THE TRUE FIRE SURVIVAL CABLE

Similar documents
High Performance LSZH Fire Resistant Cable

fire resistant cables

Havells Fire Survival Cables

Total Fire Solutions. Includes BS 8519 and the updated BS :

Fire Resistant Cables

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

FIRE RESISTANT CABLES FP400

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

The Quality Connection. BETAflam Fire Resistant Safety Cables

Lloyd s Register Type Approval System Test Specification Number 3

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Introduction.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

DNVGL-CP-0401 Edition February 2016

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Cablosam Tapes for Fire-Resistant Cables

DNVGL-CP-0399 Edition March 2016

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

FIRE RESISTANT CABLES

Are Electric Cables my biggest Fire Risk?

Evolution of Cable Fire Safety Standards in Australia

FIRE RESISTANT CABLES FP300

BS /1000V XLPE Insulation LSZH Sheath Cables

WORLDWIDE CABLE EXPERTS

CABLE & HOSE PROTECTION PRODUCT OVERVIEW

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Catalogue. Instrumentation & Control Cables

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Catalogue Power Cables

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Nuclear Power Plant LSZH Cable Overview

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

Tratos Railway Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables

ENHANCED FIRE PERFORMANCE CABLE

Guide to the Specification and Installation of Pyro Mi Wiring Cables

Photovoltaic Cables EN H1Z2Z2-K

A guide. Part 1: Code of practice for system design, installation, commissioning and maintenance. by T.L. Journeaux

For Heavy Duty Commercial and Industrial Environments

Catalogue Telecommunication Cables INTRODUCCIÓN

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables

LV FIRE RESISTANT CABLES

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

FIRE PERFORMANCE CABLE

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

FIRE RESISTANT CABLES FP200 GOLD

Cable technology for highest safety requirements

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

Telecommunication Cables

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Traction Cable Radox 3 GKW

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

HRS Hand Rail System 1

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

DNVGL-CP-0402 Edition February 2016

FIRE RESISTANT CABLES FP200 GOLD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Üntel is ready for CPR

Product Data Sheet Trespa HPL Panels

NON ELECTRICAL LOW LEVEL GUIDANCE SYSTEMS EMERGENCY LIGHTING. Photoluminescent Low Level Wayguidance Systems - Overview

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

STANDARDS INSTALLATION. Certificate No 077m

(Notices) EUROPEAN COMMISSION

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

OIL & GAS INDUSTRY OTHER INDUSTRIES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Caledonian Flame Retardant Coaxial Cables

User Information Sheet 008 : 2010

General safety precautions English

INDUSTRIAL fire-rated wiring

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Transcription:

25 YEAR THE TRUE FIRE SURVIVAL CABLE WARRANTY

In 1989 we developed a unique process of manufacturing continuous mineral insulated copper cables.

THE TRUE FIRE SURVIVAL CABLE We are the only UK manufacturer of continuous Mineral Insulated Cables, exporting to over 20 countries globally including the Middle East, India, Australia and China. Back in 1989 we developed a unique process of manufacturing continuous mineral insulated copper cables. This process ensures 100% continuity and quality but more importantly makes our cable the only cable which can safely carry a load for 3 hours at 950 C and for short periods at temperatures in excess of 1000 C. Our cables are installed in some of the worlds largest and most important buildings and recognised throughout the electrical industry as the best choice for fire survival. The quality and reliability of our mineral insulated cables meet and exceed British, European and Australian standards and maintain certifications from BRE-LPCB, Warrington Fire Research Centre and London Underground with our termination glands approved by SIRA-ATEX EExd. Our cable consists of only two elements: Copper + Magnesium Oxide. Neither release toxins, neither will burn. Inorganic construction 4 NOTHING TO BURN NOTHING TO BURN 4 ZERO TOXIC emissions or smoke INORGANIC materials 4 LAST a LIFETIME Holistic Fire Survival 4 ZERO combustion or heat release Naturally armoured 4 NO risk of rodent damage SELF MONITORING 4 NO false ALARMS FURNACE TESTED 4 Passes the ONLY true life like fire test QUALITY SYSTEM ISO 9001:2008 CERTIFICATE NO: 333 CERTIFIED TO BS 60702-1.2002 REFERENCE NO: 333a/01 25 YEAR WARRANTY Warranty details available on our website: www.wrexhammineralcables.com

Why our cable is the only TRUE FIRE SURVIVAL CABLE Our cable consists of only two elements: Copper + Magnesium Oxide. Neither release toxins, neither will burn. In the UK, fire resistant cables must meet the following standards: British fire performance standards BS EN 50200 PH120 Enhanced demands 2 hours fire resistance at 850 C. BS 6387 category C, W & Z demands that cables perform safely for 3 hours at 950 C. All 3 tests performed using the same cable sample. Our cables exceed these requirements. Mineral Insulated Copper Cable (MICC) CABLE PROPERTY Copper MICC Cable LSF FP/FR Soft Skin Our cable is totally Inorganic and Silicone free. It consists of multiple copper conductors (cores), highly compressed magnesium oxide (insulation) and an outer copper sheath, thats just 2 elements. This unique composition has an outer melting point of 1083 C (the melting point of copper) and ultimately 2800 C for the insulation (magnesium oxide). Note that the internal load carrying cores are protected inside the magnesium oxide insulation. This allows our cable to safely carry a load in temperatures in excess of 1000 C making it a TRUE fire survival cable. Our MICC cable is water and oil resistant, can carry greater current ratings, require no conduit for mechanical or vermin protection, UV and radiation resistant and can last in excess of 50 years. Soft Skin Flame Retardant Polymer Cables In order to give soft skinned polymer cables flame retardant properties, halogens are added to the outer sheath such as; chlorine, bromine and fluorine. When exposed to a fire, these halogenated polymers will release halides which are extremely toxic. The outer and inner sheaths of soft skin polymer cables burn and contribute to a fire releasing toxic smoke which can itself ignite, often explosively. All the soft skin polymer cables we have tested fail after only 10 minutes which in a densely populated public building may not be enough time for everyone to escape. OVER 15min (egress time) YES NO 250 C operating temp YES NO 650 C operating temp YES NO Exposure to 1040 C YES NO BS6387 CWZ YES YES BS6387 CWZ Enhanced YES NO BS8491 Furnace test YES NO Flame retardant YES YES Waterproof, submersible YES NO NO SELF IGNITION YES NO Mechanical shock & pressure resistant YES NO Zero toxic emissions YES NO SELF MONITORING YES NO Non-aging, corrosion resistant YES NO Suitable for confined space / tunnel YES NO 100% recyclable YES NO NO CONDUIT REQUIRED YES NO High Overload resistance YES NO ZERO SMOKE on overload YES NO Gas bio/chemical proof YES NO RODENT PROOF YES NO

what is enough time? IN CASE OF EMERGENCY 1] Sound the alarm But if the wire is burnt and not connected how can you? 2] Dial 999, Inform reception/security Impossible if the communication wires are burnt. 3] Attack the fire with extinguishers But how can you if the lights are not working and you can t find them? 4] Follow exit signs You can t because plastic sheathing around the emergency systems cabling is emitting toxic smoke and you cannot see or breathe. 5] Contain the fire by closing windows & doors A bit difficult if you have NO lights and you cant see because of smoke. 10 minutes? 6] Use the exit stairwells? Fine, but you can t find them because emergency lights have failed and smoke extraction fans have stopped due to wires burnt. 5 All soft skin competitor fire resistant cables we ve tested fail after just 10 minutes when exposed to temperatures of 850 C. (This is the testing temperature of BS EN 50200 ph120 Enhanced) which requires 2 hours fire resistance. Soft skin cables also release toxic gases and in many cases add fuel to the fire - they burn! Competitor cable after just 10 minutes at 850 C or 3 hours? 5 Our MICC cable easily withstands temperatures exceeding 850 C for hours right up to the melting point of copper (1083 C) and its composition means there is NOTHING to burn! Our cable after 3 hours at 950 C

Manufacturing Process 20,000m per day Magnesium Oxide (MgO) powder is mixed with additives to create a puttylike compound. This compound is then extruded through our unique extrusion system to produce insulating rods. Any broken rods are recycled back through the system ensuring zero waste. Why Magnesium Oxide? 24 hour production These rods are relatively soft and flexible. We fire these rods in our purpose built kilns at temperatures in excess of 1100 C to remove all moisture and additives leaving a pure inorganic rod. MgO is a refractory material, a solid that is physically and chemically stable at high temperatures. Its two main attributes are high thermal conductivity and low electrical conductivity making it an ideal insulator for our cables. At this stage the copper conductors, insulation rods and outer copper sheath are combined together in one efficient process.

continuous manufacture By manually adding the insulation, the most vital part of our cables, we can monitor consistency and rectify any defects. The pre-formed cable is then seam fused using a Tig process before entering our rolling mills. During this process the cable is gradually reduced in diameter to the desired specification while passing through our high frequency induction annealer. competitive lead time

Approvals & Standards CERTIFIED TO BS 60702-1.2002 REFERENCE NO: 333a/01 QUALITY SYSTEM ISO 9001:2008 CERTIFICATE NO: 333 Approvals: MANUFACTURE & TESTING TO BS/IEC 60702-1:2002+A1:2015 CERTIFICATION OF ASSESSED QUALITY ASSURANCE NO. 333 TO BS EN ISO 9001 LPCB PRODUCT CERTIFICATION NO. 333a/01 APPROVAL BODY STANDARD REFERENCE DESCRIPTION LPCB IEC 60331-2 Test method for fire with shock at a temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kv and with an overall diameter not exceeding 20mm. LPCB IEC 60332-2 Tests on electric cables under fire conditions - Part 2-2: Test for vertical flame propagation. LPCB IEC 60754-1 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content. LPCB IEC 61034-2 Measurement of smoke density of cables burning under defined fire conditions. LPCB LPCB LPCB LPCB BS 5839-1:2013 ENHANCED TO CLAUSE 26.2 BS EN 50200:2015 CLASS Ph120 BS 8434-2:2003+A2:2009 C,W & Z OF BS6387:2013 Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance. Resistance to fire of unprotected small cables for use in emergency circuit. Test for unprotected small cables for use in emergency circuits. BS EN 50200 with a 930 C flame and with water spray. Requirements for cables to maintain circuit integrity under fire conditions. All 3 tests performed using the same cable sample. LPCB BS EN 50267 Gases evolved during combustion or electrical cables. Wrexham Mineral Cables are the ONLY Mineral Insulated Copper Cable manufacturer approved by the Kuwait Fire Department. Testing: WARRINGTON FIRE RESEARCH BS 6387:1994 CWZ (TO HIGHEST CATEGORY) WARRINGTON FIRE RESEARCH TO BS 4066: INTERNATIONAL STANDARD IEC 60331 LONDON UNDERGROUND TO SPECIFICATION EME-SP-14-028-A1 (FIRE SURVIVAL CABLES - MICC) Terminations: MANUFACTURED AND TESTED IN ACCORDANCE WITH BS EN 60702-2 SIRA QUALITY ASSURANCE NOTIFICATION APPROVAL IN ACCORDANCE WITH NUMBER: SIRA02ATEX1305X ATEX DIRECTIVE 2014/34/EU

Glands, Terminations & Tools We stock a full range of ATEX EExd approved cable glands and the required terminations, tools and low smoke & fume (LSF) fire rated fixings. Our purpose built 30,000sqft warehouse facility houses everything needed to install our cable. We provide training, installation guidance and support with video and documentation.

Applications & Industries Our MICC cable has been designed specifically for critical and life saving systems where continuity is required in the event of a fire. Critical & Life Saving Systems: EMERGENCY SHUTDOWN SYSTEMS STOP/START CONTROLS EMERGENCY LIGHTING FIRE ALARM SYSTEMS FIRE PUMPS FUME & SMOKE EXTRACTION FIRE DETECTION & PROTECTION SYSTEMS THEATRE / LIFE SUPPORT SYSTEMS SPRINKLER SYSTEMS INSTRUMENT/MONITORING SYSTEMS COMMUNICATION SYSTEMS LIFTS RECESS & HANDRAIL ILLUMINATION PUBLIC ADDRESS SYSTEMS MAINS DISTRIBUTION MOTOR OPERATED VALVES Industries: Multi-storey Car Parks Travelators/Escalators Airports Hospitals Shopping Centres Rail Networks / Metrolinks Industrial / Manufacturing Mining and Tunnels Hotels / Catering Skyscrapers / Tower Blocks Gas and Oil Refineries Nuclear / Power Stations

DON T TAKE RISKS, use the only TRUE fire survival cable. Survives fire longer, supports critical emergency systems and provides vital time for evacuation and shutdown procedures.

OUR CABLE HELPS SAVE LIVES Wrexham Mineral Cables Wynnstay Technology Park Ruabon, Wrexham, LL14 6EN TEL: +44(0)1978 810789 sales@wrexhammineralcables.com www.wrexhammineralcables.com 25 YEARS MANUFACTURING