SHIPBOARD & OFFSHORE CABLES - POWER XLC4L / XLC4L-FR* 0,6/1 kv Sections: 0.5 to 400 mm 2. *OPTION FR, Optional mica layer or mineral insulation for fire resistant performance. Cabled in concentric layers. Separator Polyester tape. Inner Sheath thermostable LSZH, Low Smoke Zero Overall Screen Copper wire braid. Outer Sheath thermostable LSZH, Low Smoke Zero *OPTIONS (others available under request) Sheaths SHF1 & SHF2 APLICATION & PROPERTIES: Multi-conductor cables installed in power systems for shipboards and off-shore platforms with special features against fire; fire retardant, low emission of dark fumes and corrosive and toxic gases. The Cooper wire braid screen provides the cable with mechanical and electromagnetic protection against undesired interferences. Cables with high flexibility which provides good performance against vibrations and easy installation features. IEC 60092-350 IEC 60092-351 IEC 60092-359 UNE-EN 61034 elecwires 7 www.elecwires.es

SHIPBOARD & OFFSHORE CABLES - INSTRUMENTATION XHL / XHL-FR* 150/250V Sections: 0.5 to 400 mm 2. *OPTION FR, Optional mica layer or mineral insulation for fire resistant performance. Pairs. Groups are cabled in concentric layers to build the cable core. Individual Screen Aluminium-polyester tape. Separator Polyester tape. Outer Sheath thermostable LSZH, Low Smoke Zero *OPTIONS (others available under request) Sheaths SHF1 & SHF2 APLICACTION & PROPERTIES: Instrumentation cables installed in control systems for shipboards and off-shore platforms with special features against fire; fire retardant, low emission of dark fumes and corrosive and toxic gases. The screen provides the cable electromagnetic protection against undesired interferences. Cables with high flexibility which provides good performance against vibrations and easy installation features. IEC 60092-350 IEC 60092-351 IEC 60092-359 UNE-EN 61034 elecwires 8 www.elecwires.es

SHIPBOARD & OFFSHORE CABLES - INSTRUMENTATION XOL / XOL-FR* 150/250V Sections: 0.5 to 400 mm 2. *OPTION FR, Optional mica layer or mineral insulation for fire resistant performance. Pairs. Groups are cabled in concentric layers to build the cable core. Overall Screen Copolymer-aluminium- copolymer. Outer Sheath thermostable LSZH, Low Smoke Zero *OPTIONS (others available under request) Sheaths SHF1 & SHF2 APLICATION & PROPERTIES: Instrumentation cables installed in control systems for shipboards and off-shore platforms with special features against fire; fire retardant, low emission of dark fumes and corrosive and toxic gases. The screen provides the cable electromagnetic protection against undesired interferences. Cables with high flexibility which provides good performance against vibrations and easy installation features. IEC 60092-350 IEC 60092-351 IEC 60092-359 UNE-EN 61034 elecwires 9 www.elecwires.es

SHIPBOARD & OFFSHORE CABLES - POWER XHC4L / XHC4L-FR* 150/250V Sections: 0.5 to 400 mm 2. *OPTION FR, Optional mica layer or mineral insulation for fire resistant performance. Cabled in concentric layers. Separator Polyester tape. Inner Sheath thermostable LSZH, Low Smoke Zero Overall Screen Copper wire braid. Outer Sheath *OPTION,SHF2 (cross linked LSZH thermostable, Low Smoke Zero *OPCIONES (others available under request) Cubiertas SHF1 y SHF2 APLICATION & PROPERTIES: Multi-conductor cables installed in power systems for shipboards and off-shore platforms with special features against fire; fire retardant, low emission of dark fumes and corrosive and toxic gases. The Cooper wire braid screen provides the cable with mechanical and electromagnetic protection against undesired interferences. Cables with high flexibility which provides good performance against vibrations and easy installation features. IEC 60092-350 IEC 60092-351 IEC 60092-359 UNE-EN 61034 elecwires 10 www.elecwires.es

SHIPBOARD & OFFSHORE CABLES - POWER XHC4L / XHC4L-FR* 150/250V Sections: 0.5 to 400 mm 2. *OPTION FR, Optional mica layer or mineral insulation for fire resistant performance. Pairs. Groups are cabled in concentric layers to build the cable core. Overall Screen Polyester-Aluminium-polyester tape. Separator Polyester tape. Inner Sheath thermostable LSZH, Low Smoke Zero Overall Screen Copper wire braid. Inner Sheath thermostable LSZH, Low Smoke Zero *OPTIONS (others available under request) Sheaths SHF1 y SHF2 APLICATION & PROPERTIES: Instrumentation cables installed in control systems for shipboards and off-shore platforms with special features against fire; fire retardant, low emission of dark fumes and corrosive and toxic gases. The overall screens provide the cable with mechanical and electromagnetic protection against undesired interferences. Cables with high flexibility which provides good performance against vibrations and easy installation features. IEC 60092-350 IEC 60092-351 IEC 60092-359 UNE-EN 61034 elecwires 11 www.elecwires.es

C/ Olmo 10-12 Polígono Industrial Malpica-Alfindén 50.171 La Puebla de Alfindén Zaragoza España-Spain-Espagne Tel: +34 976 11 50 17 Email : info@elecwires.es elecwires 12 www.elecwires.es